download product pdf - hitachi cable america

2
Fiber Optic MPO Trunk Cable Assemblies DataShield™ solutions from Hitachi Cable America are built to offer maximum throughput. Using high-performance materials for long-lasting application life, DataShield™ assemblies are easy to deploy. And, since you customize the solution to your specific needs, you get exactly what you want. Whether you are adding to an existing facility or designing a new one, DataShield™ delivers the performance and value that you want. The smaller size still delivers the same installa- tion & long term tensile strength as the larger, heavier construction. Corning Clearcurve™ bend insensitive glass delivers lower installation optical loss & ex- tended life after installation. Industry standard MPO female (un-pinned) connectors ensure reliable and repeatable re- sults when used with DataShield™ Cassettes with MPO male (steel pinned) connectors. Ruggedized cable leg lengths ensure “no kink” MPO trunk terminations at the cassette junc- tion. Cables available with and without pulling sleeve. All assemblies are 100% light loss tested (850 nm for OM1, OM2, OM3 & OM4 multimode and 1310 nm for OS2 singlemode). Reflection tested at singlemode and multi- mode wavelengths as applicable. Why are DataShield™ MPO trunk assemblies different? DataShield 4U DataShield Fiber Optic Rack-Mount Enclosure DataShield DataShield™ solutions are built with extra-strength materials for long- lasting application life. Applications: Telecommunications LAN, WAN, SAN FTTX Enterprise Industrial Control Systems CATV Broadcast Professional A/V University / School Campus Hitachi Cable America’s DataShield™ rack mount 16 AWG steel fiber optic enclosure supports the most popular cable types. Features: For use in 19” or 23” racks Accommodates in-field connector termina- tion or pre-terminated solutions Top (adjustable) and bottom wire saddles for cord management Hitachi Cable America’s LC to MPO Cassettes are built for plug and play simplicity. These cassettes feature Dual MPO adapters on the back and duplex fiber adapters on the front face. Inside the cassette is an MPO to LC fiber connector fan-out that provides the interconnect from the front to the back of the cassette. Twelve of these cassettes fit into the 4U DataShield™ rack mount enclosure. OM2, OM3, OM4 and OS2 solutions are standard. Other connector and glass types are available upon request. All cassettes have factory terminated ends and are 100% light tested before shipment. Corning’s Clearcurve™ glass is used for long term reliability. Part # Description DM-3-MLCB24 Preloaded cassette, 24 fiber, 50/125 OM2 Dual Male MPO to LC duplex Insertion Loss; .8 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D DM-4-MLCB24 Preloaded cassette, 24 fiber, 50/125 OM3 Dual Male MPO to LC duplex Insertion Loss; .8 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D DM-5-MLCB24 Preloaded cassette, 24 fiber, 50/125 OM4 Dual Male MPO to LC duplex Insertion Loss; .8 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D DM-1-MLCB24 Preloaded cassette, 24 fiber, 9/125 OS2 Dual Male MPO APC to LC duplex Insertion Loss; .7 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D 24 Fiber DataShield LC to MPO—Cassette Part # Description HC000008 Fiber Optic 4U DataShield™ rack-mount enclosure, 12-cassette capable up to 288 fibers, black with hinged , clear door. 17” W x 17” D X 6.98” H; weight: 16.90 lbs.; cold rolled steel 16 AWG to ASTM 1008 Meets ANSI / TIA / EIA 568B / 606A; ROHS & REACH compliant OM3 Dual MPO / LC 24 fiber cassette shown with clear cover to demonstrate internal optical glass routing between MPOs & LCs. * Images are representative only – actual product may differ. NanoCore Loose Tube No Gel Distribution Single-Jacket (Plenum) Interconnect (Plenum)

Upload: others

Post on 11-Feb-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Download Product PDF - Hitachi Cable America

Fiber Optic MPO Trunk Cable AssembliesDataShield™ solutions from Hitachi Cable America are built to offer maximum throughput. Using high-performance materials for long-lasting application life, DataShield™ assemblies are easy to deploy. And, since you customize the solution to your specific needs, you get exactly what you want. Whether you are adding to an existing facility or designing a new one, DataShield™ delivers the performanceand value that you want.

