Nokia Siemens Networks
WCDMA RNC Rel. RN6.0, Site
Documentation, Issue 01
WCDMA RNC Engineering Description
DN0938143
Issue 2-1
Approval Date 2011-1-25
Confidential
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 2/122
2 DN0938143
Issue 2-1
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2011. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the “Legal, Safety
and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-
anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,
Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-
satzes.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 3/122
DN0938143 3
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
Table of contentsThis document has 122 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 About WCDMA RNC Engineering Description. . . . . . . . . . . . . . . . . . . . 11
2 RNC Hardware Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3 IPA2800 System Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 Internal Messaging and Resource Allocation. . . . . . . . . . . . . . . . . . . . . 16
3.2 Computing System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.3 Redundancy Principles for IPA2800 Network Elements . . . . . . . . . . . . 18
4 Mechanical Construction of the IPA2800 Network Elements. . . . . . . . . 22
4.1 Cabinets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.1.1 EC216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.1.2 IC186/-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.1.3 Dimensions of Cabinets in Floor Rail on Free-standing Installations. . . 25
4.2 Subracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.3 Plug-in Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.4 Cabling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.4.1 General Cabling Principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.5 Cooling Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5 Cabinet and Subrack Descriptions for RNC2600. . . . . . . . . . . . . . . . . . 32
5.1 RNC2600 Cabinet Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
5.2 Equipment in the Subracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345.3 RNC2600 Upgrades and Expansions in RN6.0. . . . . . . . . . . . . . . . . . . 37
5.3.1 Optional Expansions for RNC2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
6 Cabinet and Subrack Descriptions for RNC450. . . . . . . . . . . . . . . . . . . 38
6.1 RNC450 Cabinet Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
6.2 Equipment in the subracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.3 Upgrades and Expansions for RNC450 in RN6.0 . . . . . . . . . . . . . . . . . 43
6.3.1 Optional Upgrades and Expansions for RNC450 . . . . . . . . . . . . . . . . . 43
6.4 RNC450 Upgrades and Expansions in RN5.0. . . . . . . . . . . . . . . . . . . . 44
6.4.1 Mandatory Upgrades for RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.4.2 Optional Upgrades and Expansions for RNC450 . . . . . . . . . . . . . . . . . 446.5 RNC450 Upgrades and Expansions in RN4.0. . . . . . . . . . . . . . . . . . . . 44
6.5.1 Mandatory Upgrades for RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.5.2 Optional Upgrades and Expansions for RNC450 . . . . . . . . . . . . . . . . . 44
7 Cabinet and Subrack Descriptions for RNC196. . . . . . . . . . . . . . . . . . . 46
7.1 RNC196 Cabinet Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.1.1 RNC196 Step 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
7.1.2 RNC196 Step 6 and RNC196 Step 7. . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.1.3 Hardware Upgrade to RNC196 Step 6 and RNC196 Step 7 . . . . . . . . . 51
7.2 Equipment in the Subracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.3 Upgrades and Expansions for RNC196 in RN6.0 . . . . . . . . . . . . . . . . . 57
7.3.1 Optional Upgrades and Expansions for RNC196 . . . . . . . . . . . . . . . . . 57
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 4/122
4 DN0938143
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
7.4 Upgrades and Expansions for RNC196 in RN5.0. . . . . . . . . . . . . . . . . . 58
7.4.1 Mandatory Upgrades for RNC196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
7.4.2 Optional Upgrades for RNC196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
7.5 Upgrades and Expansions for RNC196 in RN4.0. . . . . . . . . . . . . . . . . . 587.5.1 Mandatory Upgrades for RNC196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
7.5.2 Optional Upgrades for RNC196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
8 Functional Unit Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.1 Functional Unit Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
8.2 Management, Control Computer and Data Processing Units. . . . . . . . . 60
8.2.1 DMCU, Data and Macro Diversity Combining Unit . . . . . . . . . . . . . . . . . 60
8.2.2 GTPU, Gateway Tunneling Protocol Unit . . . . . . . . . . . . . . . . . . . . . . . . 62
8.2.3 ICSU, Interface Control and Signalling Unit . . . . . . . . . . . . . . . . . . . . . . 66
8.2.4 Integrated OMS, Operation and Maintenance Server and its sub-units . 70
8.2.5 ESA40-A, Ethernet Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8.2.6 ESA24, Ethernet Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
8.2.7 ESA12, Ethernet Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
8.2.8 OMU, Operation and Maintenance Unit and Its Subunits . . . . . . . . . . . . 76
8.2.9 RRMU, Radio Resource Management Unit . . . . . . . . . . . . . . . . . . . . . . 83
8.2.10 RSMU, Resource and Switch Management Unit . . . . . . . . . . . . . . . . . . 86
8.3 Switching and Multiplexing Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
8.3.1 A2SU, AAL2 Switching Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
8.3.2 MXU, Multiplexer Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
8.3.3 SFU, Switching Fabric Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
8.4 Network Interface Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
8.4.1 NIP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1008.4.2 NIS1 / NIS1P. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8.4.3 NPS1 / NPS1P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
8.4.4 NPGE / NPGEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
8.5 Timing, Power Distribution and Hardware Management Subsystems . 104
8.5.1 TBU, Timing and Hardware Management Bus Unit . . . . . . . . . . . . . . . 104
8.5.2 HMS, Hardware Management Subsystem . . . . . . . . . . . . . . . . . . . . . . 109
8.5.3 Power Distribution Subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
8.6 EHU, External Hardware Alarm Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . 116
9 Interfaces to the Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
9.1 Power Supply and Grounding Interfaces . . . . . . . . . . . . . . . . . . . . . . . 1179.2 PDH TDM Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
9.3 SDH TDM Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
9.4 External Synchronisation Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
9.5 External HW Alarm Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
9.6 Ethernet/LAN Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
9.7 Mouse, Keyboard, VDU, SCSI and Printer Interfaces . . . . . . . . . . . . . 122
9.8 RS232 Service Terminal Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 5/122
DN0938143 5
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
List of figuresFigure 1 Block diagram of the RNC2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 2 Block diagram of the RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 3 EC216 cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 4 IC186-B cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 5 Dimensions of the EC216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 6 Dimensions of the IC186-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 7 Dimensions of EC216 / IC186-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 8 SRA1 subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 9 Layout options for the RNC2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 10 RNAC cabinet in RNC2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 11 RNBC cabinet in RNC2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 12 Layout options for the RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 13 RNAC cabinet in RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Figure 14 RNBC cabinet in RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 15 Layout options for the RNC196 (with optional cabling cabinet) . . . . . . . 46
Figure 16 RNAC cabinet - RNC196 step 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 17 RNBC cabinet - RNC196 steps 2-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Figure 18 RNAC cabinet - RNC196 steps 6 and 7. . . . . . . . . . . . . . . . . . . . . . . . . 50
Figure 19 RNBC cabinet - RNC196 steps 6 and 7. . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 20 Configuration steps RNC196 step 6 and 7 with mandatory hardware
changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Figure 21 DMCU's interfaces - CDSP-DH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 22 DMCU's interfaces - CDSP-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 23 GTPU’s interfaces - CCP1D-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Figure 24 GTPU's interfaces - CCP18-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 25 GTPU's interfaces - CCP18-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 26 GTPU's interfaces - CCP10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 27 ICSU’s interfaces - CCP1D-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 28 ICSU's interfaces - CCP18-C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 29 ICSU's interfaces - CCP18-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 30 ICSU's interfaces - CCP10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Figure 31 Integrated OMS interfaces (MCP18-B) . . . . . . . . . . . . . . . . . . . . . . . . . 71
Figure 32 Integrated OMS storage device interfaces. . . . . . . . . . . . . . . . . . . . . . . 72
Figure 33 SCSI connection principle for integrated OMS storage devices (MCP18-B)
73
Figure 34 ESA40-A’s interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 35 ESA24's interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 36 ESA12's interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Figure 37 OMU’s interfaces - CCP1D-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 38 OMU's interfaces - CCP18-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 39 OMU's interfaces - CCP10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 40 OMU’s storage device interfaces - HDS-C . . . . . . . . . . . . . . . . . . . . . . 80
Figure 41 OMU's storage devices' interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 42 SAS connection principle for OMU storage devices - CCP1D-A and HDS-C
82
Figure 43 SCSI connection principle for OMU storage devices - CCP18-A and HDS-B
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 6/122
6 DN0938143
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
82
Figure 44 SCSI connection principle for OMU storage devices - CCP10, HDS-A and
MDS-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Figure 45 RRMU's interfaces - CCP18-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Figure 46 RRMU's interfaces - CCP18-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Figure 47 RRMU's interfaces - CCP10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Figure 48 RSMU’s interfaces - CCP1D-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Figure 49 RSMU's interfaces - CCP18-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Figure 50 RSMU's interfaces - CCP18-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 51 RSMU's interfaces - CCP10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Figure 52 ATM connections to SFU - RNC450 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 53 A2SU's interfaces - AL2S-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Figure 54 A2SU's interfaces - AL2S-B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Figure 55 MXU's interfaces - MX1G6 and MX1G6-A . . . . . . . . . . . . . . . . . . . . . . . 95
Figure 56 MXU's interfaces - MX622 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96Figure 57 SFU's interfaces - SF20H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Figure 58 SFU's interfaces - SF10E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Figure 59 SFU's interfaces - SF10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Figure 60 NIP1's interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Figure 61 NIS1's interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Figure 62 NPS1(P) interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Figure 63 NPGE(P) interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Figure 64 TSS3/-A's interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Figure 65 TBUF's interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Figure 66 Dual Star timing bus cabling principles . . . . . . . . . . . . . . . . . . . . . . . . . 108
Figure 67 Connection principle of the duplicated clock distribution bus . . . . . . . . 109
Figure 68 Block diagram of the HMS subsystem . . . . . . . . . . . . . . . . . . . . . . . . . 110
Figure 69 Connection principle of the duplicated HMS bus . . . . . . . . . . . . . . . . . 111
Figure 70 PD30/PD20's interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Figure 71 General power distribution principle for RNC . . . . . . . . . . . . . . . . . . . . 115
Figure 72 DC/DC converter structure in a plug-in unit . . . . . . . . . . . . . . . . . . . . . 116
Figure 73 Power supply interfaces of CPD120-A with DC/I principle . . . . . . . . . . 118
Figure 74 Power supply interfaces of CPD120-A with DC/C principle . . . . . . . . . 119
Figure 75 Power supply interfaces of CPD80-B with two connection alternatives and
optional ETS grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Figure 76 Power supply interfaces of CPD80-A and their connection alternatives:
DC/I and DC/C principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 7/122
DN0938143 7
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
List of tablesTable 1 Computing platform hierarchy levels for IPA2800 RNC . . . . . . . . . . . . 17
Table 2 Redundancy principles of the functional units in the RNC . . . . . . . . . . 20
Table 3 Number of units in RNC2600 subracks . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 4 Maximum number of units in the RNC2600 for each configuration step 35
Table 5 Numbers of units in RNC450 subracks . . . . . . . . . . . . . . . . . . . . . . . . . 40
Table 6 Maximum number of units in the RNC450 for each configuration step . 41
Table 7 Minimum hardware level and configuration expansion for RNC196 step 6
53
Table 8 Minimum hardware level and configuration expansion for RNC196 step 7
53
Table 9 Number of units in RNC196 subracks . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 10 Maximum number of units in RNC196 for each configuration step . . . . 56
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 8/122
8 DN0938143
WCDMA RNC Engineering Description
Id:0900d805808219be
Confidential
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 9/122
DN0938143 9
WCDMA RNC Engineering Description Summary of changes
Id:0900d80580821ae7
Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Issue 2-1
Updated issue for release RN6.0. Minor corrections in release contents.
