Reading and Configuration tool
alphaSETInstruction manualVersion:
2.05.00
Date:
11/10/06
Document name:
alphaset_user_manual_GBR.doc
Page 2alphaSET, user manual, Version 2.05.00
Page 2 of 111
1 Overview
COPYRIGHT
Copyright 2006 ELSTER Messtechnik GmbH. All rights reserved.
All rights, also those the translation, the reproduction and the duplication of the document, or
parts from it, reserved. No part of the document may be multiplicated without written
permission of the ELSTER Messtechnik GmbH in any form (electronically, mechanically,
photographically or another procedure) or be spread.
Printed in Germany
Attention
ELSTER Messtechnik GmbH reserves itself the right to carry out changes in all products
described in this manual to improve reliability, function or design. Specifications and
information, which are described here, can change without notification. Not all occurrences,with all possible details and variations of the devices, which can appear during the installation,
the use and maintenance, are covered by this manual
ELSTER will not be responsible for errors in this document or for consequential damages in
the reference to mechanism, achievement or use of this material.
ELSTER does not take any responsibility and adhesion for the installation, use, achievement,
care and support of products third.
For further information, see the following references:
ELSTER Electricity meter customer support:
+0049 (0) 6206 933 339
ELSTER Electricity meter customer support e-mail:
ELSTER company web site:http://www.elster.com
ELSTER Electricity meter web site:
http://www.elstermetering.com
Page 3alphaSET, user manual, Version 2.05.00
Page 3 of 111
1 Overview
https://mail-attachment.googleusercontent.com/attachment/?view=att&th=12d37947f52f27b9&attid=0.1&disp=attd&zwmailto:[email protected]://www.elster.com/http://www.elstermetering.com/https://mail-attachment.googleusercontent.com/attachment/?view=att&th=12d37947f52f27b9&attid=0.1&disp=attd&zwmailto:[email protected]://www.elster.com/http://www.elstermetering.com/ -
7/30/2019 Download ELSTER Energy Meter-Kar Key
2/52
Table of contents1
Overview...............................................................................................................................6
1.1 System overview...............................................................................................................6
1.2 Document history ..............................................................................................................6
2Referenced documents .......................................................................................................7
3
Introduction / brief description...........................................................................................8
3.1 What is the alphaSET tool ?..............................................................................................8
3.2 System requirements ........................................................................................................8
3.3 Installation / Update ofalphaSET......................................................................................9
3.4 Start of the software and user-profile..............................................................................13
3.4.1 First start after installation........................................................................................13
3.4.2 User-profile ..............................................................................................................15
3.4.3 Use of the software.................................................................................................17
3.5 Indication of the software version....................................................................................20
4
User settings ......................................................................................................................21
4.1 Communication ...............................................................................................................21
4.1.1 Remarks to the user-profile Railway......................................................................23
4.2 Modem ............................................................................................................................24
4.2.1 Initialization strings...................................................................................................25
4.3 Files.................................................................................................................................25
4.4 Read register...................................................................................................................26
5
Load profile ........................................................................................................................27
5.1 General Settings .............................................................................................................28
5.2 User language.................................................................................................................29
5.3 IEC 1107-Address...........................................................................................................30
5.4 Change utility password..................................................................................................30
6
Read meter data.................................................................................................................31
6.1 Read register list .............................................................................................................31
6.2 Read service list..............................................................................................................32
6.3 Read settings ..................................................................................................................33
6.4 Read load profile.............................................................................................................35
6.4.1 Graphical display of load profile data.......................................................................37
6.5 Read power quality monitoring........................................................................................40
6.5.1 Graphical display of power quality data ...................................................................41
6.6 Read log file ....................................................................................................................42
6.7 Read log file 2 .................................................................................................................43
6.8 Read meter error status ..................................................................................................44
6.9 Read communication protocol.........................................................................................45
7
Configuration of the meter................................................................................................46
7.1 Open of a parameter file .................................................................................................46
7.2 Save a parameter set......................................................................................................46
7.3 Configuration of a meter by using a configuration file.....................................................47
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
3/52
7.3.1 Switch point clock ....................................................................................................47
7.3.2 Settings (without PW + ID).......................................................................................47
7.3.3 Settings and parameterisations (without PW + ID) ..................................................48
7.4 Change of parameters ....................................................................................................48
8
Change of meter configuration.........................................................................................50
8.1 Identifications ..................................................................................................................51
8.2 Tariff source ....................................................................................................................53
Page 4alphaSET, user manual, Version 2.05.00
Page 4 of 111
1 Overview
8.3 Switch point clock............................................................................................................54
8.3.1 Day type...................................................................................................................54
8.3.2 Season change........................................................................................................55
8.3.3 Tariff switch table.....................................................................................................56
8.3.4 Holiday-list ...............................................................................................................57
8.3.5 Daylight saving time.................................................................................................58
8.4 Switch point clock (Update).............................................................................................59
8.4.1 Day type...................................................................................................................59
8.5 Times ..............................................................................................................................60
8.5.1 Source of Times.......................................................................................................60
8.5.2 Display Timeouts .....................................................................................................61
8.5.3 Communication Timeouts ........................................................................................62
8.6 Demand reset..................................................................................................................63
8.7 Overload threshold..........................................................................................................64
8.8 Baud rate.........................................................................................................................65
8.9 Synchronization...............................................................................................................66
8.10 Backup time of the real time clock ................................................................................68
8.11 Inverting Inputs/Outputs................................................................................................68
8.12 Power quality.................................................................................................................69
8.12.1 Release of power quality functionality ....................................................................69
8.12.2 Load profile of power quality data...........................................................................70
8.12.3 Power Quality Monitoring .......................................................................................71
8.13 Copper-/Iron-losses.......................................................................................................72
8.14 Display ..........................................................................................................................73
8.14.1 Service list..............................................................................................................73
8.14.2 Display parameter ..................................................................................................75
8.15 Pulse constants.............................................................................................................78
8.16 Pulse inputs...................................................................................................................79
8.17 Load profile / logfile - parameter ...................................................................................80
8.17.1 Load profile parameter ........................................................................................80
8.17.2 Log file parameters...............................................................................................81
8.18 Energy / Demand measuring ........................................................................................82
8.19 Show settings................................................................................................................82
8.20 Meter Access Rights .....................................................................................................83
8.21 Passwords.....................................................................................................................85
9
Formatted Meter Commands ............................................................................................86
9.1 Set meter date/time using the W2 command..................................................................87
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
4/52
9.2 Read and Set time/date using the VDEW command ......................................................88
9.3 Setting of pulse constants...............................................................................................89
9.4 Setting of outputs ............................................................................................................90
9.5 Activation of DCF 77 signal decoding .............................................................................91
9.6 Reset maximum demand ................................................................................................92
9.7 Reset meter error status .................................................................................................93
9.8 Reset power quality profile..............................................................................................949.9 Reset power-loss counter ...............................................................................................95
9.10 Reset terminal cover open counter ...............................................................................96
9.11 Reset register................................................................................................................96
9.12 Set register values (pulse inputs)..................................................................................97
9.13 Reset load profile + logbook..........................................................................................98
10
Integrated Ripple receiver (LCR) ....................................................................................99
11
Test..................................................................................................................................100
11.1 Read meter error.........................................................................................................100
Page 5alphaSET, user manual, Version 2.05.00Page 5 of 111
1 Overview
11.2 Power-Quality..............................................................................................................101
11.3 Test mode ...................................................................................................................103
12
Modem ............................................................................................................................105
12.1 Phone book.................................................................................................................105
12.1.1 Creating a new phone number .............................................................................106
12.1.2 Changing a phone book entry ..............................................................................106
12.1.3 Creating a new telephone book or save an existing one......................................106
12.2 Hang up.......................................................................................................................10612.3 Dial-up doesnt work ! What to do? .............................................................................107
13
Extras..............................................................................................................................108
13.1 Restrict menu system..................................................................................................108
14
Image index ....................................................................................................................110
Page 6alphaSET, user manual, Version 2.05.00
Page 6 of 111
1 Overview
1 Overview1.1 System overviewThis document describes the operation, the functional way and the installation as well as the
technical data of the software tool alphaSET version 3. This tool was refined on the basis from
alphaSET version 2 and is compatible to former versions.
