dop-b07s411/dop-b07s411k delta hmi

2
DOP-B07S411K (Front View) DOP-B07S411 / DOP-B07S411K 196.9 +0.04"+1.0 0(7.75" -0 ) +1.0(5.63"+0.04" ) -0 0 (1) Preface Thank you for purchasing DELTA’s DOP-B series. This instruction sheet will be helpful in the installation, wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure correct use. You should thoroughly understand all safety precautions before proceeding with the installation, wiring and operation. Place this instruction sheet in a safe location for future reference. Please observe the following precautions: Install the product in a clean and dry location free from corrosive and inflammable gases or liquids. Ensure that all wiring instructions and recommendations are followed. Ensure that HMI is correctly connected to a ground. The grounding method must comply with the electrical standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.). Do not disassemble HMI, modify or remove wiring when power is applied to HMI. Do not touch the power supply during operation. Otherwise, it may cause electric shock. If you have any questions during operation, please contact our local distributors or Delta sales representatives. The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/ A B User-defined Function Keys / System Keys A User-defined Function Keys: F1, F2, F3, F4 System Keys: , , , SYS : Power LED Indicator Lights in green when HMI works normally. : Operation LED Indicator (Blue) (Note1) C (5) Specifications MODEL LCD MODULE Display Type 1 USB Slave Ver 2.0 1 USB Host Ver 1.1 RS-232(supports hardware flow control) RS-232 / RS-485 RS-422 / RS-485 N/A Built-in Natural air circulation CE IP65 DC +24V-10% ~ +15%(please use isolated power supply) AC500V for 1 minute (between charging (DC24V terminal) and FG terminals) 4.0W 3V lithium battery CR2032 × 1 It depends on the temperature used and the conditions of usage, o about 3 years or more at 25 C. 0 C ~ 50 C -20 C ~ +60 C 10% ~ 90% RH [0 ~ 40 C], 10% ~ 55% RH [41 ~ 50 C] Pollution Degree 2 IEC 61131-2 Compliant 5Hzf9Hz = Continuous: 1.75mm / Occasional: 3.5mm 9Hzf150Hz = Continuous: 0.5g / Occasional: 1.0g X, Y, Z directions for 10 times 215 x 161 x 50 196.9 x 142.9 Approx. 820g Approx. 840g o o Resolution Backlight Display Size Operation System MCU NOR Flash ROM SDRAM Backup Memory Buzzer USB COM1 DOP-B07S411 DOP-B07S411K 7" TFT LCD (65535 colors) 800 x 480 pixels LED Back Light (less than 20,000 hours half-life at 25 C) (Note 1) 154.08 x 85.92mm Delta Real Time OS 32-bit RISC Micro-controller Flash ROM 128 MB (OS System: 30MB / Backup: 16MB / User Application: 82MB) 64Mbytes 32Kbytes Multi-Tone Frequency2K ~ 4K Hz)/85dB Storage Temperature Ambient Humidity Power Input Terminal COM2 USB Host B D F COM1 USB Slave Battery Case / System Key Vibration Resistance Dimensions (W) x (H) x (D) mm Panel Cutout (W) x (H) mm Weight (4) Dimensions A B NOTE 1) The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving o current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25 C normal temperature and humidity conditions. 2) The value of the power consumption indicates the electrical power consumed by HMI only without connecting to any peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply which the capacity is 1.5 ~2 times the value of the power consumption. 3) The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/ A Touch Screen / Display B Power LED Indicator o o o o o 142.3 (5.6") 161(6.34") B07S411/B07S411K Instrunction Sheet 142.9 DOP-B07 High ColorWide ScreenUser-Friendly HMI Products D Note: T=1.6mm(0.063")~6mm(0.24") 51.2(2.02") T 215(8.46") 154.1 x 87.6mm B (2) Pin Definition of Serial Communication DOP-B07S411 / DOP-B07S411K COM1 Port COM Port PIN 1 2 3 4 5 6 7 8 9 MODE1 RS-232 C The operation LED indicator blinks in blue when either the communication is carried out or the data is accessing (please refer to the “Note1” below for explanation). : Alarm LED Indicator (Red) The alarm LED indicator blinks in red when one of the alarms is on. D Touch Screen / Display Serial COM Port PIN1 RXD TXD GND RTS CTS COM2 COM3 NOTE Function Key 1. The definition of the operation LED indicator (Blue) can be determined by the users freely. User defined key x 4 + System key x 4 DOP-B07S411 / DOP-B07S411K COM2 Port MODE1 COM Port PIN Perpetual Calendar (RTC) MODE2 COM2 COM3 MODE3 COM2 COM3 DOP-B07S411 / DOP-B07S411K (Rear View) Cooling Method Safety Approval COM2 RS-232 COM3 RS-485 RS-485 RS-485 RS-232 RS-422 D+ TXD+ RXD TXD D+ D+ GND D- RXD+ GND TXD- C D- D- RXD- D B F PIN1 1 2 3 4 5 6 7 8 9 Waterproof Degree Operation Voltage (Note2) Voltage Endurance Power Consumption (Note 2) RXD TXD GND E Backup Battery Backup Battery Life Operation Temperature Note1: Blank = No Connection. (3) Parts Names DOP-B07S411 (Front View) A C E A

