7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
1/21
March 20th, 2013
Sabri Mohamed / Ngo Vi Lan
Snr Product Engineers
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
2/21
1
Background
8 GF65Y
647Y
8 GFi50Y
637Y
8 GFi65Y
647Y
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
3/21
2
Latest Smith Bits run by VSP
TD Date Well Name Well No Oper Size Type IADC Serial No Depth IN
(m)
Depth
OUT (m)
Int (m) Hrs ROP
(m/hr)
WOB
Hi(klbs)
Total
RPMHi
I O D L B B B G O RP
Aug-12 RC-DM# 410 VSP 8.5 GF65YBDOD1 647Y PR2453 4593 4599 6 29.4 0.2 30 45
Aug-12 RC-DM# 410 VSP 8.5 GF65YBDOD1 647Y PR2452 4138 4258 120 29.9 4.0 30 40 BHA
Aug-12 RC-DM# 410 VSP 8.5 GF65YBDOD1 647Y PR2454 4422 4593 171 50.3 3.4 40 40
Aug-12 RC-DM# 410 VSP 8.5 GFi50YOD1V 637Y PM3297 4071 4131 60 32.6 1.8 29 40 1 1 WT A E E E IN BT CP
Aug-12 RC-DM# 410 VSP 8.5 GFi50YOD1V 637Y PP9519 4258 4422 164 55.6 2.9 35 40
Aug-12 RC-DM# 410 VSP 8.5 GFi65YOD1V 647Y PS4079 4811 4891 80 34.9 2.3 35 40 HP
Aug-12 RC-DM# 410 VSP 8.5 GFi65YOD1V 647Y PS4080 4891 4972 81 47.4 1.7 35 40
Aug-12 RC-DM# 410 VSP 8.5 GFi65YOD1V 647Y PN6695 4694 4811 117 42.0 2.8 35 45 5 8 SD A E E E 1 LT PP
Feb-10 1209 VSP 8.5 FGi40YOD 617Y 4858 4868 10 5.0 2.0 20 70 1 1 1 1 1 1
Feb-10 1209 VSP 8.5 FGi40YOD 617Y 2927 3028 101 20.0 5.1 26 90
Feb-10 1209 VSP 8.5 FGi40YOD 617Y 4868 4998 130 15.0 8.7 44 80 2 2 2 2 2 2
Feb-10 1209 VSP 8.5 GFi50YOD1V PP0054 4735 4858 123 8.8 14.1 35 60 3 3 3 3 3 3
Feb-10 1209 VSP 8.5 GFi50YOD1V PP0070 4430 4735 305 29.9 10.2 33 60 2 2 2 2 2 2
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
4/21
3
Smith bits performance in
VSP DM-410 well8 GFi65YOD1VRD sn: PN6695 IADC: 647Y. 117m with mud motor
GFi50YOD1VRDPM3297
60m
GF65YBDOD1RD
PR2452127m 4.0 m/r
1-2-W T-A-E-I-CT-BHA
GFi50YOD1VRDPP9519
164m 2.9 m/hr
2-1-W T-A-E-I-NO-HR
GF65YBDOD1RDPR2454
171m 3.4 m/hr
4-3-LT/BT-A-E-I-W T-HR
GF65YBDOD1RD
PR2453101m
3-4-WT-A-E-1/16-BT-BHA
GFi65YOD1VRDPN6695
117m 2.8 m/hr
5-8-SD-G-E-1-LT/BT/W T-PP
GFi65YOD1VRDPS4079
80m
2-3-W T-G-E-I-NO-HR
GR & Sonic
(RM) (ECO[1] ) (6in)( GR)
0 200(GAPI)
Delta-T Compressio nal (DTCO)
140 40(us/f)
SH CLAY CLYS MARL SS SILT CNGL
CHRT AN HL VOLC IGNE META PYRT
LS CHAL DOLCOAL
Lithology
UCMPS0 30000(psi)
FORMATION
ABRASION
NORM
AL
M
OD
ERATE
HE
AVY
V.H
EAVY
FORMATION
IMPACT
NORM
AL
M
OD
ERATE
HE
AVY
V.H
EAVY
M.Depth
(m)
42503664.67 TVDSS
45003729.46 TVDSS
47503724.50 TVDSS
1-1-WT-A- E-I-BT-CP
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
5/21
4
Smith Bits gauge conditions
Gauge durability is a concern and need to be improved upon
Inner row needs to be improved too if the gauge is performing
8 GFi65YOD1VRD sn: PN6695 647Y
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
6/21
5
Issues on GFi65Y
Gauge durability- Need more inserts on gauge
Durability mainly in the inner row
Lost Cones
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
7/21
6
Gauge durability- Need more inserts on gauge
- More inserts in the adjacent to gauge areaDurability
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
8/21
7
8 FHi70YOD1RD
Gauge durability- Need more inserts on gauge
- More inserts in the adjacent to gauge area
- Larger and more ATLAS in the heel row
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
9/21
Large
Small
8
8 FHi70YOD1RD
Gauge durability- Need more inserts on gauge
- More inserts in the adjacent to gauge area
- Larger and more ATLAS in the heel row- Reduce radial gauge load
R load
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
10/21
9
8 FHi70YOD1RD
Gauge durability- Need more inserts on gauge
- More inserts in the adjacent to gauge area
- Larger and more ATLAS in the heel row- Reduce radial gauge load
ROP???