Therefore the following products can be served with this tool:
AEM500
ARM500
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
5/52
AEM550
A220
A1350
A1500
A2500
1.2 Document historyVersion:
2.05.00
Date:
11/10/06
Document name:
alphaset_3_instruction_manual_GBR.
Product Manager:
ELSTER / RIM DEEM Dr. Gerhard Eisenbei
Version Valid up to
alphaSET
version
Valid up toFW-Version
Changes
Date
Author
2.01.00 3.03-xx
4.10
-Initial Version
30/10/02 Thomasberger
2.02.00 3.04-xx
4.20
- Adaptations to FW
4.2020/08/03 Dr. Eisenbei
2.03.00 3.06-xx
4.20 and 5.00
- Adaptations to FW
5.00
24/02/04 A. Aching
2.04.00 3.09-xx
4.30 and 5.10
- Adaptations to FW
4.30 and 5.10
12/05/05 Dr. Eisenbei
2.05.00 3.12-xx4.40, 5.30, 7.00 - Adaption to FW
4.40, 5.20, 5.30, 7.00
11/10/06 Thomasberger
Page 7alphaSET, user manual, Version 2.05.00
Page 7 of 111
2 Referenced documents
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
6/52
2 Referenced documentsTitle
Version
Date
AEM_PR_D_1.pdf
1KGL 921500 V004D 11/05/2001
A1500_PR_E.pdf
R 1.14
06/16/2006
A1350_PR_E.pdf
R 1.17
07/16/2006
A220_PR_E.pdf
R 1.06
06/28/2006
Zhlerstandsbertragung, Tarif- und Last-
steuerung;
Datenbertragung fr festen und mobilen AnschluDIN EN 62056-21
01.03
Elektronische Elektrizittszhler
VDEW-Lastenheft
V2.0
12.97
Page 8alphaSET, user manual, Version 2.05.00
Page 8 of 111
3 Introduction / brief description
3 Introduction / brief descriptionThe following section should help to clear basic questions to the alphaSET tool:
What is the alphaSET tool ?
What are the system requirements for the use of this software ?
How do I install this software ?
What must I do if I would like to update this software ?
How do I start the software ?
What will I see, if I start the software ?
How do I find out, which user profile may execute which action?
How do I find out, which software version I use ?
How do I set a password for the communication with the meter?
Additional information:
For additional information please refer to the product descriptions of the alpha meters (2
Referenced documents).
3.1 What is the alphaSET tool ?The alphaSET tool is a Windows based software to read the data of the alpha meters
AEM 500 / ARM 500 / AEM 550 / A1350 / A1500 / A2500 and A220 (register, load profile, log
book, etc.). Different parameters like setting and parametrization parameters can be
changed according to user's profile. Setting parameter is those attitudes, which can be
changed without breaking the certification seal. To get an access to the parameterisation
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
7/52
parameters of the meter, a parameterisation-switch must be pressed which is via the
calibration mark.
The program is a 32 bit application, being based on a 32 bit environment that runs via
Windows NT 4. X, as well as via Windows XP and Windows 2000.
3.2 System requirementsSubsequet are the requirements for the use of the alphaSET software listed:
IBM PC or compatible PC with 800 MHz Pentium or higher with the following equipment
:-
>=16 MB RAM-
CD ROM disk drive-
at least one free, serial interface (COM1 to COM16)-
>=50 free hard disk memory
Hardware components for communication-
IEC 61107-compatible optical probe for the optical interface-CL0 Converter and RS232 cable for the electric interface (CL0-Interface)-
RS232 cable for the RS232 interface (optional)
Windows 2000 / NT / XP
Monitor with a resolution of at least 600x800 pixel
Page 9alphaSET, user manual, Version 2.05.00
Page 9 of 111
3 Introduction / brief description
3.3 Installation / Update ofalphaSET
You require administrator rights on your PC for the installation of this software-tool.Further it is urgently recommended that you close all windows programs, before starting the
setup. Insert the CD-Rom with the procut information and tools from ELSTER to your CD-
ROM-drive. Automatically the following menu is displayed. Please select your language and
then press the button alpha meter.Image 3-3-1: Installation choose alpha meter
Select in the section AlphaSET the button Installation.Image 3-3-2: Installation choose installation
Page 10alphaSET, user manual, Version 2.05.00
Page 10 of 111
3 Introduction / brief description
Within the next menu you have to choose the language of your setup.
Image 3-3-3: Installation choose language
AlphaSET is preparing the setup and you have to choose next here.Image 3-3-4: Installation information1
Page 11alphaSET, user manual, Version 2.05.00
Page 11 of 111
3 Introduction / brief description
Choose the button next.Image 3-3-5: Installation information2
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
8/52
Select your destination path of alphaSET and press the button Next.Image 3-3-6: Installation select destination
If you update the program, no deinstallation of the old version is necessary. You can simply
install the new version in the same directory.
Page 12alphaSET, user manual, Version 2.05.00
Page 12 of 1113 Introduction / brief descriptionImage 3-3-7: Installation - phone book
You should only secure your phone book, if you have one in a former version.
Further information in chapter 12.1.3 Creating a new telephone book or save an existing one".
SETUP checks now whether sufficient memory is available.
Subsequently a communication window appears in which the installation progress is indicated.Image 3-3-8: Installation - Progress
After completion a window appears with the information that SETUP generates program
symbols. After successful installation a message from SETUP appears.Image 3-3-9: SETUP successfull
Page 13alphaSET, user manual, Version 2.05.00
Page 13 of 111
3 Introduction / brief description
Note:
To secure all functions of the program alphaSET needs at least one installed Windows system
printer, even if no printer is connected.
According to your windows version, you have now a program group, or a start symbol of
alphaSET
3.4 Start of the software and user-profileTo start the alphaSET tool software:
Chose in the Windows Start Menu > Programs > alphaSET > alphaSET
Or click on the Icon on your desktop
To close the software choose File -> Quit3.4.1 First start after installation
With the first start after installation of the alphaset sofware the following window will be
displayed:Image 3-3-10: Start - language
Here please select the language to operate the tool.
With the following menu it is possible to take over all the settings from prior versions of your
computer.
Page 14alphaSET, user manual, Version 2.05.00
Page 14 of 111
3 Introduction / brief descriptionImage 3-3-11: Start old settings
Page 15alphaSET, user manual, Version 2.05.00
Page 15 of 111
3 Introduction / brief description
3.4.2 User-profile
AlphaSET starts with the menu of the profiles.Image 3-4-1: Input user-profile
Each of this profiles has different privileges, that means possibilities of access on the menu
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
9/52
system ofalphaSET. The user profiles are filed in the path " \ IniPfad ". If only one profile is in
this path, this is started automatically, without showing the menu illustrated above. If no profile
is in this path, the invisible profile "consumer" starts automatically, which has lowest privileges.
The user profile serves the storage of all individual settings. If several persons work with a
computer, each user can save his own settings, in order to fall back on them, if he uses again
alphaSET. For information to the storage of an user's profile see chapter 4.1 "Communication".
3.4.2.1 User-Profile "Railway:The user profile "Railway" is planned for applications of the train meter ARM500 and A1500.
The user has to select in the menu extras -> options -> communication the point railway
meter (only difference: 4800 start baud rate).