Upload: davidlee

Post on 19-Dec-2015

42 views

Category:

Documents


13 download

DESCRIPTION

Delta DOP series Human Machine Interface provides various touch screens with multiple dimensions and colors and it also offers fast and convenient control functions for industrial automation machines.

TRANSCRIPT

Page 1: DOP-B07S411/DOP-B07S411K Delta HMI

DOP-B07S411K (Front View) DOP-B07S411 / DOP-B07S411K

196.9+0.04"+1.0

0 (7.75" -0 )

+1.0 (5.63"+0.04" )-0

0

(1) PrefaceThank you for purchasing DELTA’s DOP-B series. This instruction sheet will be helpful in the installation,wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensurecorrect use. You should thoroughly understand all safety precautions before proceeding with theinstallation, wiring and operation. Place this instruction sheet in a safe location for future reference. Pleaseobserve the following precautions:

Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.Ensure that all wiring instructions and recommendations are followed.Ensure that HMI is correctly connected to a ground. The grounding method must comply with the

electrical standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.).Do not disassemble HMI, modify or remove wiring when power is applied to HMI.Do not touch the power supply during operation. Otherwise, it may cause electric shock.

If you have any questions during operation, please contact our local distributors or Delta salesrepresentatives.The content of this instruction sheet may be revised without prior notice. Please consult our distributors ordownload the most updated version at http://www.delta.com.tw/

A

B

User-defined Function Keys / System Keys

A User-defined Function Keys: F1, F2, F3, F4

System Keys: , , , SYS

: Power LED Indicator

Lights in green when HMI works normally.

: Operation LED Indicator (Blue) (Note1)

C (5) SpecificationsMODEL

LCD MODULE Display Type

1 USB Slave Ver 2.01 USB Host Ver 1.1

RS-232(supports hardware flow control)

RS-232 / RS-485

RS-422 / RS-485

N/A

Built-in

Natural air circulation

CE

IP65

DC +24V(-10% ~ +15%)(please use isolated power supply)

AC500V for 1 minute (between charging (DC24V terminal)and FG terminals)

4.0W

3V lithium battery CR2032 × 1

It depends on the temperature used and the conditions of usage,o

about 3 years or more at 25 C.0 C ~ 50 C

-20 C ~ +60 C

10% ~ 90% RH [0 ~ 40 C], 10% ~ 55% RH [41 ~ 50 C]Pollution Degree 2

IEC 61131-2 Compliant5Hz≦f<9Hz = Continuous: 1.75mm / Occasional: 3.5mm9Hz≦f≦150Hz = Continuous: 0.5g / Occasional: 1.0g