SAS bus cabling principle added for HDS-C.
Dual Star timing bus configuration added.
Issue 2-0
First draft issue for release RN6-0 pre-release.
Issue 1-4
In Table 1 Computing Platform Hierarchy Levels, operating system for MCP18-B has
been corrected to Linux.
Issue 1-3
Reference to Hardware upgrades from RNC196 step 7 to step 8 removed because this
document is not ready.
Issue 1-2
MCP18-B removed.
added text to clarify the difference between Upgrade and Expansion in Chapter 1.
Added Chaper 5.3 RNC2600 Upgrades and Expansions in RN5.0.Chaper 6.3.1, added
Minimum hardware requirement for all configurations in RN5.0: the disk size for Inte-
grated OMS must be at least 147 GB. Added reference to Hardware Expansion for RNC450 and Upgrading RNC450 to RNC2600Chaper 6.3.2, Added reference to
Hardware Expansion for RNC450 and Upgrading RNC450 to RNC2600Chaper 6.4.1,
Added reference to Hardware Expansion for RNC450 and Upgrading RNC450 to
RNC2600Chaper 7.3.1, added Minimum hardware requirement for all configurations in
RN5.0: the disk size for Integrated OMS must be at least 147 GB. Chaper 7.3.2, Added
reference to Hardware Expansion for RNC196.Chaper 7.4.1, Added reference to
Hardware Expansion for RNC196.
Issue 1-1
Chapter 1: Noted that the upgrades supported in RN4.0 are also supported in RN5.0.
Added RNC196 step 5 to step 6 and 7. Added Full CDSP-DH upgrade.Chapter 6.3.3 Optional upgrades and expansions for RNC450:Noted that the upgrades
supported in RN4.0 are also supported in RN5.0. Added full CDSP-DH upgrade.
Chapter 6.4.2 Optional upgrades and expansions for RNC450: Added Full CDSP-DH
upgrade.
Chapter 7.1.4 RNC196 step 8 and chapter 7.1.5 Hardware upgrade to RNC196 step 8
was updated according to new architecture.
Chapter 7.3.2 Optional upgrades for RNC196: Added RNC196 step 7 to step 8 upgrade.
Added Full CDSP-DH upgrade. Noted that the upgrades supported in RN4.0 are also
supported in RN5.0.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 10/122
10 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821ae7
Confidential
Summary of changes
Issue 1-0
Issue 1-0 is the first issue for the RNC2600 network element with RN5.0 software.
The main, optional change from RN4.0 is that the functional unit OMS can be selected
between the current integrated OMS or an external standalone OMS network element.For RN5.0 new deliveries, the standalone OMS is recommended.
With the integrated OMS, its plug-in unit MCP18-B and the related two HDDs must also
be removed, as well as all SCSI connections between OMS and the HDD, and the LAN
connection between OMS and the Ethernet Switch (ESA24).
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 11/122
DN0938143 11
WCDMA RNC Engineering Description About WCDMA RNC Engineering Description
Id:0900d805807fd6f1
Confidential
1 About WCDMA RNC Engineering DescriptionThis Engineering Description provides the basic information needed for the installation
planning of the WCDMA RNC. It does not include the installation planning instructions
for the site power supply equipment or for the PDH and alarm distribution frames.
WCDMA RNC Engineering Description provides the following information:
• System architecture
• Mechanical construction of the network element
• Cabinet and subrack descriptions for RNC2600
• Cabinet and subrack descriptions for RNC450
• Cabinet and subrack descriptions for RNC196
• Functional unit descriptions
• Interfaces to the environment
New deliveries, expansions, and upgrades
This document describes the hardware configurations, mechanics, and electromechan-
ics for RN6.0 level RNC2600 new deliveries and expansions, as well as upgrades and
expansions for previously delivered RNC450 and RNC196 at RN5.0 and RN4.0
hardware level. Cabinet mechanics used in the different delivery types are described in
section Mechanical construction of the IPA2800 network elements. Hardware configu-
rations for RNC450 are described in section Cabinet and subrack descriptions for
RNC450 and for RNC196 (Upgrading to RNC196 step 6 and 7, upgrading RNC196 step
7 to step 8) in section Cabinet and subrack descriptions for RNC196.
Information on Upgrades at RN6.0 level will be available at a later date.
For more information on upgrades at RN5.0 hardware level, see Upgrading from RN4.0
OMS to RN5.0 OMS and Upgrading from integrated RNC OMS to standalone RNC
OMS.
For more information on upgrades at RN4.0 hardware level, see Upgrading RNC450 to
RNC2600 , Replacing CDSP-C with CDSP-DH and Enabling HSDPA Capacity
Enhancement in CDSP-DH and SFU and IP Upgrade.
Full CDSP-DH upgrade is supported at RN4.0 and RN5.0 hardware level, see Replacing
CDSP-C with CDSP-DH and Enabling HSDPA Capacity Enhancement in CDSP-DH
and SFU and IP Upgrade.
All upgrades supported in RN4.0 are also supported in RN5.0.
The term “expansion” in this document means that extra hardware is added to RNC to
provide new configuration step, for example from RNC2600 step 1 to RNC2600 step 3.
Term “upgrade” means that existing hardware is some how changed to provide the use
of new feature or capacity level, for example from RNC196 step 5 to RNC196 step 6/7,
RNC196 step 7 to 8, IP upgrade, etc.
Other related documentation
The site requirements for the RNC are described in the document Installation Site
Requirements for MGW and RNC . It provides the following information:
• Technical specifications
• General hardware platform requirements
• Equipment room requirements
• Site power supply
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 12/122
12 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807fd6f1
Confidential
About WCDMA RNC Engineering Description
• Grounding and bonding
• Electromagnetic compatibility
• Operational environment
•Ventilation in the equipment rooms
• Specifications of interfaces to the environment
For information on changes in previous releases, see Upgrades and expansions for
RNC196 in RN3.0/RN2.2 and NEMU, Network Element Management Unit and its
subunits in WCDMA RNC Engineering Description documents for previous releases and
Product Description for RNC2600 .
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 13/122
DN0938143 13
WCDMA RNC Engineering Description RNC Hardware Changes
Id:0900d80580841885
Confidential
2 RNC Hardware ChangesThis section summarises the differences in the hardware implementation between
RN5.0 and RN6.0.
New plug-in units
Compared to RNC2600 on RN5.0 level, RNC2600, RN450 and RN196 on RN6.0 level
contain the following new plug-in units:
• CCP1D-A
Control Computer 1 with dual core processor, variant A
Used for ICSU, OMU and RSMU functional units.
• ESA40-A
Ethernet Switch for A series with 40 ports
• HDS14-A
Hard Disk SAS, variant A
• HDS-C
Adapter for hard disk
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 14/122
14 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c824
Confidential
IPA2800 System Architecture
3 IPA2800 System ArchitectureThe IPA2800 network elements have a distributed processing architecture based on a
modular software and hardware structure. The distribution of processes is achieved by
using a multi-processor system, in which the functions of the network element are
divided among several functional units. In the IPA2800 network element, each functional
unit usually consists of one plug-in unit, which has a fixed capacity. The capacity
reserved for a given function can be increased by simply installing additional units of the
appropriate type to the configuration – another benefit from the modular structure.
Each functional unit has a separate task group to handle. For example, the ATM Switch
Matrix has been organised as a separate unit, Switch Fabric Unit (SFU), and it is con-
trolled by another unit, called Resource and Switch Management Unit (RSMU). The key
operation and maintenance functions are performed by the Operation and Maintenance
Unit (OMU), the external SDH STM-1 and Ethernet interfaces are provided by the
Network Interface Units (NPS1(P)) and (NPGE(P)), respectively, and so on.
Each functional unit has its own, separate hardware and software; some of them are
equipped with a dedicated Pentium®II, Pentium®III or Pentium®M 745-type computer.
These units are referred to as computer units, some of which have storage devices as
dedicated sub-units. The hardware of the functional units and the tasks each unit
handles are described in more detail in chapter Functional unit descriptions. Further
information is available in the Product Description.
The figures below present the block diagrams of the Radio Network Controller,
RNC2600 and RNC450, their functional units and the internal and external interfaces.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 15/122
DN0938143 15
WCDMA RNC Engineering Description IPA2800 System Architecture
Id:0900d8058083c824
Confidential
Figure 1 Block diagram of the RNC2600
RSMU
SFU
ICSU
DMCU
DN70618302
MANAGEMENT, CONTROL COMPUTER AND D ATA PROCESSING UNIT
SWITCHING AND MULTIPLEXING UNIT
NETWORK INTERFACE UNIT
MXU
DMCU
ICSU
MXU
EHU
NPGE(P)
OMS*
HDD*
OMU
WDU
MXU
TBU
Ethernet
Ethernet
Ethernet
NPS1(P)
SWU
* Optionally, the integrated OMS and the related HDDs can be removed as of RN5.0.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 16/122
16 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c824
Confidential
IPA2800 System Architecture
Figure 2 Block diagram of the RNC450
3.1 Internal Messaging and Resource Allocation
In terms of network element architecture, perhaps the most significant single feature of the ATM technology is that it allows for relatively easy designing of switching devices
with high capacity and low delay. A primary bottleneck in the design of the 2nd genera-
tion systems, the switching capacity is no longer such a limiting factor in 3rd generation
systems. This is reflected in the architecture of the RNC in the following ways:
• Nearly all of the network element's internal traffic is routed through its switching
fabric.
In the IPA2800 network elements, the message bus between its units consists of
standard ATM virtual channels routed through the switching fabric.
