Ventura Lighting (Europe) - 1000 North Circular Road, London NW2 7JPWeb: www.venturalighting.co.uk Tel: +44 (0)20 8208 4081
COLUMNS & POLESTechnical Datasheets
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1
ROOT MOUNTED LIGHT DUTY
BRIT-R-LD Edition A Sheet 1/1
ROOT MOUNTED LIGHT DUTY
STEEL POLE - ROOT MOUNTED - TUBULAR - LIGHT DUTY - REMOVABLE ARM
Serial No
Model No
Height Bot. Dia
Bot. Height
Length Planted
Top Dia
Top Length
Door Opening
Door loc. above GL
Spigot Dia x Length
G I A F J E C x D B L x K
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-01 SRTLR040 4000 139.7 1250 800 76.1 2750 500x100 600 Nil
BRIT-02 SRTLR050 5000 139.7 1250 850 76.1 3750 500x100 600 Nil
BRIT-03 SRTLR060 6000 139.7 1250 1000 76.1 4750 500x100 600 Nil
BRIT-04 SRTLR070 7000 168.3 1400 1200 88.9 5600 600x115 650 76.1x200
BRIT-05 SRTLR080 8000 168.3 1400 1350 88.9 6600 600x115 650 76.1x200
BRIT-06 SRTLR090 9000 168.3 1600 1500 114.3 7400 600x115 850 101.6x250
BRIT-07 SRTLR010 10000 168.3 1600 1700 114.3 8400 600x115 850 101.6x250
BRIT-08 SRTLR011 11000 193.7 1750 1850 139.7 9250 600x115 1000 127x300
BRIT-09 SRTLR012 12000 193.7 1750 2000 139.7 10250 600x115 1000 127x300
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1
ROOT MOUNTED MEDIUM DUTY
BRIT-R-MD Edition A Sheet 1/1
STEEL POLE - ROOT MOUNTED - TUBULAR - MEDIUM DUTY - REMOVABLE ARM
Serial No
Model No
Height Bot. Dia
Bot. Height
Length Planted
Top Dia
Top Length
Door Opening
Door loc. above GL
Spigot Dia x Length
G I A F J E C x D1 B L x K
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-19 SRTMR040 4000 168.3 1250 800 76.1 2750 600x115 600 Nil
BRIT-20 SRTMR050 5000 168.3 1250 850 76.1 3750 600x115 600 Nil
BRIT-21 SRTMR060 6000 168.3 1250 1000 88.9 4750 600x115 600 76.1x200
BRIT-22 SRTMR070 7000 168.3 1400 1200 114.3 5600 600x115 650 101.6x250
BRIT-23 SRTMR080 8000 168.3 1400 1350 114.3 6600 600x115 650 101.6x250
BRIT-24 SRTMR090 9000 168.3 1600 1500 139.7 7400 600x115 850 127x300
BRIT-25 SRTMR010 10000 168.3 1600 1700 139.7 8400 600x115 850 127x300
BRIT-26 SRTMR011 11000 193.7 1750 1850 168.3 9250 600x115 1000 139.7x300
BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300
ROOT MOUNTED MEDIUM DUTY
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1
ROOT MOUNTED HEAVY DUTY
BRIT-R-HD Edition A Sheet 1/1
STEEL POLE - ROOT MOUNTED - TUBULAR - HEAVY DUTY - REMOVABLE ARM
Serial No
Model No
Height Bot. Dia
Bot. Height
Length Planted
Top Dia
Top Length
Door Opening
Door loc. above GL
Spigot Dia x Length
G I A F J E C x D B L x K
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-37 SRTHR040 4000 168.3 1250 800 114.3 2750 600x115 600 101.6x250
BRIT-38 SRTHR050 5000 168.3 1250 1000 114.3 3750 600x115 600 101.6x250
BRIT-39 SRTHR060 6000 168.3 1250 1200 114.3 4750 600x115 600 101.6x250
BRIT-40 SRTHR070 7000 193.7 1400 1400 114.3 5600 600x115 650 101.6x250
BRIT-41 SRTHR080 8000 193.7 1400 1600 114.3 6600 600x115 650 101.6x250
BRIT-42 SRTHR090 9000 193.7 1600 1800 139.7 7400 600x115 850 127x300
BRIT-43 SRTHR010 10000 193.7 1600 2000 139.7 8400 600x115 850 127x300
BRIT-44 SRTHR011 11000 219.1 1750 2200 168.3 9250 600x115 1000 139.7x300
BRIT-45 SRTHR012 12000 219.1 1750 2400 168.3 10250 600x115 1000 139.7x300
ROOT MOUNTED HEAVY DUTY
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1
BASE PLATE MOUNTED LIGHT DUTY
BRIT-B-LD Edition A Sheet 1/1
STEEL POLE - BASE PLATE MOUNTED - TUBULAR - LIGHT DUTY - REMOVABLE ARM
Serial No
Model No
Height Bot. Dia
Bot. Height
Bot. Thk.
