Download - 2722 CAT6A Reference Guide
-
CAT 6A Reference Guide
-
Thank you for choosing Leviton Network Solutions. Our copper, fiber, power, and Connected Home solutions are ideal for today's most demanding applications, consistently exceeding our customers expectations. Leviton CAT 6A structured cabling solutions are no exception. UTP eXtreme 6A channel- and component-rated performance options plus a shielded solution meet the needs of any application.
Our component-rated UTP CAT 6A connectivity solution is the first in the industry to achieve third party verification through Intertek/ETL. Our channel-rated UTP solution balances economy with Leviton performance. And shielded connectivity delivers the signal isolation and data security essential in government, gaming, medical, and financial installations.
-
TABLE OF CONTEN
TSUNDERSTANDING CAT 6AStandardsLeviton CAT 6A ExpertiseLeviton CAT 6A Systems
HORIZONTAL CABLINGCAT 6A Cable TypesRouting & HandlingPathways & Spaces
TELECOMMUNICATIONS ROOMPatch PanelsCable Management ProductsCable AssembliesManaging Cords
WORK AREACablingWorkstation
080911
14151718
020305
DATA CENTER APPLICATIONSPathways & SpacesNew CAT 6A DC Solutions
CAT 6A TERMINATIONTips110-Style Patch Panels UTP ConnectorsShielded Connectors
CAT 6A TESTINGPerformance TestsAXT Testing
LEVITON PART NUMBERS
GLOSSARY
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
2021
28293133
3637
43
39
2425
-
INTRODUCTION1.
Understanding CAT 6A
Equipment, design and planning, and installation practices for CAT 6A projects are all significantly different from previous generation structured cabling systems. Use this guide to gain a better understanding of these unique requirements, which will in turn help you accurately bid jobs and shorten installation time. The final result will be a high-performance system that supports todays requirements and provides a smooth migration path toward 10G network performance.
-
2leviton.co
m/cat6a
| 8
00.722
.208
2
Organization: TIA (Telecommunications Industry Association)
Standard: 568-C.2 (replaces 568-B.2-10)
Defines: Performance requirements for CAT 6A channels, permanent links, and components
Organization: IEEE (Institute of Electrical and Electronics Engineers)
Standard: 802.3an
Defines: Channel performance for 10GBASE-T Ethernet over balanced twisted pair cables
Organization: ISO (International Standards Organization)
Standard: 11801; Class EA Specification
Defines: Class EA cabling and component performance requirements for customer premises. ISO equivalent of CAT 6A; commonly specified outside of North America
The Category 6A (Augmented Category 6) standard addresses the performance demands of 10 Gigabit Ethernet (10GBASE-T). Several organizations detail aspects of the standard, but all define 6A performance as up to 500 MHz and a maximum distance of 100 meters (328 feet). CAT 6A is backward compatible with CAT 6, 5e, 5, and 3 performance and applications.
STANDARDS
CH. 1
INTRO
-
Technical Support & Applications Engineering
When you need assistance with your next CAT 6A project, from selecting the best products for an application to tips on building or installing a system, contact our technical support team. Team members have extensive training on CAT 6A standards and applications, and can help work through your questions as you complete your first 10G installations.
Levitons expert team of applications engineers provides CAT 6A infrastructure design assistance. Each design is built around the specific needs of your active equipment, network topology, and transmission methods. The unique requirements of facilities such as data centers, government agencies, health care facilities, and high-rise structures are also incorporated. Just as important, the team utilizes its thorough understanding of industry standards and product functionality to plan systems that will accommodate industry trends and future needs.
Call 800.824.3005 or +1.425.486.2222 or email [email protected] for technical support or applications engineer assistance.
3LEVITON CAT
6A EXPE
RTISE
CH. 1
INTRO
3
-
4leviton.co
m/cat6a
| 8
00.722
.208
2
Specification Support
Levitons nationwide team of specification engineers supports consultants, architects, specifiers, and engineers who design network systems. All team members hold BICSIs RCDD certification, and are members of the Construction Specifications Institute. These engineers thoroughly understand the demands placed on different network environments, and specify only the equipment that will provide optimal performance in each installation. In addition, Leviton offers direct field support and materials for use in bids, design plans, RFPs, and specification documents, including BIM (building information modeling) objects, CAD drawing files, Visio stencils, and bid spec/RFP documents.
Visit leviton.com/specteam or email [email protected] for more information.
Leviton Contractor Program
For guaranteed product performance, choose a Leviton Contractor Program installer. The program builds on contractor experience and knowledge to ensure quality installation of Leviton Network Solutions products. Program installers attend Levitons training course, which includes the latest structured cabling standards, industry technologies, installation techniques, and field-testing methods. Most importantly, they offer more value to their customers with a lifetime product and performance warranty on qualified projects.
Visit leviton.com/lcp or email [email protected] for more information.
LEVITON CAT
6A EXPE
RTISE
CH. 1
INTRO
Contractor Program
-
5All category-rated solutions are channel rated, meaning that the end-to-end system has been tested to perform at or above its standards requirements. Levitons channel-rated system balances economy with Leviton quality and performance. Our exclusive Cone of Silence helps suppress alien crosstalk, a dual layer wiring scheme label simplifies termination, and patented Retention Force Technology protects against damage from four- or six-pin plugs.
Levitons component-rated system delivers industry-leading performance for todays high bandwidth applications. Component-rated performance is more stringent than channel-rated; each connectivity element is guaranteed to meet or exceed the standards performance. To provide greater headroom in high-density and short-link installations, Leviton has designed and engineered a component-rated CAT 6A connector with patent-pending triple-stage compensation. An advanced rigid circuit board design, engineered tine geometry, and a flexible circuit provide compensation to minimize the adverse effects of return loss, near end crosstalk, and alien crosstalk.
Like our CAT 6A UTP solutions, Levitons shielded solutions exceed CAT 6A performance standards and protect network traffic from alien crosstalk. Our shielded solutions offer a high level of data security and EMI/RFI protection for government, healthcare, gaming, financial, manufacturing, and other sensitive environments. With shielding, internal data signals are securely contained and isolated from interference.
Channel-Rated UTP System Component-Rated UTP System Shielded SystemLEVITON CAT
6A SYST
EMS
CH. 1
INTRO
-
6leviton.co
m/cat6a
| 8
00.722
.208
2
QuickPort connectors SlimLine patch cords 110-style patch panels QuickPort patch panels 110-style wiring blocks
UTP Channel- & Component-Rated
Die-cast QuickPort connectors SlimLine patch cords QuickPort patch panels
Shielded
LEVITON CAT
6A SYST
EMS
CH. 1
INTRO
-
CAT 6A cable is considerably different from previous generation cable.Its larger outside diameter (OD), corresponding larger minimum bend radius, and heavier weight will change installation requirements for routing and handling as well as design of pathways and spaces.
How is CAT 6A Cable Unique?
TIA standard allows up to .354" outside diameter (OD), a 54% increase over CAT 6 OD average of .23"
More than twice the weight of typical CAT 6 cable Tighter twists and larger conductor size than CAT 6 and 5e Typically comes on large reels and requires special reel-handling equipment
CAT 6
CAT 6A
HORIZONTAL CABLING2.
-
8leviton.co
m/cat6a
| 8
00.722
.208
2
1st Generation UTP
2nd Generation UTP
2nd generation UTP cable also has tighter twists and larger conductors than CAT 6, but incorporates new cable design elements such as filler tubes or non-conductive isolation wraps that allow a smaller cable OD while retaining 6A performance. 2nd generation cable is lighter and offers better performance with a smaller bend radius.
Shielded
Shielded cable provides higher immunity to EMI/RFI and has a smaller OD, typically .29" - .32". However, the cable has a drain wire and foil shield that will increase installation time. In addition, every component in the system must be shielded and properly bonded to ground in order to be effective.