Page 16alphaSET, user manual, Version 2.05.00
Page 16 of 111
3 Introduction / brief description
3.4.2.2 Overview of user profile functionality
User Profile
alphaSET Software functions
Meter reader
Railway
Installation
Certificatio
n
Utility
MO
DE
M
Power Qual
ity
Read Meter
Read register
X X X X X X X
Read load profile
X X X X X X X
Read logfile
X X X X X X X
Read meter configuration
X X X X X X X
Read meter error
X X X X X X X
Read service list
X X X X X X XRead power quality monitoring
X X X X X X X
Change of parameters
Change utility password
X
X X X
File / read parameter
X X X X X
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
10/52
File with parameter -> meter
X X X X X
Identifications
X
X X X
Tariff source
X X X X XSwitch point clock
X X X X X
Times
X
X X X
Demand reset
X
X X X
Overload threshold
X
X X X
Baud rate
XX X X
Synchronization
X
X X X
Power Quality
X
X X X X
Pulse inputs
X
X X X
Backup time of real time clock
X
X X X
Service List
X
X X X X
Display parameter
X
X X X
Pulse constants
X
X
X
Load-profile / logbook parameter
XX
X
Measuring energy / demand
X
X X X
Read/ Set pulse constants
X
X X X
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
11/52
Meter commands
Set meter date/time
X X X X X X
Read/set date/time
X X X X X X
Read out DCF clock
X X X X X XReset demand maxima
X X X X X X
Reset meter error state
X X X X X X
Reset power-loss counter
X
X
X X
Reset register
X
X
X X
Reset load-profile and logbookX
X
X X
General
Switch to ripple receiver mode
X X X X X X
Test mode
X
X
X X
Communications protocols
XX
X XImage 3-4-2: User profile
Page 17alphaSET, user manual, Version 2.05.00
Page 17 of 111
3 Introduction / brief description
3.4.3 Use of the software
After the selection of the user profile the alphaSET opening screen appears.Image 3-4-3: Opening screen
The program alphaSET is a Windows - based application, which reflects the structure and the
construction of Windows programs.
The window of the main menu consists of The title bar
The menu bar
And the icon bar
In the submenus are further windows (document windows and dialogue windows) indicated,
which show the name of the submenu in the title bar. The menu bar indicates the available
menus, in which the individual actions and switching functions are specified as clear text. This
bar contains several entries, which are described in the following chapters. The icon bar
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
12/52
contains icons for the most used functions.
Title bar
Menu bar
Icon bar
Page 18alphaSET, user manual, Version 2.05.00
Page 18 of 111
3 Introduction / brief description
3.4.3.1 Icon catalogue
The following list explains the available icons of the icon bar.
Read file
Save
Print
Read register
Read service list
Read load profile
Read logfile
Read meter configurationWrite Setting and parametrization
parameter to the meter
Set meter date/time
Demand reset
Page 19alphaSET, user manual, Version 2.05.00
Page 19 of 111
3 Introduction / brief description
Reset meter error state
Reset register
Reset load profile and logbookSwitch to ripple receiver
Read meter error
Activate test mode
Open communication protocol
...about alphaSet
Page 20alphaSET, user manual, Version 2.05.00
Page 20 of 111
3 Introduction / brief description
3.5 Indication of the software version
To get information about the applied software version, select via Help the menu point "aboutalphaSET ... " or click on the following icon:
This command opens a window with the data about the program alphaSET and its version.Image 3-5-1: Information screen
Page 21alphaSET, user manual, Version 2.05.00
Page 21 of 111
4 User settings
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
13/52
4 User settingsIn this chapter the options for the user settings are described. You find these settings via the
menu point Extras.
4.1 Communication
Select via Extras the menu point Options, there the register card Communication.Image 4-1-1: Settings register card communication
COM-Port
With the function "Com-Port" the interfaces Com 1 to Com 16 of the PC can be selected. By
the start ofalphaSET the program checks automatically the COM-Ports of the computer.
It is the decision of the PC user himself whether the selected COM-Port is still free for the use
by alphaSET.
Initial Baud rate
The initial baud rate of the communication between alphaSet and the connected meter can be
adjusted by pull-down-menu. For more information to the baud rate shift see DIN EN 62056-
21.
Utility password
A password for the meter communication can be assigned to the user profile that means an
interrogation of the utility password is not executed any more (useful if the same EVU
password for different meters is used).
Read with 300 Baud only
This option enables the constant reading of the meter with 300 baud. The automatic baud rate
shift is disabled.
Page 22alphaSET, user manual, Version 2.05.00
Page 22 of 111
4 User settings
Suppression of optical reflexion
With this option a lack of the suppression of optical reflexion of the probe according to hard-
ware can be compensated by software.Attention: The probes from P+E delivered by ELSTER do not need this option,
because the suppression of optical reflexion is already realized in the hardware.
Create communication log file
By selection of this option a communication protocol is created automatically, which is also
written directly in a text file.
Waiting time between baud rate switch [ms]
In this box the waiting time con be assigned in milliseconds between the baud rate switching.
Data format
With this choice the physical transmission of the data between the meter and alphaSET can
be defined. Default is 7,E,1. The format 8, N, 1 is only required for special meters.
Note: If the data of the counter are read by the AMR system modem, only the settings
of this modem is relevant and not the settings of the meter. OK
The actual settings are taken over by clicking on this button. They are automatically written in
the user-profile and are available on the next start ofalphaSET.
Copy profile
With the help of this button different settings can be saved in a new user-profile or releases
can be transmitted out of other user profiles.
Cancel
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
14/52
Clicking on this button ignores all changes and you get back to the main program.
Page 23alphaSET, user manual, Version 2.05.00
Page 23 of 111
4 User settings
4.1.1 Remarks to the user-profile Railway
If the user is logged in the user-profile Railway, the following menu appears, in which one
can select additive the option railway meter.
With the selection of this option, the initial baud rate for communication with the meter is set
automatically to 4800 Baud. The train numbers which are stored in the meter are indicated in
the load profile.Image 4-1-2: Settings at user profile "Railway
Page 24alphaSET, user manual, Version 2.05.00
Page 24 of 111
4 User settings
4.2 Modem
Select via Extras the menu point Options, there the register card Modem.Image 4-2-1: Settings register card Modem
Modem
Here the user can set parameters on all modem functions ofalphaSET. These are
necessary for the communication over a meter modem.
Modem settings (Modem connected to the PC)
Keep connection: the time can be registered, how long a connection should be
maintained after the last communication from alphaSET between PC and connected
modem. At the end of this timeout the connection is interrupted and the modem hangs
up.
Interface baud rate: In this drop down menu the baud rate between PC and (control
point) modem can be adjusted. If its possible, select the highest one, which issupported by both.
Initialization: Here is the necessary initialization string registered, which is required for
the communication between PC and PC-Modem (see chapter 0
).
Get line: If necessary, take here the settings to get a local loop (e.g. 0). Should a not
numeric entry stand here, activate additionally the check box also not numeric.
Telephone number: Here can the phone number be registered. If a telephone book is
created, this entry automatically takes place after choice of the appropriate telephone
book entry.
Also not numeric: With this, it is possible to enter also not numeric chars (letters) as
phone number.Page 25
alphaSET, user manual, Version 2.05.00
Page 25 of 111
4 User settings
4.2.1 Initialization strings
Here are strings for the initialization of the modem connected to the PC:
ATZ^MATD
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
15/52
SAGEM mobilephone
AT&FE0X3DT
e.g. for ELSA modem and almost all other modems
If you cant get a connection to your modem with this strings, it is recommended to use the
users manual of your PC-Modem.
4.3 FilesSelect via Extras the menu point Options, there the register card Files.
In this menu the paths on the drives can be defined in which the different files should be
stored. A click to the button enables the changing of the entries.