However, the IPA2800 has timing and Hardware Management (alarm) buses
separate from the ATM connections. The timing bus has been separated to ensure
that the strict timing requirements of the ATM technology are met, while an individualHardware Management bus ensures that some basic functions in the network
SFU
TBU
EHU
NIS1
DMCU
Iu
Iur Iub
E1/T1/JT1
ATM
ICSU
RRMU
RSMU
OMU
WDUFDU
A2SU
GTPU
OMS */NEMU
IuIur Iub
STM-1 ATM
Harddisk
ETHERNET
100 BASE Tx
DN01128754
MANAGEMENT, CONTROL COMPUTER AND DATA PROCESSING UNIT
SWITCHING AND MULTIPLEXING UNIT
NETWORK INTERFACE UNIT
MXU
A2SU
GTPU
DMCU
ICSU
A2SU
GTPU
DMCU
ICSU
NIP1
MXU
MXU
DMCU
* OMS replaces NEMU in RN3.0
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 17/122
DN0938143 17
WCDMA RNC Engineering Description IPA2800 System Architecture
Id:0900d8058083c824
Confidential
element can be carried out without any support from its control units when the
network element is being taken into use, upgraded or serviced, or during normal
operation.
• Virtually all DSPs (Digital Signal Processors) in the system can be used by any
control computer.
In the IPA2800 network elements, the DSPs are organised as pools whose services
are available to the control computers through the ATM virtual message bus. This
ensures optimal use of the system's DSP resources. As a consequence, the plug-in
units containing DSPs have been separated from the control computers on the func-
tional unit level and they form functional units of their own.
This kind of architecture has been achieved by enabling the routing of the user data
of a call multiple times through the switching fabric while it is being processed.
3.2 Computing System
The computing system of the IPA2800 network elements consists of various micropro-
cessor based computers and microcontrollers with either proprietary or standard oper-
ating systems, as well as standard message transfer protocols. It is organised according
to a four-level hierarchy, as shown in the table below.
Management computer unit MCP18-B and control computer unit CCP1D-
A/CCP18-C/CCP18-A/CCP10
The MCP18-B and CCP1D-A/CCP18-C / CCP18-A / CCP10 plug-in units are used as
the management computer units and control computer units, respectively, in the
IPA2800 network elements. Both are single board computers with an onboard PCI bus.
The CCP1D-A has a dual core Intel Jasper Forest processor. The MCP18-B andCCP18-C / CCP18-A are based on Pentium M 745 1800 MHz microprocessor.
Level Type Processor Operating
system
PIUs Communica-
tion to upper
level/other
units
Level 4 Management
computer
Intel P M 745
Intel PIII
Linux MCP18-B TCP/IP
Level 3 Control
computer
Intel Pentium M
(CCP18-C /
CCP18-A)
Intel PIII
(CCP10)
DMX with
POSIX
CCP1D-A/
CCP18-C/
CCP18-A/
CCP10
LAN/Ethernet,
ATM virtual
channels
Level 2 Unit computer Motorola Power-
Quicc II
Chorus MX1G6/-A,
SF10E,
AL2S-D/-B,
CDSP-C/-DH,
NP2GE-B,
NP8S1-B
ATM virtual
channels
Level 1 Control proces-
sor
8-bit microcon-
troller
No OS
needed
Embedded in
all PIUs
Selected case
by case
Table 1 Computing platform hierarchy levels for IPA2800 RNC
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 18/122
18 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c824
Confidential
IPA2800 System Architecture
As of RN5.0, the functional unit OMS can be selected between the current integrated
OMS or an external standalone OMS network element. For RN5.0 new deliveries, the
standalone OMS is recommended.
As for RN6.0 new deliveries only standalone OMS is applicable. Usage of CCP1D-ACPU with its hard disks are not supported with standalone OMS.
For more information on the MCP18-B and CCP18-C / CCP1D-A / CCP18-A / CCP10
plug-in units, see the individual Plug-in Unit Descriptions online.
3.3 Redundancy Principles for IPA2800 Network Elements
The reliability of the operations in the IPA2800 network elements has been ensured by
backing up all crucial parts of the system following various redundancy principles, as
described in the sections below. Functional unit-specific redundancy principles are
named in chapter Functional unit descriptions.
Redundancy of the functional units
Different redundancy techniques are used for backing up different types of functional
units. The Operation and Maintenance Unit, the main Switch Fabric, the radio resource
and switch control units along with all crucial databases are backed up according to the
2N redundancy principle, that is, by duplication according to the hot-standby method.
When a defect is detected in an active functional unit, a spare unit is set active by an
automatic recovery function. The spare unit is designated for only one active unit, and
the software in the unit pair is kept synchronised.
Most units with 2N redundancy, except for most of the subrack-specific Timing Buffers
and multiplexers, are located in the two first subracks of the network element. The two
units of a mutually redundant pair are placed in different subracks. Switchover can be
performed between units of a redundant unit pair independently of the other correspond-
ing pairs, which means that no subrack-level switchover procedure is needed in the
network element.
The STM-1 network interface units can optionally use 2N redundancy. Until RN3.0, NIS1
unit is the default non-redundant unit. As of RN4.0, NPS1 and NPGE units are the
default non-redundant units. These can be turned into redundant, 2N duplicate, units
(NIS1P or NPS1P and NPGEP, respectively) providing additional equipment protection
by adding another NIS1, NPS1 or NPGE unit to the network element or by changing the
cabling of the existing two units. In NIS1, the SDH transmission protection is ensured by
the MSP 1+1, bidirectional protection switching mode, where the traffic is carried via two
multiplex sections.
The signalling units, AAL2 switch, and the units handling user or control plane functions
are backed up according to the N+1 or SN+ principle. N+1 principle means that there is
one spare unit available ready to take over the tasks of a faulty unit. Load sharing, SN+,
means that the workload is shared between all devices, and if one malfunctions, the
other units are able to carry the full load.
Ensuring reliability at unit level
In the Intel processors, the following methods are used to ensure proper operation:
• Error correcting RAM in critical parts
• ECC in read-write memories
•
Parity checks in data transmission on the PCI bus• Reporting on certain error events in data transactions on the system bus
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 19/122
DN0938143 19
WCDMA RNC Engineering Description IPA2800 System Architecture
Id:0900d8058083c824
Confidential
• Memory area protection (standard Intel processor capability)
• Time-out supervision
• Continuous supervision of the functioning of processes including restarts, when
required• Continuous testing of operations (as a background run) in all computer units
Units without nominal redundancy
Some of the functional units of the network element do not have redundancy at all.
These are units which interface the network element to the environment. As of RN4.0,
the non-redundant units are NPGE, NPS1 and integrated OMS. As of RN5.0, the func-
tional unit OMS can be selected between the current integrated OMS or an external
standalone OMS network element. For RN5.0 new deliveries, the standalone OMS is
recommended. Integrated or standalone OMS is left without backup because a failure
in it does not prevent the switching or cause any drop in the capacity available; the
network element only loses both its local and upper-level operation and maintenance
interface.
The network interfaces are more crucial to the whole system. The PDH network inter-
face units are organised as pools of resources, with several units available at a time to
handle an assignment. It is recommended that connections to any given direction will be
divided between two or more units located in different subracks. This ensures that a
failure in, for example, one of the power supply plug-in units will not interrupt the traffic
to one direction altogether. If there is surplus capacity available for the network inter-
faces, it is recommended that it be used for backing up the crucial connections and
sharing the load between all the network interfaces available for connections towards
that direction.
Redundancy of the power distribution, timing distribution, and Hardware Manage-ment Subsystems
Virtually the entire power distribution chain from the rectifiers and power feed cables to
individual pieces of equipment in the cabinets has been duplicated to minimise the risk
of downtime due to power failures in the IPA2800 equipment or cabling. The redundancy
for the power supply from the rectifiers to the cabinets has been achieved by duplicating
the power inputs in each cabinet, along with the input cables. The two units are placed
in different subracks. On the other hand, each cabinet is equipped with a duplicated
power distribution system, which allows feeding the voltages to units that are backing
each other up through two separate distribution lines.
Likewise, the IPA2800 network elements have a duplicated alarm collection (or
Hardware Management) and clock distribution system organised by means of redun-dant system clock or timing buffer unit in each subrack and separate, redundant cables
for the alarm collection and clock distribution buses. The synchronisation reference can
be fed to each IPA2800 network element from up to five inputs, three from line interfaces
and two from external sources.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 20/122
20 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c824
Confidential
IPA2800 System Architecture
RNC FU
Redundancy prin-
ciple
Plug-In unit
variant choices
for RNC196 or
RNC450
Plug-In unit
variant choices
for RNC2600
RSMU 2N 2 * CCP1D-A
or
2 * CCP10
or
2 * CCP18-A
or
2 * CCP18-C
2 * CCP1D-A
or
2 * CCP18-A
or
2 * CCP18-C
MXU 2N 2 * MX622-B
or
2 * MX662-C
or
2 * MX622-D
as same subrack
WO-SP pair
2 * MX1G6-A
OMU 2N 2 * CCP1D-A
or
2 * CCP10
or
2 * CCP18-A
2 * CCP1D-A
or
2* CCP18-A
SFU 2N 2 * SF10
or
2 * SF10E
2 * SF20H
TBU 2N 2 * TSS3 or 2 *
TSS3-A
in subracks 1-2 and
2 * TBUF
in other subracks
2 * TSS3 or 2 *
TSS3-A
in subracks 1-2 and
2 * TBUFin other
subracks
WDU / OMU 2N Mixed use of
WDW18, WDW18-
S, WDW36 ,WDW73, WDW147
or HDS14-A
HDS14-A
or WDW147
ICSU N+1 Mixed use of
CCP1D-A, CCP10,
CCP18-A, and
CCP18-C
Mixed use of
CCP1D-A, CCP18-
A and CCP18-C
A2SU SN+ Mixed use of
AL2S-B and AL2S-
D
N/A
Table 2 Redundancy principles of the functional units in the RNC
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 21/122
DN0938143 21
WCDMA RNC Engineering Description IPA2800 System Architecture
Id:0900d8058083c824
Confidential
DMCU SN+ Mixed use of
CDSP-C and
CDSP-DH
CDSP-DH
GTPU SN+ Mixed use of
CCP10, CCP18-A,
and CCP18-C
N/A
NIP1 No redundancy
(Transport redun-
dancy organised by
call routing).
NI16P1A N/A
NIS1 No redundancy
(Transport redun-dancy organised by
call routing and/or
MSP1+1).
NI4S1-B N/A
NIS1P 2N (Transport
redundancy
organised by
MSP1+1 and call
routing).
2 * NI4S1-B N/A
NPGE No redundancy NP2GE-B NP2GE-B
NPGEP 2N 2 * NP2GE-B 2 * NP2GE-B
NPS1 No redundancy
(Transport redun-
dancy organised by
routing).
