    Reading and Configuration tool

    alphaSETInstruction manualVersion:

    2.05.00

    Date:

    11/10/06

    Document name:

    alphaset_user_manual_GBR.doc

    Page 2alphaSET, user manual, Version 2.05.00

    Page 2 of 111

    1 Overview

    COPYRIGHT

    Copyright 2006 ELSTER Messtechnik GmbH. All rights reserved.

    All rights, also those the translation, the reproduction and the duplication of the document, or

    parts from it, reserved. No part of the document may be multiplicated without written

    permission of the ELSTER Messtechnik GmbH in any form (electronically, mechanically,

    photographically or another procedure) or be spread.

    Printed in Germany

    Attention

    ELSTER Messtechnik GmbH reserves itself the right to carry out changes in all products

    described in this manual to improve reliability, function or design. Specifications and

    information, which are described here, can change without notification. Not all occurrences,with all possible details and variations of the devices, which can appear during the installation,

    the use and maintenance, are covered by this manual

    ELSTER will not be responsible for errors in this document or for consequential damages in

    the reference to mechanism, achievement or use of this material.

    ELSTER does not take any responsibility and adhesion for the installation, use, achievement,

    care and support of products third.

    For further information, see the following references:

    ELSTER Electricity meter customer support:

    +0049 (0) 6206 933 339

    ELSTER Electricity meter customer support e-mail:

    [email protected]

    ELSTER company web site:http://www.elster.com

    ELSTER Electricity meter web site:

    http://www.elstermetering.com

    Page 3alphaSET, user manual, Version 2.05.00

    Page 3 of 111

    1 Overview

    https://mail-attachment.googleusercontent.com/attachment/?view=att&th=12d37947f52f27b9&attid=0.1&disp=attd&zwmailto:[email protected]://www.elster.com/http://www.elstermetering.com/https://mail-attachment.googleusercontent.com/attachment/?view=att&th=12d37947f52f27b9&attid=0.1&disp=attd&zwmailto:[email protected]://www.elster.com/http://www.elstermetering.com/
  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    2/52

    Table of contents1

    Overview...............................................................................................................................6

    1.1 System overview...............................................................................................................6

    1.2 Document history ..............................................................................................................6

    2Referenced documents .......................................................................................................7

    3

    Introduction / brief description...........................................................................................8

    3.1 What is the alphaSET tool ?..............................................................................................8

    3.2 System requirements ........................................................................................................8

    3.3 Installation / Update ofalphaSET......................................................................................9

    3.4 Start of the software and user-profile..............................................................................13

    3.4.1 First start after installation........................................................................................13

    3.4.2 User-profile ..............................................................................................................15

    3.4.3 Use of the software.................................................................................................17

    3.5 Indication of the software version....................................................................................20

    4

    User settings ......................................................................................................................21

    4.1 Communication ...............................................................................................................21

    4.1.1 Remarks to the user-profile Railway......................................................................23

    4.2 Modem ............................................................................................................................24

    4.2.1 Initialization strings...................................................................................................25

    4.3 Files.................................................................................................................................25

    4.4 Read register...................................................................................................................26

    5

    Load profile ........................................................................................................................27

    5.1 General Settings .............................................................................................................28

    5.2 User language.................................................................................................................29

    5.3 IEC 1107-Address...........................................................................................................30

    5.4 Change utility password..................................................................................................30

    6

    Read meter data.................................................................................................................31

    6.1 Read register list .............................................................................................................31

    6.2 Read service list..............................................................................................................32

    6.3 Read settings ..................................................................................................................33

    6.4 Read load profile.............................................................................................................35

    6.4.1 Graphical display of load profile data.......................................................................37

    6.5 Read power quality monitoring........................................................................................40

    6.5.1 Graphical display of power quality data ...................................................................41

    6.6 Read log file ....................................................................................................................42

    6.7 Read log file 2 .................................................................................................................43

    6.8 Read meter error status ..................................................................................................44

    6.9 Read communication protocol.........................................................................................45

    7

    Configuration of the meter................................................................................................46

    7.1 Open of a parameter file .................................................................................................46

    7.2 Save a parameter set......................................................................................................46

    7.3 Configuration of a meter by using a configuration file.....................................................47

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    3/52

    7.3.1 Switch point clock ....................................................................................................47

    7.3.2 Settings (without PW + ID).......................................................................................47

    7.3.3 Settings and parameterisations (without PW + ID) ..................................................48

    7.4 Change of parameters ....................................................................................................48

    8

    Change of meter configuration.........................................................................................50

    8.1 Identifications ..................................................................................................................51

    8.2 Tariff source ....................................................................................................................53

    Page 4alphaSET, user manual, Version 2.05.00

    Page 4 of 111

    1 Overview

    8.3 Switch point clock............................................................................................................54

    8.3.1 Day type...................................................................................................................54

    8.3.2 Season change........................................................................................................55

    8.3.3 Tariff switch table.....................................................................................................56

    8.3.4 Holiday-list ...............................................................................................................57

    8.3.5 Daylight saving time.................................................................................................58

    8.4 Switch point clock (Update).............................................................................................59

    8.4.1 Day type...................................................................................................................59

    8.5 Times ..............................................................................................................................60

    8.5.1 Source of Times.......................................................................................................60

    8.5.2 Display Timeouts .....................................................................................................61

    8.5.3 Communication Timeouts ........................................................................................62

    8.6 Demand reset..................................................................................................................63

    8.7 Overload threshold..........................................................................................................64

    8.8 Baud rate.........................................................................................................................65

    8.9 Synchronization...............................................................................................................66

    8.10 Backup time of the real time clock ................................................................................68

    8.11 Inverting Inputs/Outputs................................................................................................68

    8.12 Power quality.................................................................................................................69

    8.12.1 Release of power quality functionality ....................................................................69

    8.12.2 Load profile of power quality data...........................................................................70

    8.12.3 Power Quality Monitoring .......................................................................................71

    8.13 Copper-/Iron-losses.......................................................................................................72

    8.14 Display ..........................................................................................................................73

    8.14.1 Service list..............................................................................................................73

    8.14.2 Display parameter ..................................................................................................75

    8.15 Pulse constants.............................................................................................................78

    8.16 Pulse inputs...................................................................................................................79

    8.17 Load profile / logfile - parameter ...................................................................................80

    8.17.1 Load profile parameter ........................................................................................80

    8.17.2 Log file parameters...............................................................................................81

    8.18 Energy / Demand measuring ........................................................................................82

    8.19 Show settings................................................................................................................82

    8.20 Meter Access Rights .....................................................................................................83

    8.21 Passwords.....................................................................................................................85

    9

    Formatted Meter Commands ............................................................................................86

    9.1 Set meter date/time using the W2 command..................................................................87

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    4/52

    9.2 Read and Set time/date using the VDEW command ......................................................88

    9.3 Setting of pulse constants...............................................................................................89

    9.4 Setting of outputs ............................................................................................................90

    9.5 Activation of DCF 77 signal decoding .............................................................................91

    9.6 Reset maximum demand ................................................................................................92

    9.7 Reset meter error status .................................................................................................93

    9.8 Reset power quality profile..............................................................................................949.9 Reset power-loss counter ...............................................................................................95

    9.10 Reset terminal cover open counter ...............................................................................96

    9.11 Reset register................................................................................................................96

    9.12 Set register values (pulse inputs)..................................................................................97

    9.13 Reset load profile + logbook..........................................................................................98

    10

    Integrated Ripple receiver (LCR) ....................................................................................99

    11

    Test..................................................................................................................................100

    11.1 Read meter error.........................................................................................................100

    Page 5alphaSET, user manual, Version 2.05.00Page 5 of 111

    1 Overview

    11.2 Power-Quality..............................................................................................................101

    11.3 Test mode ...................................................................................................................103

    12

    Modem ............................................................................................................................105

    12.1 Phone book.................................................................................................................105

    12.1.1 Creating a new phone number .............................................................................106

    12.1.2 Changing a phone book entry ..............................................................................106

    12.1.3 Creating a new telephone book or save an existing one......................................106

    12.2 Hang up.......................................................................................................................10612.3 Dial-up doesnt work ! What to do? .............................................................................107

    13

    Extras..............................................................................................................................108

    13.1 Restrict menu system..................................................................................................108

    14

    Image index ....................................................................................................................110

    Page 6alphaSET, user manual, Version 2.05.00

    Page 6 of 111

    1 Overview

    1 Overview1.1 System overviewThis document describes the operation, the functional way and the installation as well as the

    technical data of the software tool alphaSET version 3. This tool was refined on the basis from

    alphaSET version 2 and is compatible to former versions.