Base Plate Top Dia
Top Thk.
Top Length
Door Opening
Door loc. above GL
Z O Y S x S x T R X U x V W
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-10 SBTLR040 4000 139.7 1250 4.5 280x280x12 76.1 3.2 2750 500x100 600
BRIT-11 SBTLR050 5000 139.7 1250 4.5 280x280x12 76.1 3.2 3750 500x100 600
BRIT-12 SBTLR060 6000 139.7 1250 4.5 280x280x12 76.1 3.2 4750 500x100 600
BRIT-13 SBTLR070 7000 168.3 1400 4.5 290x290x16 88.9 3.2 5600 600x115 650
BRIT-14 SBTLR080 8000 168.3 1400 4.5 290x290x16 88.9 3.2 6600 600x115 650
BRIT-15 SBTLR090 9000 168.3 1600 4.5 400x400x25 114.3 3.6 7400 600x115 850
BRIT-16 SBTLR010 10000 168.3 1600 4.5 400x400x25 114.3 3.6 8400 600x115 850
BRIT-17 SBTLR011 11000 193.7 1750 4.8 400x400x25 139.7 4.5 9250 600x115 1000
BRIT-18 SBTLR012 12000 193.7 1750 4.8 400x400x25 139.7 4.5 10250 600x115 1000
BASE PLATE MOUNTED LIGHT DUTY
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1
BASE PLATE MOUNTED MEDIUM DUTY
BRIT-B-MD Edition A Sheet 1/1
STEEL POLE - BASE PLATE MOUNTED - TUBULAR - MEDIUM DUTY - REMOVABLE ARM
Serial No
Model No
Height Bot. Dia
Bot. Height
Bot. Thk.
Base Plate Top Dia
Top Thk.
Top Length
Door Opening
Door loc. above GL
Z O Y S x S x T R X U x V W
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-28 SBTMR040 4000 168.3 1250 4.5 290x290x16 76.1 3.2 2750 600x115 600
BRIT-29 SBTMR050 5000 168.3 1250 4.5 290x290x16 76.1 3.2 3750 600x115 600
BRIT-30 SBTMR060 6000 168.3 1250 4.5 290x290x16 88.9 3.2 4750 600x115 600
BRIT-31 SBTMR070 7000 168.3 1400 4.5 400x400x25 114.3 3.6 5600 600x115 650
BRIT-32 SBTMR080 8000 168.3 1400 4.5 400x400x25 114.3 3.6 6600 600x115 650
BRIT-33 SBTMR090 9000 168.3 1600 4.5 400x400x25 139.7 4.5 7400 600x115 850
BRIT-34 SBTMR010 10000 168.3 1600 4.5 400x400x25 139.7 4.5 8400 600x115 850
BRIT-35 SBTMR011 11000 193.7 1750 4.5 400x400x25 168.3 4.5 9250 600x115 1000
BRIT-36 SBTMR012 12000 193.7 1750 4.5 400x400x25 168.3 4.5 10250 600x115 1000
BASE PLATE MOUNTED MEDIUM DUTY
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1
BASE PLATE MOUNTED HEAVY DUTY
BRIT-B-HD Edition A Sheet 1/1
STEEL POLE - BASE PLATE MOUNTED - TUBULAR - HEAVY DUTY - REMOVABLE ARM
Serial No
Model No
Height Bot. Dia
Bot. Height
Bot. Thk.
Base Plate Top Dia
Top Thk.
