1
SAFECOM & HTC Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries
US PATENT 8,415,822US PATENT 5,747,888
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mai l [email protected]
2
Hulda transformers Company Profile: Established in 1975 and is owned by Kibbutz Hulda. A part of (KIA) the Kibbutz Industries Association represented over 300
factories & Companies owned by the kibbutz association in Israel It total KIA has 35,000 employees & over 8 billons US$ sales/year.
3
Main Markets : Military & Aviation transformers. Medical equipment manufacture. Cable TV industry.
Safety standard :CE, BABT, IEC, VDE & UL
Quality Assurance Management System :ISO 9001:2008 certified.
Hulda transformers Company
4
Mr David ZilberbergPrivet company
Hulda transformers Company
Kibbutz Industries Association (KIA)
Kibbutz Organization
CATV Upstream noise blocker (UNB)
CATV Patented Powering
Kibbutz Hulda
5
Safecom's proven patented SYNERGY-2 , DPSV4, Power Booster & Dual T-former P.S turns existing CATV networks into a super power synergy platform that provide most reliable and economic powering system for unlimited backup time.
Safecom Smart Grid Patented technology providing complete set of unlimited backup Power for CATV networks & Without Batteries
DPS v5
Power Booster 5G
SYNERGY-2
Dual T-former 2X 15A 60,66,72,87 V +
DOCSIS Monitoring
6
Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the SYNERGY-2 & DPS4 draws power from the distant available source over existing coax or power cables. Utilizing breakthrough direct AC/AC On-Line stabilize technology safecom's SYNERGY-2 and Power Booster ensures an optimal voltage level – even over long distances.
The Backup Power concept .
7
Based on the strategic placing of intelligent power management devices throughout the network, in the event of a power outage the DPSv4 draws power from the nearest available source over existing coax or power cables.
Safecom's proven smart grid technologies greatly improve network powering reliability while creating significant savings on both capital and operational expenses.
1 2
3 4Power +
Signal
To remote / Node / Amplifier
Optical Node/Trunk
amp
P.S
2
1
3
4
AC 1 input .AC 2 input
Local output to local Optical Node.(AC+RF) Backup IN.OUT (AC+RF to remote Node/ amp)
DPS V5US PATENT 5747888 EP 0708559
Power Booster
Port
Monitoring Port: voltage,
RF PASS 5-1000 MHZ
AC 1
Local Remote
Current, status
AC 2
8
MINIMIZE THE NUMBER OF POWER SUPPLIES IN THE NETWORK. INCREASING THE POWERING AREA COVERED BY POWER SUPPLY
POWER BOOSTER US PATENT 8,415,822
Utilizing patented breakthrough direct on-line zero crossing AC/AC stabilize technology safecom's ensures an optimal voltage level to Optical Nodes & Line Amplifiers even the source of power from over long distances. Passive , Standalone element , power booster solves the power distribution problem in a CATV network caused by high-resistance and low energy efficient coax & electricity cables.
Vin 30-87Vac (US)Vin 30-64Vac (EU)
tv
tv
Vout 87 Vac (US) Vout 60 Vac (EU)
RF PASS 5-1000 MHZ
9
Power Booster – the 5G Transmission New Power Booster 4 active gears + Bypass.
Integrated Dual Power inserter. Stand alone unit.
RF PASS 1GHZ
Voltage gain 1: 1.56 enabling up to double powering distance.
coverage area
Zero crossing Patented Technolgy - Smooth transition between conversion
levels.Technology
4 Automatic gears + Bypass. AC/AC transformation
gears
100 mA (EU model) 200 mA (US model)
Self current load
10
• All in One two-way RF Pass 1GHZ passive device that “toggle” available power between two distant locations.• Redirecting power from the "normally" remote powered area to the area subject to power outage.• During the normal mode of operation, when there is no power outage at either end of the pair, the SYNERGY-2 act as power block to the other side. • Utilizing breakthrough step-up & stabilizing voltage technology the unit provides optimal & stable voltage level from local or remote P.S even from very long distance or using a un-stabilized P.S.
=DPS V 5
Power Booster
SYNERGY-2US PATENT 8,415,822
AC 1 input .AC 2 input Local output to local Optical Node.(AC+RF)
Backup IN.OUT (AC+RF to remote Node/ amp) 12
34
Power +
Signal
To remote / Node / Amplifier
Optical Node/Trunk
amp
P.S
21
3 4
+
The New Powering generation.
11
Inputs/ Outputs configuration
Monitoring Inputs/outputs
ONLINE Current & Voltage +
status .
AC 2 - Input AC1 - Input
RF / AC 5-1000MHz 15A OUTPUT To Local Amplifier / Node
RF / AC 5-1000Mhz 15AINPUT / OUTPUTTo / From Remote Amplifier / Node
US PATENT 8,415,822
Vin 30-87V Vac (US)Vin 30-64V Vac (EU)
t
v
tv
Vout 87 Vac (US)Vout 60 Vac (EU)
• Inside view : SYNERGY-2 60/87V -2x15A
12
US PATENT 8,415,822Dual Port P.S + Docsis / EuroDOCSIS monitoring
NEW UR – Ultra Range +/- 25% Vin
Power Innovation
aa aaa
a
13
DOCSIS® & EuroDOCSIS Status Monitoring Embedded Transponder.
Direct RF connection to CATV network
Output 260,66,72 15A
Output 160,66,72 15A
External Monitoring DPS, SYNERGY-2 & more
Dual Port P.S model SC-D-TFPS-2200-U-O-M2 ports X 15A 60,75,87Vac 50/60 Hz .
Direct connection .
Direct connection .
Voltage testing points
Current loop testing points
(For Clamp meter )
14
NEW-Dual Port P.S model SC-D-TFPS-2200-UO-M-D-S2 ports X 15A 60,75,87Vac 50/60 Hz .