    Therefore the following products can be served with this tool:

    AEM500

    ARM500

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    5/52

    AEM550

    A220

    A1350

    A1500

    A2500

    1.2 Document historyVersion:

    2.05.00

    Date:

    11/10/06

    Document name:

    alphaset_3_instruction_manual_GBR.

    Product Manager:

    ELSTER / RIM DEEM Dr. Gerhard Eisenbei

    Version Valid up to

    alphaSET

    version

    Valid up toFW-Version

    Changes

    Date

    Author

    2.01.00 3.03-xx

    4.10

    -Initial Version

    30/10/02 Thomasberger

    2.02.00 3.04-xx

    4.20

    - Adaptations to FW

    4.2020/08/03 Dr. Eisenbei

    2.03.00 3.06-xx

    4.20 and 5.00

    - Adaptations to FW

    5.00

    24/02/04 A. Aching

    2.04.00 3.09-xx

    4.30 and 5.10

    - Adaptations to FW

    4.30 and 5.10

    12/05/05 Dr. Eisenbei

    2.05.00 3.12-xx4.40, 5.30, 7.00 - Adaption to FW

    4.40, 5.20, 5.30, 7.00

    11/10/06 Thomasberger

    Page 7alphaSET, user manual, Version 2.05.00

    Page 7 of 111

    2 Referenced documents

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    6/52

    2 Referenced documentsTitle

    Version

    Date

    AEM_PR_D_1.pdf

    1KGL 921500 V004D 11/05/2001

    A1500_PR_E.pdf

    R 1.14

    06/16/2006

    A1350_PR_E.pdf

    R 1.17

    07/16/2006

    A220_PR_E.pdf

    R 1.06

    06/28/2006

    Zhlerstandsbertragung, Tarif- und Last-

    steuerung;

    Datenbertragung fr festen und mobilen AnschluDIN EN 62056-21

    01.03

    Elektronische Elektrizittszhler

    VDEW-Lastenheft

    V2.0

    12.97

    Page 8alphaSET, user manual, Version 2.05.00

    Page 8 of 111

    3 Introduction / brief description

    3 Introduction / brief descriptionThe following section should help to clear basic questions to the alphaSET tool:

    What is the alphaSET tool ?

    What are the system requirements for the use of this software ?

    How do I install this software ?

    What must I do if I would like to update this software ?

    How do I start the software ?

    What will I see, if I start the software ?

    How do I find out, which user profile may execute which action?

    How do I find out, which software version I use ?

    How do I set a password for the communication with the meter?

    Additional information:

    For additional information please refer to the product descriptions of the alpha meters (2

    Referenced documents).

    3.1 What is the alphaSET tool ?The alphaSET tool is a Windows based software to read the data of the alpha meters

    AEM 500 / ARM 500 / AEM 550 / A1350 / A1500 / A2500 and A220 (register, load profile, log

    book, etc.). Different parameters like setting and parametrization parameters can be

    changed according to user's profile. Setting parameter is those attitudes, which can be

    changed without breaking the certification seal. To get an access to the parameterisation

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    7/52

    parameters of the meter, a parameterisation-switch must be pressed which is via the

    calibration mark.

    The program is a 32 bit application, being based on a 32 bit environment that runs via

    Windows NT 4. X, as well as via Windows XP and Windows 2000.

    3.2 System requirementsSubsequet are the requirements for the use of the alphaSET software listed:

    IBM PC or compatible PC with 800 MHz Pentium or higher with the following equipment

    :-

    >=16 MB RAM-

    CD ROM disk drive-

    at least one free, serial interface (COM1 to COM16)-

    >=50 free hard disk memory

    Hardware components for communication-

    IEC 61107-compatible optical probe for the optical interface-CL0 Converter and RS232 cable for the electric interface (CL0-Interface)-

    RS232 cable for the RS232 interface (optional)

    Windows 2000 / NT / XP

    Monitor with a resolution of at least 600x800 pixel

    Page 9alphaSET, user manual, Version 2.05.00

    Page 9 of 111

    3 Introduction / brief description

    3.3 Installation / Update ofalphaSET

    You require administrator rights on your PC for the installation of this software-tool.Further it is urgently recommended that you close all windows programs, before starting the

    setup. Insert the CD-Rom with the procut information and tools from ELSTER to your CD-

    ROM-drive. Automatically the following menu is displayed. Please select your language and

    then press the button alpha meter.Image 3-3-1: Installation choose alpha meter

    Select in the section AlphaSET the button Installation.Image 3-3-2: Installation choose installation

    Page 10alphaSET, user manual, Version 2.05.00

    Page 10 of 111

    3 Introduction / brief description

    Within the next menu you have to choose the language of your setup.

    Image 3-3-3: Installation choose language

    AlphaSET is preparing the setup and you have to choose next here.Image 3-3-4: Installation information1

    Page 11alphaSET, user manual, Version 2.05.00

    Page 11 of 111

    3 Introduction / brief description

    Choose the button next.Image 3-3-5: Installation information2

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    8/52

    Select your destination path of alphaSET and press the button Next.Image 3-3-6: Installation select destination

    If you update the program, no deinstallation of the old version is necessary. You can simply

    install the new version in the same directory.

    Page 12alphaSET, user manual, Version 2.05.00

    Page 12 of 1113 Introduction / brief descriptionImage 3-3-7: Installation - phone book

    You should only secure your phone book, if you have one in a former version.

    Further information in chapter 12.1.3 Creating a new telephone book or save an existing one".

    SETUP checks now whether sufficient memory is available.

    Subsequently a communication window appears in which the installation progress is indicated.Image 3-3-8: Installation - Progress

    After completion a window appears with the information that SETUP generates program

    symbols. After successful installation a message from SETUP appears.Image 3-3-9: SETUP successfull

    Page 13alphaSET, user manual, Version 2.05.00

    Page 13 of 111

    3 Introduction / brief description

    Note:

    To secure all functions of the program alphaSET needs at least one installed Windows system

    printer, even if no printer is connected.

    According to your windows version, you have now a program group, or a start symbol of

    alphaSET

    3.4 Start of the software and user-profileTo start the alphaSET tool software:

    Chose in the Windows Start Menu > Programs > alphaSET > alphaSET

    Or click on the Icon on your desktop

    To close the software choose File -> Quit3.4.1 First start after installation

    With the first start after installation of the alphaset sofware the following window will be

    displayed:Image 3-3-10: Start - language

    Here please select the language to operate the tool.

    With the following menu it is possible to take over all the settings from prior versions of your

    computer.

    Page 14alphaSET, user manual, Version 2.05.00

    Page 14 of 111

    3 Introduction / brief descriptionImage 3-3-11: Start old settings

    Page 15alphaSET, user manual, Version 2.05.00

    Page 15 of 111

    3 Introduction / brief description

    3.4.2 User-profile

    AlphaSET starts with the menu of the profiles.Image 3-4-1: Input user-profile

    Each of this profiles has different privileges, that means possibilities of access on the menu

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    9/52

    system ofalphaSET. The user profiles are filed in the path " \ IniPfad ". If only one profile is in

    this path, this is started automatically, without showing the menu illustrated above. If no profile

    is in this path, the invisible profile "consumer" starts automatically, which has lowest privileges.

    The user profile serves the storage of all individual settings. If several persons work with a

    computer, each user can save his own settings, in order to fall back on them, if he uses again

    alphaSET. For information to the storage of an user's profile see chapter 4.1 "Communication".

    3.4.2.1 User-Profile "Railway:The user profile "Railway" is planned for applications of the train meter ARM500 and A1500.

    The user has to select in the menu extras -> options -> communication the point railway

    meter (only difference: 4800 start baud rate).