In the pull down menu Proposal for file name(s) are several suggestions done for an
automatic generation of the file name.Image 4-3-1: Settings register card files
Page 26alphaSET, user manual, Version 2.05.00
Page 26 of 111
4 User settings
4.4 Read register
Select via Extras the menu point Options, there the register card Register.Image 4-4-1: Settings register card
In this window the user can select whether the register data should be shown with or without
clear text (designations according to identification number system OBIS).
The reading of the serial number can be deactivated here, too.
Note: In addition to the deactivation of the reading of the serial number it must be guaranteed
that not meter serial number is selected as Proposal for file name(s) (see 4.3 Files).
Release readout of eHz
If the new eHz (electronic residential 3-phase meter) should be readout this checkbox has to
be selected.
Page 27alphaSET, user manual, Version 2.05.00
Page 27 of 1115 Load profile
5 Load profileSelect via Extras the menu point Options, there the register card Load profile.Image 5-0-1: Settings register card load profile
Read load profile options
Dont read load profile / log book header: If the user reads load profile or log book,
the header is always read first by default, to find out start, end and channel number of
the profile. In the case of a reading without header, the selected period is questioned
directly without reviewing previously, which one is available. In this process, all
available load profiles in the meter are read.
Show load profile including calculated times: This function should be selectednormally. With this, all values in the load profile in alphaSET get time stamps. These
are calculated of the alphaSET automatically based on the meter basic data and are
not delivered by the meter itself (see VDEW-Lastenheft).
Daily readout of load-profile: With this function the readout of load-profile over a
longer period is devided into single days. In this way it is guaranteed, that only the
defective days must be repeated at an occurring communication mistake. (This
function is important in conjunction with transparent meter modems without securing of
data, that do not support the R6 command (in accordance with VDEW-Lastenheft).
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
16/52
Read load-profile/event-log file without password: With this option it can be defined
whether the load profile reading takes place with or without password interrogation.
Page 28alphaSET, user manual, Version 2.05.00
Page 28 of 111
5 Load profile
5.1 General SettingsSelect via Extras the menu point Options, there the register card General.Image 5-1-1: Settings register card general
alphaSET
Edit passwords hidden: With activation the input of the password is not indicated any
more in the clear text, only with ******** .
Reset programming mode after parameterisation: After the change of parameters
in a meter, the alphaSET puts the parameter mode of the counter automatically back.
For more information about the parameter mode see chapter 8 Change of meter
configuration.
Check daylight saving set to EU standard: During the download of the tariff table to
the meter an automatic check of the correct used EU daylight saving time will beexecuted and an error message is displayed if there's inconsistency.
Page 29alphaSET, user manual, Version 2.05.00
Page 29 of 111
5 Load profile
5.2 User languageSelect via Extras the menu point Options, there the register card Language.Image 5-2-1: Settings register card language
Note:
In order to activate all language changes, you should quit alphaSET and restart it after a
language change.
Page 30alphaSET, user manual, Version 2.05.00
Page 30 of 111
5 Load profile
5.3 IEC 1107-AddressSelect via Extras the menu point IEC1107 address .Image 5-3-1: IEC 1107-Address
An IEC1107-address can be registered here, which is send at every communication to the
meter. The meter answers in this case only if the IEC1107-Address sent by alphaSET agrees
with its configured address. The meter IEC address is used if more than one meter is
connected to a modem by using the CL0 or RS485 interface.
5.4 Change utility passwordSelect via Extras the menu point Change utility passwordImage 5-4-1: Utility password for communication
The communication-password (from alphaSET to the meter) can be preset in this menu. That
has no effect to the utility password in the meter.
8 numeric chars are expected.
Page 31alphaSET, user manual, Version 2.05.00
Page 31 of 111
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
17/52
6 Read meter data
6 Read meter dataYou should first check the communication. The command read register is the simplest way to
do it. If this doesnt work, please check the settings ofalphaSET, see chapter 4 User
settings.
6.1 Read register listSelect via Meter the menu point Read register or the following icon:Image 6-1-1 Read register
By using this command the billing data list (register list or Std-dAtA on LCD) of a meter is read
out.
A window appears in which the reading data are visualized. If you have chosen the option
read register with serial number (see chapter 4.4 Read register), the serial number will be
indicated in the title bar.
The identification number is indicated in the first column, the measured value in the second
column and in the third column is an interpretation of the identification number in clear text to
be seen, if the identification number corresponds to the OBIS identification system.
Page 32alphaSET, user manual, Version 2.05.00
Page 32 of 111
6 Read meter data
6.2 Read service listSelect via Meter the menu point Read service list or the following icon:Image 6-2-1: Read service list
By using this command the settable service list (AbL-dAtA on LCD) of a meter is read out.
A window appears in which the reading data are visualized.
The identification number is indicated in the first column, the measured value in the second
column and in the third column is an interpretation of the identification number in clear text to
be seen, if the identification number corresponds to the OBIS identification system.
For further information see chapter 8.14.1
Page 33alphaSET, user manual, Version 2.05.00
Page 33 of 111
6 Read meter data
6.3 Read settingsSelect via Meter the menu point Read settings or the following icon:Image 6-3-1: Read meter configuration
This command enables the reading and displaying of the configuration of the meter. The input
of a utility password is demanded for this operation.
The following meter configurations are displayed:
Type key
Meter-Identification Pulse constants
Demand measuring
Load profile / log file
Real time clock
Tariff source
Demand reset source
Outputs
Baud rate
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
18/52
Page 34alphaSET, user manual, Version 2.05.00
Page 34 of 111
6 Read meter data
Display control
Display list
Switch point clockBy clicking on close you get back to the main menu.
The menu point modify appears in the menu bar after reading meter configuration.
Note: You have the possibility to store the parameter set as text file, so that you can work with
this parameter set in other programs (e.g. text progressing programs)
The following check box serves for this:
In this case, the name (and path) for the text file is asked after inquiry of the file name for the
parameter set. The default pathname is registered in Extras/Options/Files in the field read
meter configuration. The content of the indicated window will be stored.
Page 35alphaSET, user manual, Version 2.05.00
Page 35 of 1116 Read meter data
6.4
Read load profile
Select via Meter the menu point Read load profile, or the following icon:Image 6-4-1: Read load profile
The load profile of the meter can be read with this command. The configuration of the load
profile is read and displayed after confirming.
Certain settings for the specific reading of the load profile can be taken here:
Selection of the measuring channels (as far as they exist in the meter).
Limitation of the reading period. This period can be defined in the from or to input
fields. By deactivating the checkboxes at start and end, the appropriate time stamps
are indicated. These stamps can be edited by double clicking on them. Should acertain window be selected repeatedly, this can be stored and again be activated by
the button "stored values". Frequently used specifications like last month, last week,
yesterday or today can be selected directly.
Partial readout (possibly from FW 3.02), that means use of the R6-command. For more
information see VDEW-Lastenheft.
Depiction of primary values in accordance of the transformer ratio for Voltage and
Current. The transformer ratio is 1:1 if no primary values are activated.
Note: The indicated meter data are then secondary data.
Page 36alphaSET, user manual, Version 2.05.00
Page 36 of 111
6 Read meter dataAfter input of the reading period, the load profile of the meter is read by clicking on the button
read load profile. If all data is read a new button Show load profile appears. With this
command alphaSET shows all load profile data of the meter in a table.
The following data are listed:
Date
Time
Measured values of the channels (up to 8 channels)
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
19/52
Status of the saved measuring periods.Image 6-4-2: Data of load profile
The status-announcement is shortened, if several channels are parameterised, in
accordance with:FE:
Fatal fault
CS:Backup time of real time clock exhausted
MD:
Measuring period disturbed (shorter measuring period)
SC:
Season change
RS:
Reset
CC:
Device clock
PU:
Power return
PF:Power failure
Page 37alphaSET, user manual, Version 2.05.00
Page 37 of 111
6 Read meter data
Reading of large amounts of LP-data: Only 1000 entries can be displayed in one chart. To
view advanced data, click previous values or following values.
