Harmonized European standards for construction in Egypt
EN 1990 Eurocode :
Basis of Structural Design
Ratification : 29-11-2001Availability : 24-04-2002
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
3/108
Harmonized European standards for construction in Egypt
EN 1990: BASIS OF STRUCTURAL DESIGN
For the design of buildings and civil engineering worksevery Eurocode part from,
EN 1991:Eurocode 1: Actions on Structures, and
The design Eurocodes EN 1992 to EN 1999
has to be used together with EN 1990
EN 1990 provides the material independent informationrequired for the design of buildings and civilengineering works for the Eurocodes suite.
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
4/108
Harmonized European standards for construction in Egypt
EN 1990 : BASIS OF STRUCTURAL DESIGN:CONTENTS
ForewordSection 1 : General
Section 2 : RequirementsSection 3 : Principles of limit statesSection 4 : Basic variablesSection 5 : Structural analysis and design assisted by
testingSection 6 : Verification by the partial factor method
Annex A(n);(N): Application for buildings (1); bridges (2)Annex B (I): Management of structural reliability for constructionworksAnnex C (I): Basis for partial factor design and reliability analysisAnnex D (I): Design assisted by testing
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
5/108
Harmonized European standards for construction in Egypt
EN 1990 : BASIS OF STRUCTURAL DESIGN
Future Annexes
A2 (N) : Application for bridgesA3 (N) : Application for towers, masts and chimneysA4 (N) : Application for silos and tanksA5 (N) : Application for cranes and machinery
E1 (I ?) : Structural bearingsE2 (I ?) : Expansion jointsE3 (I ?) : Pedestrian parapetsE4 (I ?) : Vehicle parapets
E5 (I ?) : Ropes and cables
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
6/108
Harmonized European standards for construction in Egypt
EN 1990 is based on the
limit state concept
used in conjunction with the
partial factor method
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
7/108
Harmonized European standards for construction in Egypt
The limit state conceptThe limit state concept
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
8/108
Harmonized European standards for construction in Egypt
Objectives of EN 1990
EN 1990 describes the principlesandrequirementsfor the
Safety
Serviceability Durability
of structures
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
9/108
Harmonized European standards for construction in Egypt
The intended users of EN 1990 include
Designers and Constructors
Code drafting Committees
Public Authorities, (e.g. to set safetycriteria)
Clients
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
10/108
Harmonized European standards for construction in Egypt
SECTION 1 - GENERAL
1.1 Scope
1.2 Normative References
1.3 Assumptions
1.4 Distinction between Principles andApplication rules
1.5 Definitions
1.6 Symbols
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
11/108
Harmonized European standards for construction in Egypt
1.1 Scope
(1) EN 1990 establishes Principles and requirements for the safety,serviceability and durability of structures, describes the basis for theirdesign and verification and gives guidelines for related aspects ofstructural reliability.
(2) EN 1990 is intended to be used in conjunction with EN 1991 to EN1999 for the structural design of buildings and civil engineering works,including geotechnical aspects, structural fire design, situationsinvolving earthquakes, execution and temporary structures.NOTE For the design of special construction works (e.g. nuclear installations,
dams, etc.), other provisions than those in EN 1990 to EN 1999 might benecessary.
(3) EN 1990 is applicable for the design of structures where othermaterials or other actions outside the scope of EN 1991 to EN 1999 areinvolved.(4) EN 1990 is applicable for the structural appraisal of existingconstruction, in developing the design of repairs and alterations or inassessing changes of use.NOTE Additional or amended provisions might be necessary where appropriate.
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
12/108
Harmonized European standards for construction in Egypt
1.3 Assumptions(1) Design which employs the Principles and ApplicationRules is deemed to meet the requirements provided theassumptions given in EN 1990 to EN 1999 are satisfied (see
(2)).(2) The general assumptions of EN 1990 are :- the choice of the structural system and the design of thestructure is made by appropriately qualified and
experienced personnel;- execution is carried out by personnel having theappropriate skill and experience;- adequate supervision and quality control is provided indesign offices and during execution of the work, i.e.,factories, plants, and on site;
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
13/108
Harmonized European standards for construction in Egypt
1.3 Assumptions (cont.)the construction materials and products are used asspecified in EN 1990 or in EN 1991 to EN 1999 or in therelevant execution standards, or reference material or
product specifications;
the structure will be adequately maintained;
the structure will be used in accordance with the designassumptions.
NOTE There may be cases when the above assumptions need to besupplemented.
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
14/108
Harmonized European standards for construction in Egypt
1.4 Distinction between Principles and Application Rules The Principles (letter P) comprise :
general statements and definitions for which there is no alternative, aswell as
requirements and analytical models for which no alternative is permittedunless specifically stated.
It is permissible to use alternative design rules different from the applicationrules given in EN 1990, provided that it is shown that the alternative rulesaccord with the relevant principles and are at least equivalent with regard to
resistance, serviceability and durability which would be achieved for thestructure using Eurocodes.
NOTE If an alternative design rule is substituted for an application rule, theresulting design cannot be claimed to be wholly in accordance with EN 1990
although the design will remain in accordance with the Principles of EN1990. When EN 1990 is used in respect of a property listed in an Annex Z of aproduct standard or an ETAG, the use of an alternative design rule may notbe acceptable for CE marking.