    Page 16alphaSET, user manual, Version 2.05.00

    Page 16 of 111

    3 Introduction / brief description

    3.4.2.2 Overview of user profile functionality

    User Profile

    alphaSET Software functions

    Meter reader

    Railway

    Installation

    Certificatio

    n

    Utility

    MO

    DE

    M

    Power Qual

    ity

    Read Meter

    Read register

    X X X X X X X

    Read load profile

    X X X X X X X

    Read logfile

    X X X X X X X

    Read meter configuration

    X X X X X X X

    Read meter error

    X X X X X X X

    Read service list

    X X X X X X XRead power quality monitoring

    X X X X X X X

    Change of parameters

    Change utility password

    X

    X X X

    File / read parameter

    X X X X X

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    10/52

    File with parameter -> meter

    X X X X X

    Identifications

    X

    X X X

    Tariff source

    X X X X XSwitch point clock

    X X X X X

    Times

    X

    X X X

    Demand reset

    X

    X X X

    Overload threshold

    X

    X X X

    Baud rate

    XX X X

    Synchronization

    X

    X X X

    Power Quality

    X

    X X X X

    Pulse inputs

    X

    X X X

    Backup time of real time clock

    X

    X X X

    Service List

    X

    X X X X

    Display parameter

    X

    X X X

    Pulse constants

    X

    X

    X

    Load-profile / logbook parameter

    XX

    X

    Measuring energy / demand

    X

    X X X

    Read/ Set pulse constants

    X

    X X X

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    11/52

    Meter commands

    Set meter date/time

    X X X X X X

    Read/set date/time

    X X X X X X

    Read out DCF clock

    X X X X X XReset demand maxima

    X X X X X X

    Reset meter error state

    X X X X X X

    Reset power-loss counter

    X

    X

    X X

    Reset register

    X

    X

    X X

    Reset load-profile and logbookX

    X

    X X

    General

    Switch to ripple receiver mode

    X X X X X X

    Test mode

    X

    X

    X X

    Communications protocols

    XX

    X XImage 3-4-2: User profile

    Page 17alphaSET, user manual, Version 2.05.00

    Page 17 of 111

    3 Introduction / brief description

    3.4.3 Use of the software

    After the selection of the user profile the alphaSET opening screen appears.Image 3-4-3: Opening screen

    The program alphaSET is a Windows - based application, which reflects the structure and the

    construction of Windows programs.

    The window of the main menu consists of The title bar

    The menu bar

    And the icon bar

    In the submenus are further windows (document windows and dialogue windows) indicated,

    which show the name of the submenu in the title bar. The menu bar indicates the available

    menus, in which the individual actions and switching functions are specified as clear text. This

    bar contains several entries, which are described in the following chapters. The icon bar

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    12/52

    contains icons for the most used functions.

    Title bar

    Menu bar

    Icon bar

    Page 18alphaSET, user manual, Version 2.05.00

    Page 18 of 111

    3 Introduction / brief description

    3.4.3.1 Icon catalogue

    The following list explains the available icons of the icon bar.

    Read file

    Save

    Print

    Read register

    Read service list

    Read load profile

    Read logfile

    Read meter configurationWrite Setting and parametrization

    parameter to the meter

    Set meter date/time

    Demand reset

    Page 19alphaSET, user manual, Version 2.05.00

    Page 19 of 111

    3 Introduction / brief description

    Reset meter error state

    Reset register

    Reset load profile and logbookSwitch to ripple receiver

    Read meter error

    Activate test mode

    Open communication protocol

    ...about alphaSet

    Page 20alphaSET, user manual, Version 2.05.00

    Page 20 of 111

    3 Introduction / brief description

    3.5 Indication of the software version

    To get information about the applied software version, select via Help the menu point "aboutalphaSET ... " or click on the following icon:

    This command opens a window with the data about the program alphaSET and its version.Image 3-5-1: Information screen

    Page 21alphaSET, user manual, Version 2.05.00

    Page 21 of 111

    4 User settings

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    13/52

    4 User settingsIn this chapter the options for the user settings are described. You find these settings via the

    menu point Extras.

    4.1 Communication

    Select via Extras the menu point Options, there the register card Communication.Image 4-1-1: Settings register card communication

    COM-Port

    With the function "Com-Port" the interfaces Com 1 to Com 16 of the PC can be selected. By

    the start ofalphaSET the program checks automatically the COM-Ports of the computer.

    It is the decision of the PC user himself whether the selected COM-Port is still free for the use

    by alphaSET.

    Initial Baud rate

    The initial baud rate of the communication between alphaSet and the connected meter can be

    adjusted by pull-down-menu. For more information to the baud rate shift see DIN EN 62056-

    21.

    Utility password

    A password for the meter communication can be assigned to the user profile that means an

    interrogation of the utility password is not executed any more (useful if the same EVU

    password for different meters is used).

    Read with 300 Baud only

    This option enables the constant reading of the meter with 300 baud. The automatic baud rate

    shift is disabled.

    Page 22alphaSET, user manual, Version 2.05.00

    Page 22 of 111

    4 User settings

    Suppression of optical reflexion

    With this option a lack of the suppression of optical reflexion of the probe according to hard-

    ware can be compensated by software.Attention: The probes from P+E delivered by ELSTER do not need this option,

    because the suppression of optical reflexion is already realized in the hardware.

    Create communication log file

    By selection of this option a communication protocol is created automatically, which is also

    written directly in a text file.

    Waiting time between baud rate switch [ms]

    In this box the waiting time con be assigned in milliseconds between the baud rate switching.

    Data format

    With this choice the physical transmission of the data between the meter and alphaSET can

    be defined. Default is 7,E,1. The format 8, N, 1 is only required for special meters.

    Note: If the data of the counter are read by the AMR system modem, only the settings

    of this modem is relevant and not the settings of the meter. OK

    The actual settings are taken over by clicking on this button. They are automatically written in

    the user-profile and are available on the next start ofalphaSET.

    Copy profile

    With the help of this button different settings can be saved in a new user-profile or releases

    can be transmitted out of other user profiles.

    Cancel

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    14/52

    Clicking on this button ignores all changes and you get back to the main program.

    Page 23alphaSET, user manual, Version 2.05.00

    Page 23 of 111

    4 User settings

    4.1.1 Remarks to the user-profile Railway

    If the user is logged in the user-profile Railway, the following menu appears, in which one

    can select additive the option railway meter.

    With the selection of this option, the initial baud rate for communication with the meter is set

    automatically to 4800 Baud. The train numbers which are stored in the meter are indicated in

    the load profile.Image 4-1-2: Settings at user profile "Railway

    Page 24alphaSET, user manual, Version 2.05.00

    Page 24 of 111

    4 User settings

    4.2 Modem

    Select via Extras the menu point Options, there the register card Modem.Image 4-2-1: Settings register card Modem

    Modem

    Here the user can set parameters on all modem functions ofalphaSET. These are

    necessary for the communication over a meter modem.

    Modem settings (Modem connected to the PC)

    Keep connection: the time can be registered, how long a connection should be

    maintained after the last communication from alphaSET between PC and connected

    modem. At the end of this timeout the connection is interrupted and the modem hangs

    up.

    Interface baud rate: In this drop down menu the baud rate between PC and (control

    point) modem can be adjusted. If its possible, select the highest one, which issupported by both.

    Initialization: Here is the necessary initialization string registered, which is required for

    the communication between PC and PC-Modem (see chapter 0

    ).

    Get line: If necessary, take here the settings to get a local loop (e.g. 0). Should a not

    numeric entry stand here, activate additionally the check box also not numeric.

    Telephone number: Here can the phone number be registered. If a telephone book is

    created, this entry automatically takes place after choice of the appropriate telephone

    book entry.

    Also not numeric: With this, it is possible to enter also not numeric chars (letters) as

    phone number.Page 25

    alphaSET, user manual, Version 2.05.00

    Page 25 of 111

    4 User settings

    4.2.1 Initialization strings

    Here are strings for the initialization of the modem connected to the PC:

    ATZ^MATD

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    15/52

    SAGEM mobilephone

    AT&FE0X3DT

    e.g. for ELSA modem and almost all other modems

    If you cant get a connection to your modem with this strings, it is recommended to use the

    users manual of your PC-Modem.

    4.3 FilesSelect via Extras the menu point Options, there the register card Files.

    In this menu the paths on the drives can be defined in which the different files should be

    stored. A click to the button enables the changing of the entries.