NP8S1-B NP8S1-B
NPS1P 2N (Transport
redundancy
organised by
routing and MSP
and/or MSP1+1).
2 * NP8S1-B 2 * NP8S1-B
EHU No redundancy EHAT EHAT
No redundancy MCP18-B MCP18-B
SWU Optional 2N (for
LAN connectivity) 1)
1 * ESA12
or
1-2 * ESA24
1-2 * ESA40-A
or
1-2 * ESA24
1) Equipment database does not recognise ESA24 as a functional unit and
HMS does not supervise it.
RNC FU
Redundancy prin-
ciple
Plug-In unit
variant choices
for RNC196 or
RNC450
Plug-In unit
variant choices
for RNC2600
Table 2 Redundancy principles of the functional units in the RNC (Cont.)
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 22/122
22 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807031ff
Confidential
Mechanical Construction of the IPA2800 Network Ele-ments
4 Mechanical Construction of the IPA2800
Network Elements
The mechanical construction of the IPA2800 network elements is based on M2000mechanics platform, which follows a standard hierarchy:
• Cabinets
• Cooling and power supply equipment
• Subracks
• Plug-in units
• Internal cables
The system is based on IEC/ETSI standards for metric dimensioning, along with EN, UL,
and Telcordia recommendations for advanced features in terms of safety, protection
against interference, stability, and durability. Particular attention has been paid to
thermal resistance.
4.1 Cabinets
The equipment of the IPA2800 network elements is housed in EC216 or IC186/-B equip-
ment cabinets. Each cabinet has space for four subracks, the cabinet-specific power
distribution panels plus the subrack-specific cooling equipment, all of which are installed
at the factory, along with the plug-in units and intracabinet cables.
The RNC features two different equipment cabinets:
• RNC Cabinet A (RNAC)
• RNC Cabinet B (RNBC)
The cabinets are dimensioned according to ETS 300119-2 and IEC 60917-2 standards.
The emphasis of its design is on easy transportability and suitability for installations in
premises with a normal or even lower room height. Due to the simple mechanical struc-
ture with relatively few components, the cabinet is easy to assemble and disassemble
when necessary.
The employment of thin sheet steel technology in its manufacture, along with the use of
aluminium or sheet metal profile as the material for the doors makes the cabinet frame
light in weight. When fully equipped, the weight of a single cabinet is circa:
• EC216: 260 kg
• IC186/-B: 230 kg
The cabinets meet the IEC 60950 and UL 60950 safety requirements, along with the EN
300019-1-3, Class 3.1E environmental requirements. Based on a riveted (EC216) or
welded (IC186/-B) frame structure, the earthquake resistance of the cabinet is in accor-
dance with Telcordia GR-63-CORE Zone 4, and the EMC emission and immunity char-
acteristics comply with the EN 300386 and CFR 47, FCC Part 15 standards,
respectively.
NEBS compliance
NEBS stands for Network Equipment Building System. It is a set of Telcordia (former
Bellcore) Standards, whose purpose is to unify HW requirements and help Telephone
companies to evaluate the suitability of products for use in their networks. Compliance
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 23/122
DN0938143 23
WCDMA RNC Engineering Description Mechanical Construction of the IPA2800 Network Ele-ments
Id:0900d805807031ff
Confidential
to NEBS is usually inquired by RBOC:s (Regional Bell Operator Company) in the USA.
The IPA2800 Network Element Hardware is NEBS Level 3 compliant, covering GR-63-
CORE and GR-1089-CORE in Central Office or equivalent premises, as applicable for
type 2 ports, as specified in GR-1089-CORE.
4.1.1 EC216
Figure 3 EC216 cabinet
The EC216 cabinet consists of the following parts (see figure above):
• Riveted self-supporting cabinet frame made of sheet metal with incorporated
mounting flanges for subrack installation and equipment place for CPD120-A
cabinet power supply units
• Doors manufactured of sheet metal profile (2 pcs)
• Two CPD120-A power distribution units at the top of the cabinet, complete with con-
nectors for redundant incoming and outgoing supply lines plus circuit breakers for the latter
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 24/122
24 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807031ff
Confidential
Mechanical Construction of the IPA2800 Network Ele-ments
• Side cover plates at the ends of the cabinet rows
• Vertical grounding bars
• Adjustable feet for permanent installation
•FTRA-B Fan units
• CAIND-A Network Element Alarm indicator (only in the first cabinet).
• CS216-A cable shelves
CS216-A cable shelves are equipped under the two topmost subracks in the
backside of the RNAC cabinet. CPAL-A, CPSY-A and CPSY-B panels are equipped
below the CS216-A.
The cabinet doors can be easily removed, for example, for the duration of the installa-
tion. They have levers with an active locking mechanism, plus separate locks for
securing the levers to their places.
4.1.2 IC186/-B
Figure 4 IC186-B cabinet
The IC186/-B cabinet consists of the following parts (see figure above):
SideCover Plates
Plug-inunits
Subrack
Adjustment foot
Cable Support
Fan tray +
Cover plate
Doors
DN02179668
CPD80-B CabinetPower distribution
Air Guide
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 25/122
DN0938143 25
WCDMA RNC Engineering Description Mechanical Construction of the IPA2800 Network Ele-ments
Id:0900d805807031ff
Confidential
• Welded, self-supporting cabinet frame made of sheet metal, with incorporated
mounting flanges for subrack installation
• Doors manufactured of aluminium profile (4 pcs)
•
Two CPD80-B power distribution units at the top of the cabinet, complete with con-nectors for redundant incoming and outgoing supply lines plus circuit breakers for
the latter
• Side cover plates at the ends of the cabinet rows
• Grounding flanges between adjacent cabinets (4 pcs)
• Vertical grounding bars (2 pcs)
• Horizontal grounding bars (5 pcs)
• Adjustable feet for permanent installation (4 pcs)
The cabinet doors can be easily removed, for example, for the duration of the installa-
tion. They have levers with an active locking mechanism, plus separate locks for
securing the levers to their places.
4.1.3 Dimensions of Cabinets in Floor Rail on Free-standing Installations
The cabinets can be installed either on floor rails or free-standing. The final installation
height of the cabinets varies somewhat, depending on whether they are installed on rails
or free-standing.
The equipment room must have a height of at least 2300 mm (86.8 in) with EC216 and
1900 mm (74.8 in) with IC186/-B, so that the cabinets can be lifted to upward position
from the horizontal position they are transported in.
The minimum distance between an RNC cabinet and another cabinet row is 700 mm
(27.6 in). If installed to the end of an existing row, the minimum distance between the
end of a cabinet row and the wall is 1000 mm (39.4 in) for working area.
The dimensions of the EC216 cabinet, and the needed space for conducting cables from
the top or bottom of the cabinet are shown in the figure below.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 26/122
26 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807031ff
Confidential
Mechanical Construction of the IPA2800 Network Ele-ments
Figure 5 Dimensions of the EC216
The dimensions of the IC186/-B cabinet and the needed space for conducting cables
from the top or bottom of the cabinet are shown in the figure below.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 27/122
DN0938143 27
WCDMA RNC Engineering Description Mechanical Construction of the IPA2800 Network Ele-ments
Id:0900d805807031ff
Confidential
Figure 6 Dimensions of the IC186-B
For more information on requirements of the equipment room and layout, see sections
Operational environment and Equipment room layout in Installation Site Requirementsfor MGW and RNC .
Dimensions of cabinets in free-standing installation
When installed free-standing, the cabinets stand on adjustable feet. The dimensions of
the cabinet frame adjustment range provided by the feet are shown in the below figure.
600
DN02133818 FRONT
180
100
70
500
50
50
50
50
Primary areafor routing cables
Secondary areafor routing cables
Secondary areafor routing cables
IC186
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 28/122
28 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807031ff
Confidential
Mechanical Construction of the IPA2800 Network Ele-ments
Figure 7 Dimensions of EC216 / IC186-B
Dimensions of cabinets in installation on floor rails
The height of the cabinet rows, when installed on floor rails, is the following:
• EC216: 2060 mm (81.1 in) plus the height of the rail and accessories
• IC186/-B: 1760 mm (69.3 in) plus the height of the rail and accessories
For example, if 75-mm (3 in) high rails are used, the total height of the EC216 cabinets
is 2135 mm (84.1 in).
4.2 Subracks
The RNC uses the following subrack types:EC216:
• SRA3: all subracks
• SRBI-C: all subracks
IC186-B:
• SRA1-B / SRA1-A: subracks 1-2 in RNAC
• SRA2-B / SRA2-A: subracks 3-4 in RNAC and 1-4 in RNBC
• SRBI-B: subracks 3-4 in RNAC and 1-4 in RNBC
RNAC subracks 1 and 2 house nearly all 2N redundant equipment in the network
element. Units which make up a mutually redundant pair are placed in separate sub-
racks, except for upgrades from previously delivered RNCs to RNC196 step 6 and
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 29/122
DN0938143 29
WCDMA RNC Engineering Description Mechanical Construction of the IPA2800 Network Ele-ments
Id:0900d805807031ff
Confidential
RNC196 step 7. Each of the two subracks has an individual configuration, with N+1-
redundant units or those with no redundancy equipped in some of the slots.
RNAC subracks 3 and 4 and all RNBC subracks feature N+1 redundant units or those
with no backup at all, with 2N redundant pairs of MXU units in each subrack as the onlyexceptions. A 2N redundant MXU is located in the same subrack as all tributary units
connected to them are in the same subrack.
The differences between the different subrack types are:
• In comparison to SRA1, SRA2 and SRA3 integrate more of the internal cabling of
the subrack, such as signals from the MXUs to tributary units, into its back interface
unit.
• SRBI-C is equipped behind the SRA3 and SRBI-B is equipped behind the SRA2
subrack to provide modular backplane connections using BIE1T or BIE1C connector
panels.
The subracks are designed according to the ETS 300119-4 standard, with particular
attention paid to durability even under demanding conditions, along with compact
dimensioning for optimal use of cabinet space. Their simple attachment mechanism
makes it easy to demount the subrack and replace it with a new one in case it gets
broken.
The IPA2800 network elements provide full EMC protection on the cabinet level.
All subracks are installed in the cabinets at the factory. The dimensions of the subracks
are (H x W x D):
• 300 x 500 x 300 mm (11.8 x 19.7 x 11.8 in).