CAT 6A Cable Types
Most 1st generation UTP cable is designed and manufactured with tighter twists, larger conductor size, and more complex center splines than CAT 6 cable. These characteristics increase cable OD and result in heavier cable weight, reduced fill capacity, and a larger bend radius.
2nd Gen1st Gen shielded
Maximum Horizontal Cable DistanceTIA specifies 90 meters (295 feet) as the maximum permanent link length and 100 meters (328 feet) for maximum channel length.The standards do not specify a minimum length, but 10 feet is recommended to avoid return loss and NEXT issues due to the higher signal frequency. Leviton is the only manufacturer to provide lifetime warranty coverage on qualified installations for a 10 foot permanent link, critical in data center applications.
Cable Type 5e 6 6A Gen1 6A Gen2 6A Shielded 6A Max
Average OD .185" .230" .330" .300" .290" .354"
2nd Gen1st Gen shielded 2nd Gen1st Gen shielded TEC
H TIP
-
9Cable Reels
Typically, CAT 6A cable will come on reels instead of in pull boxes and will require racks/carts that can support their larger size.
Cable Pulling
The maximum pulling tension for a 4-pair balanced twisted pair cable must not exceed 25 lbf (110N). Exceeding this tension will result in transmission degradation and may affect the systems ability to pass certification testing.
Leviton VELCRO Brand FastenersUse Leviton's VELCRO Brand fasteners to secure all cable bundles. Our genuine VELCRO Brand products wont crush or damage cables like tie wraps can, and are reusable for moves, adds, and changes.
Larger, heavier CAT 6A cables require modifications to traditional cable routing and handling techniques.
Follow the tips here to help ensure a smooth installation.
DO DON'TSPOTLIGHT
ROUTING & HANDLING
CH. 2
HORIZ. CABLING
-
10
leviton.co
m/cat6a
| 8
00.722
.208
2
CH. 2 Bend Radius
Slack Loops
Placement
To maintain CAT 6A performance, minimum bend radius should exceed 4x OD for UTP and shielded cable. This radius is significantly larger than CAT 6 and 5e. Plan carefully to ensure there is sufficient space throughout cable runs to maintain proper bend radius.
TIA recommends storing 10 feet of extra cable in the telecom room and 12-18 inches above work area installations for re-terminations and to accommodate moves, adds, and changes. Use an extended or figure 8 loop configuration to alleviate cable stress. Cable slack in bundled or excessive loops has been shown to degrade cable performance and is associated with return loss failures. Plan carefully to ensure there is sufficient space and support for heavy CAT 6A cable slack loops.
Leviton approved-partner CAT 6A cable may be placed in the same tray with CAT 6, 5e, and other category-rated cables. In addition, Leviton warrants its product performance whether strict combing or randomizing dressing methods are used. As with all cable runs, large or heavy cable bundles should be positioned under other cable to prevent crushing. Follow NEC code for separating power and data cables.
Pulling LubricantsTo maintain CAT 6A performance, choose spray or wipe lubricants specifically designed for data communications cables. Using other lubricants can degrade performance; the majority of insertion loss failures have been traced back to the use of general purpose lubricants.
ROUTING & HANDLING
TEC
H TIP
Note: In 568-B.2-10, CAT 6A shielded cable bend radius was 8x OD.
HORIZ. CABLING
-
11
CH. 2 Cable Tray Fill
TIA-569 recommends 25% fill at initial installation and up to 50% with unplanned additions.If a single cable tray will also carry power cables, a physical barrier is required to comply with the NEC. Finally, ensure tray support spacing is sufficient to prevent excessive sagging. Consider solid bottom tray for higher density applications.
Conduit Fill
Structural & Cable Supports
A maximum conduit fill ratio of 40% is recommended by TIA-569 standards to accommodate cable bundle bend radius requirements and allow for future expansion.
Stronger anchors and threaded rods are needed to support heavier CAT 6A cable
Use properly sized J hooks and other supports to accommodate bundle size
Limit bundles to 50 cables to prevent damage to cables on the bottom
Do not exceed cable support manufacturers recommended capacity
Space cable supports randomly between 3 and 4 feet apart to prevent system degradation due to sagging
Do not use ceiling support wires or other ceiling components to support communications infrastructure
Typical Tray & Conduit Capacity (# of cables)
5e 6 6A1 6A2 6AS
Average OD .185" .230" .330" .300" .290"
Cable
Tray* 2" x 6" 111 72 35 42 45
4" x 8" 298 192 93 113 1216" x 20" 1116 722 350 424 454
Con
duit** 3/4 6 5 1 3 3
1 11 8 4 4 51 1/4 19 14 6 8 91 1/2 25 19 9 11 12
*25% fill ratio
**EMT Trade Size. Calculations based on industry standards of 53% capacity for 1 cable, 31% for 2 cables, and 40% for 3 or more cables.
Note: 6A1 = 1st generation, 6A2 = 2nd generation, 6As = Shielded
PATHWAY
S & SPA
CES
HORIZ. CABLING
-
12
leviton.co
m/cat6a
| 8
00.722
.208
2
TELECOM ROOM
CONSOLIDATION POINT
HORIZONTAL UTP CABLE
PERMANENT LINK (90m)
CHANNEL (100m)
DVR/NVR
PATHWAY
S & SPA
CES
CH. 2 Consolidation Points & Zone Enclosures
TIA standards allow an optional consolidation point (CP) within a permanent link. A CAT 6A 110 block is Levitons standard CP solution; density is 1/3 less than CAT 6 110 blocks (64-pair CAT 6A capacity vs. 96-pair for CAT 6 in the same footprint).
Consolidation points may be mounted into a Leviton zone enclosure, which are available in several styles:
Ceiling- or floor-mount Plenum-rated Active or passive equipment rated
Cable Tray Sizing
To determine the proper tray size based on 25% fill, use the following calculation:
Step Instructions Example
1 Determine cable diameter and total number of cables .30" diameter each, 100 cables total
2 Square the cable diameter .30 x .30 = .09
3 Multiply result by number of cables .09 x 100 = 9
4Multiply result by .785 to factor for cable roundness(This result is the total cross-sectional area of your cables)
9 x .785 = 7.065 sq in
5 Multiply result by 4 to obtain pathway size at 25% fill 7.065 x 4 = 28.26 sq in
At 25% fill, a 28 sq in area is needed, so a standard 4" x 8" tray would be adequate.
Note: For conduit, size for 40% fill by substituting 2.5 as the multiplier in Step 5
Zone enclosures also accept patch panels and/or active equipment, and are then considered telecom enclosures (TEs).
FirestoppingCAT 6A cables may require larger firewall penetrations. Always follow applicable national code (e.g. NEC or CEC) or a superceding authority-having jurisdiction (AHJ) codes for firestopping requirements.T
ECH TIP
HORIZ. CABLING
-
Organizing cable runs at racks and cabinets is essential to a well-managed network. Larger, heavier CAT 6A cables may require special planning and equipment for a successful installation. Select the best patch panels, cable management, and patch cords or trunks for your application to speed installation and simplify ongoing management.
TELECOMMUNICATIONS ROOM3.
-
14
leviton.co
m/cat6a
| 8
00.722
.208
2
110-Style
C1 Ultra QuickPort
1RU 24-port flat and angled 2RU 48-port flat and angled
Our newest panel offers a high-end aesthetic, superior strength, and customization capabilities perfect for data centers and other showroom-style applications.
QuickPort
Shielded
1RU 24-port 2RU 48-port 2RU 72-port high-density
Shielded panels are ideal for installations where data security and signal isolation are critical, including government agencies, banking, gaming, and hospitals.
Flat 110-style panels are our most popular models; they can be used in a wide variety of applications and offer a standard IDC field with easy punchdown.
Our QuickPort panels allow you to color-code your CAT 6A installations, mix-and match media, and to add connectors as more capacity is needed.