    In the pull down menu Proposal for file name(s) are several suggestions done for an

    automatic generation of the file name.Image 4-3-1: Settings register card files

    Page 26alphaSET, user manual, Version 2.05.00

    Page 26 of 111

    4 User settings

    4.4 Read register

    Select via Extras the menu point Options, there the register card Register.Image 4-4-1: Settings register card

    In this window the user can select whether the register data should be shown with or without

    clear text (designations according to identification number system OBIS).

    The reading of the serial number can be deactivated here, too.

    Note: In addition to the deactivation of the reading of the serial number it must be guaranteed

    that not meter serial number is selected as Proposal for file name(s) (see 4.3 Files).

    Release readout of eHz

    If the new eHz (electronic residential 3-phase meter) should be readout this checkbox has to

    be selected.

    Page 27alphaSET, user manual, Version 2.05.00

    Page 27 of 1115 Load profile

    5 Load profileSelect via Extras the menu point Options, there the register card Load profile.Image 5-0-1: Settings register card load profile

    Read load profile options

    Dont read load profile / log book header: If the user reads load profile or log book,

    the header is always read first by default, to find out start, end and channel number of

    the profile. In the case of a reading without header, the selected period is questioned

    directly without reviewing previously, which one is available. In this process, all

    available load profiles in the meter are read.

    Show load profile including calculated times: This function should be selectednormally. With this, all values in the load profile in alphaSET get time stamps. These

    are calculated of the alphaSET automatically based on the meter basic data and are

    not delivered by the meter itself (see VDEW-Lastenheft).

    Daily readout of load-profile: With this function the readout of load-profile over a

    longer period is devided into single days. In this way it is guaranteed, that only the

    defective days must be repeated at an occurring communication mistake. (This

    function is important in conjunction with transparent meter modems without securing of

    data, that do not support the R6 command (in accordance with VDEW-Lastenheft).

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    16/52

    Read load-profile/event-log file without password: With this option it can be defined

    whether the load profile reading takes place with or without password interrogation.

    Page 28alphaSET, user manual, Version 2.05.00

    Page 28 of 111

    5 Load profile

    5.1 General SettingsSelect via Extras the menu point Options, there the register card General.Image 5-1-1: Settings register card general

    alphaSET

    Edit passwords hidden: With activation the input of the password is not indicated any

    more in the clear text, only with ******** .

    Reset programming mode after parameterisation: After the change of parameters

    in a meter, the alphaSET puts the parameter mode of the counter automatically back.

    For more information about the parameter mode see chapter 8 Change of meter

    configuration.

    Check daylight saving set to EU standard: During the download of the tariff table to

    the meter an automatic check of the correct used EU daylight saving time will beexecuted and an error message is displayed if there's inconsistency.

    Page 29alphaSET, user manual, Version 2.05.00

    Page 29 of 111

    5 Load profile

    5.2 User languageSelect via Extras the menu point Options, there the register card Language.Image 5-2-1: Settings register card language

    Note:

    In order to activate all language changes, you should quit alphaSET and restart it after a

    language change.

    Page 30alphaSET, user manual, Version 2.05.00

    Page 30 of 111

    5 Load profile

    5.3 IEC 1107-AddressSelect via Extras the menu point IEC1107 address .Image 5-3-1: IEC 1107-Address

    An IEC1107-address can be registered here, which is send at every communication to the

    meter. The meter answers in this case only if the IEC1107-Address sent by alphaSET agrees

    with its configured address. The meter IEC address is used if more than one meter is

    connected to a modem by using the CL0 or RS485 interface.

    5.4 Change utility passwordSelect via Extras the menu point Change utility passwordImage 5-4-1: Utility password for communication

    The communication-password (from alphaSET to the meter) can be preset in this menu. That

    has no effect to the utility password in the meter.

    8 numeric chars are expected.

    Page 31alphaSET, user manual, Version 2.05.00

    Page 31 of 111

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    17/52

    6 Read meter data

    6 Read meter dataYou should first check the communication. The command read register is the simplest way to

    do it. If this doesnt work, please check the settings ofalphaSET, see chapter 4 User

    settings.

    6.1 Read register listSelect via Meter the menu point Read register or the following icon:Image 6-1-1 Read register

    By using this command the billing data list (register list or Std-dAtA on LCD) of a meter is read

    out.

    A window appears in which the reading data are visualized. If you have chosen the option

    read register with serial number (see chapter 4.4 Read register), the serial number will be

    indicated in the title bar.

    The identification number is indicated in the first column, the measured value in the second

    column and in the third column is an interpretation of the identification number in clear text to

    be seen, if the identification number corresponds to the OBIS identification system.

    Page 32alphaSET, user manual, Version 2.05.00

    Page 32 of 111

    6 Read meter data

    6.2 Read service listSelect via Meter the menu point Read service list or the following icon:Image 6-2-1: Read service list

    By using this command the settable service list (AbL-dAtA on LCD) of a meter is read out.

    A window appears in which the reading data are visualized.

    The identification number is indicated in the first column, the measured value in the second

    column and in the third column is an interpretation of the identification number in clear text to

    be seen, if the identification number corresponds to the OBIS identification system.

    For further information see chapter 8.14.1

    Page 33alphaSET, user manual, Version 2.05.00

    Page 33 of 111

    6 Read meter data

    6.3 Read settingsSelect via Meter the menu point Read settings or the following icon:Image 6-3-1: Read meter configuration

    This command enables the reading and displaying of the configuration of the meter. The input

    of a utility password is demanded for this operation.

    The following meter configurations are displayed:

    Type key

    Meter-Identification Pulse constants

    Demand measuring

    Load profile / log file

    Real time clock

    Tariff source

    Demand reset source

    Outputs

    Baud rate

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    18/52

    Page 34alphaSET, user manual, Version 2.05.00

    Page 34 of 111

    6 Read meter data

    Display control

    Display list

    Switch point clockBy clicking on close you get back to the main menu.

    The menu point modify appears in the menu bar after reading meter configuration.

    Note: You have the possibility to store the parameter set as text file, so that you can work with

    this parameter set in other programs (e.g. text progressing programs)

    The following check box serves for this:

    In this case, the name (and path) for the text file is asked after inquiry of the file name for the

    parameter set. The default pathname is registered in Extras/Options/Files in the field read

    meter configuration. The content of the indicated window will be stored.

    Page 35alphaSET, user manual, Version 2.05.00

    Page 35 of 1116 Read meter data

    6.4

    Read load profile

    Select via Meter the menu point Read load profile, or the following icon:Image 6-4-1: Read load profile

    The load profile of the meter can be read with this command. The configuration of the load

    profile is read and displayed after confirming.

    Certain settings for the specific reading of the load profile can be taken here:

    Selection of the measuring channels (as far as they exist in the meter).

    Limitation of the reading period. This period can be defined in the from or to input

    fields. By deactivating the checkboxes at start and end, the appropriate time stamps

    are indicated. These stamps can be edited by double clicking on them. Should acertain window be selected repeatedly, this can be stored and again be activated by

    the button "stored values". Frequently used specifications like last month, last week,

    yesterday or today can be selected directly.

    Partial readout (possibly from FW 3.02), that means use of the R6-command. For more

    information see VDEW-Lastenheft.

    Depiction of primary values in accordance of the transformer ratio for Voltage and

    Current. The transformer ratio is 1:1 if no primary values are activated.

    Note: The indicated meter data are then secondary data.

    Page 36alphaSET, user manual, Version 2.05.00

    Page 36 of 111

    6 Read meter dataAfter input of the reading period, the load profile of the meter is read by clicking on the button

    read load profile. If all data is read a new button Show load profile appears. With this

    command alphaSET shows all load profile data of the meter in a table.

    The following data are listed:

    Date

    Time

    Measured values of the channels (up to 8 channels)

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    19/52

    Status of the saved measuring periods.Image 6-4-2: Data of load profile

    The status-announcement is shortened, if several channels are parameterised, in

    accordance with:FE:

    Fatal fault

    CS:Backup time of real time clock exhausted

    MD:

    Measuring period disturbed (shorter measuring period)

    SC:

    Season change

    RS:

    Reset

    CC:

    Device clock

    PU:

    Power return

    PF:Power failure

    Page 37alphaSET, user manual, Version 2.05.00

    Page 37 of 111

    6 Read meter data

    Reading of large amounts of LP-data: Only 1000 entries can be displayed in one chart. To

    view advanced data, click previous values or following values.