Figure 8 SRA1 subrack
4.3 Plug-in Units
The printed circuit boards of the plug-in units are multi-layered and covered with a pro-
tective coating. They enable the use of both soldered and pressfit through-hole compo-
nents, along with surface-mounted ones. The plug-in units are generally connected to
DN99572546
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 30/122
30 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807031ff
Confidential
Mechanical Construction of the IPA2800 Network Ele-ments
the other parts of the system by means of backplane connectors of Hard Metric type,
which are designed in accordance with the IEC 1076-4-101 standard. Some of the con-
nections, however, are made from the front panels, normally by means of standard RJ-
45 connectors.
The plug-in units of the IPA2800 network elements are designed to support hot-swap-
ping. They are equipped with various LED indicators for monitoring the unit's condition;
one indicator found in each unit, for example, shows that the unit is separated from the
system and can be extracted from the subrack.
The printed boards of the plug-in units come in two sizes (H x D):
• 115 x 285 mm (4.5 x 11.2 in; TBUF and TSS3/-A units)
• 265 x 285 mm (10.4 x 11.2 in; all other plug-in units)
The front panels of the units are made of aluminium. They are equipped with inser-
tion/extraction levers, which help to manage the friction encountered at their installation,
caused by the high number of connector pins typically needed for the backplane con-
nections. The levers are a highly appropriate feature, since the force to be overcome for
a single plug-in unit may be as high as 400 N, equal to the weight of 41 kilograms.
Like their printed boards, the front panels of the plug-in units come in two sizes (H x W):
• 145 x 25 mm (5.71 x 0.98 in; TBUF and TSS3/-A units)
• 295 x (n x 25) mm (11.61 x (n x 0.98) in; all other plug-in units)
4.4 Cabling
The cabling of the network element consists of interconnection cables (intermediate
cables) and station cables (outgoing cables) as described below. All connections to the
Switch Fabric, multiplexing units, and the wideband network interfaces are made bymeans of high-frequency (HF) cables. Elsewhere in the system, the type of the cables
used has been determined on the basis of the requirements of the associated hardware,
following standard practices in the industry.
Interconnection cables
The interconnection cables comprise all cables running inside and between the cabinets
which form a single network element. The interconnection cables are cut to length and
equipped with connectors. They comprise the following cables:
• Power supply cables
• ATM connection cables
• Hardware Management Bus cables• Synchronisation and timing cables
• SCSI cables between storage devices and their master units
• LAN/Ethernet cables
Site cables
The site (outgoing) cables are all the cables which leave the network element. They
include:
• Trunk circuit cables from the network interfaces
• Power supply cables
• Grounding cables
• I/O cables
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 31/122
DN0938143 31
WCDMA RNC Engineering Description Mechanical Construction of the IPA2800 Network Ele-ments
Id:0900d805807031ff
Confidential
• TCP/IP cables
The site cables connect directly to the plug-in units, to back interface units located at the
rear side of the IC186/-B cabinets or to units in the cabling cabinet.
4.4.1 General Cabling Principles
The general cabling principles for the IPA2800 network elements are as follows:
• The interconnection cables between plug-in units in the same subrack (intrasubrack
cables) are delivered completely installed in the cabinets.
• The interconnection cables between different subracks in the same cabinet or
between the equipment cabinet and the cabling cabinet (intracabinet cables) run
directly from subrack to subrack/cabling cabinet. These cables are delivered com-
pletely installed in the cabinets, as individual cable sets for each cabinet type.
However, if the cabling cabinet is delivered separately, also the intracabinet cables
for it are delivered in separate boxes.• The interconnection cables running between different cabinets (intercabinet cables)
are led directly from one cabinet to another through the cable path. These cables
are delivered with one end of each cable installed in an appropriate cabinet. The
interconnection cables are delivered as prefabricated cable sets.
• The site cables can be routed to the environment through the opening at the bottom
(raised floor installations) or top plate (normal installation) of the cabinet. These
cables must be installed at the site.
All the cables entering the cabinet(s), except for the DC power feed cables, must have
protective wires which are grounded to the frame of the network element at the connec-
tors in the cabling cabinets.
4.5 Cooling Equipment
Each subrack in the network element is provided with a dedicated fan tray cooling unit,
since forced cooling is needed in the cabinets due to the high thermal density. There are
two fan tray variants:
• FTRA-B in EC216, controlled by PD30
• FTRA in IC186/-B, controlled by PD20
The fan trays have eight separate fans with an aggregate capacity sufficient to ensure
N+1 redundancy (if one of the fans fails, this will not cause any rise in the temperature)
and air deflectors, which help to spread the cool air evenly through the subrack.
The FTRA-B fan trays are controlled by the PD30 power supply plug-in units and the
FTRA fan trays are controlled by the PD20 plug-in units on the basis of messages sent
by OMU. OMU, in turn, is supported by the Hardware Management System, which
collects alarms from FTRA/-Bs and controls the temperature inside each plug-in unit. In
case high temperatures are detected, OMU will automatically instruct the PD30/PD20s
(via the HMS bus) to increase the rotation speed of the fans so that the temperature can
be restored to an appropriate level.
Like the subracks, FTRA/-B fan trays are fixed to the cabinets by attaching them to the
mounting flanges. In case of a severe fault, a fan tray can be hot-swapped without any
need for plug-in unit switch-over procedures. For more information, see Replacing plug-
in units and other hardware units.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 32/122
32 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c828
Confidential
Cabinet and Subrack Descriptions for RNC2600
5 Cabinet and Subrack Descriptions for
RNC2600
5.1 RNC2600 Cabinet Types
The RNC2600 features two different equipment cabinets, RNAC and RNBC, of the type
EC216. The subracks of the cabinets are assigned with numbers starting from 1 at the
top of cabinet and ending to 4 at its bottom.
The RNAC and RNBC cabinets can be configured from left to right or from right to left.
The positions of the cabinets in the two different layout options are shown in the figure
below.
Figure 9 Layout options for the RNC2600
RNC2600 has three configuration steps:
• RNC2600/Step 1
Configuration step 1 of RNC2600 implements the minimum capacity and it consists
of cabinet mechanics for RNAC and a fully equipped RNAC cabinet.
• RNC2600/Step 2
Configuration step 2 of RNC2600 consists of a fully equipped RNAC cabinet andcabinet mechanics for RNBC cabinet; all four subracks for RNBC cabinet, all needed
plug-in unit types for subracks 1 and 2 of RNBC cabinet, and cover plates for
subracks 3 and 4 of RNBC cabinet.
Configuration step 2 of RNC2600 includes no plug-in units for subracks 3 and 4 in
RNBC, not even PD30s or TBUFs. Cover plates fill the front sides of subracks 3 and
4 entirely.
• RNC2600/Step 3
Configuration step 3 of RNC2600 consists of all needed plug-in unit types equipped
at RNAC and RNBC cabinets.
In addition to the RNC2600 configuration steps:
DN0624966
1200mm
RNBCRNAC600mm
Left-to-right configuration
Right-to-left configuration
RNBC RNAC
Front side of the cabinets
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 33/122
DN0938143 33
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC2600
Id:0900d8058083c828
Confidential
• The NISx units with STM-1 interfaces are replaced with NPGE(P) units with IP inter-
face units or NPS1(P) units with SDH STM-1 interfaces.
• Optional second ESA40-A can be ordered separately.
The following figures present the hardware configuration options and configurationsteps for the RNC cabinets.
Figure 10 RNAC cabinet in RNC2600
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 34/122
34 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c828
Confidential
Cabinet and Subrack Descriptions for RNC2600
Figure 11 RNBC cabinet in RNC2600
5.2 Equipment in the Subracks
The configurations of the subracks are shown in the tables below.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 35/122
DN0938143 35
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC2600
Id:0900d8058083c828
Confidential
a) As of RN5.0, the functional unit OMS can be selected between the current integrated
OMS or an external standalone OMS network element. For RN6.0 new deliveries, the
standalone OMS is recommended.
Unit type RNAC configuration step 1 RNBC configu-
ration step 2RNBC configu-
ration step 3
Min.
conf.
Max. conf.
SR 1 SR 2 SR 3 SR 4 SR 1 SR 2 SR 3 SR 4 RNAC RNAC - RNBC
DMCU / CDSP-DH 4 4 5 5 5 5 5 5 18 38
EHU / EHAT — — 1 — — — — — 1 1
ICSU / CCP1D-A 1 2 5 6 6 6 6 6 14 38
MXU / MX1G6-A 2 2 2 2 2 2 2 2 8 16
NPS1P / NP8S1-B 0-1 0-1 0-2 0-2 0-2 0-2 0-2 0-2 0-6 0-14
NPS1 / NP8S1-B 0-1 0-1 0-2 0-2 0-2 0-2 0-2 0-2 0-6 0-14
NPGEP / NP2GE-B 0-2 0-2 0-2 0-2 0-2 0-2 0-2 0-2 0-8 0-16
NPGE / NP2GE-B 0-2 0-2 0-2 0-2 0-2 0-2 0-2 0-2 0-8 0-16
OMU / CCP1D-A 1 1 — — — — — — 2 2
- / PD30 1 1 1 1 1 1 1 1 4 8
RSMU / CCP1D-A 1 1 — — — — — — 2 2
SFU / SF20H 1 1 — — — — — — 2 2
TBU / TSS3/-A 1 1 — — — — — — 2 2
TBU / TBUF 1 1 2 2 2 2 2 2 6 14
HDS-C 1 1 — — — — — — 2 2
WDU / HDS14-A
(OMU)
1 1 — — — — — — 2 2
HDD / HDS14 (OMS)
1)
1 1 — — — — — — 2 2
SWU / ESA40-A 1 0-1 — — — — — — 1-2 1-2
OMS / MCP18-B a) 1 — — — — — — — 1 1
Table 3 Number of units in RNC2600 subracks
Unit type Configuration steps
RNC2600/Step 1 RNC2600/Step 2 RNC2600/Step 3
DMCU / CDSP-DH 18 28 38
EHU / EHAT 1 for all configurations
ICSU / CCP1D-A 14 26 38
MXU / MX1G6-A 8 12 16
NPS1P / NP8S1-B a)/b) 0-6 0-10 0-14
Table 4 Maximum number of units in the RNC2600 for each configuration step
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 36/122
36 DN0938143
WCDMA RNC Engineering Description
Id:0900d8058083c828
Confidential
Cabinet and Subrack Descriptions for RNC2600
a) Units are optional.
b) NPS1 and NPS1P units and NPGE and NPGEP units are mutually exclusive.
For information on the capacities of the alternative configurations, see RNC2600 capacity in Product Description for RNC2600 .