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
15/108
Harmonized European standards for construction in Egypt
THE REQUIREMENTS
Basic requirements (safety;
serviceability; robustness and fire) Reliability differentiation
Design working life Durability
Quality Assurance
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
16/108
Harmonized European standards for construction in Egypt
BASICREQUIREMENTS
(Structural Reliability)
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
17/108
Harmonized European standards for construction in Egypt
in EN 1990 for the reliability ofconstruction works include :
Structural safety: A structure shallbe designed and executed in such a
way that it will, during its intended lifewith appropriate degrees of reliability,and in an economic way sustain allactions likely to occur duringexecution and use. Safety of people,the structure and contents.
Serviceability: A structure shall bedesigned and executed in such a waythat it will, during its intended life withappropriate degrees of reliability and inan economic way remain fit for the use
for which it is required. Functioning,comfort and appearance of thestructure
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
18/108
Harmonized European standards for construction in Egypt
Explosion atRonan Point1968
The fundamental requirementsin EN 1990 for the reliability ofconstruction works include :
Robustness: A structure shall bedesigned and executed in such a way
that it will not be damaged by events such as
Explosions Impact and Consequences of human errors
to an extent disproportionate to the originalcause
Note: The events to be taken into accountare those agreed for an individual projectwith the client and the relevant authority
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
19/108
Harmonized European standards for construction in Egypt
Limiting potential damage from identified hazards
Basic Requirements of EN 1990: Eurocode: Basis of StructuralDesign give principles for limiting potential damage by a number of
means including:
avoiding, eliminating or reducing a hazard
selecting a structural form which has a low sensitivity to the
considered hazard
using the most appropriate materials and products
various design options similar to current UK practice
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
20/108
Eurocodes and the Egyptian construction industry
EN 1990: BASIS OF STRUCTURAL DESIGN
Vehicle impacts (very severe)
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
21/108
Harmonized European standards for construction in Egypt
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
22/108
Harmonized European standards for construction in Egypt
THE REQUIREMENTS
Basic requirements (safety;
serviceability; robustness and fire) Reliability differentiation
Design working life Durability
Quality Assurance
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
23/108
Harmonized European standards for construction in Egypt
Reliability differentiation
An appropriate degree of reliability for themajority of structures is obtained by design andexecution according to Eurocodes 1 to 9, withappropriate quality assurance measures
EN 1990 provides guidance for obtaining
different levels of reliability
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
24/108
Harmonized European standards for construction in Egypt
The choice of the levels of reliability for a particularstructure should take account of the relevant factors,including :
the possible cause and /or mode of attaining a limit state ;
the possible consequences of failure in terms of risk to life,injury, potential economical losses ;
public perception to failure ;
the expense and procedures necessary to reduce the risk offailure.
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
25/108
Harmonized European standards for construction in Egypt
THE REQUIREMENTS
Basic requirements (safety;
serviceability; robustness and fire)
Reliability differentiation
Design working life
Durability
Quality Assurance
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
26/108
Harmonized European standards for construction in Egypt
The Basic Requirements for designworking life states :
The design working life is theassumed period for which astructure is to be used for its
intended purpose with anticipatedmaintenance but without majorrepair being necessary
a design working life of
50 years for buildings 100 years for bridgesis recommended.
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
27/108
Harmonized European standards for construction in Egypt
THE REQUIREMENTS Basic requirements (safety;
serviceability; robustness and fire) Reliability differentiation
Design working life Durability
Quality Assurance
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
28/108
Harmonized European standards for construction in Egypt
Durability It is an assumption in design that the
durability of a structure or part of it in its
environment is such that it remains fit for useduring the design working life givenappropriate maintenance
The structure should be designed in such away that deterioration should not impair thedurability and performance of the structurehaving due regard to the anticipated level ofmaintenance
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
29/108
Harmonized European standards for construction in Egypt
DurabilityInterrelated factors to be considered:
The intended and future use of the structure The required performance criteria
The expected environmental influences
The composition, properties andperformance of materials
The choice of structural system
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
30/108
Harmonized European standards for construction in Egypt
DurabilityInterrelated factors to be considered (cont)
The shape of members and structural detailing
The quality of workmanship and level of control
The particular protective measures
The maintenance during the intended life
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
31/108
Harmonized European standards for construction in Egypt
Quality Assurance and Quality Control
In order to provide a structure that corresponds to therequirements and to the assumptions made in the design,appropriate quality management measures should be in
place. These measures comprise :
definition of the reliability requirements,
organisational (e.g. company and individual
responsibilities) measures, and
controls at the stages of design, execution, use andmaintenance.
EN ISO 9001:2000 is an acceptable basis for qualitymanagement measures, where relevant.