    Comment to the user profile Railway: A train number is additionally indicated in the

    depiction of the load profile values in the user profile "Railway:

    Comment to read load profile without header: You have the possibility to read load

    profile, without reading previously information of the meter. For this and for more information

    concerning settings see chapter 5.

    6.4.1 Graphical display of load profile data

    With the selection show load profile you get the data of the meter in a table and additionally a

    button to show this information graphically.

    With this button you start the LP Analyzer tool and you get directly the following picture.Image 6-4-2: Graphical data of load profile

    Page 38alphaSET, user manual, Version 2.05.00

    Page 38 of 111

    6 Read meter data

    The following icons are available for the user:

    Back to the main window

    Print

    Change of scale of the y-axis

    Maximum x-axis

    Maximum y-axis

    Maximum x-axis and y-axis

    Additionally it is possible to zoom in. You just have to click in the graph and pull with the

    mouse, to mark of the area you want to see in more details.

    At the bottom the values of the load profile data is listed.

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    20/52

    Image 6-4-2: Table settings 1

    It is possible to show maximum of 8 channels. With the checkbox your are able to activate /

    deactivate the channels in the graph.

    If you double click on the field of the colour, you are able to choose different colours and types

    of designs.

    Page 39

    alphaSET, user manual, Version 2.05.00Page 39 of 111

    6 Read meter data

    To analyse in detail specific values of the load profile, you have to set the cursor to this line in

    the table of load profile date and then in the graph this position is displayed. Have a look at the

    next picture.Image 6-4-2: Table settings 2

    Page 40alphaSET, user manual, Version 2.05.00

    Page 40 of 111

    6 Read meter data

    6.5 Read power quality monitoringSelect via Meter the menu point Read power quality monitoring.Image 6-5-1: Read power quality monitoring

    The power quality profile of the meter can be read with this command.

    Structure and function mode are identically to chapter 6.4

    Read load profile .

    Page 41alphaSET, user manual, Version 2.05.00

    Page 41 of 111

    6 Read meter data

    6.5.1 Graphical display of power quality data

    With the selection Show power quality monitoring you get the data of the meter in a table andadditionally a button to show this information graphically.

    With this button you start the LP Analyzer tool and you get directly this following picture.Image 6-5-1: Graphical data of power quality monitoring

    Structure and function mode are identically to chapter 6.4.1 Graphical display of load profile

    data.

    Page 42alphaSET, user manual, Version 2.05.00

    Page 42 of 111

    6 Read meter data

    6.6 Read log fileSelect via Meter the menu point Read log file or the following icon:

    Image 6-6-1: Read logfileStructure and function mode are identically to chapter 6.4

    Read load profile.

    The representation of the logfile contains the date, the time and the event.

    According to the parametrization of the meter, one receives following entries:

    Power failure (3-phase or per phase)

    Power return (3-phase or per phase)

    Adjusting the time

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    21/52

    Functional error in the meter

    Demand reset

    Reset load profile and logbook

    Change energy/demand-tariff

    Backup time of real time clock exhausted

    Parameter change

    Season change terminal cover removal detection

    reverse run detection

    Page 43alphaSET, user manual, Version 2.05.00

    Page 43 of 111

    6 Read meter dataImage 6-6-2: Data from logfile

    6.7 Read log file 2Select via Meter the menu point Read log file 2.

    With FW 5.20 of the A1350 and FW 7.00 of the A220 a second log file can be activated in the

    meter. In that case the following last 30 events can be read with alphaSET:

    change of meter configuration

    register reset

    load profile reset

    instrumentation profile reset

    set time & date

    Page 44alphaSET, user manual, Version 2.05.00

    Page 44 of 111

    6 Read meter data

    6.8 Read meter error statusSelect via Test the menu point Read meter error or the following icon:

    Image 6-7: Read meter error status

    With the reading of the error status of the alpha meter, the possible error messages are listed.

    If a malfunction of the meter exists, this is indicated through a large red box in front of the error

    message. Little green boxes indicate on the other hand that no error exists.

    In this window the following two buttons can be used:

    Close

    The window closes and leads back to the main window

    Read meter error

    Reads the meter once again

    Page 45alphaSET, user manual, Version 2.05.00

    Page 45 of 111

    6 Read meter data

    6.9 Read communication protocolSelect via test the menu point Communication protocol or the following icon:

    If you choose this menu point, you can see the protocol of the last communication between

    alphaSET and the meter.Image 6-8-1: Read communication protocol

    It is also possible to view old communication protocols of alphaSET. You just have to click on

    the date and time row on the left hand side and you will get this protocol.

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    22/52

    Page 46alphaSET, user manual, Version 2.05.00

    Page 46 of 111

    7 Configuration of the meter

    7 Configuration of the meter7.1 Open of a parameter fileSelect via File the menu point Read parameter or the following icon:

    If you choose this menu point, you can open the following files directly:Image 7-1-1: File - Read parameter

    7.2 Save a parameter setSelect via File the menu point Save or the following icon:

    This command enables the saving of the reading data over a dialogue window.

    Parameter file:

    The file is saved by standard with the ending .par.

    Register content:

    The file is saved by standard with the ending .rg.

    Load profile content:

    The file is saved by standard with the ending .lp

    .

    Log file entries:

    The file is saved by standard with the ending .log

    .

    Switch programs:

    The file is saved by standard with the ending .uhr

    .

    Comment:

    You can only save, if you have previously read the corresponding data. (Screen display).

    Page 47alphaSET, user manual, Version 2.05.00

    Page 47 of 111

    7 Configuration of the meter

    7.3 Configuration of a meter by using a configuration fileSelect via File the menu point

    File with parameter -> meter

    .Image 7-3-1: File with parameter ->meter

    7.3.1 Switch point clock

    With this menu, the settings of the switch point clock can be loaded out of a switch program-

    file (ending: .uhr) and will be sent into the meter.The Utility password is required before the start of the communication.

    Note: The internal structure of the Switch point clock remained in the A1500 or A1350

    same as in the AEM500 meter. If the file, that is to be loaded to the meter, contains only one

    switch point clock, the obligatory check of the firmware version is cancelled. Therewith can

    even old switch point clock programs be loaded without problem to the new meter.

    It is to be respected generally on that, which the day types, the energy tariffs and the

    maximum tariffs of the meter also agree with the switch point clock program.

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    23/52

    7.3.2 Settings (without PW + ID)

    With this menu all setting parameters (parameters which can be changed without breaking the

    certification seal), except password and identification, can be loaded of a parameter file

    (ending: .par) and be sent to the meter. After input of the file name, a window, in which date

    Page 48

    alphaSET, user manual, Version 2.05.00Page 48 of 111

    7 Configuration of the meter

    7.3.3 Settings and parameterisations (without PW + ID)

    Icon in the icon bar:

    With this menu, all setting and parameter-parameters (except password and identification) can

    be loaded of a parameter file (ending: .par) and be sent to the meter. After input of the file

    name, a window, in which date and time are indicated, appears. After confirming with OK, the

    utility password is queried before the data are loaded into the meter.

    Comment:

    The parametrization-button must be pressed previously before the programming of the meter

    starts.

    7.3.3.1 Parameter-file WITHOUT calibration-data (without PW + ID)This menu point is a service function and to use only in consultation with ELSTER. Here are all

    parameters (class 0 to 6) of the meter (except password and identification) are written, only

    the calibration-data remain unchanged.

    This process is only possible with a special ELSTER password and requires no renewed

    calibration of the meter.

    7.3.3.2 Parameter-file WITH calibration-data (without PW + ID)

    This menu point is a service function and to use only in consultation with ELSTER. Here are all

    parameters of the meter (except password and identification) written, also the calibration-data

    are changed. This process is only possible with a special ELSTER password and requires a

    new calibration of the meter.

    7.4 Change of parametersWith the menu point Modify parameters of a meter or a file can be changed, saved, and

    loaded again into the meter.