The smaller size still delivers the same installa-tion & long term tensile strength as the larger, heavier construction.

Corning Clearcurve™ bend insensitive glass delivers lower installation optical loss & ex-tended life after installation.

Industry standard MPO female (un-pinned) connectors ensure reliable and repeatable re-sults when used with DataShield™ Cassettes with MPO male (steel pinned) connectors.

Ruggedized cable leg lengths ensure “no kink” MPO trunk terminations at the cassette junc-tion. Cables available with and without pulling sleeve.

All assemblies are 100% light loss tested (850 nm for OM1, OM2, OM3 & OM4 multimode and 1310 nm for OS2 singlemode).

Reflection tested at singlemode and multi-mode wavelengths as applicable.

Why are DataShield™ MPO trunkassemblies different?

DATA SHIELD™

DATA SHIELD™ solutions are built with extra-strength materials for long-lasting

application life.

DataShield™ 4U DataShield™ Fiber OpticRack-Mount Enclosure

DATA SHIELD™

DATA SHIELD™ solutions are built with extra-strength materials for long-lasting

application life.

DataShield™

DataShield™ solutions are built with extra-strength materials for long-lasting application life.

Applications: Telecommunications LAN, WAN, SAN FTTX Enterprise Industrial Control Systems CATV Broadcast Professional A/V University / School Campus

Hitachi Cable America’s DataShield™ rack mount 16 AWG steel fiber optic enclosure supports the most popular cable types.

Features:

For use in 19” or 23” racks Accommodates in-field connector termina- tion or pre-terminated solutions Top (adjustable) and bottom wire saddles for cord management

Hitachi Cable America’s LC to MPO Cassettes are built for plug and play simplicity. These cassettes feature Dual MPO adapters on the back and duplex fiber adapters on the front face. Inside the cassette is an MPO to LC fiber connector fan-out that provides the interconnect from the front to the back of the cassette.Twelve of these cassettes fit into the 4U DataShield™ rack mount enclosure. OM2, OM3, OM4 and OS2 solutions are standard. Other connector and glass types are available upon request.All cassettes have factory terminated ends and are 100% light tested before shipment. Corning’s Clearcurve™ glass is used for long term reliability.

Part # Description

DM-3-MLCB24 Preloaded cassette, 24 fiber, 50/125 OM2 Dual Male MPO to LC duplexInsertion Loss; .8 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D

DM-4-MLCB24 Preloaded cassette, 24 fiber, 50/125 OM3 Dual Male MPO to LC duplexInsertion Loss; .8 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D

DM-5-MLCB24 Preloaded cassette, 24 fiber, 50/125 OM4 Dual Male MPO to LC duplexInsertion Loss; .8 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D

DM-1-MLCB24 Preloaded cassette, 24 fiber, 9/125 OS2 Dual Male MPO APC to LC duplexInsertion Loss; .7 dB Max @ 850 nm max. 5.1” W x 1.15” H x 4.6” D

24 Fiber DataShield™

LC to MPO—Cassette

Part # Description

HC000008 Fiber Optic 4U DataShield™ rack-mount enclosure, 12-cassette capable up to 288 fibers, black with hinged , clear door.

17” W x 17” D X 6.98” H; weight: 16.90 lbs.; cold rolled steel 16 AWG to ASTM 1008

Meets ANSI / TIA / EIA 568B / 606A; ROHS & REACH compliant

OM3 Dual MPO / LC 24 fiber cassette shown with clear cover to demonstrate internal optical glass routing between MPOs & LCs.

* Images are representative only – actual product may differ.

NanoCore™ Loose TubeNo Gel Distribution Single-Jacket (Plenum)

Interconnect (Plenum)

Page 2: Download Product PDF - Hitachi Cable America

Hitachi Cable America’s DataShield™ cables are designed and manufactured at our modern 300,000 square-

foot facility in Manchester, New Hampshire, USA. For over 27 years, Hitachi Cable America has focused on

building high-quality cables that exceed their performance requirements.

In addition to DataShield™ fiber optic assemblies and hardware, the Manchester facility also manufactures

Category 5e, 6 and 6A copper communication cables, round and flat electronics cables and a vast selection

of singlemode and multimode fiber optic cables.

For more information about Hitachi Cable America products, please contact the Manchester facility.