EN 1990: BASIS OF STRUCTURAL DESIGN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
32/108
Harmonized European standards for construction in Egypt
EN 1991EN 1991 EUROCODE 1EUROCODE 1 ACTIONS ON STRUCTURESACTIONS ON STRUCTURES
EN 1991EN 1991--11--11 Densities, selfDensities, self--weight, imposed loadsweight, imposed loadsfor buildingsfor buildings
EN 1991EN 1991--11--22 Actions on structures exposed to fireActions on structures exposed to fire
EN 1991EN 1991--11--33 Snow loadsSnow loads
EN 1991EN 1991--11--44 Wind actionsWind actionsEN 1991EN 1991--11--55 Thermal actionsThermal actions
EN 1991EN 1991--11--66 Actions during executionActions during execution
EN 1991EN 1991--11--77 Accidental actionsAccidental actionsEN 1991EN 1991--22 Traffic loads on bridgesTraffic loads on bridges
EN 1991EN 1991--33 Actions induced by cranes andActions induced by cranes andmachinerymachinery
EN 1991EN 1991--44 Actions in silos and tanksActions in silos and tanks
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
33/108
Harmonized European standards for construction in Egypt
EN 1991EN 1991--11--11-- Imposed loadsImposed loads
ForewordForeword
Section 1 GeneralSection 1 General
Section 2 Classification of ActionsSection 2 Classification of Actions
Section 3 Design SituationsSection 3 Design Situations Section 4 Densities of Construction And Stored MaterialsSection 4 Densities of Construction And Stored Materials
Section 5 SelfSection 5 Self--weight of Construction Worksweight of Construction Works
Section 6 Imposed loads on BuildingsSection 6 Imposed loads on Buildings
Annex AAnnex A Tables For Nominal Density of ConstructionTables For Nominal Density of ConstructionMaterials, And Nominal Density And AnglesMaterials, And Nominal Density And Angles
of Repose For Stored Materials (I)of Repose For Stored Materials (I) Annex BAnnex B Vehicle Barriers And Parapets For Car Parks (I)Vehicle Barriers And Parapets For Car Parks (I)
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
34/108
Harmonized European standards for construction in Egypt
Main Categories of UseMain Categories of Use
Residential, social, commercial and administrationResidential, social, commercial and administrationareasareas
-- 44 categories (A, B, C and D)categories (A, B, C and D)
Areas for storage and industrial activitiesAreas for storage and industrial activities-- 22 categories (E1 and E2)categories (E1 and E2)
Garages and vehicle traffic (excluding bridges)Garages and vehicle traffic (excluding bridges)-- 22 categories (F and G)categories (F and G)
RoofsRoofs
--
33
categories (H, I and K)categories (H, I and K)
EN 1991EN 1991--11--11-- Imposed loadsImposed loads
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
35/108
Harmonized European standards for construction in Egypt
Table 6.2 Imposed loads on floors, balconies and stairs in buildingsCategories of loaded areas qk
[kN/m2]
Qk
[kN]Category A- Floors- Stairs- Balconies
Category B
Category C- C1- C2
- C3- C4- C5
Category D-D1
-D2
1,5 to 2,02,0 to 4,02,5 to 4,0
2,0 to 3,0
2,0 to 3,03,0 to 4,0
3,0 to 5,04,5 to 5,05,0 to 7,5
4,0 to 5,0
4,0 to 5,0
2,0 to 3,02,0 to 4,02,0 to 3,0
1, 5 to 4,5
3,0 to 4,02,5 to 7,0 (4,0)
4,0 to 7,03,5 to 7,03,5 to 4,5
3,5 to 7,0 (4,0)
3,5 to 7,0NOTE: Where a range is given in this table, the value may be set by the National annex. Therecommended values, intended for separate application, are underlined. qk is intended for thedetermination of general effects and Qk for local effects. The National annex may define differentconditions of use of this Table.
EN 1991EN 1991--11--11-- Imposed loads (example)Imposed loads (example)
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
36/108
Harmonized European standards for construction in Egypt
AA
A A m==== ++++ ====
5
7 1000
0
2
Exp (6.1) - Clause 6.3.1.2(10)
A (mA (m22)) AA (EN 1991(EN 1991--11--11
withwith oo = 0,7)= 0,7)AA (EN 1991(EN 1991--11--11
withwith oo = 1,0)= 1,0)
4040 0,750,75 0,960,96
8080 0,630,63 0,840,84
120120 0,590,59 0,800,80
160160 0,560,56 0,780,78
240240 0,540,54 0,760,76
EN 1991EN 1991--11--11-- Imposed loads (Reduction factor for floors)Imposed loads (Reduction factor for floors)
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
37/108
Harmonized European standards for construction in Egypt
2nn
)2n(2 0n >
+=
nn nn (EN 1991(EN 1991--11--1);1); = 0,7= 0,7
11 11
22 11
33 0,90,9
44 0,850,85
55 0,820,82
66 0,80,8
77 0,790,79
88 0,780,78
99 0,770,77
1010 0,760,76
EN 1991EN 1991--11--11-- Imposed loads (reduction factorImposed loads (reduction factor for imposed loadsfrom several storeys))
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
38/108
Harmonized European standards for construction in Egypt
Annex AAnnex A -- Nominal densities ofNominal densities ofconstruction and stored materialsconstruction and stored materials
Designated as anDesignated as an InformativeInformativeAnnexAnnex
12 tables:12 tables:-- 5 for construction materials (concrete/mortar, masonry,5 for construction materials (concrete/mortar, masonry,wood, metals andwood, metals and other materialsother materials););
-- 1 for bridge materials (asphalts, ballast, fills, railway1 for bridge materials (asphalts, ballast, fills, railwaysleepers);sleepers);
-- 1 for stored construction materials (aggregates, bentonite,1 for stored construction materials (aggregates, bentonite,gypsum and fresh water); andgypsum and fresh water); and
-- 5 for stored products (agricultural, foodstuffs, liquids, solid5 for stored products (agricultural, foodstuffs, liquids, solidfuels and industrial)fuels and industrial)
EN 1991EN 1991--11--11-- Imposed loadsImposed loads
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
39/108
Harmonized European standards for construction in Egypt
< 1 kW< 1 kW
WoodshedWoodshed0,6 m0,6 m22 -- 400 kW400 kW
FlameFlame20 kW20 kW
Layer fireLayer fire1 m1 m22 2 MW2 MW
EN 1991EN 1991--11--22-- Actions on structures exposed to fireActions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
40/108
Harmonized European standards for construction in Egypt
Car fireCar fire 10 m10 m22 8 MW8 MW