15
Direct RF connection to CATV network
Output 260,66,72 15A
External Monitoring DPS, SYNERGY-2 & more
NEW-Dual Port P.S model SC-D-TFPS-2200-UOM2 ports X 15A 60,75,87Vac 50/60 Hz .
Direct connection .
Output 160,66,72 15A
Direct connection .
Voltage testing points
Current testing points
Secondary AC input / Generator
Main AC input
2 x 25A Phase changer
140 KA SURGE SUPPRESSION
DOCSIS® & EuroDOCSIS Status Monitoring Embedded Transponder.
16
SYNERGY-2 Typical configuration Optical node + Trunk amplifier(or second optical node) .
Power + Signal
From Optical node 4
21
3
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
Optical Node21
3 4To remote / amplifier / Node P.S
.S
P.S
87V
87V
Trunk amplifierOr Optical Node
87V87V
Area A
Area B
The New Powering generation.
17
From Optical node
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
Optical Node21
3 4To remote / amplifier / Node P.S
.S
P.S
SYNERGY-2 – Demo backup power from Area A to Area B
Power + Signal Trunk amplifierOr Optical Node
87V79V71V
63V87V
Area A
Area B
21
43340V 60V
55V 87V
18
Power + Signal
To Optical node4
21
3
1234
AC 2 input .AC 2 input
Local output to local Optical Node.(AC+RF)Backup IN.OUT (AC+RF to remote Node/ amp)
Power + Signal
21
3 4From remote amplifier / Node
P.S.S
P.S
Optical Node
63V71V
79V
87V 87VTrunk amplifierOr Optical Node
SYNERGY-2 – Demo backup power from Area B to Area A
P.S
Area A
Area B
55V 87V
19
SAFECOM’s powering system around the worldReliability since 1994
20
21
Power backup Comparisons
Synergy-2 / DPS V5
Generators Non Standby
Standby + Batteries
Power Type
Low High Low High Cost
Zero Permanent Negligible
Permanent Maintenance
Unlimited Limited by fuel
None 2 to 3 hour(Depends on
batt. condition )
Backup Power
Low cost Very expensive
Low Very Expensive
Redundant/ Diversity
22
Typical optical network powering examples
23
90V-network60V-available
Deep Fiber network .DPS5 Backup design
24
60V-network90V-available
HFC Network 90V- DPS5+ Power Booster backup power90V-network60V-available
25
90V-network60V-available
HFC Network 90V- DPS5 backup power
26
Business case.
Improving customer service and satisfaction. Enabling MSO to add new services that required top high
reliability. Unlimited backup time. Reducing dramatically CAPEX & OPEX. Increasing powering efficacy & save energy.
27
Complete Tree-View Import using CSV file• Also can discover One node at a time from the UI (on –demand discovery )• Network discovery• Export the Tree-View for further Use
1. Discovery can be backed up2. Automated Full Topology DPS/ SYNERGY back up
Auto Discovery of the PS Monitor• Supports any device that has a SCTE-HMS-PS-MIB• Supports auto discovery of thresholds (SCTE-HMS-COMMON-MIB )• Auto Generates Attribute Widgets with properly formatted thresholds• Supports all Adjacent devices like APC, Cordex Controllers etc.• Supports Discrete Thresholds
DOCSIS® & EuroDOCSIS Status Monitoring
28
• Monitors the Attributes – Pre-Configured Poll Interval– Summarization ( Hourly , Daily )– Graphing ( Single or Multiple attributes )– Attribute Refresh ( on demand )
• Monitors the Current Alarm Table– Generates the Events from this table– Auto Correlation ( If the alarm is pre-existing, does not generate a new
Alarm)– Updates the Tree-view with corresponding Severity – If SNMP Traps are enabled, It will auto-correlate the incoming traps with
Current Alarm table
29
Google Maps Integration
30
ON-LINE REPORT
31
Latest Power Protection unit for CATV Networks Enabling phase changer (APC) option for all type of Power Supplies & UPS + build in 140KA Surge suppressor , for protecting P.S & actives devices at the CATV network against surge from electric utility system. Novel technology enables to monitor both the surge suppressor & Phase changer by IP Monitoring.
Housing design for outdoor hanging or shelf-lain mounting inside closed Cabinet.
CATV POWER PROTECTOR Model SC-APC-SPD140K-IPM
32
When using generator IP monitor enable to notify technician when utility power returns for pickup the generator from outage site.
Second AC input port can be use for connecting generator without the needs to disconnect any power cable.
33
Europe 60V & US 90V Standard. Support full 15A rms input /output. Prefect voltage at the remote location in the network. Water-proof Enclosure.(IPX8)�� Opposite connection protected. Input & Output Surge Protection.�� DOCSIS® & EuroDOCSIS Status Monitoring. Online RF transmission during operation.
(INTERNET,VOD,VOIP)
DPSv5 / SYNERGY-2/ Power Booster
Power Innovation
Standard Features
34
Summery SAFECOM SYNERGY-2 & DPSv4 & Power Booster offers CATV operators the
most efficient and reliable complete backup solution for unlimited time at minimum cost.
No additional cost for MSO further to the fact that SYNERGY-2 / DPS v4 unit can be reuse from HFC network to full optical network.
Following the government regulation for full powering backup. SYNERGY-2 ,DPSv4 & Power Booster systems enabling additional backup from
remote powering. No maintenance. Unlimited life time. Two way powering on a single cable (Coax or electrical cable) Full DOCSIS® & EuroDOCSIS Status Monitoring
35
Thank you
Tel +972-544311933 / Fax +972-9-7968033 / Habustan st (PO 132) / Israel 40691/ E-mai l [email protected]