Comment to the user profile Railway: A train number is additionally indicated in the
depiction of the load profile values in the user profile "Railway:
Comment to read load profile without header: You have the possibility to read load
profile, without reading previously information of the meter. For this and for more information
concerning settings see chapter 5.
6.4.1 Graphical display of load profile data
With the selection show load profile you get the data of the meter in a table and additionally a
button to show this information graphically.
With this button you start the LP Analyzer tool and you get directly the following picture.Image 6-4-2: Graphical data of load profile
Page 38alphaSET, user manual, Version 2.05.00
Page 38 of 111
6 Read meter data
The following icons are available for the user:
Back to the main window
Print
Change of scale of the y-axis
Maximum x-axis
Maximum y-axis
Maximum x-axis and y-axis
Additionally it is possible to zoom in. You just have to click in the graph and pull with the
mouse, to mark of the area you want to see in more details.
At the bottom the values of the load profile data is listed.
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
20/52
Image 6-4-2: Table settings 1
It is possible to show maximum of 8 channels. With the checkbox your are able to activate /
deactivate the channels in the graph.
If you double click on the field of the colour, you are able to choose different colours and types
of designs.
Page 39
alphaSET, user manual, Version 2.05.00Page 39 of 111
6 Read meter data
To analyse in detail specific values of the load profile, you have to set the cursor to this line in
the table of load profile date and then in the graph this position is displayed. Have a look at the
next picture.Image 6-4-2: Table settings 2
Page 40alphaSET, user manual, Version 2.05.00
Page 40 of 111
6 Read meter data
6.5 Read power quality monitoringSelect via Meter the menu point Read power quality monitoring.Image 6-5-1: Read power quality monitoring
The power quality profile of the meter can be read with this command.
Structure and function mode are identically to chapter 6.4
Read load profile .
Page 41alphaSET, user manual, Version 2.05.00
Page 41 of 111
6 Read meter data
6.5.1 Graphical display of power quality data
With the selection Show power quality monitoring you get the data of the meter in a table andadditionally a button to show this information graphically.
With this button you start the LP Analyzer tool and you get directly this following picture.Image 6-5-1: Graphical data of power quality monitoring
Structure and function mode are identically to chapter 6.4.1 Graphical display of load profile
data.
Page 42alphaSET, user manual, Version 2.05.00
Page 42 of 111
6 Read meter data
6.6 Read log fileSelect via Meter the menu point Read log file or the following icon:
Image 6-6-1: Read logfileStructure and function mode are identically to chapter 6.4
Read load profile.
The representation of the logfile contains the date, the time and the event.
According to the parametrization of the meter, one receives following entries:
Power failure (3-phase or per phase)
Power return (3-phase or per phase)
Adjusting the time
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
21/52
Functional error in the meter
Demand reset
Reset load profile and logbook
Change energy/demand-tariff
Backup time of real time clock exhausted
Parameter change
Season change terminal cover removal detection
reverse run detection
Page 43alphaSET, user manual, Version 2.05.00
Page 43 of 111
6 Read meter dataImage 6-6-2: Data from logfile
6.7 Read log file 2Select via Meter the menu point Read log file 2.
With FW 5.20 of the A1350 and FW 7.00 of the A220 a second log file can be activated in the
meter. In that case the following last 30 events can be read with alphaSET:
change of meter configuration
register reset
load profile reset
instrumentation profile reset
set time & date
Page 44alphaSET, user manual, Version 2.05.00
Page 44 of 111
6 Read meter data
6.8 Read meter error statusSelect via Test the menu point Read meter error or the following icon:
Image 6-7: Read meter error status
With the reading of the error status of the alpha meter, the possible error messages are listed.
If a malfunction of the meter exists, this is indicated through a large red box in front of the error
message. Little green boxes indicate on the other hand that no error exists.
In this window the following two buttons can be used:
Close
The window closes and leads back to the main window
Read meter error
Reads the meter once again
Page 45alphaSET, user manual, Version 2.05.00
Page 45 of 111
6 Read meter data
6.9 Read communication protocolSelect via test the menu point Communication protocol or the following icon:
If you choose this menu point, you can see the protocol of the last communication between
alphaSET and the meter.Image 6-8-1: Read communication protocol
It is also possible to view old communication protocols of alphaSET. You just have to click on
the date and time row on the left hand side and you will get this protocol.
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
22/52
Page 46alphaSET, user manual, Version 2.05.00
Page 46 of 111
7 Configuration of the meter
7 Configuration of the meter7.1 Open of a parameter fileSelect via File the menu point Read parameter or the following icon:
If you choose this menu point, you can open the following files directly:Image 7-1-1: File - Read parameter
7.2 Save a parameter setSelect via File the menu point Save or the following icon:
This command enables the saving of the reading data over a dialogue window.
Parameter file:
The file is saved by standard with the ending .par.
Register content:
The file is saved by standard with the ending .rg.
Load profile content:
The file is saved by standard with the ending .lp
.
Log file entries:
The file is saved by standard with the ending .log
.
Switch programs:
The file is saved by standard with the ending .uhr
.
Comment:
You can only save, if you have previously read the corresponding data. (Screen display).
Page 47alphaSET, user manual, Version 2.05.00
Page 47 of 111
7 Configuration of the meter
7.3 Configuration of a meter by using a configuration fileSelect via File the menu point
File with parameter -> meter
.Image 7-3-1: File with parameter ->meter
7.3.1 Switch point clock
With this menu, the settings of the switch point clock can be loaded out of a switch program-
file (ending: .uhr) and will be sent into the meter.The Utility password is required before the start of the communication.
Note: The internal structure of the Switch point clock remained in the A1500 or A1350
same as in the AEM500 meter. If the file, that is to be loaded to the meter, contains only one
switch point clock, the obligatory check of the firmware version is cancelled. Therewith can
even old switch point clock programs be loaded without problem to the new meter.
It is to be respected generally on that, which the day types, the energy tariffs and the
maximum tariffs of the meter also agree with the switch point clock program.
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
23/52
7.3.2 Settings (without PW + ID)
With this menu all setting parameters (parameters which can be changed without breaking the
certification seal), except password and identification, can be loaded of a parameter file
(ending: .par) and be sent to the meter. After input of the file name, a window, in which date
Page 48
alphaSET, user manual, Version 2.05.00Page 48 of 111
7 Configuration of the meter
7.3.3 Settings and parameterisations (without PW + ID)
Icon in the icon bar:
With this menu, all setting and parameter-parameters (except password and identification) can
be loaded of a parameter file (ending: .par) and be sent to the meter. After input of the file
name, a window, in which date and time are indicated, appears. After confirming with OK, the
utility password is queried before the data are loaded into the meter.
Comment:
The parametrization-button must be pressed previously before the programming of the meter
starts.
7.3.3.1 Parameter-file WITHOUT calibration-data (without PW + ID)This menu point is a service function and to use only in consultation with ELSTER. Here are all
parameters (class 0 to 6) of the meter (except password and identification) are written, only
the calibration-data remain unchanged.
This process is only possible with a special ELSTER password and requires no renewed
calibration of the meter.
7.3.3.2 Parameter-file WITH calibration-data (without PW + ID)
This menu point is a service function and to use only in consultation with ELSTER. Here are all
parameters of the meter (except password and identification) written, also the calibration-data
are changed. This process is only possible with a special ELSTER password and requires a
new calibration of the meter.
7.4 Change of parametersWith the menu point Modify parameters of a meter or a file can be changed, saved, and
loaded again into the meter.