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991 11 2 Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
41/108
Harmonized European standards for construction in Egypt
Warehouse fireWarehouse fire 8000 m8000 m22 > 800 MW> 800 MW
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991 11 2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
42/108
Harmonized European standards for construction in Egypt
EUROPEAN HARMONISATIONCONSTRUCTION PRODUCT DIRECTIVE (1988-12-21)
ESSENTIAL REQUIREMENTS : Mechanical resistance and stability
Safety in case of fire
Hygiene, health and environment
Safety in use
Protection against noise
Energy, economy and heat retention
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991 11 2 A ti t t d t fi2 A ti t t d t fi
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
43/108
Harmonized European standards for construction in Egypt
ESSENTIAL REQUIREMENTSESSENTIAL REQUIREMENTSSAFETY in CASE of FIRESAFETY in CASE of FIRE
Concerning the construction work :Concerning the construction work : Load Bearing Capacity ... for a Specific Period of TimeLoad Bearing Capacity ... for a Specific Period of Time
The Generation and Spread of Fire and Smoke areThe Generation and Spread of Fire and Smoke are
limitedlimited The Spread of Fire to Neighbouring Construction isThe Spread of Fire to Neighbouring Construction is
limitedlimited
The Occupants can leave the Works or be rescuedThe Occupants can leave the Works or be rescued The Safety of Rescue Teams is taken into ConsiderationThe Safety of Rescue Teams is taken into Consideration
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991 11 2 A ti t t d t fi2 A ti t t d t fi
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
44/108
Harmonized European standards for construction in Egypt
HARMONISATION OFASSESSMENT METHODS
To prove compliance with Essential Requirements :
- tests
- calculation and/or design methods
- combination of tests and calculations
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
45/108
Harmonized European standards for construction in Egypt
THERMAL ACTIONSTHERMAL ACTIONS
MECHANICAL ACTIONSMECHANICAL ACTIONS
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
46/108
Harmonized European standards for construction in Egypt
THERMAL ACTIONS Nominal Time-Temperature Curves
Natural Fire Models
Simplified fire models
Advanced fire models
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
47/108
Harmonized European standards for construction in Egypt
0
300
600
900
1200
0 30 60 90 120 150 180 210
Temperature[C]
Time [min]
Standard time-temperature curve
Hydrocarbon fire
External fire
Nominal Time-Temperature Curves
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
48/108
Harmonized European standards for construction in Egypt
Compartment fire for internal elements 230 MJ/m299 pp
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
49/108
Harmonized European standards for construction in Egypt
Compartment Fires for external elementsCompartment Fires for external elements
EN 1991EN 1991-11-2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991 11 2 Actions on structures exposed to fire2 : Actions on structures exposed to fire
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
50/108
Harmonized European standards for construction in Egypt
BASIC PRINCIPLE
Load-bearing function of a structure
shall be assumed if :Ed,t, fi Rd,t, fi
where :
Ed,t, fi : design effect of actions (Eurocode 1 Part 1-2)
Rd,t, fi : design resistance of the structure at time t
EN 1991EN 1991--11--2 : Actions on structures exposed to fire2 : Actions on structures exposed to fire
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
51/108
Harmonized European standards for construction in Egypt
Background to Wind Action
Wind is highly turbulent and random in natureWind is highly turbulent and random in nature The fundamental equations of fluid motion areThe fundamental equations of fluid motion aredifficult to solvedifficult to solve
AllAll solutionssolutions for wind effects are onlyfor wind effects are only
approximationsapproximations
EN 1991 1 4 : Eurocode 1 Part 1 4 Wind actions
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
52/108
Harmonized European standards for construction in Egypt
Foreword
Section 1 GeneralSection 2 Design situations
Section 3 Modelling of wind actions
Section 4 Wind velocity and velocity pressure
Section 5 Wind actions
Section 6 Structural factor cscd
Section 7 Pressure and force coefficients
Section 8 Wind actions on bridges
Annex A (informative) Terrain effects
Annex B (informative) Procedure 1 for structural factor cscd
Annex C (informative) Procedure 2 for structural factor cscd
Annex D (informative) Graphs of cscd for common building formsAnnex E (informative) Vortex shedding & aeroelastic instabilities
Annex F (informative) Dynamic characteristics of structures
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
53/108
Harmonized European standards for construction in Egypt
Section 1 - GeneralSCOPESCOPE
Includes
Building and civil engineering works with heights up to 200m
Bridges with spans of less than 200m (subject to dynamic responsecriteria)
Excludes
Guyed masts and lattice towers (EN 1993-7-1) Lighting columns (EN40)
Cable supported bridges
Torsional and higher modes of vibration
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
54/108
Harmonized European standards for construction in Egypt
Section 4: Wind velocity and velocity pressureSection 4: Wind velocity and velocity pressureTerrain CategoriesTerrain Categories
Terrain category zo (m) zmin (m)0 Sea or coastal area exposed to the open sea
I. Lakes or flat and horizontal area with negligible vegetation and
without obstacles
II. Areas with low vegetation such as grass and isolated obstacles,
separated by at least 20 obstacle heightsIII. Areas with regular cover of vegetation or buildings or with
isolated obstacles separated by < 20 obstacle heights
IV. Areas in which at least 15% of the surface is covered with
buildings whose average height exceeds 15m
0.003
0.01
0.05
0.3
1.0
1
1
2
5
10
Terrain categories ( Annexe A)EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
55/108