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
11/21
10
High Journalangle Low Journalangle Medium Formations Soft to Medium Formations
So wheres the ROP is going to come from?
- Lower journal angle
8 FHi70YOD1RD
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
12/21
11
Performance of Low Journal angle
TYPE SE RI AL DEPTH DE PTH DRLG HRS Krevs ROP P a r a m e t e r s ANGLE DULL CODE
Well M FGR MFGR NO. I N OUT On m /hr WOB RPM FL OW
(m) (m ) (m ) Botto m ( Klb s) (GPM) ppg
SD 5X G F45 Y OD 1R D S mi th M X299 4 26 8 6 3358 672 44. 8 520 1 5 .0 4 05 0 190 20 0 51 5 9. 5 57 8 7 C T A E 3 BT HR
SD12I MX 55D X H TC 506 1118 28 83 3552 669 29. 1 359 2 3.0 3 04 0 140 /2 20 55 0 9. 2 33 7 8 B T H F 2 C D TQ/PP
SD8I MX 55D X H TC 505 2562 43 24 4974 650 42. 5 489 1 5.3 4 05 0 2 10 54 0 8. 6 52 3 4 WT A F 1 ER HR
SV3P G F45 Y OD 1R D S mi th M Z391 9 33 9 7 4021 624 35. 6 399 1 7 .5 44 5 2 10 55 0 SW 71 4 5 WT A E 3 BT /LT P P
SD 21P MXL D S55 DX 2 H TC 509 6109 31 12 373 2 620 36. 7 363 1 6.9 3 54 5 140 19 0 50 0 9 76 6 8 LT A F 5 C D TQ
SV7P SEB 26 85D3P SEC 1 127 568 8 45 05 512 4 619 40. 5 497 1 5.3 4 5 2 05 50 0 SW 88 2 3 WT A E 2 BT HR
SV2P G F45 Y OD 1R D S mi th M Z391 6 36 7 2 4283 611 40. 0 375 1 5 .3 25 5 120 18 5 45 0 8. 6 88 2 4 WT A E 3 LT HP
MUDWt
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
13/21
12
So wheres the ROP is going to come from?
- Lower journal angle
- Higher gauge scraping distance
8 FHi70YOD1RD
Large
Small
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
14/21
13
Row Scraping Distribution Comparison
So wheres the ROP is going to come from?- Lower journal angle
- Higher gauge scraping distance
- Increase scraping in the inner rows
8 FHi70YOD1RD
Large
Small
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
15/21
14
8 FHi70YOD1RD
Durability :-A more equally balanced force between all 3 cones
Large
Small
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
16/21
15
Gauge durability
ROP
Lost Cones
8 FHi70YOD1RD
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
17/21
16
Improvement made on FHi70Y to avoid lost cones
- Thicker cones
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
18/21
17
Improvement made on FHi70Y to avoid lost cones
FHi69UY FHi70Y
- Shallower grooves
- Thicker cones
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
19/21
18
8 FHi70YOD1RD : Conclusions
Gauge durability- Need more inserts on gauge
- More inserts in the adjacent to gauge area
- Larger and more ATLAS in the heel row
- Reduce radial gauge load
ROP from inner rows
- Lower journal angle
- Higher gauge scraping distance- Carbide grade
- Cone force balanced
To tackle lost cones issues
- Thicker cone shell- Shallower grooves on the cone shell
- Half carburization on the ball race
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
20/21
ER8600 8 FHi70YOD1RD IADC 647YER8600 8 FHi70YOD1RD IADC 647Y
FeaturesY : Conical
OD1 : 100% Diam ondinsert s on the heel rows
RD : Diam ond inser ts onlegback
i : IDEAS des ign
maximumbottomholecoverage
100% large diameter ATLASdiamond enhanced inserts on heel
row
Designed specifically for drilling very hard and abrasive granite in Vietnam. Design criteria are based on lessonlearnt from previous 8 FHi69UYOD1GRD run.
Gauge durabil ity
Low journal angle
Harder carbide grade
Cone force balanced
Thicker cone shell
Half carburization on the ball race
-
7/28/2019 8-1/2 Bit FHi70Y Presentation to Customers Mar 2013 VSP
21/21