This menu point is first visible, if the configuration of the meter was read before (see chapter
6.3 Read settings), or a file was loaded directly (see chapter 7.1 Open of a parameter file).
The menu points in the upper section are setting parameters. The menu points in the lower
section are parameterisation parameter and requiring an activation of the parameterisation
button.
After an alteration, you have to confirm the respective menu point with OK in order to send
these new parameters to the meter. The following query appears:
Page 49alphaSET, user manual, Version 2.05.00
Page 49 of 1117 Configuration of the meterImage 7-4-1: Data transfer
With a Yes the data are written directly into the meter. With a No this process is not
executed, but that data are taken over into the database ofalphaSET.
This is the general flow in the change of parameters. The exact description to the single
parameters themselves follows in the following chapters.
Page 50alphaSET, user manual, Version 2.05.00
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
24/52
Page 50 of 111
8 Change of meter configuration
8 Change of meter configurationSelect the menu point Modify.Image 8-0: Menu point Modify
This menu point is first visible if the configuration of the meter was read before (see chapter6.3 Read settings) or a parameter set was read by a file.
The menu points in the upper section are setting parameters. The menu points in the lower
section are parameterisation parameter and requiring an activation of the parameterisation
button.
Note: The menu entries of Modify are depending to the firmware version of the meter.
Page 51alphaSET, user manual, Version 2.05.00
Page 51 of 111
8 Change of meter configuration
8.1 IdentificationsSelect via Modify the menu point Identifications.Image 8-1-1: Identifications
The following parameters can be modified in this window: Utility password 1
Utility-identification #1
Utility-identification #2
Utility-identification #3
Utility-identification #4
Utility-identification #5
Utility-identification #6
IEC 1107-identification (=Answer of the meter on the request telegram)
e.g. : read register
S: 13:36:29,09 -- /?!
E: 13:36:30,43 -- /ABB5\@V4.10
S: 13:36:30,64 -- 050
E: 13:36:31,17 -- 1-1:F.F(00000000)
Page 52alphaSET, user manual, Version 2.05.00
Page 52 of 111
8 Change of meter configuration
Note: \ and @ are firmly given indications, 14 further indications can be
parametrized by the user.
IEC 1107-address #1 (opt.)
IEC 1107-address #2 (electr. 1)
IEC 1107-address #3 (electr. 2)
e.g. : read register
S: 13:54:05,78 -- /?0000001234567890!
E: 13:54:07,67 -- /ABB5\@1234567
S: 13:54:07,87 -- 050
E: 13:54:08,40 -- 1-1:F.F(00000000)
After clicking the button OK the following security query appears Do you want to transfer the
modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
25/52
menu, the data are however saved in alphaSET. Cancel" causes the leaving of the window.
Note: With the IEC1107 address the leading zeros or blanks are suppressed. They are sent to
the meter by alphaSET, but the meter ignores them.
Page 53alphaSET, user manual, Version 2.05.00
Page 53 of 111
8 Change of meter configuration
8.2 Tariff sourceSelect via Modify the menu point Tariff source.Image 8-2-1: Tariff source up to FW 4.01
Image 8-2-2: Tariff source from FW 4.10
Starting with the firmware version 4.10 it is possible to set the tariff source independently for
energy and demand. Three options are available here:
External control inputs
Internal ripple receiver
Internal switch point clock
By clicking on the button OK appears the security query Do you want to transfer the
modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the
menu. Cancel" causes the leaving of the window.
Page 54alphaSET, user manual, Version 2.05.00
Page 54 of 111
8 Change of meter configuration
8.3 Switch point clockSelect via Modify the menu point Switch point clock.
The settings of the switch point clock in the meter can be indicated and changed here.
8.3.1 Day type
Select via Modify the menu point Switch point clock -> day type.Image 8-3-1: Menu Switch point clock
The weekdays can be summarized to corresponding groups in the field day type. Theselection of the types takes place via the activation of the corresponding boxes. The fields with
the designations day type 1/2/3/4 can be edited.
An eight-place switch-program-number is assigned to each switch-program in the
corresponding field, which can be modified. All chars, which can be displayed in the 7-
segment-display of the meter ( 0..9,A,C,E,F,H,J,L,P,S,V,Y), are valid. In the field comment
exists the possibility to enter free text. Though, this is not written in the meter, but only in the
saved file.
With the command save as file the switch-program can be saved. The command read from
file loads an existing switch-program (file with the ending .uhr).
The command print prints the complete switch-program including day-type- and season-
definitions.
Page 55alphaSET, user manual, Version 2.05.00
Page 55 of 111
8 Change of meter configuration
By clicking on the button OK appears the security query Do you want to transfer the
modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the
menu.
Cancel" causes the leaving of the window.
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
26/52
8.3.2 Season change
Select via Modify the menu point Switch point clock -> Season change.Image 8-3-2: Season change
In the field seasons the number of the seasons can be defined as well as their start date (the
field of the seasons name can be edited).
1, 2 or 4 seasons can be arranged and distributed as desired over a total calendar year. They
can even occur repeatedly in the total calendar year.Procedure: To register a season in the calendar, the field season 1 must be clicked (above
green). Subsequently a black arrow marks the activation. Now clicking on the corresponding
days must mark only the beginning and ending day of the season. With this menu structure,
arises a higher flexibility, which permits for example to bind switch-programs of the season 1
within the season 3 of the 9.-16. July.
Page 56alphaSET, user manual, Version 2.05.00
Page 56 of 111
8 Change of meter configuration
8.3.3 Tariff switch table
Select via Modify the menu point Switch point clock -> Tariff switch table.Image 8-3-3: Switching timesIn this submenu are the actual settings of the different switching times taken. In the indicated
table stands T for energy tariff, M1 until M4 for the different demand tariffs, R1 and R2
for the two output relays (as far as these functions are parameterised like this).
The different energy and demand tariffs can now be assigned individually to the switching
times and their validity (defines over the season and the day type).
The following buttons are available:
Release locks: The check of alphaSET, whether T1-T4, M1-M4 and relay 1/2 are valid is
unmade. Recommendation: Let this checkbox always deactivated.
Accept: The changes concerning the selected switching time are transferred into the table.
New: A new switching time is transferred into the table. The time of an available entry must
be blocked first to be able to carry out this function.
Delete: A designed entry is removed from the table.
Comment: To each season and to each day type, a time entry is generated automatically at
00:00 clock. The user has to indicate the corresponding energy and/or demand tariff.
Page 57alphaSET, user manual, Version 2.05.00
Page 57 of 111
8 Change of meter configuration
8.3.4 Holiday-list
Select via Modify the menu point Switch point clock and there the register card Holiday-
list.Image 8-3-4: Holiday-list
All defined holidays are displayed in the table.With the pull-down-menu holiday list the selection of already recalculated holidays can be
activated.
The number of years, which should be calculated for each holiday, is indicated in the field
"years". According to the number of the switching times and holidays, ca. 15 years can be
saved in advance.
With the check box cyclic one receives the possibility to define recurring holidays (e.g. 01.01.
-> new year). If this option is not selected, one receives the possibility to indicate day, month
and year of a fixed holiday (e.g. Easter Sunday).
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
27/52
The following buttons are available:
Accept: The changes concerning the selected holiday are transferred into the table.
New:
A new holiday is transferred into the table.
Delete: A designed entry is removed from the table.
Page 58alphaSET, user manual, Version 2.05.00Page 58 of 111
8 Change of meter configuration
8.3.5 Daylight saving time
Select via Modify the menu point Switch point clock -> Daylight saving time.Image 8-3-5: Summer/winter time switch
In this menu can the summer/winter time-switch either be deactivated, aligned at the EU
standard or, in the setting "user defined", be defined in the indicated tables.
Page 59alphaSET, user manual, Version 2.05.00
Page 59 of 111
8 Change of meter configuration8.4 Switch point clock (Update)Select via Modify the menu point Switch point clock (Update).
