dosimeter-radiometer mks-05 terra -...
TRANSCRIPT
TERRA Dosimeter-radiometer MKS-05
Purpose of UsePurpose of Use
Measurement of gamma and X-ray radiation ambient dose equivalent rate (DER). Measurement of gamma and X-ray radiation ambient dose equivalent (DE). Measurement of surface beta-particles flux density. Measurement of dose equivalent accumulation time. Real time measurement (clock).
To obtain additional information on radiation measurement instrumentsplease contact our international sales managers at [email protected] Head of International Sales Department - Nataly Kuz’ at [email protected]
How to find us
Naukova Str.
Tro
lleyb
usn
a S
tr.
Str
yysk
a S
tr.
Volodymyr Velyky Str.
Knya
hyn
i Olh
y S
tr.
"Lviv"Department
Store
McDonald's
Church
Bus
Fact
ory
PE “SPPE “Sparing-Vist Center”
City
Cente
r
Bus
Sta
tion
City
Cente
r
Airport,Railway station Naukova Str.
Airport,Railway station
Rubchaka Str.
- stop
33 Volodymyr Velyk Str. Lviv, 79026Tel. +380322421515Fax +380322422015
e-mail: [email protected] www.ecotest.ua
y , Ukraine
Private Enterprise “Scientific & Production Private Enterprise “Sparing-Vist Center”
PE “SPPE “Sparing-Vist Center”
TERRADosimeter-radiometer MKS-05
Radiation Measurement InstrumentsRadiation Measurement Instruments
BASIC
mod
el
Branches of UseBranches of Use
Customs and Border ServiceLaw enforcement agencies (Army, Ministry of Affairs,State Security Services, guard services) Ministry of Emergencies, Civil DefenseVehicles monitoring, seaports and airportsEnvironmental inspectoratesSanitary and epidemiological servicesRadiologic laboratoriesLabor protection MedicineEducational programs
Internal
Radiation Measurement InstrumentsRadiation Measurement Instruments
TERRA Dosimeter-radiometer MKS-05
SpecificationsSpecifications
Gamma and X-ray radiation dose 137equivalent rate ( Cs)
Gamma and X-ray radiation dose 137equivalent ( Cs)
-
-
Measurement ranges and basic relative errors:
µSv/h
mSv
%
21/(сm ·min)
0.1…9 999;
0.001…9 999; ±15%
±(15+2/Н*(10)),where Н*(10) is µSv/h
10…100 000;
..
±(20+200/φ ),β2φwhere is1/(cm ·min)β%
Dose equivalent accumulation time and accuracy of measurement
- 1min…100h;±0.1s per 24h
Beta radiation- MeV 0.5…3.0
Energy ranges of measurement and energy dependence:
Gamma and X-ray radiation- MeV 0.05…3.0; ±25%
Resolution of threshold level programming for:
dose rate µSv/h 0.01
-
-
dose
- flux density
mSv
10 /(cm ·min)3 2
0.001
0.01
Measurement time intervals
Battery life*
Weight
Dimensions
Operating temperature range °С -20…+50
seconds
hours
kg
mm
1 ... 70
2 000
0.15
120x52x26
Delivery KitDelivery Kit
MKS-05 "TERRA" dosimeter-radiometer; operating manual; cardboard box; leather case.
FeaturesFeatures
Five independent measuring channels with alternate indication of data on the single liquid crystal display. Built-in gamma, beta sensitive Geiger-Muller counter. Prompt evaluation of gamma background within 10 seconds. Automatic subtraction of gamma background at measurement of beta contamination. Measurement results averaging, manually and automatically interrupted. Automatic setting of measurement intervals and ranges. Audio signalling of each detected gamma-quantum and beta-particle with possible switching off. Two-tone audio alarm of exceeded programmed threshold levels. Digital display backlight. Two AAA size batteries. Low battery indication. Shock resistant frame. Small weight and dimension parameters.
TERRADosimeter-radiometer MKS-05
* under gamma background not more than 0.3 µSv/h, switched off display backlight and alarm system
90Beta-particles flux density ( Sr+ Y)90-