Top Length
Door Opening
Door loc. above GL
Z O Y S x S x T R X U x V W
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-46 SBTHR040 4000 168.3 1250 4.5 290x290x16 114.3 3.6 2750 600x115 600
BRIT-47 SBTHR050 5000 168.3 1250 4.5 290x290x16 114.3 3.6 3750 600x115 600
BRIT-48 SBTHR060 6000 168.3 1250 4.5 400x400x25 114.3 3.6 4750 600x115 600
BRIT-49 SBTHR070 7000 193.7 1400 4.5 400x400x25 114.3 3.6 5600 600x115 650
BRIT-50 SBTHR080 8000 193.7 1400 4.5 400x400x25 114.3 3.6 6600 600x115 650
BRIT-51 SBTHR090 9000 193.7 1600 4.5 400x400x25 139.7 4.5 7400 600x115 850
BRIT-52 SBTHR010 10000 193.7 1600 4.5 400x400x25 139.7 4.5 8400 600x115 850
BRIT-53 SBTHR011 11000 219.1 1750 4.8 510x510x30 168.3 4.5 9250 600x115 1000
BRIT-54 SBTHR012 12000 219.1 1750 4.8 510x510x30 168.3 4.5 10250 600x115 1000
BASE PLATE MOUNTED HEAVY DUTY
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 29/11/2014 Scale 1:1
6 METRE MID HINGED POLE
BRIT-6M-MH Edition A Sheet 1/1
APPLICABLE TOLERANCES
Height of pole <=10M ±1%
Height of pole >10M ±1.2%
Bracket projection length ±2%
Lantern fixing angle ±2°
Door opening & cable entry slot +10mm -0mm
Column circumference ±1%
Deviation in shape of circular cross section ±3%
Spigot length (vertical & angular) ±2mm
Dia. of lantern pipes EN 10210-2 Table 2 EN 10219-2 Table 2
Verticality 1°
Thickness EN 10051
Bracket & deviation ±5°
APPLICABLE STANDARDS
Design BS EN 40
Material (Steel) Column & Bracket EN 10025, EN 10149, EN 10210, EN 10219
Materials (Foundation Bolts) EN 10025 gr S 235 JR
Galvanising BS EN 1461
Protection (Door) EN 60529 - IP 3X
Impact Protection (Door) EN 50102 - IK08
Washers EN ISO 7093
Welding Process EN 1011-1, EN 1011-2
Welding Procedures EN 288-1, EN 288-2
Wind Actions EN 1991-1-4:2005 Eurocode 1 BS 6399
Inspection Documentation EN 10204
Visual Inspection (Welding) EN 571-1
6 METRE MID HINGED POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 29/11/2014 Scale 1:1
TAPERED OCTAGONAL SERIES
BRIT-XX-TO Edition A Sheet 1/1
STEEL POLE - BASE PLATE MOUNTED - TAPERED - OCTAGONAL - REMOVABLE ARM
Serial No
Model No
Height Top Dia
Bot. Dia
Base Plate Anchor Bolts Door Opening
Door loc. above GL
Y P T P x P x O W x V U
(mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-64 SBTOR040 4000 76 130 280x280x12 M16x500 - 4 Nos 300x85 500
BRIT-65 SBTOR050 5000 76 144 280x280x12 M16x500 - 4 Nos 300x85 500
BRIT-66 SBTOR060 6000 76 158 290x290x16 M20x500 - 4 Nos 300x85 500
BRIT-67 SBTOR070 7000 76 183 400x400x25 M24x600 - 4 Nos 600x115 500
BRIT-68 SBTOR080 8000 76 183 400x400x25 M24x600 - 4 Nos 600x115 600
BRIT-69 SBTOR090 9000 76 210 400x400x25 M24x600 - 4 Nos 600x115 600
BRIT-70 SBTOR010 10000 76 210 400x400x25 M24x600 - 4 Nos 600x115 600
BRIT-71 SBTOR011 11000 76 232 400x400x25 M24x600 - 4 Nos 600x115 600
BRIT-72 SBTOR012 12000 76 232 400x400x25 M24x600 - 4 Nos 600x115 600
STEEL POLE - ROOT MOUNTED - TAPERED - OCTAGONAL - REMOVABLE ARM
Serial No
Model No
Height Top Dia
Bot. Dia
Length Planted
Door Opening
Door loc. above GL
Cable Entry Slot Position below NGL
Cable Entry Slot
Size
I A E J H x G F D C x B
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
BRIT-55 SRTOR040 4000 76 130 600 300x85 500 350 150x50
BRIT-56 SRTOR050 5000 76 144 800 300x85 500 350 150x50
BRIT-57 SRTOR060 6000 76 158 1000 300x85 500 350 150x50