Harmonized European standards for construction in Egypt
Category IICategory IIArea with lowArea with lowvegetation such asvegetation such asgrass and isolatedgrass and isolatedobstacles (trees,obstacles (trees,buildings) withbuildings) withseparations of atseparations of atleast 20 obstacleleast 20 obstacleheightsheights
Category IIICategory IIIArea with regularArea with regularcover ofcover ofvegetation orvegetation orbuildings or withbuildings or withisolated obstaclesisolated obstacleswith separations ofwith separations of
maximum 20maximum 20obstacle heightsobstacle heights(such as villages,(such as villages,suburban terrain,suburban terrain,permanent forest)permanent forest)
category IVcategory IVArea in which atArea in which atleast 15least 15 % of the% of thesurface is coveredsurface is coveredwith buildings andwith buildings andtheir averagetheir averageheight exceeds 15height exceeds 15
mm
Category 0Category 0Sea or coastalSea or coastalarea exposed toarea exposed tothe open seathe open sea
Category ICategory ILakes or flat andLakes or flat andhorizontal areahorizontal areawith negligiblewith negligiblevegetation andvegetation andwithoutwithout
obstaclesobstacles
-- Part 1Part 1--44 -- Wind actionsWind actions
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
56/108
Harmonized European standards for construction in Egypt
Section 4: Wind velocity and velocity pressure
Basic wind velocity vb = cdir cseason vb,0 cprobwhere vb,0 = 10 minute mean velocity at 10m above ground of category
II (z0 = 0.05)
cdir = directional factorcseason = seasonal factorcprob = probability factor
Mean wind velocity vm(z) = cr(z) co(z) vbWherecr(z) = roughness factor = kr ln(z/zo)kr = terrain factor depending on zoc
0(z) = orography factor
NationalNationalchoicechoiceallowedallowed
07,0
,0
019,0
====
II
rz
zk
5757EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions An exampleAn example
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
57/108
Harmonized European standards for construction in Egypt
Zone vb,0
(m/s)Zone 1 24,0
Zone 2 26,0
Zone 3 28,0
Zone 4 30,0
Zone 5
(Antilles, Runion)
34,0
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
58/108
Eurocodes and the Egyptian construction industry
Section 4: Wind velocity and velocity pressureSection 4: Wind velocity and velocity pressure
Peak velocity pressurePeak velocity pressure
==== )(2
1
)()(
2
zvzczq mep
wherewhereccee = exposure coefficient= exposure coefficient = air density (1,25 kN/m= air density (1,25 kN/m33))kkll = turbulence coefficient (generally 1,0)= turbulence coefficient (generally 1,0)
++++====
)(
71)()(
2
zc
kkzczc
r
rlre maxmin zzz
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
59/108
Harmonized European standards for construction in Egypt
Terraincategory
z0 (m) zmin (m)
0 0,003 1
I 0,01 1
II 0,05 2
III 0,3 5
IV 1,0 10
zzmaxmax = 200 m= 200 m
Terrain categoryTerrain categoryEN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
60/108
Harmonized European standards for construction in Egypt
z (m)Heightaboveground
ccee(z) exposure coefficient (without orography effect)(z) exposure coefficient (without orography effect)
Terrain categoryTerrain category
1 1.25 1.5 1.75 2 2.25 2.5 2.75 3 3.25 3.5 3.75 4 4.25 4.5
10
20
30
40
50
60
70
80
90
100IV III II I 0
EN 1991EN 1991--11--4 : Eurocode 14 : Eurocode 1 -- Part 1Part 1--44 -- Wind actionsWind actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
61/108
Harmonized European standards for construction in Egypt
Section5: Wind actions (bridges)5: Wind actions (bridges)
Wind pressure w = qp(ze) cp
Wind force Fw = cscd w Aref(using pressure coefficients)
Wind force Fw
= cs
cd
cf
qp
(ze
) Aref
(directly)
Wind force Fw = cscd cf qp(ze) Aref
(using vectorial summation)
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
62/108
Harmonized European standards for construction in Egypt
Eurocode 1: Actions on structuresEN 1991-1-5 General Actions
Thermal Actions
EN 1991-1-5: CONTENTS
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
63/108
Harmonized European standards for construction in Egypt
Section 1 General Section 2 Classification of actions Section 3 Design situations Section 4 Representation of actions
Section 5 Temperature changes in buildings Section 6 Temperature changes in bridges
Section 7 Temperature changes in industrial
chimneys, pipelines, silos, tanks andcooling towers Annexes
Changing the return period for transient design situations
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
64/108
Harmonized European standards for construction in Egypt
0. 4 0.5 0 .6 0 .7 0. 8 0.9 1 .0 1.1 1. 2 1.3
0,005
0,007
0,01
0,014
0,02
0,05
0,1
0,2
p m aximum minimum
Ratios
10years
50years
EN 1991-1-5: Representation of actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
65/108
Harmonized European standards for construction in Egypt
99 5 ep ese tat o o act o s
The temperature distribution within an individualstructural element is split into the following fouressential constituent components:
(a) A uniform temperature component,
Tu ;(b) A linearly varying temperature differencecomponent about the z-zaxis, TMy ;
(c) A linearly varying temperature differencecomponent about the y-yaxis, TMz ;
(d) A non-linear temperature difference component,TE. This results in a system of self-equilibratedstresses which produce no net load effect on theelement.
Diagrammatical representation of constituent
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
66/108
Harmonized European standards for construction in Egypt
Diagrammatical representation of constituent
components of a temperature profile
x
yyyyy
zzzzz
Center of
gravity
Tu TMy TMz TE
(a) (b) (c) (d)
= + + +
EN 1991-1-5: Temperature changes in buildings
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
67/108
Harmonized European standards for construction in Egypt
EN 1991-1-5: Temperature changes in buildings
Thermal actions on buildings due to climatic andoperational temperature changes need to be considered inthe design of buildings where there is a possibility of theultimate or serviceability limit states being exceeded due
to thermal movement and/or stresses.