    This menu point is first visible, if the configuration of the meter was read before (see chapter

    6.3 Read settings), or a file was loaded directly (see chapter 7.1 Open of a parameter file).

    The menu points in the upper section are setting parameters. The menu points in the lower

    section are parameterisation parameter and requiring an activation of the parameterisation

    button.

    After an alteration, you have to confirm the respective menu point with OK in order to send

    these new parameters to the meter. The following query appears:

    Page 49alphaSET, user manual, Version 2.05.00

    Page 49 of 1117 Configuration of the meterImage 7-4-1: Data transfer

    With a Yes the data are written directly into the meter. With a No this process is not

    executed, but that data are taken over into the database ofalphaSET.

    This is the general flow in the change of parameters. The exact description to the single

    parameters themselves follows in the following chapters.

    Page 50alphaSET, user manual, Version 2.05.00

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    24/52

    Page 50 of 111

    8 Change of meter configuration

    8 Change of meter configurationSelect the menu point Modify.Image 8-0: Menu point Modify

    This menu point is first visible if the configuration of the meter was read before (see chapter6.3 Read settings) or a parameter set was read by a file.

    The menu points in the upper section are setting parameters. The menu points in the lower

    section are parameterisation parameter and requiring an activation of the parameterisation

    button.

    Note: The menu entries of Modify are depending to the firmware version of the meter.

    Page 51alphaSET, user manual, Version 2.05.00

    Page 51 of 111

    8 Change of meter configuration

    8.1 IdentificationsSelect via Modify the menu point Identifications.Image 8-1-1: Identifications

    The following parameters can be modified in this window: Utility password 1

    Utility-identification #1

    Utility-identification #2

    Utility-identification #3

    Utility-identification #4

    Utility-identification #5

    Utility-identification #6

    IEC 1107-identification (=Answer of the meter on the request telegram)

    e.g. : read register

    S: 13:36:29,09 -- /?!

    E: 13:36:30,43 -- /ABB5\@V4.10

    S: 13:36:30,64 -- 050

    E: 13:36:31,17 -- 1-1:F.F(00000000)

    Page 52alphaSET, user manual, Version 2.05.00

    Page 52 of 111

    8 Change of meter configuration

    Note: \ and @ are firmly given indications, 14 further indications can be

    parametrized by the user.

    IEC 1107-address #1 (opt.)

    IEC 1107-address #2 (electr. 1)

    IEC 1107-address #3 (electr. 2)

    e.g. : read register

    S: 13:54:05,78 -- /?0000001234567890!

    E: 13:54:07,67 -- /ABB5\@1234567

    S: 13:54:07,87 -- 050

    E: 13:54:08,40 -- 1-1:F.F(00000000)

    After clicking the button OK the following security query appears Do you want to transfer the

    modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    25/52

    menu, the data are however saved in alphaSET. Cancel" causes the leaving of the window.

    Note: With the IEC1107 address the leading zeros or blanks are suppressed. They are sent to

    the meter by alphaSET, but the meter ignores them.

    Page 53alphaSET, user manual, Version 2.05.00

    Page 53 of 111

    8 Change of meter configuration

    8.2 Tariff sourceSelect via Modify the menu point Tariff source.Image 8-2-1: Tariff source up to FW 4.01

    Image 8-2-2: Tariff source from FW 4.10

    Starting with the firmware version 4.10 it is possible to set the tariff source independently for

    energy and demand. Three options are available here:

    External control inputs

    Internal ripple receiver

    Internal switch point clock

    By clicking on the button OK appears the security query Do you want to transfer the

    modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the

    menu. Cancel" causes the leaving of the window.

    Page 54alphaSET, user manual, Version 2.05.00

    Page 54 of 111

    8 Change of meter configuration

    8.3 Switch point clockSelect via Modify the menu point Switch point clock.

    The settings of the switch point clock in the meter can be indicated and changed here.

    8.3.1 Day type

    Select via Modify the menu point Switch point clock -> day type.Image 8-3-1: Menu Switch point clock

    The weekdays can be summarized to corresponding groups in the field day type. Theselection of the types takes place via the activation of the corresponding boxes. The fields with

    the designations day type 1/2/3/4 can be edited.

    An eight-place switch-program-number is assigned to each switch-program in the

    corresponding field, which can be modified. All chars, which can be displayed in the 7-

    segment-display of the meter ( 0..9,A,C,E,F,H,J,L,P,S,V,Y), are valid. In the field comment

    exists the possibility to enter free text. Though, this is not written in the meter, but only in the

    saved file.

    With the command save as file the switch-program can be saved. The command read from

    file loads an existing switch-program (file with the ending .uhr).

    The command print prints the complete switch-program including day-type- and season-

    definitions.

    Page 55alphaSET, user manual, Version 2.05.00

    Page 55 of 111

    8 Change of meter configuration

    By clicking on the button OK appears the security query Do you want to transfer the

    modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the

    menu.

    Cancel" causes the leaving of the window.

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    26/52

    8.3.2 Season change

    Select via Modify the menu point Switch point clock -> Season change.Image 8-3-2: Season change

    In the field seasons the number of the seasons can be defined as well as their start date (the

    field of the seasons name can be edited).

    1, 2 or 4 seasons can be arranged and distributed as desired over a total calendar year. They

    can even occur repeatedly in the total calendar year.Procedure: To register a season in the calendar, the field season 1 must be clicked (above

    green). Subsequently a black arrow marks the activation. Now clicking on the corresponding

    days must mark only the beginning and ending day of the season. With this menu structure,

    arises a higher flexibility, which permits for example to bind switch-programs of the season 1

    within the season 3 of the 9.-16. July.

    Page 56alphaSET, user manual, Version 2.05.00

    Page 56 of 111

    8 Change of meter configuration

    8.3.3 Tariff switch table

    Select via Modify the menu point Switch point clock -> Tariff switch table.Image 8-3-3: Switching timesIn this submenu are the actual settings of the different switching times taken. In the indicated

    table stands T for energy tariff, M1 until M4 for the different demand tariffs, R1 and R2

    for the two output relays (as far as these functions are parameterised like this).

    The different energy and demand tariffs can now be assigned individually to the switching

    times and their validity (defines over the season and the day type).

    The following buttons are available:

    Release locks: The check of alphaSET, whether T1-T4, M1-M4 and relay 1/2 are valid is

    unmade. Recommendation: Let this checkbox always deactivated.

    Accept: The changes concerning the selected switching time are transferred into the table.

    New: A new switching time is transferred into the table. The time of an available entry must

    be blocked first to be able to carry out this function.

    Delete: A designed entry is removed from the table.

    Comment: To each season and to each day type, a time entry is generated automatically at

    00:00 clock. The user has to indicate the corresponding energy and/or demand tariff.

    Page 57alphaSET, user manual, Version 2.05.00

    Page 57 of 111

    8 Change of meter configuration

    8.3.4 Holiday-list

    Select via Modify the menu point Switch point clock and there the register card Holiday-

    list.Image 8-3-4: Holiday-list

    All defined holidays are displayed in the table.With the pull-down-menu holiday list the selection of already recalculated holidays can be

    activated.

    The number of years, which should be calculated for each holiday, is indicated in the field

    "years". According to the number of the switching times and holidays, ca. 15 years can be

    saved in advance.

    With the check box cyclic one receives the possibility to define recurring holidays (e.g. 01.01.

    -> new year). If this option is not selected, one receives the possibility to indicate day, month

    and year of a fixed holiday (e.g. Easter Sunday).

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    27/52

    The following buttons are available:

    Accept: The changes concerning the selected holiday are transferred into the table.

    New:

    A new holiday is transferred into the table.

    Delete: A designed entry is removed from the table.

    Page 58alphaSET, user manual, Version 2.05.00Page 58 of 111

    8 Change of meter configuration

    8.3.5 Daylight saving time

    Select via Modify the menu point Switch point clock -> Daylight saving time.Image 8-3-5: Summer/winter time switch

    In this menu can the summer/winter time-switch either be deactivated, aligned at the EU

    standard or, in the setting "user defined", be defined in the indicated tables.

    Page 59alphaSET, user manual, Version 2.05.00

    Page 59 of 111

    8 Change of meter configuration8.4 Switch point clock (Update)Select via Modify the menu point Switch point clock (Update).