2RU 48-port flat composite
1RU 24-port flat and angled QuickPort 2RU 48-port flat and angled QuickPort
C1 Ultra Composite Patch Panel
For the ultimate in panel design and customization capabilities, choose Levitons new C1 Ultra. Polymer construction has a higher strength-to-weight ratio than 16-gauge metal and a look totally unique in the industry. Custom labeling options include A/B switch fabric color-coding, corporate or school logos, or virtually any front panel design.
PATC
H PANELS
CH. 3
TELECOM ROOM
VertiGO Zero-U
Patented VertiGO Zero-U panels can be mounted on racks or cabinets, to a ladder tray or wire basket, directly to the wall, under a raised floor, or even onto modular furniture.
12-port panel only, 3" rear channel, or 6" rear channel
Flat, angled, recessed angled, and recessed flat:
1RU 48-port high-densityFlat and angled:
SPOTLIGHT
-
15
CH. 3 Vertical Management
8" High-Capacity Versi-Duct 5" Versi-Duct
80" length, standard hinged black cover, front only 80" length, standard hinged black cover, front and rear 80" length, designer hinged grey cover, front only 80" length, designer hinged grey cover, front and rear Center mounting bracket, 8" channel Cable retainer and slack loop organizer, 8" channel
80" length, standard snap-on black cover, front only 80" length, standard snap-on black cover, front and rear 40" length, standard snap-on black cover, front only 40" length, standard snap-on black cover, front and rear Grey snap-on designer cover, front and rear Mounting bracket, 5" channel
High-capacity Versi-Duct is ideal for CAT 6A installations, especially large deployments. Choose a designer cover for a sleek look in showroom environments.
Choose 5" Versi-Duct for smaller installations where its capacity meets installation needs, including future growth (see capacity chart below).
Versi-Duct Capacity (# of cables)CAT 6A Gen1 CAT 6A Gen2 CAT 6A Shielded
Average OD .330" .300" .290"
Fill Rate 25% 50% 25% 50% 25% 50%
5" Channel Size 45 90 55 110 59 118
8" Channel Size 145 290 177 354 190 380CABLE MANAGEM
ENT
TELECOM ROOM
-
16
leviton.co
m/cat6a
| 8
00.722
.208
2
CABLE MANAGEM
ENT
CH. 3 Horizontal Management
Versi-Duct Rear Cable Management Support Bars Standard Front Cable Management Front only Front and rear 1 and 2RU grey designer covers Bend radius limiters
Standard flat, angled, and recessed angled Extended flat High-density flat Rear manager for active equipment flat
1, 2, and 4RU managers with metal rings 1 and 2RU managers with plastic saddles SpaceMaker manager
Choose horizontal Versi-Duct as part of a complete Versi-Duct cable management solution, or in installations where aesthetics or large finger spacing are priorities.
Rear support bars complement specific panel styles and are included with all Leviton flat panels.
Standard front managers complement Leviton panel styles and keep patch cords visible for easy identification.
Leviton VELCRO Brand Fasteners
5", 8", and 12" tie wraps in four colors plus plenum-rated maroon 15' and 75' bulk rolls in four colors plus plenum-rated maroon 600' bulk rolls 15" compression straps in four colors 75' SoftCinch Lite 1/2" wide rolls Utility fasteners including saddle ties, J hooks, workstation loops, and storage rings
Need cable management for use in air handling spaces? Levitons large selection of genuine VELCRO Brand fasteners includes several styles in plenum-rated maroon.S
POTLIGHT
TELECOM ROOM
-
CABLE ASS
EMBLIES
CH. 3 Leviton Pre-Terminated Copper Trunks
Copper trunks are part of Levitons extensive, quick turnaround make-to-order (MTO) program. The custom-configured cable assemblies speed installation at data centers and other large, critical applications. By shifting much of the assembly work to the factory, field installation time is reduced by up to 80%.
All Leviton trunks include a braided sleeve with pulling eye to protect terminations during shipment, ensure easy installation, and keep trunk assembly organized. In addition, our pre-terminated trunks are 100% factory tested and shipped with test results and individual cable serial numbers. No further testing is necessary after installation, and qualified installations are eligible for our limited lifetime product and performance warranty.
Custom-configuration options:
Cable type Breakout and overall length (10-295 feet/90 meters) Jack, plug, or open termination Even or staggered connector alignment Cable and jack color Plenum or riser sleeve
Leviton SlimLine Patch Cords
Leviton CAT 6A patch cords feature our exclusive SlimLine plug design. The narrow profile plugs reduce congestion in high-density applications. In addition, they feature a strain relief boot for long-term network performance, and a snagless design to prevent tab breakage. An industry-leading outside diameter of .240" further reduces congestion while 26-gauge stranded cable provides maximum flex-life.
Cable construction provides excellent alien crosstalk (AXT) suppression and EMI/RFI protection. In fact, the same cord is deployed for UTP and shielded applications. SlimLine patch cords are component-rated for optimum channel performance. The cords are available in 6 standard lengths from 3 to 20 feet, and in 8 popular colors.
SPOTLIGHT
TELECOM ROOM
17
-
18
leviton.co
m/cat6a
| 8
00.722
.208
2
Cable & Cord Dressing
Rear of Rack (cables)Whether routing cables from above or below, symmetrically distribute bundles to feed into each panel from left and right. This will balance the cable bundles, allow easier access to connections, and reduce congestion at the rear of the panels. Leviton rear cable managers, Versi-Duct vertical and horizontal finger duct (front/rear versions), and VELCRO Brand fasteners all support CAT 6A cable at the rear of racks and cabinets.
Front of Rack (cords)Symmetrically dress cords and route into cable management. Levitons CAT 6A cords have been independently and field-tested to ensure 10G performance whether they are strictly combed or randomized in cable managers. Our horizontal ring-type cable managers as well as horizontal and vertical Versi-Duct products help manage patch cords at the front of the rack. To reduce cord bundle sizes, consider using angled patch panels with vertical Versi-Duct. Also consider Leviton SlimLine CAT 6A patch cords; their low-profile will reduce congestion at the face of the patch panel and on high-density switch equipment.
MANAGING CORDS
CH. 3 Bend Radius
To maintain CAT 6A performance, minimum bend radius should exceed 4x OD for both UTP and shielded. For CAT 6A cables, this radius is significantly larger than CAT 6 and 5e. Plan carefully to ensure there is sufficient space to maintain proper bend radius.
Color CodingEnhance data center and telecom room organization by color-coding connectors and patch cords. Choose from several schemes, depending on application and system management priorities:
A/B switch fabric for data center redundancy Connectivity types such as WAN/corporate data, LAN,
engineering networks, voice, and more Campus location Company colors
TEC
H TIP
Note: In 568-B.2-10, CAT 6A shielded cable bend radius was 8x OD.
TELECOM ROOM
-
Connectivity in the work area requires a finished look, ease of maintenance, and performance, all while meeting installation codes and guidelines. Simplify work area connectivity planning, design, and installation with the following tips.
WORK AREA4.
-
20
leviton.co
m/cat6a
| 8
00.722
.208
2
In-Wall Applications
CAT 6A cables require additional depth behind faceplates and at all directional changes to maintain proper bend radius. Before installation, verify that the design allows sufficient depth throughout the run.
WORKAREA
WORK AREA
CABLING
CH. 4
Drop Ceiling Applications
Cable infrastructure must be independently suspended by components designed for this purpose, separate from all other building systems. Do not use ductwork, piping, earthquake bracing, or the drop ceiling grid to suspend cable or cabling support infrastructure.
Leviton Consolidation Points & Zone Enclosures
Reduce the cost and complexity of moves, adds, and changes with Levitons consolidation point (CP) solutions. Our TIA-compliant solutions allow businesses to add an interconnection point within a horizontal cabling permanent link. When work areas are modified, cabling need only be reconfigured back to the consolidation point, rather than all the way to the telecom room.
Levitons standard CAT 6A consolidation point solution is our 110-style wiring block. Mount into a Leviton zone enclosure, available in several styles:
Ceiling- and floor-mount Plenum-rated Active or passive equipment rated
Zone enclosures also accept patch panels and/or active equipment, and are then considered telecom enclosures (TEs).