Volume changes and/or stresses due to temperaturechanges may also be influenced by:
shading of adjacent buildings,
use of different materials with different thermal expansioncoefficients and heat transfer,
use of different shapes of cross-section with differentuniform temperature.
EN 1991-1-5: Temperature changes in buildings
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
68/108
Harmonized European standards for construction in Egypt
In accordance with the temperature components given,climatic and operational thermal actions on a structuralelement need to be specified using the following basicquantities:
A uniform temperature component Tu given by thedifference between the average temperature T of anelement and its initial temperature T0.
A linearly varying temperature component given by thedifference TM between the temperatures on the outer andinner surfaces of a cross section, or on the surfaces ofindividual layers.
A temperature difference Tp of different parts of astructure given by the difference of average temperaturesof these parts.
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
69/108
Harmonized European standards for construction in Egypt
Indicative values of inner environment (T1 and T2)And Tout (i.e.Tmax + T1,T2 or T3 ) for buildings above ground,
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
70/108
Harmonized European standards for construction in Egypt
T Season CharacteristicValues of thetemperature
(C)
CommentsCommentaires
1T Summer 20
2T Winter 25
3T
Summer
Relative absorption depends on surface colour.(bright light surface)0 Elements facing North-East
18 Elements facing South-West4T Relative absorption depends on surface colour.
(light coloured surface)2 Elements facing North-East30 Elements facing South-West
5T Relative absorption depends on surface colour.
(dark surface)4 Elements facing North-East42 Elements facing South-West
out ( max 1, 2 3 ) g g ,
for regions between latitudes 45o
N and 55o
N
Indicative temperatures Tout for underground parts of buildingsFor regions between latitudes 45oN and 55oN
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
71/108
Harmonized European standards for construction in Egypt
6T Summer 8 Temperature for depth below the groundlevel, less than 1 m.
7T Summer 5 Temperature for depth below the groundlevel, more than 1 m.
8T Winter -5 Temperature for depth below the groundlevel, less than 1 m.
9T Winter -3 Temperature for depth below the groundlevel, more than 1 m.
g
Thermal actions in bridge decksTemperature in girders
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
72/108
Harmonized European standards for construction in Egypt
TN produces a variation of length. It influences
The design of expansion joints
The design of bearingsIt produces action effects in statically undetermined structure
(portal bridges, arch bridges, etc.) and in continuous rails ofrailway bridges
TM produces a rotation in every cross-section In a statically determined girder
Deformation but no action effects In a statically undetermined girder
Deformation and action effects Horizontal component ( recommended value 5C)
TE
produces self-balanced stresses in the cross-section
BRIDGE TYPESBRIDGE TYPES
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
73/108
Harmonized European standards for construction in Egypt
Type 1 Steel deckType 1 Steel deck - steel boxsteel box--girdergirder
-- steel truss or plate girdersteel truss or plate girder
Type 2 Composite deckType 2 Composite deck
Type 3 Concrete deckType 3 Concrete deck
-- concrete slabconcrete slab-- concrete beamconcrete beam-- concrete boxconcrete box--girdergirder
TTe maxe max
Determination of thermal effectsDetermination of thermal effects
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
74/108
Harmonized European standards for construction in Egypt
e.maxe.max
TTe.mine.min
-50
-40
-30
-20
-10
0
10
20
30
40
50
60
70
-50 -40 -30 -20 -10 0 10 20 30 40 50
maximum
minimum
TTmaxmaxTTminmin
Type 1Type 1
Type 2Type 2Type 3Type 3
CONCRETE BRIDGECONCRETE BRIDGECorrelation betweenCorrelation between
minimum/maximumminimum/maximumshade airshade air
temperaturetemperature(Tmin/Tmax)(Tmin/Tmax)
AndAnd
minimum/maximumminimum/maximum
uniform bridgeuniform bridgetemperaturetemperaturecomponentcomponent(Te.min/Te.max)(Te.min/Te.max)
Table 6.1: Recommended values of linear temperature difference component fordifferent types of bridge decks for road, foot and railway bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
75/108
Harmonized European standards for construction in Egypt
Top warmer than bottom Bottom warmer than top
Type of Deck
TM,heat (oC) TM,cool (
oC)
Type 1:Steel deck 18 13
Type 2:Composite deck 15 18
Type 3:Concrete deck:- concrete box girder
- concrete beam- concrete slab
10
1515
5
88
NOTE 1: The values given in the table represent upper bound values of the linearlyvarying temperature difference component for representative sample of bridgegeometries.
NOTE 2: The values given in the table are based on a depth of surfacing of 50 mm
for road and railway bridges. For other depths of surfacing these values should bemultiplied by the factor ksur. Recommended values for the factor ksuris given inTable 6.2.
EN 1991-1-5 Thermal actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
76/108
Harmonized European standards for construction in Egypt
EN 1991-1-5 Thermal actions
Temperature differences for bridge decks : Type 1 Steel decksbridges (re-
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
77/108
Harmonized European standards for construction in Egypt
produced from EN 1991-1-5)
EN 1991-1-5 Thermal actionsTemperature differences for bridge decks : Type 2 Composite decksbridges (re-produced from EN 1991-1-5)
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
78/108
Harmonized European standards for construction in Egypt
bridges (re produced from EN 1991 1 5)
Temperature differences for bridge decks : Type 3 Concrete decksbridges (re-produced from EN 1991-1-5)
EN 1991-1-5 Thermal actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
79/108
Harmonized European standards for construction in Egypt
bridges (re produced from EN 1991 1 5)
Additional rulesAdditional rules
EN 1991-1-5 Thermal actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
80/108
Harmonized European standards for construction in Egypt
)()(75,0
)(35,0)(
,exp,,,
,exp,,,
conNNcoolMheatM
conNNcoolMheatM
TorTTorT
TorTTorT
++++
++++
Temperature differences between the inner and outer web walls oflarge concrete box girder bridges :Recommended value 15C
Differences in the uniform temperature component between differentstructural elements :- 15C between main structural elements (e.g. tie and arch); and- 10C and 20C for light and dark colour respectively between
suspension/stay cables and deck (or tower).