BRIT-58 SRTOR070 7000 76 183 1200 600x115 500 350 150x50
BRIT-59 SRTOR080 8000 76 183 1200 600x115 600 350 150x50
BRIT-60 SRTOR090 9000 76 210 1500 600x115 600 350 150x50
BRIT-61 SRTOR010 10000 76 210 1500 600x115 600 350 150x50
BRIT-62 SRTOR011 11000 76 232 1700 600x115 600 350 150x50
BRIT-63 SRTOR012 12000 76 232 1700 600x115 600 350 150x50
TAPERED OCTAGONAL SERIES
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
15 METER MONO POLE
BRIT-15M-M Edition A Sheet 1/1
A
B
C
D
E
Door at the top of the pole to accessTo secure cables complete with cable restraining bar
Brackets to suit soll ladder and fall arrest system on 700 centres
Top of pole capped, drilled and tapped to suit antenna fixing tube (tube dia to be confirmed) Cable exit holes to customers preference
Ladder brackets start 2-3 metres from ground level. Access made via removable ladder
Shaft constructed from heavy duty Ø273 circular hollow section
A
B
C
D
E
15 METRE MONO POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
CAMERA / FLOODLIGHTING HINGED POLE
BRIT-CF-H Edition A Sheet 1/1
The columns are designed to withstand wind speed of 50m/s, topography, ground roughness & statistical factor of 1.0
Columns are manufactured in compliance to British Standard BS 5649 / EN 40
Materials used for lighting columns are in compliance to EN 10025/JIS G3101 SS400
Lighting columns are longtitudenally seam welded conform to BS 5135 by automatic continuous metal inert gas (MIG) process
Columns are anti-corroded by hot-dip galvanising, compliance to galvanising standard BS 729 : 1971
Service door dimensions are given as a guide only. The engineer must satisfy himself that the dimension given is adequate for the installation of the required control gears
All dimensions are in mm unless otherwise specified
TECHNICAL SPECIFICATIONS
CAMERA / FLOODLIGHTING HINGED POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
CCTV CITY CENTRE POLE
BRIT-CC-CC Edition A Sheet 1/1
Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997
General Steelwork:BS 1449:1991, BS 1387:1985, BS EN 10025:1993
Welding Procedures:Comply with BS 5135:1994
Hot Dipped Galvanised:BS EN 729:1971, BS EN ISO 1461:1999
Fastners:Grade 8.8 BS 3692:2001, BS 4190:2001, DIN 931, DIN 934
Design Wind Loadings:Based on CP3 Chapter V Pt 2 (1972) & BS 6399 Pt 2 (1997)
Paint Finishes:BS 4800 & RAL colour range
MANUFACTURING STANDARDS
CITY CENTRE POLE - BASE PLATE MOUNTED
Serial No Height Pole Dia
Cabinet Height
Cabinet Size
Base Plate Thickness
Door Apperture
Weight
A B C D
(m) (mm) (mm) (mm2) (mm) (mm) (kg)
CCP3DD 3 168 1400 500 12 900(h)x300(w) 200
CCP4DD 4 168 1400 500 12 900(h)x300(w) 225
CCP5DD 5 168 1400 500 12 900(h)x300(w) 250
CCP6DD 6 168 1400 500 12 900(h)x300(w) 275
CCP7DD 7 168 1400 500 15 900(h)x300(w) 300
CCP8DD 8 168 1400 500 15 900(h)x300(w) 325
CCP9DD 9 219 1400 500 20 900(h)x300(w) 425
CCP10DD 10 219 1400 500 20 900(h)x300(w) 460
CCP11DD 11 219 1400 500 25 900(h)x300(w) 495
CCP12DD 12 219 1400 500 25 900(h)x300(w) 530
CCTV CITY CENTRE POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
CCTV FIXED SQUARE POLE
BRIT-CC-FS Edition A Sheet 1/1
Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997
General Steelwork:BS 1449:1991, BS 1387:1985, BS EN 10025:1993
Welding Procedures:Comply with BS 5135:1994
Hot Dipped Galvanised:BS EN 729:1971, BS EN ISO 1461:1999