Active Ceiling Enclosure
Passive Raised-Floor Enclosure
110-Style Wiring Block
SPOTLIGHT
-
21
Junction Boxes and Mud Rings
Verify that the connectivity design specifies the proper junction box size before drywall is installed. Consider an oversized junction box to accommodate CAT 6A cabling and bend radius requirements, or use mud rings (box eliminators) instead.
WORKSTAT
ION
CH. 4 Surface Mount Boxes
To maintain proper bend radius, consider exiting cable from modular furniture pathways into a surface mount box instead of directly to a faceplate. Levitons extended depth four-port surface mount box works with most modular furniture and is an excellent solution for larger CAT 6A bend radius requirements.
Modular Furniture Installations Cubicle furniture and walls often have restricted wireways. Determine cable capacity before finalizing specifications to verify there is adequate space for cables and bend radius requirements. Consider mocking up a cubicle. Most cubicle installations use surface mount boxes or modular furniture faceplates, which help offset the space restrictions of narrow cubicle walls.
TEC
H TIP
WORKAREA
-
22
leviton.co
m/cat6a
| 8
00.722
.208
2
WORKSTAT
ION
CH. 4
Leviton QuickPort Faceplates & Inserts
Leviton offers numerous QuickPort opening faceplates to match any dcor. Choose from:
Standard commercial, Decora or Acenti designer, or Excella British Standard styles Stainless steel construction or thermoplastic in seven popular colors Single- or dual-gang with 1- to 12-port capacity Openings for data connectors or multimedia connectivity With or without ID windows
Standard Commercial Acenti ExcellaAngledDecora
SPOTLIGHTWORK
AREA
-
DATA CENTER APPLICATIONS5.
Data centers are one of the most critical parts of any data network and thus require the highest levels of performance and reliability. Cabling for data centers differs from horizontal installations in several ways: typical distances, network function, pathways and spaces, and more. CAT 6A cabling may affect requirements for all of these, but especially pathways and spaces. Careful planning and proper specifications will help ensure a successful installation.
-
24
leviton.co
m/cat6a
| 8
00.722
.208
2
PATHWAY
S & SPA
CES
CH. 5
DATACENTER
Raised Floor vs. Overhead Cable Runs
There are three typical data center CAT 6A cable run configurations: power and data cabling both under a raised floor, both overhead, or power below and data overhead. The chosen configuration will affect other data center design elements:
If power and communications cable are both overhead, cable trays must be properly sized, separated, and configured to support 6A cables and accommodate power runs.
If both are underfloor, pedestals must be higher to accommodate larger 6A cables, room for expansion, segregation from power runs, and proper airflow.
Follow best-practice CAT 6A installation guidelines to achieve and maintain optimum performance:
Pathways should be sized for 25% initial fill ratio, which allows space for up to 50% fill with future additions. Pathways should be no more than 6" deep; larger deployments may use multiple trays or pathways to support cabling requirements.
Space cable bundle supports every three to four feet at irregular intervals.
Leviton trunks can be pre-terminated or field terminated. There are numerous advantages to using pre-terminated trunks, including factory testing for alien crosstalk (AXT); see page 17 for a detailed discussion.
Leviton Component-Rated Performance
Leviton component-rated CAT 6A solutions offer guaranteed performance at permanent link distances as short as 10 feet, which is critical in data center applications. How? With patent-pending triple-stage compensation. An advanced rigid circuit board design, engineered tine geometry, and a flexible circuit combine to enhance permanent link and channel performance, and minimize the adverse effects of near end crosstalk (NEXT), return loss (RL), and alien crosstalk (AXT). S
POTLIGHT
-
Pre-Terminated Copper Trunks
Reduce installation time by up to 80% with Leviton make-to-order (MTO) copper trunks. All MTO trunks are 100% factory tested and shipped with test results and individual cable serial numbers. No further testing is necessary after installation, and qualified installations are eligible for our limited lifetime product and performance warranty.
Configuration options: Cable type Breakout and overall length (up to 90 meters)
Jack, plug, or open termination Even or staggered plug alignment Cable and jack color Plenum or riser sleeve
Leviton C1 Ultra Composite Patch Panel
The new Leviton C1 Ultra combines strength and durability with a sleek look ideal for data centers. Polymer construction has a higher strength-to-weight ratio than 16-gauge metal and a look totally unique in the industry. Custom labeling options include A/B switch fabric color-coding, corporate or school logos, or virtually any front panel design. The 2RU 48-port flat QuickPort panel accepts eXtreme CAT 6A component- or channel-rated connectors.
80" length with standard hinged black cover, front only or front and rear 80" length with designer hinged grey cover, front only or front and rear Center mounting bracket Cable retainer and slack loop organizer
8" x 8" Versi-Duct Cable Management
High-Capacity Versi-Duct is ideal for CAT 6A data center installations. The large channels accommodate larger outside diameter CAT 6A cables, while channel covers help create a finished look in showroom-style installations. Managers can be side or center mounted for optimal space utilization.
NEW
CAT
6A SOLU
TIONS
CH. 5
DATACENTER
25
-
26
leviton.co
m/cat6a
| 8
00.722
.208
2
NEW
CAT
6A SOLU
TIONS
CH. 5
DATACENTER
Component-Rated Connectors
For unparalleled performance, choose the eXtreme CAT 6A component-rated connector the first in the industry to achieve this stringent benchmark. It has the best available performance for short run applications, down to a 10' permanent link. In fact, it's so well designed, it even meets component requirements when loaded in a 1RU 48-port QuickPort panel.
Leviton-exclusive features combine to deliver a connector with best-in-class performance and functionality:
Patented dual-layer T568A/B label with larger wiring diagrams Patented Cone of Silence and metalized body help suppress alien crosstalk (AXT)
Patented Retention Force Technology protects against damage from four- or six-pin plugs
Patent-pending triple-stage compensation enhances margin performance and augments AXT suppression
Sharper Pair Separation Towers ease conductor separation Conductor retention feature holds wires during termination
SlimLine Component-Rated Patch Cords
Leviton SlimLine patch cords feature a narrow profile plug to reduce congestion in high-density data center applications. A wealth of features maximizes performance:
Exceptional alien crosstalk suppression and EMI/RFI protection The same cord is used for both UTP and shielded applications Strain relief boot ensures long-term network performance Snagless design prevents tabs breakage during moves, adds, and changes 26-gauge stranded cable and .24" OD provide maximum flexibility
Leviton Data Center Specialists
Need help with a CAT 6A data center infrastructure project? Our DC specialists provide technical support including design, layout, elevations, pathways, and specifications to support any data center architecture and equipment requirements. Team members average more than two decades of industry experience and have a deep understanding of industry best practices and our customers needs.
Email [email protected] for more information.
SPOTLIGHT
-
CAT 6A TERMINATION6.
Termination steps for CAT 6A connectors are much the same as for CAT 6, with the major exception of handling the cables larger OD. To compensate, Leviton has designed several exclusive features into its new CAT 6A connectors to speed termination. Read on for details of these features, other tips for a seamless installation, and for termination instructions for our 110-style panel, UTP connectors, and shielded connector.
-
28
leviton.co
m/cat6a
| 8
00.722
.208
2
Component-Rated CAT 6A
Channel-Rated CAT 6A
Shielded CAT 6A
Extra Cable for Re-terminations
TIA recommends storing 10 feet of extra cable in the telecom room and 12-18 inches above work area installations for re-terminations and to accommodate moves, adds, and changes. Use an extended or figure 8 loop configuration to alleviate cable stress. Cable slack in bundled or excessive loops has been shown to degrade cable performance and is associated with return loss failures.