A second switch point clock can be defined in the meter (with FW 5.10 of A1350 and FW 7.00
of A220). At a predefined date the second tariff table will be activated and valid for the rest of
the time. All data have to be defined in the same way as the first switch timetable.
8.4.1 Day type
Select via Modify the menu point Switch point clock (Update) -> day type.Image 8-4-1: Second tariff table
Date of update
The activation date (at 00:00) of the second tariff table has to be defined here.
Page 60alphaSET, user manual, Version 2.05.00
Page 60 of 111
8 Change of meter configuration
8.5 TimesSelect via Modify the menu point Times. Different possibilities to change the time base or
communication timeout are offered:
8.5.1 Source of Times
Select via Modify the menu point Times -> Source of time.Image 8-5-1: Real time clock
In this menu the user can define whether the network frequency or the quartz frequency is
supposed to be used for the time of the internal real time clock of the meter.
Notes: In general, the setting quartz is to be recommended because the quartz inserted are
highly exact and temperature stable (< 5 ppm).
Especially in use of a DCF-synchronization of the measuring period is it recommended to
select the setting quartz. This is because the network frequency can vary and it can lead
therefore to undesirable time set (in synchronization) with corresponding entries in the
load profile.
It is recommended to use line for meters that are not synchronized, because the
temporal deviations are countervailed with the time. Therewith, the time doesnt run
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
28/52
away.
Whether these parameters are set parameters or parameterisation parameters depends
on the firmware version of the meter which works at the moment with the alphaSET: Until
including FW version 3.05 these are parameterisation parameters, from FW version 4.00
these are set parameters.
Page 61alphaSET, user manual, Version 2.05.00
Page 61 of 111
8 Change of meter configuration
By clicking on the button OK appears the security query Do you want to transfer the
modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the
menu.
Cancel" causes the leaving of the window.
8.5.2 Display Timeouts
Select via Modify the menu point Times -> Display Times.Image 8-5-2: Display timeouts
In this menu the user can define the display scroll time and the timeout for the alternate mode.
After the alternate time out exceeds the limit, the meter goes back automatically in the scroll
mode.
Page 62alphaSET, user manual, Version 2.05.00
Page 62 of 111
8 Change of meter configuration
8.5.3 Communication Timeouts
Select via Modify the menu point Times -> Communication Times.Image 8-5-3: GPRS communication timeout
Notes:
According the IEC1107 standard the maximum communication timeout between 2
characters is 1,5s.
For GPRS application the maximum timeout between 2 characters has to be increased.
The suggestion is to use in that case a timeout of 6s.
Page 63alphaSET, user manual, Version 2.05.00
Page 63 of 111
8 Change of meter configuration
8.6 Demand resetSelect via Modify the menu point demand reset.Image 8-6-1: Demand reset
In this menu, the possible sources for the triggering of a maximum demand reset can be
released or blocked. Settings, which are not selectable, have a grey background. The day
within a month, at which the maxima demand reset should take place, can be defined with the
button every month on the... at 0.00 PM. Moreover the duration of the reset lock time can beadjusted. The reset lock time is only active by activation over the same reset lock source.
By clicking on the button OK appears the security query Do you want to transfer the
modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the
menu. Cancel" causes the leaving of the window.
Page 64alphaSET, user manual, Version 2.05.00
Page 64 of 111
8 Change of meter configuration
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
29/52
8.7 Overload thresholdSelect via Modify the menu point Overload threshold.Image 8-7-1: Overload threshold
The user has the possibility to configure one or two outputs of the meter, so that by exceeding
of a specific demand threshold an output contact is opened and/or closed. The overload
threshold 1 refers always to the measuring channel 1 of the meter. The overload 2 can be set
on every defined measuring channel of the meter. At the start of a demand period, the outputcontact is either opened or closed (if it is parameterised). By exceeding the threshold the
output contact is closed (opened).
Starting with the FW version 4.40 it is additionally possible to enter a threshold value for the
tan(phi).
Note: The format of the overload threshold is the same as for the demand values. Up to FW
version 4.00 only one overload threshold can be parameterised, since then two. Only since
firmware 4.20 is it possible to configure overload threshold 2 freely.
Page 65alphaSET, user manual, Version 2.05.00
Page 65 of 111
8 Change of meter configuration
8.8 Baud rateSelect via Modify the menu point Baud rateImage 8-8-1: Baud rate
In this menu the start baud rate or either the maximum baud rate of the meter can be selected,
separated between optical or electrical interface.
Further baud rates can be selected by a click on the pull-down-arrows.
With the FW version 4.40 of the A1500 a second electrical interface is available. For this case
it is possible to set the priorities of this interfaces.
Note: If the start baud rate of an interface in the meter is changed, the baud rate for the
communication must be changed after writing into the meter, too. (See chapter 4.1
Communication).
Page 66alphaSET, user manual, Version 2.05.00
Page 66 of 111
8 Change of meter configuration
8.9 SynchronizationSelect via Modify the menu point Synchronization.Image 8-9-1: Synchronization
In this menu the mode of the demand period synchronisation as well as the synchronisation of
the meter clock can be defined by using an integrated ripple receiver, an internal DCF77-clock
or an external control input.
The image offers the following adjustment possibilities:
None
To next interval: recommended if a control input (MPE Kl. 16) to the measuring periodsynchronization is used by an external synchronization pulse.
To next minute: recommended with reservation if an externally produced DCF pulse is
used by an external control input for the synchronization of the measuring period.
With interval to reference-time: recommended in synchronization over ripple receiver. In
selecting the point With interval to reference-time appears a menu, in which the reference
time and the time window of the synchronization can be adjusted.
Page 67
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
30/52
alphaSET, user manual, Version 2.05.00
Page 67 of 111
8 Change of meter configuration
Set date/time by DCF 77-antenna input: recommended by using the pulse input 1 as a
DCF77 antenna input. (A DCF77antenna must be connected to the pulse input 1). By
activation of this feature the internal meter clock will by synchronized every 5 minutes after
a full hour, after power up or by activation of the meter test mode.Note: After activation of the DCF 77 antenna input the meter will generate a warning
FF2 1000000 until a correct time/date information is decoded. A DCF77 decoding can be
activated by a formatted command too.
By clicking on the button OK appears the security query Do you want to transfer the
modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the
menu.
Cancel" causes the leaving of the window.
Note: DCF 77 decoding is available from meter with firmware version 4.00.
Page 68alphaSET, user manual, Version 2.05.00
Page 68 of 111
8 Change of meter configuration
8.10 Backup time of the real time clockSelect via Modify the menu point Backup time of real time clock.Image 8-10-1: Backup time of real time clock
In order to be able to build a battery into the meter subsequently, there is the possibility to
change the default settings from supercap to battery.
Note: This is first possible from FW version 4.00 of the meter. The rating plate of the meter
must be removed to install the Battery.
8.11 Inverting Inputs/OutputsSelect via Modify the menu point Inverting Inputs/Outputs .Image 8-10-1: Backup time of real time clock
With this menu it is possible to invert inputs and outputs by activating the checkboxes. This ispossible with firmware version 4.30 and higher.
Page 69alphaSET, user manual, Version 2.05.00
Page 69 of 111
8 Change of meter configuration
8.12 Power qualitySelect via Modify the menu point power quality.
8.12.1 Release of power quality functionalityImage 8-11-1: Release power quality values
In this menu you have the possibility to release the measurement of the power quality values,
which can then be read over the service list or which or are available for the power quality
profile.
