© Landis+GyrAuthor
18.04.23 / 1Product Updates/Overviews and Training – 2004
C.B. Associates and
Landis + Gyr
© Landis+GyrAuthor
18.04.23 / 2
© Landis+GyrAuthor
08.03.2004 / 2
Agenda
8:30 – 9:30 Focus/Altimus/S4e Overview
9:30 – 11:30 1132 Prog & Com Software
11:30 – 12:00 ProPak, ProView, Focus S/W
12:00 – 12:30 Lunch
12:30 – 3:00 MAXsys Meter and Software
3:00 Questions / Adjourn
© Landis+GyrAuthor
18.04.23 / 3
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 4
Landis + GyrResidential Metering
Altimus FamilyAL Kwh Only
AXL Kwh only/UpgradeableAX Demand/Tou
RX ReactiveService Disconnect
© Landis+GyrAuthor
18.04.23 / 5
Landis + GyrResidential Metering
Altimus Communications
Optical PortModem
DCSI
© Landis+GyrAuthor
18.04.23 / 6
Altimus with DCSI
• Altimus Kwh Only, Demand, TOU
• Altimus Disconnect with DCSI
- 200 Amp BLP Switch
- Remote Arming with
Onsite Activation
- Load Side Sensing
- Current Limiting
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 7
Landis+GyrResidential Metering
The FOCUS Family of
Residential Meters
© Landis+GyrAuthor
18.04.23 / 8
Landis+GyrResidential Metering
FOCUS Family Objective
“To provide the utility industry with a reliable, quality, low cost solid state kWh meter platform
that is easily adaptable to various AMR technologies.”
© Landis+GyrAuthor
18.04.23 / 9
Landis+GyrResidential Metering
FOCUS Family Vision
“To be the supplier of choice for solid state residential AMR metering products.”
© Landis+GyrAuthor
18.04.23 / 10
FOCUS kWh Technology
• Digital Multiplication Measurement
• Single Circuit Board Design
• Landis+Gyr ASIC
• Supports NET metering
• Non-volatile Memory
• Designed for 15+ Year Life
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 11
Landis+GyrResidential Metering
FOCUS Available Meter Forms
• 2S, 2SE, 4S and 2K 240V
• 1S 120V
• 3S 120V and 240V
• 12S and 25S 120/208V
© Landis+GyrAuthor
18.04.23 / 12
FOCUS Meter Specifications
• Operating Temperature Range -40°C to +85°C• Load Performance Accuracy Class .2% • Starting Load 50 mA or 12 Watts (2S)• Burden < 1.8 Watts (2S)• Meets ANSI Standards• ANSI protocol
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 13
Landis+GyrResidential Metering
FOCUS kWh Meter Features
• Selectable Metrics• Flexible Display Functionality• Optional KYZ Output• Configuration Port• Factory Programming Available• Polycarbonate and Glass Covers available • Sealed using T-seal and wire seal methods
© Landis+GyrAuthor
18.04.23 / 14
Landis+GyrResidential Metering
FOCUS kWh Meter Displayable Metrics(any or all)
• + kWh• - kWh• Net kWh• Added kWh (Security)• Line Voltage • Diagnostic Flags
© Landis+GyrAuthor
18.04.23 / 15
Landis+GyrResidential Metering
FOCUS kWh Flexible Display Functionality
• Easily Readable 8-digit LCD• Power Consumption Indicator (DRI, DPI)• 4x1, 4x10, 5x1 and 6x1 metric display• Selectable Meter Multiplier up to 240 (1200:5 CT)• Scroll sequence can include Diagnostic Flags and Line Voltage• Display scroll - Programmable from 1 to 15 seconds
© Landis+GyrAuthor
18.04.23 / 16
FOCUS kWh Configuration Port Capabilities
• Designed for meter shop environment• Configuration can be done without removing cover• Set or reconfigure display metrics, multipliers etc.• Reset register to zero (also preset specific value)• KYZ Output selectable (1/12 increment of Kh) +kWh, -kWh or Added kWh
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 17
Landis+GyrResidential Metering
FOCUS Road Map
kWh AMR Dem/TOU/LP
© Landis+GyrAuthor
18.04.23 / 18
Landis+GyrResidential Metering
FOCUS kWh Only Availability• Forms 1S, 2S, 2SE, 3S (120 & 240 volts) and 4S - Available Now
• Forms 12S and 25S (Network) - Available Now