Leviton CAT 6A Connectors
All eXtreme CAT 6A UTP connectors include several features that deliver ease-of-use and superior performance:
Patented dual-layer T568A/B label with larger wiring diagrams
Patented Cone of Silence and metalized body to help suppress alien crosstalk (AXT)
Patented Retention Force Technology protects against damage from four- or six-pin plugs
Our component-rated UTP connectors add performance-enhancing features:
Patent-pending triple-stage compensation enhances margin performance and augments AXT suppression
Sharper Pair Separation Towers ease conductor separation
Conductor retention feature holds wires during termination
CAT 6A shielded connectors offer superior signal isolation and EMI/RFI protection, a 270 hinge for easy access, no punchdown tool needed, and snap-close cap when termination is complete.
Leviton Palm Termination Tool
Use Levitons Palm Termination Tool to quickly and easily punch down connectors at the jobsite. The Palm Tool offers an ergonomic comfort grip, increased connector stability, and integrated holes that allow rack mounting for QuickPort panel terminations.The Palm Tool is compatible with all CAT 6A/6/5e and standard QuickPort A/V connectors.
TER
MINAT
ION TIPS
CH. 6
TERMI-NATION
SPOTLIGHT
SPOTLIGHT
-
29
eXtreme CAT 6A 110-Style Patch Panel TerminationINST
RUCTIONS
CH. 6
TERMI-NATION Mount the eXtreme CAT 6A 110-Style Patch Panel to
a standard 19" equipment rack or wall-mount bracket, using the provided screws.
Determine which color-coded wiring scheme is desired (T568A or T568B).
NOTE: The color codes and port numbers are located on the panel labels between termination (IDC) slots.
Remove approximately 3" of the jacket and center spline/separator from cable.
Route jacketed wire to the termination field so that the jacket is centered near the IDCs (Figure A).
CAUTION: Use of mass termination impact tool is not permissible for this product.
Starting with the middle two pairs (orange/white and green/white) use your fingers to carefully seat and secure the wires into the IDC slots. Maintain wire pair twisting to within 1/2" of the IDC contact. Then position a 110-style impact tool (set to low impact) perpendicular to the IDC slot, seat and trim the cable.
NOTE: If wires appear to be bridged over the IDC, rather than securely seated into the slot, pull out the wires and reseat and repunch them (Figure B).
Once the CAT 6A module has been terminated, snap the 3-port retention cap to the back of the connector top and bottom sides. The retention cap can also be broken into single pieces (Figure C).
After the panel has been fully terminated, attach the cable management bar to the back of patch panel (Figure D).
1
2
3
5
4
6
-
30
leviton.co
m/cat6a
| 8
00.722
.208
2
INST
RUCTIONS
CH. 6
TERMI-NATION
A. B. C. D.
"Bridged" Wire Retention Dust Cap
Cable Management Bar
-
31
eXtreme CAT 6A Component- and Channel-Rated Connector TerminationINST
RUCTIONS
CH. 6
TERMI-NATION 1
2
3
5
4
T568A & T568B WIRING STANDARDS IDC COLOR ASSIGNMENTS
CONNECTOR PiN #
T568A WiRE COlORs
T568B WiRE COlORs
1 White/Green White/Orange
2 Green Orange
3 White/Orange White/Green
4 Blue Blue
5 White/Blue White/Blue
6 Orange Green
7 White/Brown White/Brown
8 Brown Brown
Remove about 3" of cable jacket and center spline (stiff plastic separator inside CAT 6A cable).
Determine whether to use wiring scheme T568A or T568B. Note the associated color codes and connector pin number on the label located between the IDC connector slots (Figure A). Peel back label for T568A wiring.
Leave the cable jacket within 1/8" of the connector side, then route the wires for termination using the selected wiring scheme (Figure B). Route cable perpendicular to the IDC field. Ensure there is enough slack in the twisted pairs, and do not place the cable jacket into the termination field.
Use your fingers to carefully seat wires into the IDC slots. Maintain wire pair twisting to within 1/2" of the IDC. Set a 110-style impact tool to low and position it perpendicular to the connector. Seat and trim the cable one pair at a time to prevent crushing the inside pairs (Figure C).
Place the Cone of Silence over the terminated wires for secure connection and guaranteed CAT 6A performance (Figure D).
-
32
leviton.co
m/cat6a
| 8
00.722
.208
2
INST
RUCTIONS
CH. 6
TERMI-NATION
eXtreme
CAT 6A
A.
eXtreme
CAT 6AeXtr
eme
CAT 6A
B. C. D.
-
33
CAT 6A Shielded Connector TerminationINST
RUCTIONS
CH. 6
TERMI-NATION Strip a minimum of 1.5" of jacket from the end of the
cable. For F/UTP cable, pull the foil or braided shield back over the jacket, and wrap the drain wire around the shield. For U/FTP cable, fold the foil from each twisted pair over the jacket and wrap the drain wire around the shield.
Insert the wires from the stripped cable into the stuffer cap through the hole (Figure A).
Determine whether to use wiring scheme T568A or T568B. Insert the wires into their correct positions per the desired wiring scheme (Figure B).
Using a flush cutter, cut the excess wire off as close to the edge of the cap as possible (Figure C). Wire tips should not protrude more than 1/32 of an inch.
1
2
3
5
4
6
Make sure that arrows on both connector and cap point in the same direction, align the cap with the IDC towers, and press into position. Rotate the cap wings toward each other until they snap closed (Figure D).
Ensure that the drain wire is wrapped around the cable and shield. Tie-wrap the drain wire to the shield. Do not over- tighten the tie wrap! It should be snug, but not so tight that it crushes the wires (Figure E).
-
34
leviton.co
m/cat6a
| 8
00.722
.208
2
INST
RUCTIONS
CH. 6
TERMI-NATION
AB
AB
B
A. B. C.
D. E.
-
CAT 6A TESTING7.
Field testing of CAT 6A installations is much like field testing for CAT 5e and CAT 6. However, CAT 6A testing is performed out to the higher frequency of 500 MHz. In addition, CAT 6A adds several tests for alien crosstalk (AXT).
-
36
leviton.co
m/cat6a
| 8
00.722
.208
2
PER
FORMANCE TES
TSCH. 7
CAT 6A TESTING
CAT 6A Performance Tests
Wire map
Length
Attenuation
Propagation delay
Delay skew
NEXT near-end crosstalk
PSNEXT power sum near-end crosstalk
FEXT far-end crosstalk
ELFEXT (ACRF) equal level far-end crosstalk (attenuation-to-crosstalk ratio, far-end)
PSELFEXT (PSACRF) power sum equal level far-end crosstalk (power sum attenuation-to-crosstalk ratio, far-end)
Return loss (RL)
PSFEXT power sum far-end crosstalk
PSACRF power sum attenuation-to-crosstalk ratio, far-end
AACRF alien attenuation-to-crosstalk ratio, far-end
AFEXT alien far-end crosstalk
ANEXT alien near-end crosstalk
PSAACRF power sum alien attenuation-to-crosstalk ratio, far-end
PSAFEXT power sum alien far-end crosstalk
PSANEXT power sum alien near-end crosstalk
Field Testing
Use an industry-recognized UL Level 4 field tester capable of testing to 500 MHz. Contact the test equipment manufacturer for any necessary hardware or software upgrades, including AXT testing capabilities, for testing CAT 6A installations. Perform permanent link or channel tests for all installed drops. Upon completion, provide the customer with all test results.
-
37
CH. 7
CAT 6A TESTING
AXT TES
TING
PSANEXT PSAACRF Leviton AXT Performance
Alien crosstalk (AXT) can have a serious impact on CAT 6A cabling system performance. Choose Leviton and get guaranteed AXT suppression. Independent 3rd-party and Leviton tests have proven that properly installed Leviton CAT 6A solutions have significant AXT headroom over the standards requirements, even for permanent links as short as 10 feet. As a result, properly installed Leviton systems with approved cable do not require field alien crosstalk testing. In addition, Leviton pre-terminated, pre-tested trunk cables do not require any field testing.