Back interface units at the rear of the cabinets in RNC2600
In RNC2600, the cabling cabinet is not used. Connections are made either from the back
interface units located at the rear side of the cabinets or from the front panels of the plug-
in units. For more information, see section Interfaces to the environment . The back inter-
face units located at the rear side of the cabinet are described below:
• BISFA
Back interface unit SFP type A for SF20H with 24 SFP connectors for cabling to
NPGE(P), NPS1(P) and MXU units. BISFA also contains an RJ-45 connector for
cabling between redundant SFUs.• BISFB
Back interface unit SFP type B for MX1G6-A with 4 SFP connectors for cabling to
SFU.
• BISFB-A
Back interface unit SFP type B for MBMS upgrades to RNC196, IC186/IC186-B
mechanics.
• BISFC
Back interface unit SFP type C for NP2GE-B and NP8S1-B plug-in units. The back
interface unit contains 4 SFP connectors for cabling to SFU and an RJ-45 connector
for ETH service terminal for debugging the NP2GE-B or NP8S1-B.
NPS1 / NP8S1-B a)/b) 0-6 0-10 0-14
NPGEP / NP2GE-B a)/b) 0-8 0-12 0-16
NPGE / NP2GE-B a)/b) 0-8 0-12 0-16
OMU / CCP1D-A 2 for all configurations
- / PD30 4 6 8
RSMU / CCP1D-A 2 for all configurations
SFU / SF20H 2 for all configurations
TBU / TSS3/-A 2 for all configurations
TBU / TBUF 6 10 14
HDS-B 2 for all configurationsWDU / HDS14-A (OMU) 2 for all configurations
HDD / HDS14-A (OMS) 2 for all configurations
SWU / ESA40-A a) 1-2 for all configurations
OMS / MCP18-B 1 for all configurations
Unit type Configuration steps
RNC2600/Step 1 RNC2600/Step 2 RNC2600/Step 3
Table 4 Maximum number of units in the RNC2600 for each configuration step
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 37/122
DN0938143 37
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC2600
Id:0900d8058083c828
Confidential
• BISFD
Back interface unit SFP type D for SF20H with 8 SFP connectors for NPGE(P),
NPS1(P) and MXU units.
5.3 RNC2600 Upgrades and Expansions in RN6.0
5.3.1 Optional Expansions for RNC2600
CCP1D-A and HDS-C upgrade
Faulty CCP18-A/C units can be replaced with CCP1D-A in all configurations.
If CCP18-A OMU or RSMU is replaced by CCP1D-A the redundant unit must also be
replaced with CCP1D-A.
Faulty HDS-B can be replaced with HDS-C in all configurations.
gIf OMU’s CCP18-As are replaced by CCP1D-As, a HSD-C upgrade is mandatory
because CCP1D-A is not compatible with HDS-B.
If HDS-B is replaced by HDS-C then CCP1D-A upgrade is required for CCP18-A OMU
(also for the redundant unit) because HDS-C is not compatible with CCP18-A.
In case of upgrading OMU’s CPU units as CCP1D-A, or HSD-B is repleced with HDS-
C, the integrated OMS should be also upgraded to stand alone OMS.
Control plane capacity upgrade
All CCP18-A/C except for OMU are changed to CCP1D-A.Capacity increasing is con-
trolled by SW license.
HDS-C upgrade
If OMU is upgraded to CCP1D-A then HDS-B has to be replaced by HDS-C as CCP1D-
A is not compatible with HDS-A/B (no support for SCSI interface).
ESA40-A upgrade
Faulty ESA24 can be replaced with ESA40-A.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 38/122
38 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580841887
Confidential
Cabinet and Subrack Descriptions for RNC450
6 Cabinet and Subrack Descriptions for
RNC450
6.1 RNC450 Cabinet Types
The RNC450 features two different equipment cabinets, RNAC and RNBC, of the type
EC216. The subracks of the cabinets are assigned with numbers starting from 1 at the
top of cabinet and ending to 4 at its bottom.
The RNAC and RNBC cabinets can be configured from left to right or from right to left.
The positions of the cabinets in the two different layout options are shown in the figure
below.
Figure 12 Layout options for the RNC450
RNC450 has three configuration steps:
• RNC450 step 1
Configuration step 1 of RNC450 implements the minimum capacity and it consists
of cabinet mechanics for RNAC and a fully equipped RNAC cabinet.
• RNC450 step 2
Configuration step 2 of RNC450 consists of a fully equipped RNAC cabinet andcabinet mechanics for RNBC cabinet; all four subracks for RNBC cabinet, all needed
plug-in unit types for subracks 1 and 2 of RNBC cabinet and cover plates for
subracks 3 and 4 of RNBC cabinet.
Configuration step 2 of RNC450 includes no plug-in units for subracks 3 and 4 in
RNBC, not even PD30s or TBUFs. Cover plates fill the front sides of subracks 3 and
4 entirely.
• RNC450 step 3
Configuration step 3 of RNC450 consists of all needed plug-in unit types equipped
at RNAC and RNBC cabinets.
In addition to the RNC450 configuration steps:
DN0624966
1200mm
RNBCRNAC600mm
Left-to-right configuration
Right-to-left configuration
RNBC RNAC
Front side of the cabinets
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 39/122
DN0938143 39
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC450
Id:0900d80580841887
Confidential
• Two NISx units with STM-1 interfaces are included in the basic configuration of
RNC450 configuration step 1. Additional NISx units can be ordered separately.
NIS1P 10-11 can be configured in RNAC or RNBC.
•
One optional NIP1 unit with E1, T1, JT1 interfaces can be ordered separately.• Optional second ESA24 can be ordered separately.
The following figures present the hardware configuration options and configuration
steps for the RNC cabinets.
Figure 13 RNAC cabinet in RNC450
RNAC
DN70621159 FRONT VIEW
D M C U 5
D C M U 4
I C S U 4
I C S U 5
I C S U 6
D M C U 6
D M C U 7
D M C U 8
M X U 4
P D 3 0
M X U 5
A 2 S U 3
D M C U 9
D M C U 1 0
N I S 1 P 1 0 / N I P 1
0 / N P G E ( P )
0
T B U F
T B U F
D M C U 1 2
D M
C U
1 1
I C S U 7
I C S U 8
I C S U 9
D M C U 1 3
D M C U 1 4
D M C U 1 5
M X U 6
P D 3 0
M X U 7
A 2 S U 4
D M C U 1 6
D M C U 1 7
N I S 1 P
1 1
/ N P G E ( P )
1
G T P U 2
/ I C
S U 2 6
N I S 1 P 1 / N P G E ( P )
7
N I S 1 P 3
G T P U
1 /
I C S U 2 5
S F U 0
E S A 2 4
0 ( S
W U 0 )
I C S U 2 2
R S M U 0
M X U 0
P D 3 0
M X U
1
A 2 S U 0
O M U 0
D M C U 0
D M
C U 1
O M S
I C S U
1
I C S U 0
A 2 S U
1
S F U
1
E S A 2 4
1 ( S
W U 1 )
I C S U
2 3
R S M U
1
M X U 2
P D 3 0
M X U 3
A 2 S U 2
B :
H D D
1 O M S
A :
W D U
1
O M U
O M U
1
D M C U 2
D M C U 3
G T P U 0 /
I C S U 2 4
I C S U 3
I C S U 2
E H U
N I S 1 P
0 / N P G E ( P )
6
N I S 1 P
2
T B U F
T B U F
T B U F
T S S 3
T S S 3
T B U F
B :
H D D
0 O M S
A :
W D U
0
O M U
Configuration
step 1
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 40/122
40 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580841887
Confidential
Cabinet and Subrack Descriptions for RNC450
Figure 14 RNBC cabinet in RNC450
6.2 Equipment in the subracks
The configurations of the subracks are shown in the tables below.
DN70621174
RNBC
FRONT VIEW
T B U F
T B U F
T B U F
T B U F
T B U F
T B U F
T B U F
T B U F
D M C U
2 5
- / N P G
E ( P ) 3
I C S U 1
3
I C S U 1
4
I C S U 1
5
- D M C U
2 6
D M C U
2 7
M X U 1 0
P D 3 0
M X U 1 1
A 2 S U 6
D M C U
2 8
D M C U
2 9
G T P U
4 / I C S U 2 8
G T P U
5 / I C S U 2 9
D M C U
1 8
- / N P G E ( P ) 2
I C S U
1 0
I C S U
1 1
I C S U
1 2
D M C U
1 9
D M C U
2 0
D M C U
2 1
M X U
8
P D 3 0
M X U
9
A 2 S U
5
D M C U
2 2
D M C U
2 3
D M C U
2 4
G T P U
3 / I C S U 2 7
D M C U
3 0
I C S U
1 6
I C S U
1 7
I C S U
1 8
D M C U
3 1
D M C U
3 2
D M C U
3 3
M X U
1 2
P D 3 0
M X U
1 3
A 2 S U
7
D M C U
3 4
D M C U
3 5
D M C U
3 6
G T P U
6 / I C S U 3 0
D M C U
3 7
- / N P G E ( P ) 5
I C S U
1 9
I C S U
2 0
I C S U
2 1
D M C U
3 8
D M C U
3 9
D M C U
4 0
M X U
1 4
P D 3 0
M X U
1 5
A 2 S U
8
D M C U
4 1
D M C U
4 2
D M C U
4 3
G T P U
7 / I C S U 3 1
N I S 1 P 1 0
N I S 1 P 1 1
- / N P G E ( P ) 4
N I S 1 P 6
N I S 1 P 1 0
N I S 1 P 5
N I S 1 P 7
N I S 1 P 4
N I S 1 P 6
Configurationstep 2
Configuration
step 3
Unit type RNAC RNBC Min Max
SR 1 SR 2 SR 3 SR 4 SRs 1–4 conf. conf.
A2SU 2 1 1 1 1 5 9
DMCU 2 2 7 7 5–7 a) 18 44
Table 5 Numbers of units in RNC450 subracks
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 41/122
DN0938143 41
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC450
Id:0900d80580841887
Confidential
EHU — 1 — — — 1 1
GTPU — 1 1 1 1 3 7
ICSU e) 3 3–4 3–4 3–4 3–5 f) 12 32
MXU 2 2 2 2 2 8 16
OMS d) 1 — — — — 1 1
ESA24 1 0–1 — — — 1 2
OMS HDD d) 1 1 — — — 2 2
NIP1 — — 0–1 — — 0 1
NIS1 — — 1–2 1–2 0–2 b) 2 6
NIS1P — — 1–3 c) 1–3 c) 0–2 2 12NPGE(P) — — 1–2 1–2 0–1 2 8
OMU 1 1 — — — 2 2
OMU WDU 1 1 — — — 2 2
PD30 1 1 1 1 1 4 8
RRMU e) 1 1 — — — 2 2
RSMU 1 1 — — — 2 2
SFU 1 1 — — — 2 2
TBUF 1 1 2 2 2 6 14
TSS3 1 1 — — — 2 2
a) In RNBC Sr2, there are 5 DMCU units.
b) 0–2 unprotected NIS1 units in RNBC Sr1 or Sr3. Maximum number of unprotected NIS1 units is 6.
c) NIS1P 10-11 can be configured in RNAC or RNBC.
d) Integrated OMS replaces NEMU as of RN3.0 new deliveries. As of RN5.0, the functional unit OMS can
be selected between the current integrated OMS or an external standalone OMS network element. For
RN5.0 new deliveries, the standalone OMS is recommended.
e) ICSU replaces RRMU in both subracks after RN4.0 software release upgrade.
f) In RNBC Sr2, there are 3–5 ICSU units. In other RNBC subracks, there are 3–4 ICSU units.