• Form 2K - Available by June ’04• KYZ Output - Available by March ’04 • Forms 2s, 2se and 12s - Available with and without external potential link
© Landis+GyrAuthor
18.04.23 / 19
Landis+GyrResidential Metering
FOCUS Planned AMR Technologies
Focus SL-1 (StatSignal)
KWH Only+2-way RF (900 MHz Mesh Technology)Integrated AMREnhanced feature capabilitiesAvailable by May ‘04
© Landis+GyrAuthor
18.04.23 / 20
Landis+GyrResidential Metering
FOCUS Planned AMR Technologies
Focus TS-1 (Hunt Technologies)
KWH Only1-way PLCModular Design (Plug & Play)Available by July ‘04
© Landis+GyrAuthor
18.04.23 / 21
FOCUS Planned AMR Technologies
FOCUS TS-2 (Hunt Technologies)
kWh Only+2-way PLCIntegrated Design Available by Sept ‘04
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 22
FOCUS Planned AMR Technologies
FOCUS DCSI (TWACS)kWh Only+2-way PLCIntegrated AMREnhanced Feature Set Available June ‘04
Landis+GyrResidential Metering
© Landis+GyrAuthor
18.04.23 / 23
Landis+GyrS4 Family News
© Landis+GyrAuthor
18.04.23 / 24
Landis+Gyr C&I Metering: S4 Features •Build a meter concept
- Software upgrade: AXL to AX to RX- Output relay flexibility - 4 out, 2 in- Up to 128k ram with 15 programmable
channels of load profile and up to 6 Self-Reads
- Modem, RS232, RS485, AMR module
•High sampling rate - 3 MHz for V and I pairs•Simultaneous utilization of modem, LP, KYZ, TOU•Real-time Rate activation•Largest space “under cover” for AMR applications
© Landis+GyrAuthor
18.04.23 / 25
Enhancements To S4 – S4e
Customer’s investment protected -Flash memory
*Allows upgrades and feature enhancements
-128k ram – On board (15 LP channels)-Firmware versions available for ANSI tables or DGCOM protocols
-Transformer Loss Compensation (available in ANSI version)
© Landis+GyrAuthor
18.04.23 / 26
ServiceScantm Displays
NOTE: Continuous Display GyrPyetm Power Quad Indicator
NOTE: Electronic Disk EmulatorNOTE: Continuous Display of Nominal Voltage and Service
© Landis+GyrAuthor
18.04.23 / 27
S4 and S4e New Hybrid Cover
© Landis+GyrAuthor
18.04.23 / 28
New Hybrid Cover Features
Superior Design
Improved reset switch – easier to use
Non-yellowing automotive headlamp grade acrylic window molded into polycarbonate cover.
Window strength superior to competition cover
Existing optical port design
Keylock available
In production now
© Landis+GyrAuthor
18.04.23 / 29
Landis+Gyr - C&I Metering S4 AMR Technologies
•DCSI (“under-the-cover) – Now•PLC
•SIMS (“under-the-cover”) - Now•Skytel pager network
•Envoy (“under-the-cover”) – Now•Skytel pager network
•Innovatech (External) – Now•RS232 output from meter
•Comverge CDMA cellular (External) – Now•RS232 output from meter
•Hunt (External) – Now•Pulse output from meter
© Landis+GyrAuthor
18.04.23 / 30
Communicating S4 Meter Status
CDMA/GPRS (undercover)
• June 04
S4-Pager (ENVOY) – Released to Production (Offers Ultracap/No Btry)
IP module (undercover)
• Development in works• 1- Field BETA test site now
DCSI CMT-S4 Module Released
1-port, 3-port and 480V Versions
Landis+GyrS4 Family News
© Landis+GyrAuthor
18.04.23 / 31
Additional S4 Communication OptionsUnder Development
• StatSignal two-way 900 Mhz RF mesh technology – April 04
• Smart Synch Telephone Modem – Sample Stage Now
• Hunt Technologies TS2 two-way module
Landis+GyrS4 Family News
© Landis+GyrAuthor
18.04.23 / 32
AGENDA
- 1132 Prog and 1132 Com
- ProPak
- ProView
- Focus Config Tool
© Landis+GyrAuthor
18.04.23 / 33
1132Prog & 1132Com
Landis + Gyr Program and Read
Windows based Software
© Landis+GyrAuthor
18.04.23 / 34Training Agenda
•This Presentation
•Load Software
•Demo 1132Prog
•Demo 1132Com
© Landis+GyrAuthor
18.04.23 / 35
Products Supported?