Independent (ETL) Test Results for Leviton Short Channel (30 ft.) CAT 6A System
SPOTLIGHT
Frequency (MHz): (Blue - Worst Case, Green - Average) Frequency (MHz): (Blue - Worst Case, Green - Average)
-
38
leviton.co
m/cat6a
| 8
00.722
.208
2
CH. 7
CAT 6A TESTING
AXT Testing Preparation
AXT testing measures the unwanted noise coupled to the cable being tested (called the Victim or Disturbed) by six surrounding cables (called Disturbers). Two tests need to be performed: The Power Sum Alien Near-end Crosstalk (PSANEXT) test and the Power Sum Alien Attenuation-to-Crosstalk Ratio, Far-end (PSAACRF) test. Results for the remaining AXT tests are taken as part of these two, so although they are not directly provided, a pass result for PSANEXT and PSAACRF ensures passing results for AACRF, AFEXT, ANEXT, and PSAFEXT. A 2% sample of the installed cables is typically recommended; testing the longest cables in the installation will provide the most meaningful results.
AXT tests are time-consuming! Budget AXT test time into your bid Handheld test instruments (field testers) require an adjunct AXT module A laptop computer is also typically used with the field tester The field testers AXT application software must be loaded onto the laptop Installation personnel will require training prior to performing AXT testing
AXT testing requires special planning, equipment and training:
AXT TES
TING
Is AXT Testing Required?
Even though Leviton does not require field AXT testing for its CAT 6A solutions, you may still be required to perform this testing. Read project specifications carefully to determine if they call for field AXT testing. If they do, ask for a waiver based on the proven performance of Levitons CAT 6A solutions. If the customer wont grant a waiver, youll need to perform the testing. Read the following AXT Testing Preparation section to gain a better understanding of field AXT testing requirements.
TEC
H TIP
-
PART NUMBERS8.
-
40
leviton.co
m/cat6a
| 8
00.722
.208
2
UTP PATCH PANELS
CH. 8
PARTNUMBERS
QUICKPORT PATCH PANELS
DESCRIPTION PART NO.
FLAT
1RU, 24-port, black connectors included 6910G-U24
1RU, 24-port, empty 49255-H24
1RU, 48-port, black connectors included 6910G-D48
2RU, 48-port, black connectors included 6910G-U48
2RU, 48-port, empty 49255-H48
2RU, 72-port, empty 49255-D72
ANGLED
1RU, 24-port, empty 49256-H24
1RU, 48-port, empty (for use with 6A10G CAT 6A connectors) 49256-D48
2RU, 48-port, empty 49256-H48
2RU, 72-port, empty 49256-D72
RECES
SED
ANGLED 1RU, 24-port, empty 4W256-H24
2RU, 48-port, empty 4W256-H48
2RU, 72-port, empty 4W256-D72
110-STYLE EXTREME 6A COMPONENT-RATED PATCH PANELS
DESCRIPTION PART NO.
Flat, 1RU, 24-port 6A586-U24
Flat, 2RU, 48-port 6A586-U48
Angled, 1RU, 24-port 6A587-U24
Angled, 2RU, 48-port 6A587-U48
C1 ULTRA COMPOSITE PATCH PANELS
QuickPort, flat, 2RU, 48-port, empty C1255-H48
VERTIGO ZERO-U PATCH PANELS
12-port, panel only, empty 49280-QP0
12-port with 3" channel, empty 49280-QP3
12-port with 6" channel, empty 49280-QP6
-
41
CONNECTORS
DESCRIPTION PART NO.
CAT 6A shielded 6S10G-S6A
PATCH CORDS
eXtreme CAT 6A component-rated SlimLine 6AS10-xx*
PATCH PANELS
QuickPort, flat, 1RU, 24-port, empty 4S255-S24
QuickPort, flat, 2RU, 48-port, empty 4S255-S48
QuickPort, angled, 1RU, 24-port, empty 4S256-S24
QuickPort, angled, 2RU, 48-port, empty 4S256-S48
UTP/SH
IELD
EDCH. 8
PARTNUMBERS
CONNECTORS
DESCRIPTION PART NO.
eXtreme 6A component-rated 6A10G-R6
eXtreme 6A channel-rated 6110G-R6
PATCH CORDS
eXtreme 6A component-rated SlimLine 6AS10-xx*
CROSS CONNECT
eXtreme 6A 110-style wiring block kit, with legs and C-4 clips, 64-pair
41D6A-1F4
UTP Shielded
xx = length: (03), (05), (07), (10), (15), or (20) feet.Custom length cords available, call inside sales at 800.722.2082 or +1.425.486.2222 for more information.
White (W) Yellow (Y) Red (R) Grey (S)Blue (l) Green (G) Black (E)Orange (O) Green (V) Blue (l)Purple (P)
Crimson (C)
Dark Red (R)
Orange (O) Yellow (Y)
Black (E)Grey (G)
Ivory (I)Almond (A)light Almond (T)
Brown (B)
White (W)
= Connector colors: Choose from any of the colors below.
* = Patch Cord colors: Choose from any of the colors below.
-
42
leviton.co
m/cat6a
| 8
00.722
.208
2
CABLE MANAGEM
ENT
CH. 8
PARTNUMBERS
VERSI-DUCT CABLE MANAGERS
DESCRIPTION FRONT ONLY FRONT & REAR8" X 8" CHANNEL 80" length, standard cover 8980L-VFO 8980L-VFR
80" length, designer cover 8C80L-VFO 8C80L-VFR
Center-mount bracket 89265-BKT
Slack loop organizer 89265-SL1
Cable retainer 89265-WR1
5" X 4"
CHANNEL
80" length, standard cover 4980L-VFO 4980L-VFR
40" length, standard cover 4940L-VFO 4940L-VFR
Center-mount bracket 49265-BKT
Designer cover, grey 59265-5DC
HORIzO
NTA
L
2RU, black cover 492RU-HFO 492RU-HFR
1RU, black cover 491RU-HFO 491RU-HFR
2RU designer cover, grey 49265-DC2
1RU designer cover, grey 49265-DC1
Cable retainer 49265-WR1
VELCRO BRAND FASTENERS
DESCRIPTION BLACK COLORS
5" tie wrap 43105-005 43105-05*
8" tie wrap 43108-008 43108-08*
12" tie wrap 43112-012 43112-12*
15' bulk roll 43115-015 43115-15*
75' bulk roll 43115-075 43115-75*
600' bulk roll 43115-600
15" compression strap 44115-15E 44115-15* (no maroon)
75' SoftCinch Lite roll 4S115-75E
See levitons full product catalog for more VElCRO Brand utility fastener part numbers.
leviton offers a wide variety of metal front and rear cable managers. Go online to leviton.com or see our full product catalog for the complete selection.
* = Colors: Choose from any of the colors below. Maroon fasteners are plenum-rated.
Maroon (P)Orange (O)Yellow (Y)Blue (L)
-
GLOSSARY9.
-
44
leviton.co
m/cat6a
| 8
00.722
.208
2
10GBASE-T (10 Gigabit baseband over twisted pair) This IEEE standard, 802.3an, defines 10 Gigabit Ethernet running 10Gbps over balanced twisted- pair cabling.
ANSI (American National Standards Institute) ANSI oversees the creation, circulation and use of standards and guidelines that directly impact businesses in various sectors. ANSI is also actively engaged in accrediting programs that assess conformance to standards.
Attenuation The loss of volume during transmission, or decrease in the power of a signal, light beam, or light wave. Attenuation is the opposite of gain and is measured in decibels (dB).
AWG (American wire gauge) is the standard measuring gauge for nonferrous conductors (i.e., non-iron and non-steel). Gauge measures the diameter of a conductor (thickness of cable).
AXT (alien crosstalk) is electromagnetic noise that can occur in a cable run alongside other signal-carrying cables. The term alien arises from the fact that this form of crosstalk occurs between different cables in a group or bundle, rather than between individual wires or circuits within a single cable.
Bandwidth The difference between the highest and the lowest frequencies of a transmission channel (path for information transmission). Identifies the amount of data that can be sent through a given channel. Measured in hertz (Hz); higher bandwidth numbers mean higher data capacity.