Fastners:Grade 8.8 BS 3692:2001, BS 4190:2001, DIN 931, DIN 934
Design Wind Loadings:Based on CP3 Chapter V Pt 2 (1972) & BS 6399 Pt 2 (1997)
Paint Finishes:BS 4800 & RAL colour range
MANUFACTURING STANDARDS
FIXED SQUARE POLE - BASE PLATE MOUNTED
Serial No Height Pole Size
Gusset Thickness
Base Plate Thickness
Door Apperture
Weight
A B
(m) (mm2) (mm) (mm) (mm) (kg)
FSP3 3 100 6 12 400(h)x90(w) 100
FSP4 4 100 6 12 400(h)x90(w) 110
FSP5 5 120 6 12 400(h)x110(w) 130
FSP6 6 120 6 12 400(h)x110(w) 150
FSP7 7 120 8 15 400(h)x110(w) 225
FSP8 8 150 8 15 450(h)x130(w) 248
FSP9 9 150 10 20 450(h)x130(w) 359
FSP10 10 150 10 20 450(h)x130(w) 400
FSP11 11 200 15 25 500(h)x180(w) 425
FSP12 12 200 15 25 500(h)x180(w) 460
CCTV FIXED SQUARE POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
S C C TILT DOWN POLE
BRIT-SCC-TD Edition A Sheet 1/1
Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997
General Steelwork:BS 1449:1991, BS 1387:1985, BS EN 10025:1993
Welding Procedures:Comply with BS 5135:1994
Hot Dipped Galvanised:BS EN 729:1971, BS EN ISO 1461:1999
Fastners:Grade 8.8 BS 3692:2001, BS 4190:2001, DIN 931, DIN 934
Design Wind Loadings:Based on CP3 Chapter V Pt 2 (1972) & BS 6399 Pt 2 (1997)
Paint Finishes:BS 4800 & RAL colour range
MANUFACTURING STANDARDS
S C C TILT DOWN POLE - BASE PLATE MOUNTED
Serial No Height Pivot Height / Size
Lower Section /
Size
Upper Section /
Size
Extension Length /
Size
Gussett Thickness
Base Plate Thickness
Door Apperture
Rear TIlt Clearance
Weight
A B C D F
(m) (mm / mm2) (m / mm2) (m / mm2) (m / mm2) (mm) (mm) (mm) (mm) (kg)
SCC3TD 3 1500 / 200 3 / 120 N/A N/A 6 12 400(h)x100(w) 1500 165
SCC4TD 4 1500 / 200 3 / 120 1 / 100 N/A 6 12 400(h)x100(w) 1500 196
SCC5TD 5 1500 / 200 3 / 120 2 / 120 N/A 8 15 400(h)x120(w) 1500 281
SCC6TD 6 1500 / 200 3 / 200 3 / 150 N/A 10 20 400(h)x170(w) 1500 450
SCC7TD 7 2000 / 200 3 / 200 3 / 150 1 / 100 10 20 400(h)x170(w) 2000 500
SCC8TD 8 2000 / 200 3 / 200 3 / 150 2 / 100 10 20 400(h)x170(w) 2000 533
SCC9TD 9 2000 / 200 3 / 200 3 / 150 3 / 100 12 25 400(h)x170(w) 2000 566
SCC10TD 10 2000 / 200 4 / 200 3 / 150 3 / 100 12 25 400(h)x170(w) 2000 592
S C C TILT DOWN POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
CCTV VANDAL RESISTANT POLE
BRIT-CC-VR Edition A Sheet 1/1
This range protects against the following:
• Ramming by vehicles• Pole cabinet being torched• Pole shaft being cut• Camera theft• Camera attack by projectiles
Optional Extras:
• Double skin cabinet and shaft• Various anti-ram type bases available• Various decorative designs available• Anti-ladder brackets• Top pole cage• All poles can be painted to any RAL / BS colour• Anti-tamper switches can be fitted to doors• Anti-poster / graffiti / climb paints can be applied
CCTV VANDAL RESISTANT POLE
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
2 FIXED CAMERA & 1 PTZ BRACKET
BRIT-2FC-B Edition A Sheet 1/1
Camera adaptor to accept 2 x fixed cameras / 1 x PTZ cameras
The ACME BRIT-2FC-B bracket allows 2 x fixed cameras and 1 x PTZ camera to be mounted to our entire pole / tower range. Bracket fitted with 2 fully rotational swivel mounts to achieve the best camera position. (other uses) The standard 101.6PTZ fixing can be used to mount a dome swan neck type mount and the swivel bracket can be removed to fit lights.