900 Holt Avenue, Manchester, New Hampshire 03109 USATel: +1-603-669-4347 Fax +1-603-669-9621

www.hca.hitachi-cable.com

DELIVERING TODAY’S INFORMATION AT TOMORROW’S SPEED

07/2013

WORLDWIDE COVERAGE

Fiber Optic Assemblies & Hardware

DATA SHIELD™

DATA SHIELD™ solutions are built with extra-strength materials for long-lasting

application life.

DataShield™

The products, their specifications, services and other information in this document are subject to change without notice. © 2013 Hitachi Cable America Inc., Ltd All rights reserved.

Standard Stock Lengths (feet): 3, 7, 10, 16, 20, 26, 33

DATA SHIELD™

DATA SHIELD™ solutions are built with extra-strength materials for long-lasting

application life.

DataShield™ Optical Fiber AssembliesUse the part number builders below to design trunk assemblies and patch cords that meet your specific needs.

Trunk Assembly Part Number Builder

Assembly type

# of Fibers

Glass Type Cable Type Cable Rating Lead Distribution

Breakout Length (Feet)

Wiring Method Connector End A Connector End B Pulling Eye Assembly

Length (ft.)

15800 12 1 1 S B 002 A MM FC 2 0105

12 OM1 = 1 Nanocore SJ ILA OFCP = 2 N/A = N Equal Lengths

= E ex. 002 ft. Method A = A Blunt End = BE Blunt End Both Ends = 1 ex. 105 ft.

24 OM2 = 2 Nanocore SJ OFNP = 1 Plenum = P Staggered

Both Ends = D Method B = B FC = FC FC Side A = A

36 OM3 = 3 Riser = R Staggered End A = A LC = LC LC Side B = B

48 OM4 = 4 Riser/LSZH = S

Staggered End B = B LC Uniboot = LU LC Uniboot None = 2

72 OS2 = 5 MPO Female = MF MPO Female

96 MPO Male = MM MPO Male

144

Sample Part Number: 158001211SB002AMMFC20105

Standard Trunk ConfigurationFemale MTP connectors.Method A wiring. Refer to FAQ section of HCA website for Method A and Method B wiring explanation.2 Foot breakout lengths.One pulling eye for any length 100 feet or longer.Packaging - Coiled in a bag up to 100 feet. Spooled on a 3 flange reel if longer than 100 feet.Labeling - HCA p/n and date code on a wrap label on both ends of the assembly. HCA p/n on bag & reel.

Non-Standard InformationOM1, OM2 & OM4 are non-stock items and subject to MOQs and lead-times.(12, 24 fiber - 2KM MOQ, 36,48 fiber - 1KM MOQ, 72-144 fiber - .5KM MOQ).

Standard Cable InformationStocked cable - OS2 & OM3 - 12, 24, 48, 72, 96, 144.OM4 - 96, 144.24 - 144 fiber will be 2.0mm plenum Single Jacket Nanocore.12 fiber will be 3.0mm plenum Single Jacket Nanocore.Jacket colors - OS2 - Yellow.OM1, OM2 - Orange.OM3 - Aqua.OM4 - Erika Violet.

Standard Connector & Termination InformationMPO - MPOMPO - LCLC - LCFurcation will match cable jacket color.Polish - UPC (Ultra Physical Contact, single connector LC), PC (Physical Contact, MPO multimode connector), APC (Angled Physical Contact, OS2 MPO connector).

Patch Cord Part Number Builder

Sample PN: 157000111RSSTSC0100F

Assemby Type (Patch) Fiber Count Fiber Type Cable OD Cable Type Cable Rating Connector Side A Connector Side B Length Unit of Mea-

sure (Feet)

15700 01 1 1 R S ST SC 0100 F

Simplex = 01 OM1 = 1 2.0 = 1 Round = R Plenum = P LC = LC LC = LC ex. 100 ft. F = Feet

Duplex = 02 OM2 = 2 2.5 = 2 Zipcord = Z Riser = R SC = SC SC = SC

OM3 = 3 2.9 = 3 Riser/LSZH = S ST = ST ST = ST

OM4 = 4

OS2 = 5

The part number configurators will occasionally be updated. To use the latest electronic version, visit the HCA website.