    A second switch point clock can be defined in the meter (with FW 5.10 of A1350 and FW 7.00

    of A220). At a predefined date the second tariff table will be activated and valid for the rest of

    the time. All data have to be defined in the same way as the first switch timetable.

    8.4.1 Day type

    Select via Modify the menu point Switch point clock (Update) -> day type.Image 8-4-1: Second tariff table

    Date of update

    The activation date (at 00:00) of the second tariff table has to be defined here.

    Page 60alphaSET, user manual, Version 2.05.00

    Page 60 of 111

    8 Change of meter configuration

    8.5 TimesSelect via Modify the menu point Times. Different possibilities to change the time base or

    communication timeout are offered:

    8.5.1 Source of Times

    Select via Modify the menu point Times -> Source of time.Image 8-5-1: Real time clock

    In this menu the user can define whether the network frequency or the quartz frequency is

    supposed to be used for the time of the internal real time clock of the meter.

    Notes: In general, the setting quartz is to be recommended because the quartz inserted are

    highly exact and temperature stable (< 5 ppm).

    Especially in use of a DCF-synchronization of the measuring period is it recommended to

    select the setting quartz. This is because the network frequency can vary and it can lead

    therefore to undesirable time set (in synchronization) with corresponding entries in the

    load profile.

    It is recommended to use line for meters that are not synchronized, because the

    temporal deviations are countervailed with the time. Therewith, the time doesnt run

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    28/52

    away.

    Whether these parameters are set parameters or parameterisation parameters depends

    on the firmware version of the meter which works at the moment with the alphaSET: Until

    including FW version 3.05 these are parameterisation parameters, from FW version 4.00

    these are set parameters.

    Page 61alphaSET, user manual, Version 2.05.00

    Page 61 of 111

    8 Change of meter configuration

    By clicking on the button OK appears the security query Do you want to transfer the

    modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the

    menu.

    Cancel" causes the leaving of the window.

    8.5.2 Display Timeouts

    Select via Modify the menu point Times -> Display Times.Image 8-5-2: Display timeouts

    In this menu the user can define the display scroll time and the timeout for the alternate mode.

    After the alternate time out exceeds the limit, the meter goes back automatically in the scroll

    mode.

    Page 62alphaSET, user manual, Version 2.05.00

    Page 62 of 111

    8 Change of meter configuration

    8.5.3 Communication Timeouts

    Select via Modify the menu point Times -> Communication Times.Image 8-5-3: GPRS communication timeout

    Notes:

    According the IEC1107 standard the maximum communication timeout between 2

    characters is 1,5s.

    For GPRS application the maximum timeout between 2 characters has to be increased.

    The suggestion is to use in that case a timeout of 6s.

    Page 63alphaSET, user manual, Version 2.05.00

    Page 63 of 111

    8 Change of meter configuration

    8.6 Demand resetSelect via Modify the menu point demand reset.Image 8-6-1: Demand reset

    In this menu, the possible sources for the triggering of a maximum demand reset can be

    released or blocked. Settings, which are not selectable, have a grey background. The day

    within a month, at which the maxima demand reset should take place, can be defined with the

    button every month on the... at 0.00 PM. Moreover the duration of the reset lock time can beadjusted. The reset lock time is only active by activation over the same reset lock source.

    By clicking on the button OK appears the security query Do you want to transfer the

    modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the

    menu. Cancel" causes the leaving of the window.

    Page 64alphaSET, user manual, Version 2.05.00

    Page 64 of 111

    8 Change of meter configuration

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    29/52

    8.7 Overload thresholdSelect via Modify the menu point Overload threshold.Image 8-7-1: Overload threshold

    The user has the possibility to configure one or two outputs of the meter, so that by exceeding

    of a specific demand threshold an output contact is opened and/or closed. The overload

    threshold 1 refers always to the measuring channel 1 of the meter. The overload 2 can be set

    on every defined measuring channel of the meter. At the start of a demand period, the outputcontact is either opened or closed (if it is parameterised). By exceeding the threshold the

    output contact is closed (opened).

    Starting with the FW version 4.40 it is additionally possible to enter a threshold value for the

    tan(phi).

    Note: The format of the overload threshold is the same as for the demand values. Up to FW

    version 4.00 only one overload threshold can be parameterised, since then two. Only since

    firmware 4.20 is it possible to configure overload threshold 2 freely.

    Page 65alphaSET, user manual, Version 2.05.00

    Page 65 of 111

    8 Change of meter configuration

    8.8 Baud rateSelect via Modify the menu point Baud rateImage 8-8-1: Baud rate

    In this menu the start baud rate or either the maximum baud rate of the meter can be selected,

    separated between optical or electrical interface.

    Further baud rates can be selected by a click on the pull-down-arrows.

    With the FW version 4.40 of the A1500 a second electrical interface is available. For this case

    it is possible to set the priorities of this interfaces.

    Note: If the start baud rate of an interface in the meter is changed, the baud rate for the

    communication must be changed after writing into the meter, too. (See chapter 4.1

    Communication).

    Page 66alphaSET, user manual, Version 2.05.00

    Page 66 of 111

    8 Change of meter configuration

    8.9 SynchronizationSelect via Modify the menu point Synchronization.Image 8-9-1: Synchronization

    In this menu the mode of the demand period synchronisation as well as the synchronisation of

    the meter clock can be defined by using an integrated ripple receiver, an internal DCF77-clock

    or an external control input.

    The image offers the following adjustment possibilities:

    None

    To next interval: recommended if a control input (MPE Kl. 16) to the measuring periodsynchronization is used by an external synchronization pulse.

    To next minute: recommended with reservation if an externally produced DCF pulse is

    used by an external control input for the synchronization of the measuring period.

    With interval to reference-time: recommended in synchronization over ripple receiver. In

    selecting the point With interval to reference-time appears a menu, in which the reference

    time and the time window of the synchronization can be adjusted.

    Page 67

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    30/52

    alphaSET, user manual, Version 2.05.00

    Page 67 of 111

    8 Change of meter configuration

    Set date/time by DCF 77-antenna input: recommended by using the pulse input 1 as a

    DCF77 antenna input. (A DCF77antenna must be connected to the pulse input 1). By

    activation of this feature the internal meter clock will by synchronized every 5 minutes after

    a full hour, after power up or by activation of the meter test mode.Note: After activation of the DCF 77 antenna input the meter will generate a warning

    FF2 1000000 until a correct time/date information is decoded. A DCF77 decoding can be

    activated by a formatted command too.

    By clicking on the button OK appears the security query Do you want to transfer the

    modified data to the meter?. "Yes" writes the changes into the meter, "no" breaks off the

    menu.

    Cancel" causes the leaving of the window.

    Note: DCF 77 decoding is available from meter with firmware version 4.00.

    Page 68alphaSET, user manual, Version 2.05.00

    Page 68 of 111

    8 Change of meter configuration

    8.10 Backup time of the real time clockSelect via Modify the menu point Backup time of real time clock.Image 8-10-1: Backup time of real time clock

    In order to be able to build a battery into the meter subsequently, there is the possibility to

    change the default settings from supercap to battery.

    Note: This is first possible from FW version 4.00 of the meter. The rating plate of the meter

    must be removed to install the Battery.

    8.11 Inverting Inputs/OutputsSelect via Modify the menu point Inverting Inputs/Outputs .Image 8-10-1: Backup time of real time clock

    With this menu it is possible to invert inputs and outputs by activating the checkboxes. This ispossible with firmware version 4.30 and higher.

    Page 69alphaSET, user manual, Version 2.05.00

    Page 69 of 111

    8 Change of meter configuration

    8.12 Power qualitySelect via Modify the menu point power quality.

    8.12.1 Release of power quality functionalityImage 8-11-1: Release power quality values

    In this menu you have the possibility to release the measurement of the power quality values,

    which can then be read over the service list or which or are available for the power quality

    profile.