Simultaneity of uniform and temperature difference components
(recommended values)
Temperature differences between the outer faces of bridge piers,hollow or solid
EN 1991-1-5 Thermal actions
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
81/108
Harmonized European standards for construction in Egypt
55CC
1515CC
Bridge axisBridge axis
Design of Bridges with Eurocodes
EN1990 + Annex A2
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
82/108
Harmonized European standards for construction in Egypt
EN 1991-1-/1, 3, 4, 5, 6, 7EN 1991-2 : Traffic loads
EN 1992-1+2 : concrete bridgesEN 1993-1+2 : steel bridgesEN 1994-1+2 : composite bridgesEN 1995-1+2 : timber bridges
EN 1997-1 : foundationsEN 1998-1+2+5 : bridges in seismic zones
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
83/108
Harmonized European standards for construction in Egypt
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
84/108
Harmonized European standards for construction in Egypt
EN 1991-2Eurocode 1 :
Actions onstructures Part 2:Traffic Loadson Bridges
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
85/108
Harmonized European standards for construction in Egypt
FOREWORD
SECTION 1 GENERAL
SECTION 2 CLASSIFICATION OF ACTIONS
SECTION 3 DESIGN SITUATIONS
SECTION 4 ROAD TRAFFIC ACTIONS AND OTHER ACTIONSSPECIFICALLY FOR ROAD BRIDGES
SECTION 5 ACTIONS ON FOOTWAYS, CYCLE TRACKSAND FOOTBRIDGES
SECTION 6 RAIL TRAFFIC ACTIONS AND OTHER ACTIONS
SPECIFICALLY FOR RAILWAY BRIDGES
ANNEX A (I) Models of special vehicles for road bridges
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
86/108
Harmonized European standards for construction in Egypt
ANNEX B (I) Fatigue life assessment for road bridges Assessmentmethod based on recorded traffic
ANNEX C (N) Dynamic factors 1+ for real trains
ANNEX D (N) Basis for the fatigue assessment of railway structures
ANNEX E (I) Limits of validity of load model HSLM and the selectionof the critical universal train from HSLM-A
ANNEX F (I) Criteria to be satisfied if a dynamic analysis is not
requiredANNEX G (I) Method for determining the combined response of a
structure and track to variable actions
Annex H (I) Load models for rail traffic loads in transient situations
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
87/108
Harmonized European standards for construction in Egypt
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
88/108
Harmonized European standards for construction in Egypt
Traffic load models for road bridgesTraffic load models for road bridges
-- Vertical forces : LM1, LM2, LM3, LM4Vertical forces : LM1, LM2, LM3, LM4-- Horizontal forces : braking and acceleration,Horizontal forces : braking and acceleration,
centrifugal, transversecentrifugal, transverse
Groups of loadsGroups of loads
-- gr1a, gr1b, gr2, gr3, gr4, gr5gr1a, gr1b, gr2, gr3, gr4, gr5-- characteristic, frequent and quasicharacteristic, frequent and quasi--permanentpermanentvaluesvalues
Combination with actions other than traffricactions
LOAD MODEL FOR LIMIT STATES OTHER THAN FATIGUE LIMIT
STATES
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
89/108
Harmonized European standards for construction in Egypt
STATES Field of application : loaded lengths less than 200 m (maximum
length taken into account for the calibration of the Eurocode Forvery long loaded lengths, see National Annex)
Load Model Nr. 1Concentrated and distributed loads (main model)
Load Model Nr. 2
Single axle load
Load Model Nr. 3Set of special vehicles
Load Model Nr. 4Crowd loading : 5 kN/m2
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
90/108
Harmonized European standards for construction in Egypt
The main load model (LM1)The main load model (LM1)
qq1k1k = 9 kN/m= 9 kN/m22
qq2k2k = 2,5 kN/m= 2,5 kN/m22
qq3k3k = 2,5 kN/m= 2,5 kN/m22
qqrkrk = 2,5 kN/m= 2,5 kN/m22
Load model Nr 2 (LM2)
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
91/108
Harmonized European standards for construction in Egypt
Load model Nr. 2 (LM2)
1QQ ====
Recommended
value :
(0,9 for the(0,9 for the 2nd
class)class)
Fatigue Load Models for road bridges
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
92/108
Harmonized European standards for construction in Egypt
Fatigue Load Models for road bridges
Load Model Nr. 1 (FLM1) : Similar to characteristic Load
Model Nr. 10,7 x Qik - 0,3 x qik - 0,3 x qrk
Load Model Nr. 2 (FLM2) : Set of fequent lorries Load Model Nr. 3 (FLM3) : Single vehicle
Load Model Nr. 4 (FLM4) : Set of equivalent lorries Load M/odel Nr. 5 (FLM5) : Recorded traffic
Fatigue Load Model Nr.3 (FLM3)
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
93/108
Harmonized European standards for construction in Egypt
EN 1991-2 - Traffic loads on bridges
Load models for footbridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
94/108
Harmonized European standards for construction in Egypt
LOAD MODEL Nr.1Uniformly distributed load qfk
LOAD MODEL Nr.2Concentrated load Qfwk(10 kN recommended)
LOAD MODEL Nr.3Service vehicle Q
serv
Recommended characteristic value for :- footways and cycle tracks on road bridges,
- short or medium span length footbridges :
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
95/108
Harmonized European standards for construction in Egypt
- short or medium span length footbridges :
Recommended expression for long span length
footbridges :
L is the loaded length [m]
2
fk kN/m30
1200,2
++++++++====L
q
2
fk kN/m5,2q
2
fk kN/m0,5====q
2
fk kN/m0,5q
Railway bridges - Notation and dimensions
specifically for rail tracks Section 6
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
96/108
Harmonized European standards for construction in Egypt
(1) Running surface(2) Longitudinal forces acting along the centreline of the track
specifically for rail tracks Section 6
s : Gaugeu : CantQs : Nosing force
Load Model LM 71
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
97/108
Harmonized European standards for construction in Egypt
The characteristic values may be adjusted to the expected traffic onthe bridge by a multiplication factor which shall be one of thefollowing :
0,75 - 0,83 - 0,91 - 1,00 - 1,10 - 1,21 - 1,33 1,46
1,33 is the recommended value for important and international lines.When selected, the same factor shall be applied to the other rail
traffic action components, in particular to centrifugal forces, nosingforces, and acceleration and braking.