X, Y, Z directions for 10 times

215 x 161 x 50

196.9 x 142.9

Approx. 820g Approx. 840g

o o

Resolution

Backlight

Display Size

Operation System

MCU

NOR Flash ROM

SDRAM

Backup Memory

Buzzer

USB

COM1

DOP-B07S411 DOP-B07S411K

7" TFT LCD (65535 colors)

800 x 480 pixels

LED Back Light (less than 20,000 hours half-life at 25 C) (Note 1)

154.08 x 85.92mm

Delta Real Time OS

32-bit RISC Micro-controller

Flash ROM 128 MB(OS System: 30MB / Backup: 16MB / User Application: 82MB)

64Mbytes

32Kbytes

Multi-Tone Frequency(2K ~ 4K Hz)/85dB

Storage Temperature

Ambient Humidity

Power Input Terminal

COM2

USB Host

B

D

F

COM1

USB Slave

Battery Case / System Key

Vibration Resistance

Dimensions(W) x (H) x (D) mmPanel Cutout(W) x (H) mm

Weight(4) Dimensions

A BNOTE

1) The half-life of backlight is defined as original luminance being reduced by 50% when the maximum drivingo

current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25 C normaltemperature and humidity conditions.

2) The value of the power consumption indicates the electrical power consumed by HMI only without connectingto any peripheral devices. In order to ensure the normal operation, it is recommended to use a power supplywhich the capacity is 1.5 ~2 times the value of the power consumption.

3) The content of this instruction sheet may be revised without prior notice. Please consult our distributors ordownload the most updated version at http://www.delta.com.tw/

A Touch Screen / Display B Power LED Indicator

o o

o o

o

142.3 (5.6")161(6.34")B07S411/B07S411K Instrunction Sheet

142.9

DOP-B07 High Color‧Wide Screen‧User-Friendly HMI Products

D

Note:T=1.6mm(0.063")~6mm(0.24")51.2(2.02")

T215(8.46")

154.1 x 87.6mm

B

(2) Pin Definition of Serial CommunicationDOP-B07S411 / DOP-B07S411K COM1 Port

COM Port PIN

123456789

MODE1

RS-232

C

The operation LED indicator blinks in blue when either the communication is carried

out or the data is accessing (please refer to the “Note1” below for explanation).

: Alarm LED Indicator (Red)

The alarm LED indicator blinks in red when one of the alarms is on.

D Touch Screen / Display SerialCOM Port

PIN1 RXDTXD

GND

RTSCTS

COM2

COM3NOTE

Function Key1. The definition of the operation LED indicator (Blue) can be determined by the users freely.

User defined key x 4 +

System key x 4DOP-B07S411 / DOP-B07S411K COM2 Port

MODE1

COM Port PIN

Perpetual Calendar (RTC)MODE2

COM2 COM3

MODE3

COM2 COM3DOP-B07S411 / DOP-B07S411K (Rear View) Cooling Method

Safety ApprovalCOM2

RS-232

COM3

RS-485 RS-485 RS-485 RS-232 RS-422

D+ TXD+RXDTXD

D+ D+GND

D-

RXD+GND

TXD-

CD- D- RXD-

D

B

F

PIN1

123456789

Waterproof Degree

Operation Voltage (Note2)

Voltage Endurance

Power Consumption (Note 2)

RXDTXD

GND

EBackup Battery

Backup Battery Life

Operation TemperatureNote1: Blank = No Connection.