    Page 70alphaSET, user manual, Version 2.05.00

    Page 70 of 111

    8 Change of meter configuration

    8.12.2 Load profile of power quality data

    In this menu the settings of the power quality monitoring can be configured.Image 8-11-2: Power quality monitoring data

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    31/52

    The following parameters can be assigned:

    Assignment of load profile channel number and quantity

    Storage type of every channel

    Average value over the period of the power quality data

    Minimum value inside the period of the power quality data

    Maximum value inside the period of the power quality data

    Duration of the load profile period (1..60min)Notes:

    The max. Duration of the load profile of the power quality data depends on the duration of

    the billing data load profile and cannot be changed in this menu. This duration depends on

    the measure period and the number of channels.

    The OBIS identifier for the load profile channels will be assigned automatically.

    The different power quality measurements have to be activated in the menu Release

    power quality values, to be used here.

    Page 71alphaSET, user manual, Version 2.05.00

    Page 71 of 111

    8 Change of meter configuration

    8.12.3 Power Quality Monitoring

    In this menu the settings of the power quality monitoring can be configured.Image 8-11-3: Power quality monitoring

    The following parameters can be assigned:

    Assignment of power quality data to a register

    Definition of a upper and / or lower limit

    Measuring interval (1..60min)

    The FW 5.10 and FW 4.40 offer additional features to observe the network regarding power

    quality issues. Therefore up to 18 different counters with up to 18 thresholds can be activated

    to detect the occurrence, if a power quality value is above or below a predefined threshold

    during a user programmable period (1, 2, 3, 4, 5, 6, 10,12, 15,20, 30, 60 minutes).

    Furthermore 2 log file events and 2 relay contacts can be activated if 1 or more events will be

    above or below the predefined threshold.Additionally with the logic OR / AND operation you are able to combine the different

    information of the thresholds.

    Page 72alphaSET, user manual, Version 2.05.00

    Page 72 of 111

    8 Change of meter configuration

    8.13 Copper-/Iron-lossesIn this menu the definitions for the transformer and line loss calculation can be configured.

    This feature is only supported with the FW 4.30 of the A1500 and A2500.Image 8-12-1: Transformer and line losses

    The following parameters can be assigned:

    Constant R of the transformer loss calculation

    Constant X of the line loss calculation

    Decimals for the transformer loss register

    Decimals for the line loss register

    To display the transformer and line loss register on the LCD or optical/electrical interface the

    value has to be assigned to the display list.

    For the right function you have to select your nominal voltage and current of your meter. The

    internal algorithm needs this information to calculate with the decimals the overflow boundary.

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    32/52

    Page 73alphaSET, user manual, Version 2.05.00

    Page 73 of 111

    8 Change of meter configuration

    8.14 Display

    The parameter settings of the display are divided in two menu points. Service list

    Dispay parameter

    Note: With the FW version 4.20 a second settable display list (service list) was added to the

    meter.

    8.14.1 Service list

    Select via Modify the menu point Service list.Image 8-13-1: Service list

    This service list is additional to the alternate list. In the display of the meter you will find it via

    the symbol Abl-data. Basically the list is blocked, but can be released since firmware version

    4.10 of the meter by selecting the checkbox "The service-list IS released.

    The handling of this service list is identical with chapter 8.14.2.1 Display list with the

    exception that there is no display of data in the scroll mode.Page 74

    alphaSET, user manual, Version 2.05.00

    Page 74 of 111

    8 Change of meter configuration

    Explanation:

    No.:

    Consecutive number (automatically set).

    Me:

    medium of the displayed value

    Ch

    channel number of the displayed value

    ID-Code:

    ODIS-ID (firmly assigned after standard)

    wU:

    Display with Unit (freely selectable)

    AM:

    Display in alternate mode (freely selectable)

    wP:

    Display with historical billing data (freely selectable)

    SP:

    Display (with historical values) in the display sequence (scroll-historical-

    Values) (freely selectable)

    D1:Display date/time in one line (firmly assigned through parameter set)

    op:

    Output over optical interface (freely selectable)

    el:

    Output over electrical interface (freely selectable)

    Description: Explanation to the display value

    The following buttons are required for changing the display table:

    Creating a new entry in the display table.

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    33/52

    Copying of the marked area of the display table (also

    new entries can be generated on this basis)

    Takes the changes over into the indicated display table

    Automatic sorting of the table

    Deletes the marked display entry

    Page 75alphaSET, user manual, Version 2.05.00

    Page 75 of 111

    8 Change of meter configuration

    8.14.2 Display parameter

    8.14.2.1 Display list

    Select via Modify the menu point Display parameter -> Display list.Image 8-13-4: Display list

    The register values with the associated IDs can be selected here. It is possible to chose scroll-

    mode (SM), alternate mode (AM), the optical (OP) and/or electric interface (EL).

    The handling of this service list is identical with chapter 8.14.1 Service list with one addition:

    SM:

    Display in scroll-mode (freely selectable)

    Page 76alphaSET, user manual, Version 2.05.00

    Page 76 of 111

    8 Change of meter configuration

    8.14.2.2 General settings of the display

    Select via Modify the menu point Display parameter and there the register card Control.Image 8-13-6: Settings of the display

    In this menu you are able to set the following parameters:

    total number / number of digits / unit for the energy register data

    total number / number of digits / unit for the demand register data

    total number / number of digits / unit for the cumulative register data

    using medium&channel for OBIS identifier

    reading data with/without units

    time&date format

    Page 77alphaSET, user manual, Version 2.05.00

    Page 77 of 111

    8 Change of meter configuration

    8.14.2.3 Configuration of historical values

    Select via Modify the menu point Display parameter and there the register card Hist.

    Values.Image 8-13-7: Configuration of historical values

    In this menu can the maximum number of historical values and the number of values for the

    different medium (optical/electrical interface or alternate list) be defined.

    Page 78alphaSET, user manual, Version 2.05.00

    Page 78 of 111

    8 Change of meter configuration

    8.15 Pulse constantsSelect via Modify the menu point Pulse constants.Image 8-14-1: Transformer ratio

    The user is able to select the measurement type: secondary or primary measurement. By

  • 7/30/2019 Download ELSTER Energy Meter-Kar Key

    34/52

    using the primary measurement the current and voltage transformer ratio is included in the

    energy and demand measurement results of the meter.

    Furthermore it is possible to define the pulse constant of the LED and the relay output of the

    meter.

    Additionally the pulse duration of the pulse output can be defined in multiple of 8ms.

    Page 79alphaSET, user manual, Version 2.05.00

    Page 79 of 111

    8 Change of meter configuration

    8.16 Pulse inputsSelect via Modify the menu point pulse inputsImage 8-15-1: Pulse inputs

    The user has, by standard, 1 pulse input at disposal (with disuse of the DCF-input). 2 further

    pulse inputs can be used if an optional conductor board is used in the meter. The inputs

    accord to the SO-standard. An own pulse constant can be assigned to the pulses of the pulse

    inputs. The summation of the input pulses is stored in a separate register and is included in

    the standard reading list of the meter.

    The following functions are available:

    Measuring period synchronization input, which must be controlled by a relay (Attention!

    No connection to 230V possible).

    Check of opening terminal cover (optional): A removing of the terminal cover can be

    detected with this input. A reed relay is positioned at the terminal cover, which bypasses

    the input. If the cover is removed, an entry in the log file occurs and the corresponding

    meter is incremented. A warning appears in the display, which can only be removed by

    using the interface.

    F.F.1: 00010000

    Pulse input: pulse constants and number of decimals are freely selectable.

    Summation input for measuring block 3: The pulse input could be added to the register of

    measuring block 3. The pulse constant is freely selectable; measuring block 3 specifies the

    number of decimals.

    Note: Pulse input 1 can also be used as DCF-input and is then deactivated at this place.

    Page 80alphaSET, user manual, Version 2.05.00

    Page 80 of 111

    8 Change of meter configuration

    8.17 Load profile / logfile - parameter

    8.17.1 Load profile parameter

    Select via Modify the menu point Load profile / log-book parameter.

    In the first register card the measuring quantities can be assigned to the load profile channels.

    A plausibility check of the parameters takes place before the image appears:

    Are all necessary parameters for the parametrization loaded into the alphaSET?

    Is the load profile generally released?

    Is the load profile released in the type key?

    Is a VDEW-load profile parametrized?

    The form is not indicated and an error message appears instead, if one of these tests leads to

    a negative result.Image 8-16-1: Load profile parameter

    The final layout of the wi