Product:• Brackets fully cable managed for a tamper proof installation• Will fit to all ACME poles and towers• Fully galvanised for maximum weather protection• Painted to most RAL / BS colours• Fully rotational swivel mounts for camera positioning• Hole centres on mounting plate to suit most housings• Bracket is fitted to pole by standard 101.6PCD fixing
Camera Arm Length Upstands Available
A B
375mm 150 / 300 / 500
A A
B
2 FIXED CAMERA & 1 PTZ BRACKET
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
CCTV FIXED HOUSING BRACKET
BRIT-FH-B Edition A Sheet 1/1
Fixed housing bracket
Fixed wall mount brackets are the perfect solution to mount static cameras externally to brickwork, cladded type buildings. Fitted with a fully rotational swivel mount to position camera were required
Product:• Fully galvanised for maximum weather protection• Painted to most RAL / BS colours if required• Fitted with fully rotational swivel mounts to position camera housing where required• Customised outreach lengths available• Sleeved anchors can be supplied for wall fixing• CMA corner mount adaptors convert this bracket to corner mount
Camera Arm Length
A
350mm / 600mm
A
CCTV FIXED HOUSING BRACKET
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
DOME BRACKET CORNER MOUNT
BRIT-CM-DB Edition A Sheet 1/1
Dome bracket corner mount
These swept dome brackets are available to suit most dome manufacturers fixings. THese are manufactured with heavy duty fixings to suit brickwork, cladded buildings.
Product:• Fully galvanised for maximum weather protection• Painted to most RAL / BS colours if required• Fixings available to suit most manufacturers domes• Bracket is fitted to wall via 8 No 12mm holes• Various dome leg heights available
Product Code Swan Neck Outreach Swan Neck Height Corner Strap Length
A B C
SDBCM 500 700 400
A
C
BR250
DOME BRACKET CORNER MOUNT
VenturaThe Structural Steel Division Of LED Evolution
1 2 3 4
1 4
A
B
C
D
E
F
A
B
C
D
E
F
Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081
DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014
Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference
Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS
FOUNDATION FOR HINGED POLE
BRIT-F-H Edition A Sheet 1/1
Foundation Details
The below recommended foundation details are typical and some site conditions may require increased concrete base sizes. A minimum soil bearing of 75 n/m sq is assumed. We recommend pressures below the minimum are assessed by a structural engineer.
Product Code Height (m) Base Area (mm) Depth (mm) Concrete Vol (M2)
W x W D
VLIP3 3 1000 x 1000 500 0.5
VLIP4 4 1000 x 1000 750 0.75
VLIP5 5 1000 x 1000 750 0.75
VLIP6 6 1000 x 1000 1000 1
VLIP7 7 1200 x 1200 1000 1.44
VLIP8 8 1300 x 1300 1000 1.69
VLIP9 9 1400 x 1400 1000 1.96
VLIP10 10 1500 x 1500 1000 2.25
VLIP11 11 1700 x 1700 1200 3.46
VLIP12 12 1750 x 1750 1200 3.67
D
Template
65mm
Bolt Plates
Cable Duct
Concrete Base
W x W
1. Excavate hole as per recommended area and depth2. Assemble root base as shown in diagram 1 ensuring that it is level and that four studs protrude at 65mm above base of wooden setting template.3. Ensure ducting is in place (we recommend that a minimum of 150mm extrudes from ground level), if required this can be trimmed back once concrete is set.4. Pour concrete ensuring that it is a mix of M20 grade.5. Push template and bolts into concrete and level accordingly.6. When fitting the column, remove template and ensure that the concrete base is in complete contact with the underside of the column and torque the nuts to 230-270 Nm (175-200 ft/lb).7. When the column has been fitted, protect the studs with a suitable protective coating. Denzo tape or similar is recommended.8. After reinstatement it is essential that a load bearing grout is used to fill the void between base plate and concrete. Failure to do so may cause deflection in pole. It is recommended that the poles are grouted internally to ensure water tight.
Diagram 1Template Assembled
Diagram 2Foundation Cross Section
FOUNDATION FOR HINGED POLE
VenturaThe Structural Steel Division Of LED Evolution
VenturaThe Structural Steel Division Of LED Evolution
Ventura Lighting (Europe) - 1000 North Circular Road, London NW2 7JPWeb: www.venturalighting.co.uk Tel: +44 (0)20 8208 4081