•DGCOM Protocol
-DXS2 Meters
-RDS3 Meters
-AX/RX S4 & AX/RX Altimus Meters
-DXMX Meters
•ANSI Protocol
-AX/RXS4 Meters
© Landis+GyrAuthor
18.04.23 / 36
Products Not Supported
•Optocom Protocol (Early to Mid 80’s)
•CTR Registers
•DD Registers
•DG-100 Recorders
• DC/DCR
•PDR Family (Early 80’s)
© Landis+GyrAuthor
18.04.23 / 37Cables Supported
•Siemens Optical Probe
•PM-500 Series Probes
•GE Smartcoupler
•Ametek Probe being investigated
© Landis+GyrAuthor
18.04.23 / 38Operating Systems
•We are committed to the following:
-Windows ’98 – Second Addition
-Windows NT
-Windows ME
-Windows 2000
-Windows XP
© Landis+GyrAuthor
18.04.23 / 39Database
•MS Office Access 2000
-Can use existing Access 2000
- We provide RT MS Office Access 2000
© Landis+GyrAuthor
18.04.23 / 401132Prog Functional Differences
•1132Prog is built as a project on an MS Access
database
•You can have multiple databases
•Each database can have multiple field packages
•Meter Upgrades are NOT part of
1132Prog/1132Com
•Done with a utility called ProPak
•Communication setup done within 1132Com
•Field packages only for program availability and
menu choices
© Landis+GyrAuthor
18.04.23 / 41More 1132Prog
Functional Differences
Two levels of Users in 1132Prog
•Programmer
•Cannot Edit Users or Security
•Administrator
•Can Edit everything
Sample programs never lost
© Landis+GyrAuthor
18.04.23 / 421132Com Features
•Probe/Protocol independent (you do not need to
specify, but you can set which to try first)
•PC serial port and modem setup within 1132Com
-Does not affect Operating System settings
-Uses ‘normal’ Windows GUI
•Retains more device information
•More extensive On Line information
© Landis+GyrAuthor
18.04.23 / 431132Com Features Cont’d
•Retains Communications Log and Trace Log
•Can see Load Profile via View Data
•More information available during comm sessions
•Task Bar can be customized
•V & A can be displayed & printed as vectoral
diagram
•Much more complete on-line help
•Wizard tool for programming
© Landis+GyrAuthor
18.04.23 / 441132 Installation
There are two down loads: 1132Prog and 1132Com
•1132Prog installation
- Do not have Access at all and
need Access 2000 RT (70MB)
- Have Access ’97 and need
Access 2000 RT (10MB)
© Landis+GyrAuthor
18.04.23 / 451132Com Installation
•Can be loaded independent of 1132Prog
•It is a separate install
•Requires about 15MB (plus ‘room’ for data)
© Landis+GyrAuthor
18.04.23 / 46
1132Prog to 1132Com
•If on same PC, run 1132Com from 1132Prog
•If on a different PC, load 1132Com and then
simply copy needed Access databases (*.mdb) to
1132Com
•Source directory (default)
•C:\Program Files\Siemens\1132Prog\Meter Files
•Default destination directory is the same
© Landis+GyrAuthor
18.04.23 / 47Reporting
•ProView, with a ‘new’ LPFILES, will support
DGCOM files
•MAXtrac, when updated, will support both ANSI
and DGCOM
•MV-90 is able to handle DGCOM now
•Working with MV-90 on the ANSI support
© Landis+GyrAuthor
18.04.23 / 48Migration from DG1100
• Programs built in DG1100 cannot be migrated!
•Too many differences in
the data structures
•Good opportunity to
clean them up
© Landis+GyrAuthor
18.04.23 / 49
Support
•Call your local Salesperson
•Call the Siemens Metering Help Desk (800) 777-
2774
© Landis+GyrAuthor
18.04.23 / 50
Problem Reporting
Call the help desk (800) 777-2774
Be prepared to provide:
• Good problem description
• Operating system
• Version in question
• Meter type & firmware
• Database and data directory on request
© Landis+GyrAuthor
18.04.23 / 51Problem Resolution
Priorities:
• Identified and verified issues (broken)
• ‘New work’ items (including new
firmware releases)
© Landis+GyrAuthor
18.04.23 / 52