(3) Parts Names

DOP-B07S411 (Front View)

A

C

E

A

Page 2: DOP-B07S411/DOP-B07S411K Delta HMI

Aydınlatma

Display Ölçü

İşletim Sistemi

MCU

NOR Flash ROM

SDRAM

Backup Memory

Buzzer

USB

SeriCOMPort

COM1

COM2

COM3

Fonksiyon Tuşu

o

DOP-B07S411 DOP-B07S411K

7" TFT LCD (65535 renk)

800 x 480 piksel

LED Aydınlatma (25 C yarım ömürde 20,000 saatden az)

154.08 x 85.92mm

Delta Real Time OS

32-bit RISC Micro-işlemci

142.3 (5.6")161(6.34")B07S411/B07S411K Bilgi Dökümanı

142.9

DOP-B07 Yüksek Renk‧Geniş Ekran‧Kullanımı Kolay HMI Ürünleri

D

Note:T=1.6mm(0.063")~6mm(0.24")51.2(2.02")

T215(8.46")

(Not 1)

154.1 x 87.6mm

B

(2) Seri Haberleşme Pin AçıklamalarıDOP-B07S411 / DOP-B07S411K COM1 Port

COM Port

PIN1

PIN

C

Flash ROM 128 MB(OS Sistem: 30MB / Backup: 16MB / Kullanıcı Uygulama: 82MB)

64Mbyte

32Kbyte

Multi-Ton Frekans(2K ~ 4K Hz)/85dB

1 USB Slave Ver 2.01 USB Host Ver 1.1

RS-232(donanım flow (akış) kontrol destekler)

RS-232/RS-485

RS-422/RS-485

N/A

Dahili

Doğal hava sirkulasyonu

CE

IP65

DC +24V(-10% ~ +15%)(lütfen izoleli güç kaynağı kullanınız)

1 dakika için AC500V (DC24V besleme terminalleri ve FG terminalleri arasında)

4.0W

3V lityum pil CR2032 × 1

Kullanım koşulları ve ortam sıcaklığına bağlı olarak 25 C’de yaklaşık 3 yıl veyaüzeri.

0 C ~ 50 C

-20 C ~ +60 C

10% ~ 90% RH [0 ~ 40 C], 10% ~ 55% RH [41 ~ 50 C]Kirlenme Derecesi 2IEC 61131-2 Uyumlu

5Hz≦f<9Hz = Sürekli: 1.75mm / Geçici: 3.5mm9Hz≦f≦150Hz = Sürekli: 0.5g / Geçici: 1.0g

X, Y, Z yönünde 10 defa

215 x 161 x 50

196.9 x 142.9

Yaklaşık 820g Yaklaşık 840g

o o

o o

E

Power Giriş Terminali

COM2

USB Host

B

D

F

COM1

USB Slave

Pil Kapağı / Sistem Tuşu

Titreşim Direnci

Ölçüler(W) x (H) x (D) mmPanel Kesim Ölçüsü

(W) x (H) mm

Ağırlık(4) Ölçüler

A B

NOTE1)Arka ışık yarım-ömrü, HMI maksimum akımla beslendiğinde orijinal aydınlatmanın %50 düşürüldüğü anlamına gelir.

o

Yukarıda gösterilen arka ışık LED aydınlatma ömrü 25 C ‘de derecede normal sıcaklık ve rutubet ortamındatahmin edilen değerlerdir.Güç tüketimi HMI ünitesinin hiç bir cihaza bağlı olmadan boş olarak tükettiği gücü gösterir. Normal çalışmadaHMI’nın boşken tükettiği gücün 1.5 veya 2 katı güç verebilen besleme kaynağı kullanılması tavsiye edilir.Herhangi bir ihbar olmadan bu dökümanın içeriği değiştirilebilir. En son güncellenmiş halini firmamızdan talepedebilir yada aşağıdaki link adresinden indirebilirsiniz http://www.delta.com.tw/

2)

3)

A Dokunmatik Ekran / Display B Power LED Indikatör

DOP-B07S411K (Ön Görünüm) DOP-B07S411 / DOP-B07S411K

196.9+0.04"+1.0

0 (7.75" -0 )