Unit type RNAC RNBC Min Max
SR 1 SR 2 SR 3 SR 4 SRs 1–4 conf. conf.
Table 5 Numbers of units in RNC450 subracks (Cont.)
Unit type Configuration steps
RNC450 step 1 RNC450 step 2 RNC450 step 3
A2SU 5 7 9
DMCU 18 30 44
EHU 1 for all configurations
ESA24 2 for all configurations
Table 6 Maximum number of units in the RNC450 for each configuration step
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 42/122
42 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580841887
Confidential
Cabinet and Subrack Descriptions for RNC450
For information on the capacities of the alternative configurations, see RNC450 capacity
in Product Description for RNC450 .
For information on equipping rules for interface units NIS1P, NIS1, and NIP1 in
RNC450, see NIS1P, NIS1, and NIP1 equipping rules in Equipment Lists for RNC450 .
Back interface units at the rear of the RNAC cabinet in RNC450
In RNC450, the cabling cabinet is not used. Connections are made either from the back
interface units located at the rear side of the RNAC cabinet or from the front panels of
the plug-in units. For more information, see Interfaces to the environment in this docu-
ment. The back interface units located at the rear side of the RNAC cabinet are
described below:
• CPSY-A and CPSY-B
Back interface units for synchronisation with 2 pieces of BNC connectors and 3pieces of RJ45 connectors for external synchronisation inputs and outputs in each
GTPU 3 6 8
ICSU b) 10 16 22
MXU 8 12 16
OMS a) 1 for all configurations
OMS Hard disk
HDD a)
2 for all configurations
NIP1 1 for all configurations
NIS1 4 6 6
NIS1P 6 10 12
NPGE(P) 4 6 8
OMU 2 for all configurations
OMU Hard disk
WDU
2 for all configurations
PD30 4 6 8
RRMU b) 2 for all configurations
RSMU 2 for all configurations
SFU 2 for all configurations
TBUF 6 10 14
TSS3 2 for all configurations
a) Integrated OMS replaces NEMU as of RN3.0 new deliveries. As of
RN5.0, the functional unit OMS can be selected between the current inte-
grated OMS or an external standalone OMS network element. For RN5.0
new deliveries, the standalone OMS is recommended.
b) ICSU replaces RRMU in both subracks after RN4.0 software release
upgrade.
Unit type Configuration steps
RNC450 step 1 RNC450 step 2 RNC450 step 3
Table 6 Maximum number of units in the RNC450 for each configuration step
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 43/122
DN0938143 43
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC450
Id:0900d80580841887
Confidential
unit. CPSY-A (for TSS3/-A 0) and CPSY-B (for TSS3/-A 1) are equipped in the same
network element.
• CPAL-A
Back interface unit for alarms with one D25 connector for EXAU-A / EXAU controls,
one D37 connector for general current/voltage outputs, 2 pieces of D37 connectors
for voltage controlled inputs, and one D25 connector for current controlled alarm
inputs.
CPAL-A, CPSY-A and CPSY-B units are equipped below the CS216-A cable
shelves, which are located under the two topmost subracks in the backside of the
RNAC cabinet.
• BIE1T or BIE1C
The rear of the subracks are fitted with SRBI-C, subrack for back interface. If the
optional NIP1 0 is used, BIE1T balanced connector panel or BIE1C coaxial connec-
tor panel is installed in the SRBI-C behind the NIP1 0 installation position in RNAC
subrack 3, slot 15.
6.3 Upgrades and Expansions for RNC450 in RN6.0
6.3.1 Optional Upgrades and Expansions for RNC450
HSPA peak rate upgrade
In HSPA peak rate upgrade peak rate performance is controlled by SW license.
Control plane capacity upgrade
All CCP18-A/C except for OMU are changed to CCP1D-A.Capacity increasing is con-
trolled by SW license.
CCP1D-A and HDS-C upgrade
Faulty CCP18-A/C units can be replaced with CCP1D-A in all configurations.
If CCP18-A OMU or RSMU is replaced by CCP1D-A the redundant unit must also be
replaced with CCP1D-A.
Faulty HDS-B can be replaced with HDS-C in all configurations.
g If OMU’s CCP18-As are replaced by CCP1D-As, a HSD-C upgrade is mandatory
because CCP1D-A is not compatible with HDS-B.
If HDS-B is replaced by HDS-C then CCP1D-A upgrade is required for CCP18-A OMU
(also for the redundant unit) because HDS-C is not compatible with CCP18-A.
HDS-C shall be equipped in subracks 1-2, slot 14. The upgrade to HDS-C also needs
that EHU is moved from subrack 2 slot 15 to subrack 2 slot 13.
In case of upgrading OMU’s CPU units as CCP1D-A, or HSD-B is repleced with HDS-
C, the integrated OMS should be also upgraded to stand alone OMS.
ESA40-A upgrade
Faulty ESA24 can be replaced with ESA40-A.
OMS as stand-alone NE
In RN6.0 the integrated OMS can be optionally removed and substituted by a new
external OMS NE.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 44/122
44 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580841887
Confidential
Cabinet and Subrack Descriptions for RNC450
The OMS functional unit (MCP18-B) and the related two HDD (HD B in HDS-B PIUs)
must be removed. All SCSI connections between the OMS and the HDD, and the LAN
connection between OMS and the Ethernet Switch (ESA12/24/40) must be removed as
well.The stand-alone OMS will then be connected to the RNC through the external L2/L3
site switches or, if this solution is not possible, to ETH2 port of SWU.
6.4 RNC450 Upgrades and Expansions in RN5.0
6.4.1 Mandatory Upgrades for RNC450
Minimum hardware requirement for all configurations in RN5.0: the disk size for Inte-
grated OMS must be at least 147 GB.
Before RN5.0 software upgrade, all AL2S-B plug-in units in A2SU functional units must
be replaced with the plug-in unit variant AL2S-D.
For more information, prerequisites and the instructions, see Hardware Expansion for
RNC450 and Upgrading RNC450 to RNC2600 .
6.4.2 Optional Upgrades and Expansions for RNC450
As of RN5.0, the functional unit OMS can be selected between the current integrated
OMS or an external standalone OMS network element. For RN5.0 new deliveries, the
standalone OMS is recommended.
The upgrades supported in RN4.0 are also supported in RN5.0Full CDSP-DH upgrade (replacing all CDSP-C with CDSP-DH) is supported.
For more information, prerequisites and the instructions, see Hardware Expansion for
RNC450 and Upgrading RNC450 to RNC2600 .
6.5 RNC450 Upgrades and Expansions in RN4.0
6.5.1 Mandatory Upgrades for RNC450
In RN4.0 software release, the RRMU functional unit is removed from configuration and
is configured as ICSU unit. RRMU functions are divided between the RSMU, ICSU, andOMU functional units. The location service feature moves to RSMU.
For more information, prerequisites and the instructions, see Hardware Expansion for
RNC450 and Upgrading RNC450 to RNC2600 .
6.5.2 Optional Upgrades and Expansions for RNC450
• Upgrading RNC450 to RNC2600
This optional upgrade changes an RNC450 hardware configuration to an RNC2600
hardware configuration. As a prerequisite, the RN4.0 software upgrade must have
been installed. This is a major upgrade which should be planned thoroughly in
advance and only performed during a time of low traffic, by experienced site person-
nel and by strict adherence to the prerequisites and upgrade process. Automated
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 45/122
DN0938143 45
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC450
Id:0900d80580841887
Confidential
macros are available to support the upgrade process. Some of the main changes
to functional unit and plug-in unit configuration are
• NIS1(P) / NIP1 functional units are replaced by NPS1(P) functional units, using
new NP8S1-B plug-in units
• All CDSPx plug-in units are replaced by CDSP-DH plug-in units
• All MXU functional units receive the new MX1G6-A plug-in unit
• SF10 and SF10E units are replaced with SF20H units
• GTPU and A2SU units are removed and count of ICSU units increases
• Existing functional units are relocated inside the network element
For more information, prerequisites and the instructions, see Upgrading RNC450 to
RNC2600 .
• SFU upgrade
In SFU upgrade, the SF10 plug-in units are replaced by the SF10E plug-in units in
the RNAC cabinet. The SFU upgrade is prerequisite for IP upgrade. New RNAC
cabinet deliveries in RN4.0 use the SF10E plug-in unit, so they do not require anSFU upgrade.
For more information, see SFU and IP Upgrade.
• IP upgrade
IP upgrade deploys IP over Ethernet (IPoE) transport for the Iu-CS, Iu-PS and Iur
interfaces of an RNC. This is achieved by equipping new NP2GE-B plug-in units into
an RNC cabinet and recreating existing ATM interfaces as Ethernet interfaces. The
NP2GE-B plug-in units can be equipped in a cabinet into slots specified in upgrade
documentation. The SFU upgrade must be completed before starting the IP
upgrade.
For more information, see SFU and IP Upgrade.
• Replacing CDSP-C with CDSP-DH (RAN1266, RAN1258)
CDSP-C plug-in units for DMCU can be replaced with CDSP-DH plug-in units
(RAN1266) in existing installations in the following cases:
• To expand the existing DMCU configuration with new units
• To replace a broken unit
• To enable DMCU for the feature RAN1258: HSDPA 14 Mbps per User (CDSP-
DH is mandatory equipment for RAN1258)
Mixed CDSP-C and CDSP-DH configurations are allowed. However, only specific
CDSP-DH units in the network element can be enabled for the RAN1258 feature.
For more information, see Replacing CDSP-C with CDSP-DH and Enabling HSDPA
Capacity Enhancement in CDSP-DH .
• Full CDSP-DH upgrade (replacing all CDSP-C with CDSP-DH is supported). For
more information, see Replacing CDSP-C with CDSP-DH and Enabling HSDPA
Capacity Enhancement in CDSP-DH .