Bend Radius The amount of bend that can occur before a cable may sustain damage or increased attenuation.
BICSI (Building Industry Consulting Services International) is a non-profit professional association for the promotion of telecommunications industry standards.
Category 5e (enhanced category 5 or CAT 5e) is a standard for balanced twisted pair cable and components supporting signaling rates up to 100 MHz. CAT 5e is intended to support systems up to 1000BASE-T or Gigabit Ethernet up to distances of 100 m (328 ft).
Category 6 (CAT 6) is a standard for balanced twisted pair cable and components supporting signaling rates up to 250 MHz. CAT 6 is intended to support systems up to 1000BASE-T or Gigabit Ethernet up to distances of 100 m (328 ft).
Category 6A (augmented category 6 or CAT 6A) is a standard for balanced twisted pair cable and components supporting signaling rates up to 500 MHz. CAT 6A is designed to support 10GBASE-T or 10 Gigabit Ethernet up to distances of 100 m (328 ft).
Category of Performance Cabling and cabling component standards adopted by the telecommunications industry.
-
45
Channel In the horizontal cabling portion of a structured cabling system, the channel contains all of the elements of the permanent link, plus the equipment cords at the horizontal cross-connect (HC) and the patch cords in the work area.
Channel-rated Category-rated structured cabling components are said to be channel-rated if, when installed as a system in an industry-defined channel, they meet all of the transmission and noise characteristics defined in the standard. Compare with Component-rated.
Compliance A wiring device that meets all characteristics of a standard is said to be in compliance with that standard.
Component-rated Category-rated structured cabling components are said to be component-rated if they exceed all of the transmission and noise characteristics defined in the standard for an individual structured cabling component. Component
specifications are more stringent than channel specifications and may provide greater permanent link and channel test margins. Compare with Channel-rated.
Conductor Any substance, usually a wire or cable, that can carry an electrical current.
Connecting Block Also called a terminal block, punch-down block, quick-connect block, or cross-connect block, this plastic block contains metal wiring terminals to establish connections from one group of wires to another. Usually each wire can be connected to several other wires in a bus or common arrangement. There are several types of connecting blocks: 66, 110, etc.
Connector A device that connects wires or fibers in cable to equipment or other wires or fibers. Wire and optical connectors most often join transmission media to equipment or cross connects. Connectors are sometimes referred to as jacks; but although all
jacks are connectors, not all connectors are jacks.
Consolidation Point An optional location between an ER or TR and the workstation for interconnection of horizontal cables.
Data Center (DC) A data center is a facility used for housing a large amount of electronic equipment, typically servers, computers, data storage devices, and communications equipment. Data centers are designed to assure that the equipment and data housed in them are protected from environmental hazards and security breaches. Data centers can be private, serving a single company, or a public utility serving a variety of companies.
dB (decibel) A dB is a unit of measure of signal strength, usually the relationship between a transmitted signal and a standard signal source. Every 3dB equals 50% of signal strength, so therefore a 6dB loss is a loss of 75% of total signal strength.
-
46
leviton.co
m/cat6a
| 8
00.722
.208
2
EIA (Electronic Industries Alliance) The EIA is a trade organization made up of manufacturers that set standards for its member companies.
Ethernet leading local area network (lAN) protocol used for connecting computers, printers, workstations, terminals, etc. within the same building. Ethernet is a physical link and data link protocol that operates over twisted pair wire. See IEEE 802.3x.
ETL (Edison Testing laboratories) is an independent testing, inspection and certification laboratory owned by Intertek that provides electrical safety, electromagnetic compatibility, benchmark and performance testing. In addition, ETl issues two product safety marks: listed and verified.
ER (equipment room) is a centralized space that houses telecommunications equipment. ERs generally serve an entire building or campus, while TRs (telecommunication rooms) serve one floor of a building or a portion of a floor. An ER may contain active
equipment, cross-connect equipment, and building systems (e.g. life safety, security, electrical and HVAC).
FCC (Federal Communications Commission) The FCC is an independent United States government agency. It was established by the Communications Act of 1934 and is charged with regulating interstate and international communications by radio, television, wire, satellite and cable. The FCC's jurisdiction covers the 50 states, the District of Columbia, and U.S. possessions.
FTP (foiled twisted pair) is balanced twisted pair cable with an overall foil shield and drain wire. Also called screened twisted pair (ScTP) cable.
F/UTP (foiled screened with unshielded twisted pairs). Overall shielded cable with no shield on individual twisted pairs.
Gain An increase in signaling power when an electric device boosts the signal; measured in decibels (dB).
Gigabit When used to describe data transfer rates, Gigabit refers to 10 to the 9th power (1,000,000,000) bits. Gigabit Ethernet, abbreviated GbE, supports data transfer rates of 1 Gigabit (1,000 megabits) per second. The first Gigabit Ethernet standard (802.3z) was ratified by the IEEE 802.3 Committee in 1998.
HC (horizontal cross-connect) The HC is a location for the cross-connect of horizontal cabling to other cabling and equipment.
IC (intermediate cross-connect) The IC is a cross-connect point located between the MC (main cross-connect) and the HC in interbuilding backbone cabling.
IDC (insulation displacement connection) An IDC allows the termination of a conductor without stripping the conductors insulation. When the conductor is inserted into the contact, the insulation is displaced, creating contact between the conductor and the IDC, producing a gas-tight connection.
-
47
IEEE (Institute of Electrical and Electronics Engineers) is a publishing and standards-making body responsible for many standards used in lANs.
IEEE 802.3 is a collection of IEEE standards defining the physical layer and the media access control (MAC) sublayer of the data link layer of wired Ethernet. This is the most common local area network specification.
IEEE 802.3an is a standard for 10GBASE-T released in 2006 to provide 10 gigabit per second transmission over balanced twisted pair cables up to 100 meters (328 ft).
Impedance The total opposition (i.e. resistance and reactance) a circuit offers to the flow of alternating current. It is measured in ohms, and the lower the ohmic value, the better the quality of the conductor.
Insertion Loss (Il) The difference in the amount of power received before and after something is
inserted into the circuit.
Interconnect A circuit administration point, other than a cross-connect or an information outlet, that provides capability for routing and rerouting circuits. It does not use patch cords or jumper wires, and typically is a jack-and-plug device used in smaller distribution arrangements or that connects circuits in large cables to those in smaller cables.
ISO (International Standards Organization) is the world's largest developer and publisher of international standards. It is a non-governmental organization (NGO) network of national standards institutes in 157 countries, based in Geneva, Switzerland.
Jacket (also cable jacket or sheath) The outer covering applied over internal cable elements for protection.
LAN (local area network) A lAN is a computer network covering a small physical area, generally
a single building or contiguous campus. lANs are characterized by higher data-transfer rates (compared to a WAN or wide area network) and lack of leased telecommunications lines.
Mbps Megabits Per Second. One million bits per second.
MC (main cross-connect) The MC is the cross-connect in the ER (equipment room) for connecting entrance cables, backbone cables and equipment cables.
MHz (megahertz) is a unit of frequency denoting one million hertz (1,000,000 cycles per second).
Mud Ring Industry jargon for a plaster ring/frame mounted in a wall to support a telecommunications outlet such as a faceplate. Essentially, mud rings are backless junction boxes.
-
48
leviton.co
m/cat6a
| 8
00.722
.208
2
NEC (National Electric Code) The NEC or NFPA 70 (NFPA is the National Fire Protection Association, the organization that publishes the Code) addresses safeguards for people and property from electrical hazards. The NEC also specifies fire resistance and smoke ratings for building materials and is recognized and enforced in the United States. NEC article 800 addresses requirements for communications circuits.
NEXT (near-end crosstalk) Electrical noise coupled from one pair of wires to another within a multi-pair cable.
Part 68 Requirements specifications established by the FCC as the minimum acceptable protection communications equipment must provide the telephone network.
