Doc. No: 32-0007-01
FIRERAY®
ASM SECURITY KFT - HUNGARYPRODUCT PRESENTATION
SEMINARWEDNESDAY SEPTEMBER 15TH
2010
Doc. No: 32-0007-01
FIRERAY®
WELCOME TO PRESENTATION ON OPTICAL BEAM SMOKE
DETECTORSBY BEN WILLIAMSON
EXPORT SALES MANAGER
• Company established in 1974• Part of Halma PLC since 2000
• All products designed and manufactured in Hitchin in the UK
• Employs 40 people• Annual turnover over £7.5m• 75% of sales are to export
markets• Export to over 80 countries globally
FIRE FIGHTING ENTERPRISES Ltd.
• Market leader with over 650,000 Optical Beams sold worldwideFFE manufacture a complete RANGE of Optical Beam
Detectors
Hitchin
Infra-red light Optical Beam axis and centre
WHAT IS AN OPTICAL BEAM SMOKE DETECTOR?
An Optical Beam Smoke Detector is a device which monitors the amount of Infrared light transmitted from a light source to a photosensitive Receiver across an
open area to be protected. If obscuration of the Optical Beam path exceeds a set value due to smoke, the
Optical Beam sends a signal to the Fire Alarm Control Panel
If smoke obscures the light path from Transmitter (Tx) to Receiver (Rx)
above a preset level, an alarm condition is signalled to the Fire Alarm Control Panel
PRINCIPLE OF OPERATION
FIRERAY 2000EExd
SPECIAL APPLICATIONS
RefineriesFlour mills
Munitions factories and storesFlammable liquid storesFlammable gas stores
Flammable powder storesIndustrial plants and warehouses
Power stations
ATEX APPROVED
WHERE AREOPTICAL BEAM SMOKE DETECTORS
USED?
AtriumsConference CentresExhibition Centres
Shopping MallsAircraft Hangars
MuseumsAirportsStables
Sports CentresLeisure Centres
Warehouses
Manufacturing PlantsHistoric Buildings
Airports
CONCLUSION
FIRERAY optical beam smoke detectors are the ideal type of detector to choose for many large installations. They are an efficient and economical way of protecting lives, equipment and properties where:
Areas are wideCeilings are highCost of installation and servicing need to be lowArchitecture cosmetics / aesthetics are importantCeilings are ornate
• Multi-head Capability
• Laser Alignment
• Fast Auto-Alignment
• Auto-Optimise
• ‘One-Wire Communications’
(Communication-over-power)
• ‘First Fix’ System
• 'Easy-Fit' ‘Second Fix’ System
• System Controller Mounted at Low Level
WHY USE FIRERAY5000?
• Reduced Installation & Commissioning Time & Service
Costs
• 5 year warranty
• Designed and fully assembled and tested at FFE’s UK
factory
• International Approvals VdS, UL, LPCB
• Minimal number of reflective prisms needed
for range
• Extensive range of accessories
• Multi language Quick Start Guide & User Manual
WHY USE FIRERAY5000?
FIRERAY5000 ACCESSORIES
Universal Bracket
4 Prism Plate 1 Prism Plate Prism Mount Plate
First Fix Base
Indication LED’s
LCD Display
Keypad
Det. 1
Det. 2
Det. 3 Det.
4 Sys. Con.
SYSTEM CONTROLLER
Knock Outs
• Clear line of sight
• Rigid mounting
• Reflections and obstructions
• Crosstalk
• Light sources and other challenges
INSTALLATION BASICS
INSTALLING AN OPTICAL BEAM SMOKE DETECTOR
Metal panels Wooden walls Cladded walls Lighting or electrical
hangars
Brick / block walls Structural SteeI beams Concrete walls Metal-frame assemblies Load-bearing walls
STRUCTURE
MAINTAINCOMMISSIONINSTALLSPECIFYWHEREWHAT
EXTRACT FROM STANDARDS
BS5839: “Transmitters, Receivers and any Reflectors should be
mounted on solid construction that will not be subject to movement, likely to affect the alignment of the optical beam, as a result of changes in temperature or imposed load”
UL: “Projected beam-type detectors and mirrors shall be
mounted on stable surfaces to prevent false or erratic operation due to movement.”
• Conduct a Fault test by fully covering the
Reflector, within two seconds, with non-
reflective material
TESTING A FIRERAY 5000 OPTICAL BEAM SMOKE DETECTOR
• Conduct a Smoke test by gradually covering the
Reflector, taking longer than two seconds, with
non-reflective material
To confirm successful
alignment
This ensures successful
alignmentMAINTAINCOMMISSIONINSTALLSPECIFYWHEREWHAT
MAINTAINING AN OPTICAL BEAM SMOKE DETECTOR
To ensure the system continues to operate correctly:
• Check for visual damage regularly
• Check installation remains mechanically and electrically correct
• Check there have been no major changes to the environment such as line of sight, obstructions, reflections, strong light sources etc.
• Clean the system regularly
• Check operation of the system with regular Fault and Fire tests
MAINTAINCOMMISSIONINSTALLSPECIFYWHEREWHAT
Detector mounted at high level
System Controller mounted at user level
Fire Panel
CONNECTING FIRERAY5000 TO THE FIRE SYSTEM
Up to 100m
FIRERAY5000 MARKET ADVANTAGES
• Multi-head
• Built in Laser
• Fast alignment speed (3 minutes) and
reliability
• Minimal number of reflective prisms
required
• Easy to fit First Fix base
FIRERAY5000 MARKET ADVANTAGES
• Icon-based menu system
• Error Codes
• System responsiveness
• Performs to electrical specification
• Has constant current consumption – even at start-up
CONCLUSION
FIRERAY optical beam smoke detectors are the detector to choose for many large installations. They are an efficient and economical way of protecting lives, equipment and properties where:
Areas are wideCeilings are highCost of installation and servicing need to be lowArchitecture cosmetics / aesthetics are importantCeilings are ornate
www.ffeuk.com
THANK YOU FOR COMING TO OUR PRESENTATION TODAY
FIRERAY