Load Models SW/0 and SW/2
(H il ffi )
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
98/108
Harmonized European standards for construction in Egypt
Loadmodels qvk[kN/m] a[m] c[m]
SW/0
SW/2
133
150
15,0
25,0
5,3
7,0
(Heavy rail traffic)
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
99/108
Harmonized European standards for construction in Egypt
Example of a heavy weight waggon (DB, 32 axles, selfweight 246 t,
pay load 457 t, mass per axle 22 t , Ltot = 63,3 m
Models HSLM-A et HSLM-B for international high
speed lines
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
100/108
Harmonized European standards for construction in Egypt
speed lines
Stresses and strains in a bridge deck due to rail traffic (including the
Dynamic effects
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
101/108
Harmonized European standards for construction in Egypt
Stresses and strains in a bridge deck due to rail traffic (including theassociated acceleration) are amplified or reduced by the followingphenomena :
- Loading celerity due to the speed of rail traffic crossing the bridgeand the bridge inertia,
- Successive loads crossing the bridge with more or less regularspacings, which can excite the structure and, in some cases, lead toresonance,
- Variations of wheel loads due to imperfection of tracks or of thevehicle (including wheel irregularities).
To cover these effects, EN 1991-2 defines 3 dynamic amplification
factors
Maximum permissible vertical deflection for railway bridges with 3 ormore successive simply supported spans corresponding to a
permissible vertical acceleration of bv = 1 m/s in a coach for speed V[k /h]
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
102/108
Harmonized European standards for construction in Egypt102
v[km/h]
Fatigue Example of light train (type 1) for fatigue
verifications
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
103/108
Harmonized European standards for construction in Egypt
Traction and braking forces act at the top of the rails in the longitudinaldirection of the track. They shall be considered as uniformly distributed over
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
104/108
Harmonized European standards for construction in Egypt
y ythe corresponding influence length La,b for traction and braking effects for thestructural element considered. The direction of the traction and braking forcesshall take account of the permitted direction(s) of travel on each track. Their
characteristic value is given in the Table below :Traction force Qlak = 33 [kN/m] La,b [m] 1000 [kN]
For Load Models LM 71, LM SW/0, LM SW/2 etHSLM
Braking force Qlbk = 20 [kN/m] La,b[m] 6000 [kN]
For Load Models LM 71, LM SW/0 et HSLM
Qlbk = 35 [kN/m] La,b [m]
For Load Model LM SW/2
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
105/108
Harmonized European standards for construction in Egypt
(1) max. 1,5s or less if against wall
(2) Track gauge s
(3) For ballasted decks the point forces may
be assumed to be distributed on a squareof side 450mm at the top of the deck.
Design situation I Equivalent loads QA1dand qA1d
(1) Load acting on edge of structure
(2) Track gauge s
Design Situation II - equivalentload qA2d
Aerodynamiceffects as a result
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
106/108
Harmonized European standards for construction in Egypt
of passing trains
Examples ofcharacteristicvalues ofpressure q1k for
simple verticalsurfaces parallelto the track
Combined response of structure and track to variableCombined response of structure and track to variable
actionsactionsThe effects resulting from the combined response of the structurThe effects resulting from the combined response of the structure ande and
EN 1991-2 - Traffic loads on bridges
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
107/108
Harmonized European standards for construction in Egypt
g pg pthe track to variable actions shall be taken into account for ththe track to variable actions shall be taken into account for the designe designof the bridge superstructure, fixed bearings, the substructure aof the bridge superstructure, fixed bearings, the substructure and fornd forchecking load effects in the rails. Traction and braking forces,checking load effects in the rails. Traction and braking forces, thermalthermal
actions, effects of vertical loads due to traffic (the associateactions, effects of vertical loads due to traffic (the associate
d dynamicd dynamic
effects may be neglected) shall be taken into account for theeffects may be neglected) shall be taken into account for thedetermination of the response. The use of the following model isdetermination of the response. The use of the following model isrecommended.recommended.
108
-
7/29/2019 20110127 Eurocodes Egypt Work Calgaro EC0 and EC1.pdf
108/108
Harmonized European standards for construction in Egypt