+1.0 (5.63"+0.04" )-0

0

(1) ÖnsözDELTA’nın DOP-B serisi operatör panellerini seçtiğiniz için teşekkürler. Bu bilgi dökümanı Delta HMIkurulum, bağlantı, bakım ve kontrolünde kullanıcıya yardımcı olacaktır. Doğru kullanım için ürünükullanmadan önce bu dökümanı mutlaka okuyunuz. Kurulum, bağlantı ve çalışma yapmadan öncegüvenlik uyarılarını tamamen anladığınızdan emin olunuz. Bu dökümanı daha sonra da kullanmak için iyimuhafaza ediniz. Lütfen aşağıdaki güvenlik uyarılarına dikkat ediniz:

Ürünün kurulumunu yanıcı gaz ve sıvılardan uzak kuru ve temiz ortamlara yapınız.Bağlantıları yaparken tüm bağlantı kurallarının sağlandığından emin olunuz.HMI’nın toprak bağlantısının doğru yapıldığından emin olunuz. Topraklama metodunun ürünün

kurulduğu ülke standartlarına uygun olduğuna emin olunuz (NFPA 70: National Electrical Code,2005 Ed.).

HMI enerjili iken kablo bağlantısı yapmayınız ya da sökmeyiniz.Çalışma sırasında enerji besleme terminallerine dokunmayınız. Aksi halde elektrik şoku olabilir.

Ürünün kullanımı ile ilgili sorularınız için, lütfen teknik servisimizle bağlantıya geçiniz.Herhangi bir ihbara gerek kalmaksızın bu bilgi dökümanının içeriği değiştirilebilir. Güncellenmiş versiyonuelde etmek için teknik servise danışabilir veya internet adresinden indirebilirsiniz. http://www.delta.com.tw/

A

B

Kullanıcı-tanımlı Fonksiyon Tuşları / Sistem Tuşları

A Kullanıcı-tanımlı Fonksiyon Tuşları: F1, F2, F3, F4

Sistem Tuşları: , , , SYS

: Power LED Indikator

HMI normal çalıştığında yeşil yanar.

: Çalışma LED Indikator (Mavi) (Not 1)

C(5) Özellikler

MODEL

LCD MODÜLDisplay Tipi

Çözünürlük

o o

o

Haberleşme sağlandığı zaman veya data iletişimi sırasında çalışma LED’i mavi flash yapar .

(Lütfen aşağıdaki Not 1’i inceleyiniz).

: Sağ kenar: Alarm LED Indikator (Kırmızı)

Herhangi bir alarm aktif olduğunda Alarm LED indikator kırmızı flash yapar.

D Touch Screen / Display

MOD 1

RS-232123456789

RXDTXD

GND

RTSCTS

NOTE

1. Çalışma LED indikatörü (mavi) tanımlaması kullanıcı tarafından belirlenebilir.

4 adet kullanıcı tanımlı tuş +4 adet sistem tuşu

Gerçek Zaman Saati(RTC)

Soğutma Metodu

Güvenlik OnayıDOP-B07S411 / DOP-B07S411K COM2 Port

MODE1

COM Port PIN

DOP-B07S411 / DOP-B07S411K (Arka Görünüm)

MODE2

COM2

D+

COM3

MODE3

COM2 COM3

TXD+RXDTXD

D+GND

D-

RXD+GND

TXD-

RXD-

E

FSu Geçirmezlik Derecesi

Çalışma Voltajı (Not2)

Dayanma Voltajı

Güç Tüketimi (Not 2)

COM2

RS-232

COM3

RS-485 RS-485 RS-485 RS-232 RS-422

PIN1

123456789

RXDTXD

D+GND C

D

B

Backup Pili

Backup Pil Ömrü

Çalışma SıcaklığıD- D-

Not 1: Boş = Bağlantı Yapılmaz.A Saklama Sıcaklığı

Rutubet Oranı(3) Parça İsimleriDOP-B07S411 (Ön Görünüm) A

C