Patch Cord A cord made from 4-pair 100-ohm balanced twisted-pair cable. Patch cords may be shielded or unshielded, depending on the type of system being installed. They are typically wired T568
A or B with an 8-position, 8-conductor (8P8C) plug on each end. Work area and TR patch cords are made from stranded cable, which has better flexibility, durability and longer life than solid-conductor cords.
Patching A means of connecting circuits via cords and connectors that can be easily disconnected and reconnected at another point. May be accomplished by using modular cords connected between jack fields or by patch cord assemblies that plug onto connecting blocks.
Patch Panel A piece of connecting hardware designed for use in a standard 19" equipment rack or cabinet. Standard patch panels have modular jack appearances on the front, and 110-style IDC connections on the rear. Field-configurable patch panels can be loaded with a variety of jacks or other connectors for mixed-media installations, or where the use of various jack colors is desired.
Performance The totality of a communication transmissions characteristics, including rate of transfer, barriers to peak transfer rate, and comparison to applicable standards. Compare with Compliance. A device can exhibit performance characteristics without being compliant to an industry standard.
Permanent Link In the horizontal cabling portion of a structured cabling system, the permanent link contains the following: the telecommunications outlet (TO), the cabling between the horizontal cross-connect (HC) and the TO, an optional consolidation point (CP), and the connecting hardware at the HC.
Power Sum A test method for four-pair cable whereby the mathematical sum of pair-to-pair crosstalk from three pairs to one pair is measured.
-
49
Premises Telephony term for the space occupied by a customer or authorized/joint user in a building(s) on continuous or contiguous property (except railroad rights of way, etc.) not separated by a public road or highway. Frequently used as premises-based.
Premises Wiring System The entire wiring system on the users premises, especially the supporting wiring that connects the communications outlets to the network interface jack.
Punchdown Refers to the use of an impact tool that enables installers to make efficient IDC style connections.
RCDD (Registered Communications Distribution Designer) The RCDD title is a professional credential granted by BICSI. RCDDs have demonstrated a superior level of knowledge of Information Transport Systems (ITS) design and associated disciplines.
Return Loss (Rl) is a measure of the similarity of the impedance of a transmission line and the impedance at its terminations. It is a ratio, expressed in decibels, of the power of the outgoing signal to the power of the signal reflected back.
RJ (registered jack) RJs are telephone and data jacks registered with the FCC. Specific RJs, such as RJ-11 and RJ-45, are widely misused in the telecommunications industry. A much more accurate way to identify a jack is to specify the number of positions (width of opening) and number of conductors. Example: 8-position, 8-conductor (8P8C) jack or 6-position, 4-conductor (6P4C) jack.
RU (rack unit) is a unit of measure of vertical space in an equipment rack or cabinet. One rack unit is equal to 1.75 in (45 mm).
Standards Agreed-upon principles of performance. Standards are set by committees working under various trade and international organizations.
Structured Cabling System A structured cabling system (SCS) is defined as the complete collective configuration of cabling and associated hardware that has been installed at a given site to provide a comprehensive telecommunications infrastructure.
TDMM (Telecommunications Distribution Methods Manual). The TDMM is a publication from BICSI that is based on internationally accepted industry standards, codes and guidelines. The TDMM addresses the newest methodologies and recommends best practices for the design of structured cabling systems.
TE (Telecommunications Enclosure) Also referred to as a zone enclosure, a TE is a housing for telecommunications equipment, cable terminations, cross-connect cabling, and wireless access points. A TE serves the function of an horizontal cross-connect (HC) for a portion of a building floor and provides access to the buildings backbone and pathways. A TE should supplement, not replace, the requirement for a TR on a building floor.
-
50
leviton.co
m/cat6a
| 8
00.722
.208
2
TIA (Telecommunications Industry Association) The TIA is a trade organization of manufacturers which sets standards for use of its member companies. Formerly fell under the umbrella of EIA. See www.tiaonline.org.
TO (telecommunications outlet) is a connecting device in the work area on which horizontal cable terminates.
TR (telecommunications room) A TR is an architectural space that provides an environmentally suitable and secure area for housing cables, terminations, cross-connects, hardware and telecommunications equipment.
U/FTP also classified as STP (shielded twisted pair), is twisted pair cable with individually foil-screened twisted pairs, but no overall shield.
UL (Underwriters laboratories) is a privately owned product safety certification organization. Ul also certifies category-rated cable performance and quality.
UTP (unshielded twisted pair), also classified as U/UTP, is overall unshielded twisted pair with unshielded twisted pairs.
Work Area (WA) or workstation, is a building space where occupants interact with telecommunications terminal equipment.
WAN (wide area network) is a computer network that covers a broad geographic area. WANs connect lANs and other networks together. Some are private, but many are built by Internet service providers, who provide connection from organizational lANs to the Internet.
-
51
This guide has been developed consistent with all known applicable cabling practices as defined by the following:
TIA-568-C.0: Generic Telecommunications Cabling for Customer Premises (replaces applicable TIA 568-B standards)TIA-568-C.1: Commercial Building Telecommunications Cabling Standard (replaces applicable TIA 568-B standards)TIA-568-C.2: Telecommunications Cabling, Copper Component and Cabling Specifications (replaces applicable TIA 568-B standards) TIA-569-B: Commercial Building Standard for Telecommunications Pathways and SpacesTIA-606-A: Administration Standard for The Telecommunications Infrastructure of Commercial BuildingsTIA-942: Telecommunications Infrastructure Standard for Data CentersANSI-J-STD-607-A: Commercial Building Grounding and Bonding Requirements for TelecommunicationsIEEE 802.3: Ethernet-based lANs (multiple standards)IEEE 1100: Recommended Practice for Powering and Grounding Electronic EquipmentIntertek/ETL: Applicable verifications ISO 11801: Generic Cabling for Customer Premises (multiple standards)National Electrical Safety Code (NESC): Published by IEEENational Electric Code (NEC, NFPA 70): Published by NFPATelecommunications Distribution Methods Manual (TDMM): Published by BICSIUnderwriters Laboratories (UL): Applicable listings and ratings
Always follow superceding national, state, and local codes and regulations.
REF
EREN
CES
-
52
leviton.co
m/cat6a
| 8
00.722
.208
2
The following are trademarks of leviton Manufacturing Company, Inc:Acenti
C1 UltraCone of Silence
Decora
ExcellaeXtreme
QuickPort
Versi-Duct
VertiGO
Copyright leviton Manufacturing Co., Inc. 2010. All rights reserved. Any reproduction is forbidden without express written permission. Information in this guide is provided to assist in understanding CAT 6A structured cabling systems. All information contained herein is deemed accurate to the best of the companys knowledge at time of publication and is subject to change without notice.
For leviton warranty information, please visit leviton.com/warranties.
1
-
Leviton Corporate Headquarters 201 N service Road, Melville, NY 11747 UsA T 800.323.8920 / +1.631.812.6000 F 800.832.9538E [email protected]
Leviton International OfficesASEAN Countries T +65.98244468 F +65.94649592E [email protected]
South Korea T +82.2.3273.9963 F +82.2.3273.9962E [email protected]
Europe T +47.40.60.30.30 F +47.40.60.30.31E [email protected]
Australia & New Zealand T +64.4.562.8327 F +64.4.562.8327E [email protected]
Leviton Network Solutions Division Headquarters 2222 - 222nd st. s.E., Bothell, WA 98021-4422 UsA T 800.722.2082 / +1.425.486.2222 F 425.487.9486E [email protected]
l/9 - #2722
leviton.com/networksolutions
Leviton International Regional HeadquartersMiddle East (also serving Turkey and Africa)
T +971.4.886.4722 F +971.4.886.4723E [email protected]
China T +852.2774.9876 F +852.2774.1741E [email protected]
India / SAARC T +91.124.4356300 E [email protected]
Latin AmericaT +52.55.5082.1040 F +52.55.5386.1797E [email protected]
Canada T +1.514.954.1840 F +1.514.954.1853 E [email protected]