Page 70alphaSET, user manual, Version 2.05.00
Page 70 of 111
8 Change of meter configuration
8.12.2 Load profile of power quality data
In this menu the settings of the power quality monitoring can be configured.Image 8-11-2: Power quality monitoring data
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
31/52
The following parameters can be assigned:
Assignment of load profile channel number and quantity
Storage type of every channel
Average value over the period of the power quality data
Minimum value inside the period of the power quality data
Maximum value inside the period of the power quality data
Duration of the load profile period (1..60min)Notes:
The max. Duration of the load profile of the power quality data depends on the duration of
the billing data load profile and cannot be changed in this menu. This duration depends on
the measure period and the number of channels.
The OBIS identifier for the load profile channels will be assigned automatically.
The different power quality measurements have to be activated in the menu Release
power quality values, to be used here.
Page 71alphaSET, user manual, Version 2.05.00
Page 71 of 111
8 Change of meter configuration
8.12.3 Power Quality Monitoring
In this menu the settings of the power quality monitoring can be configured.Image 8-11-3: Power quality monitoring
The following parameters can be assigned:
Assignment of power quality data to a register
Definition of a upper and / or lower limit
Measuring interval (1..60min)
The FW 5.10 and FW 4.40 offer additional features to observe the network regarding power
quality issues. Therefore up to 18 different counters with up to 18 thresholds can be activated
to detect the occurrence, if a power quality value is above or below a predefined threshold
during a user programmable period (1, 2, 3, 4, 5, 6, 10,12, 15,20, 30, 60 minutes).
Furthermore 2 log file events and 2 relay contacts can be activated if 1 or more events will be
above or below the predefined threshold.Additionally with the logic OR / AND operation you are able to combine the different
information of the thresholds.
Page 72alphaSET, user manual, Version 2.05.00
Page 72 of 111
8 Change of meter configuration
8.13 Copper-/Iron-lossesIn this menu the definitions for the transformer and line loss calculation can be configured.
This feature is only supported with the FW 4.30 of the A1500 and A2500.Image 8-12-1: Transformer and line losses
The following parameters can be assigned:
Constant R of the transformer loss calculation
Constant X of the line loss calculation
Decimals for the transformer loss register
Decimals for the line loss register
To display the transformer and line loss register on the LCD or optical/electrical interface the
value has to be assigned to the display list.
For the right function you have to select your nominal voltage and current of your meter. The
internal algorithm needs this information to calculate with the decimals the overflow boundary.
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
32/52
Page 73alphaSET, user manual, Version 2.05.00
Page 73 of 111
8 Change of meter configuration
8.14 Display
The parameter settings of the display are divided in two menu points. Service list
Dispay parameter
Note: With the FW version 4.20 a second settable display list (service list) was added to the
meter.
8.14.1 Service list
Select via Modify the menu point Service list.Image 8-13-1: Service list
This service list is additional to the alternate list. In the display of the meter you will find it via
the symbol Abl-data. Basically the list is blocked, but can be released since firmware version
4.10 of the meter by selecting the checkbox "The service-list IS released.
The handling of this service list is identical with chapter 8.14.2.1 Display list with the
exception that there is no display of data in the scroll mode.Page 74
alphaSET, user manual, Version 2.05.00
Page 74 of 111
8 Change of meter configuration
Explanation:
No.:
Consecutive number (automatically set).
Me:
medium of the displayed value
Ch
channel number of the displayed value
ID-Code:
ODIS-ID (firmly assigned after standard)
wU:
Display with Unit (freely selectable)
AM:
Display in alternate mode (freely selectable)
wP:
Display with historical billing data (freely selectable)
SP:
Display (with historical values) in the display sequence (scroll-historical-
Values) (freely selectable)
D1:Display date/time in one line (firmly assigned through parameter set)
op:
Output over optical interface (freely selectable)
el:
Output over electrical interface (freely selectable)
Description: Explanation to the display value
The following buttons are required for changing the display table:
Creating a new entry in the display table.
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
33/52
Copying of the marked area of the display table (also
new entries can be generated on this basis)
Takes the changes over into the indicated display table
Automatic sorting of the table
Deletes the marked display entry
Page 75alphaSET, user manual, Version 2.05.00
Page 75 of 111
8 Change of meter configuration
8.14.2 Display parameter
8.14.2.1 Display list
Select via Modify the menu point Display parameter -> Display list.Image 8-13-4: Display list
The register values with the associated IDs can be selected here. It is possible to chose scroll-
mode (SM), alternate mode (AM), the optical (OP) and/or electric interface (EL).
The handling of this service list is identical with chapter 8.14.1 Service list with one addition:
SM:
Display in scroll-mode (freely selectable)
Page 76alphaSET, user manual, Version 2.05.00
Page 76 of 111
8 Change of meter configuration
8.14.2.2 General settings of the display
Select via Modify the menu point Display parameter and there the register card Control.Image 8-13-6: Settings of the display
In this menu you are able to set the following parameters:
total number / number of digits / unit for the energy register data
total number / number of digits / unit for the demand register data
total number / number of digits / unit for the cumulative register data
using medium&channel for OBIS identifier
reading data with/without units
time&date format
Page 77alphaSET, user manual, Version 2.05.00
Page 77 of 111
8 Change of meter configuration
8.14.2.3 Configuration of historical values
Select via Modify the menu point Display parameter and there the register card Hist.
Values.Image 8-13-7: Configuration of historical values
In this menu can the maximum number of historical values and the number of values for the
different medium (optical/electrical interface or alternate list) be defined.
Page 78alphaSET, user manual, Version 2.05.00
Page 78 of 111
8 Change of meter configuration
8.15 Pulse constantsSelect via Modify the menu point Pulse constants.Image 8-14-1: Transformer ratio
The user is able to select the measurement type: secondary or primary measurement. By
-
7/30/2019 Download ELSTER Energy Meter-Kar Key
34/52
using the primary measurement the current and voltage transformer ratio is included in the
energy and demand measurement results of the meter.
Furthermore it is possible to define the pulse constant of the LED and the relay output of the
meter.
Additionally the pulse duration of the pulse output can be defined in multiple of 8ms.
Page 79alphaSET, user manual, Version 2.05.00
Page 79 of 111
8 Change of meter configuration
8.16 Pulse inputsSelect via Modify the menu point pulse inputsImage 8-15-1: Pulse inputs
The user has, by standard, 1 pulse input at disposal (with disuse of the DCF-input). 2 further
pulse inputs can be used if an optional conductor board is used in the meter. The inputs
accord to the SO-standard. An own pulse constant can be assigned to the pulses of the pulse
inputs. The summation of the input pulses is stored in a separate register and is included in
the standard reading list of the meter.
The following functions are available:
Measuring period synchronization input, which must be controlled by a relay (Attention!
No connection to 230V possible).
Check of opening terminal cover (optional): A removing of the terminal cover can be
detected with this input. A reed relay is positioned at the terminal cover, which bypasses
the input. If the cover is removed, an entry in the log file occurs and the corresponding
meter is incremented. A warning appears in the display, which can only be removed by
using the interface.
F.F.1: 00010000
Pulse input: pulse constants and number of decimals are freely selectable.
Summation input for measuring block 3: The pulse input could be added to the register of
measuring block 3. The pulse constant is freely selectable; measuring block 3 specifies the
number of decimals.
Note: Pulse input 1 can also be used as DCF-input and is then deactivated at this place.
Page 80alphaSET, user manual, Version 2.05.00
Page 80 of 111
8 Change of meter configuration
8.17 Load profile / logfile - parameter
8.17.1 Load profile parameter
Select via Modify the menu point Load profile / log-book parameter.
In the first register card the measuring quantities can be assigned to the load profile channels.
A plausibility check of the parameters takes place before the image appears:
Are all necessary parameters for the parametrization loaded into the alphaSET?
Is the load profile generally released?
Is the load profile released in the type key?
Is a VDEW-load profile parametrized?
The form is not indicated and an error message appears instead, if one of these tests leads to
a negative result.Image 8-16-1: Load profile parameter
The final layout of the wi