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 46/122
46 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
7 Cabinet and Subrack Descriptions for
RNC196
7.1 RNC196 Cabinet Types
The RNC196 features two different equipment cabinets, RNAC and RNBC, of the type
IC186-B or IC186. The subracks of the cabinets are assigned with numbers starting from
1 at the top of cabinet and ending to 4 at its bottom.
In RNC196, it is possible to include an optional cabling cabinet CEXT in the RNC con-
figuration. For more information on the cabling cabinet, see section Cabinets in WCDMA
RNC Engineering Description for previous releases.
The RNAC and RNBC cabinets can be configured from left to right or from right to left.
CEXT can be placed on either side of the RNAC and RNBC cabinets, at the end of the
row, but not in between. The positions of the cabinets in different layout options areshown in the figure below.
Figure 15 Layout options for the RNC196 (with optional cabling cabinet)
DN0426042
RNBCCEXT RNAC
CEXTRNACRNBC
RNBCCEXT RNAC
1500mm
RNBC CEXTRNAC600mm
Left-to-right configuration
Right-to-left configuration
Front side of the cabinets
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 47/122
DN0938143 47
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
RNC196 has eight configuration steps. RNC cabinets delivered up to RN2.1 HW level
featured five configuration steps. In RN2.2/RN3.0 two new configuration expansion
steps are introduced for RNC196: configuration step 6 and step 7. In RN5.0, the eighth
configuration expansion step is introduced.
RNC196 configuration step 1 is supported in RN2.2/RN3.0, but is not available for new
deliveries. Configuration expansion steps 2–5 are also available for RNC196 in
RN2.2/RN3.0 level expansion deliveries, with the exception that configuration step 2
does not include the RNBC expansion cabinet. The RNBC expansion cabinet must be
ordered at RN2.1 level.
The following sections present the hardware configuration options and configuration
steps for the RNC196 cabinets.
Notation RNC196 step 5 is used to refer to configuration steps 1–5. Notation RNC196
step 7 is used to refer to both RNC196 step 6 and RNC196 step 7. Notation RNC196
step 8 is used to refer to configuration step 8.
g Note that at RN6.0 level, RNC196 step 5 – step 7 HW upgrade is no longer supported,
nor are the expansions.
7.1.1 RNC196 Step 5
Previously delivered RNC cabinets feature five configuration steps and are configured
as shown in the figures RNAC cabinet - RNC196 step 1 and RNBC cabinet - RNC196
steps 2-5 .
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 48/122
48 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
Figure 16 RNAC cabinet - RNC196 step 1
RNAC
DN70621517
T S S 3
T B U F
T B U F
T S S 3
T B U F
T B U F
S F U 1
N I S 1 ( P
) 1
R R M U
1
R S M U
1
M X U 1
P D 2 0
F D U ( O M U )
H D D 1
( N E M U / O M S )
O M U 1
W D U 1
( O M U )
S F U 0
N I S 1 ( P )
0
R R M U 0
R S M U 0
M X U 0
P D 2 0
E H U
E S A 1 2
/ E
S A 2 4
0
N E M U
H D D 0
( N E M U / O M S )
O M U 0
W D U 0
( O M U )
N I P 1
1
N I P 1
0 /
N P G E ( P )
0
I C S U 0
I C S U 1
I C S U 2
D M C U 0
D M C U 1
D M C U 2
M X U 2
P D 2 0
M X U 3
D M C U 3
D M C U 4
D M C U 5
A 2 S U 1
G T P U 0
/ I C
S U 2 4
N I S 1 ( P )
2
N I P 1
3
N I P 1
2 /
N P G E ( P )
1
I C S U 3
I C S U 4
I C S U 5
D M C U 6
D M C U 7
D M C U 8
M X U 4
P D 2 0
M X U 5
D M C U 9
D M C U 1 0
D M C U 1 1
A 2 S U 2
i I C S U 6
G T P U 1
/ I C
S U 2 5
N I S 1 ( P )
3
Configurationstep 1
A 2 S U 0
O p t i o n
a l
E S A 2 4
1
N I S 1 ( P
) 5
/ N
P G E ( P )
7
N I S 1 ( P
) 7
N I S 1 ( P )
4 /
N P G E ( P )
6
N I S 1 ( P )
6
-
T B U F
T B U F
FRONT VIEW
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 49/122
DN0938143 49
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
Figure 17 RNBC cabinet - RNC196 steps 2-5
7.1.2 RNC196 Step 6 and RNC196 Step 7
The following figures show the maximum configuration after RNC196 configuration
steps 6 and 7 are taken into use. The two configuration steps are presented in the same
figures as the functional unit positions are the same. The two configuration steps differ
in the type of plug-in unit variant used: in RNC196 step 7, the newest variants are
required for all units.
DN70621532
RNBC
FRONT VIEW
N I P 1 7
N I P 1 6
/ N
P G E ( P )
3
I C S U 1 0
I C S U 1 1
I C S U 1 2
D M C U
2 0
D M C U
2 1
D M C U
2 2
M X U 8
P D 2 0
M X U 9
D M C U
2 3
D M C U
2 4
D M C U
2 5
A 2 S U
4
G T P U
3 / I C
S U 2 7
D M C U
2 6
D M C U
2 7
N I P 1
5
N I P 1
4 /
N P G E ( P )
2
I C S U 7
I C S U 8
I C S U 9
D M C U 1 2
D M C U 1 3
D M C U 1 4
M X U 6
P D 2 0
M X U 7
D M C U 1 5
D M C U 1 6
D M C U 1 7
A 2 S U 3
G T P U 2
/ I C
S U 2 6
D M C U 1 8
D M C U 1 9
N I P 1
9
N I P 1
8 /
N P G E ( P )
4
I C S U 1 3
I C S U 1 4
I C S U 1 5
D M C U 2 8
D M C U 2 9
D M C U 3 0
M X U 1 0
P D 2 0
M X U 1 1
D M C U 3 1
D M C U 3 2
D M C U 3 3
A 2 S U 5
G T P U 4
/ I C
S U 2 8
D M C U 3 4
D M C U 3 5
N I P 1
1 1
N I P 1
1 0 /
N P G E ( P )
5
I C S U 1 6
I C S U 1 7
I C S U 1 8
D M C U 3 6
D M C U 3 7
D M C U 3 8
M X U 1 2
P D 2 0
M X U 1 3
D M C U 3 9
D M C U 4 0
D M C U 4 1
A 2 S U 6
G T P U 5
/ I C
S U 2 9
D M C U 4 2
D M C U 4 3
Configurationstep 2
Configurationstep 3
Configurationstep 4
Configurationstep 5
T B U F
T B U F
T B U F
T B U F
T B U F
T B U F
T B U F
T B U F
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 50/122
50 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
Figure 18 RNAC cabinet - RNC196 steps 6 and 7
RNAC
DN70623803
T B U 0
T B U 1
T B U 0
T B U 1
T B U 0
T B U 1
S F U 1
A 2 S U
8
I C S U 2 3
R S M U
1
M X U 1
4
P D 2 0
G T P U
6
E H U
B :
H D D
1 ( O
M S )
A :
W D
U 1
( O M U )
O M U 1
I C S U 2 0
I C S U
2 1
S F U 0
A 2 S U 7
I C S U 2 2
R S M U 0
M X U 0
P D 2 0
M X U 1
E S A 1 2
/ E
S A 2 4
0
O M S
A :
W D U 0
( O M U )
B :
H D D 0
( O M S )
O M U 0
I C S U 6
I C S U 1 9
D M C U 3 4
N I P 1
0 ( O
p t i o n a l )
I C S U 0
I C S U 1
I C S U 2
D M C U 0
D M C U 1
D M C U 2
M X U 2
P D 2 0
M X U 3
D M C U 3
D M C U 4
D M C U 5
A 2 S U 1
G T P U 0
N I S x
2
D M C U 4 2
- I C S U 3
I C S U 4
I C S U 5
D M C U 6
D M C U 7
D M C U 8
M X U 4
P D 2 0
M X U 5
D M C U 9
D M C U 1 0
D M C U 1 1
A 2 S U 2
N I S x
1
G T P U 1
N I S x
3
Configurationstep 1
A 2 S U 0
O p t i o n
a l
E S A 2 4
1
D M C U
2 6
D M C U
2 7
D M C U 1 8
D M C U 1 9
N I S x
0
T B U 0
T B U 1
M X U 1
5
FRONT VIEW
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 51/122
DN0938143 51
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
Figure 19 RNBC cabinet - RNC196 steps 6 and 7
7.1.3 Hardware Upgrade to RNC196 Step 6 and RNC196 Step 7
The deliveries of capacity Step 7 upgrades have ended 30.6.2010. See RNC Technical
Note End of Capacity Step Upgrade Support for RNC196 .
An overview of the configurations for the RNC196 configuration steps 6 and 7 is shown
in the figure and sections below. For more information on the hardware changes and
detailed instructions on how to carry out the configuration step expansion, see
document Hardware upgrades from RNC196 step 5 to steps 6 and 7 .
The configuration steps differ in the requirements for plug-in unit variant level. See the
tables Minimum hardware level for RNC196 step 6 and Minimum hardware level for
DN70623815
RNBC
FRONT VIEW
- - I C S U 1 0
I C S U 1 1
I C S U 1 2
D M C U
2 0
D M C U
2 1
D M C U
2 2
M X U 8
P D 2 0
M X U 9
D M C U
2 3
D M C U
2 4
G T P U
7
A 2 S U
4
G T P U
3
N I S 1 P
5
N I S 1 P
7
D M C U 2 5
- I C S U 7
I C S U 8
I C S U 9
D M C U 1 2
D M C U 1 3
D M C U 1 4
M X U 6
P D 2 0
M X U 7
D M C U 1 5
D M C U 1 6
D M C U 1 7
A 2 S U 3
G T P U 2
N I S 1 P
/ N
I S 1
4
N I S 1 P
/ N
I S 1
6
D M C U 3 5
- I C S U 1 3
I C S U 1 4
I C S U 1 5
D M C U 2 8
D M C U 2 9
D M C U 3 0
M X U 1 0
P D 2 0
M X U 1 1
D M C U 3 1
D M C U 3 2
D M C U 3 3
A 2 S U 5
G T P U 4
N I S 1 P
/ N
I S 1
8
N I S 1 P
/ N
I S 1
1 0
D M C U 4 3
- I C S U 1 6
I C S U 1 7
I C S U 1 8
D M C U 3 6
D M C U 3 7
D M C U 3 8
M X U 1 2
P D 2 0
M X U 1 3
D M C U 3 9
D M C U 4 0
D M C U 4 1
A 2 S U 6
G T P U 5
N I S 1 P
9
N I S 1 P
1 1
Configurationstep 2
Cstep 3
onfiguration
Cstep 4
onfiguration
Cstep 5
onfiguration T B U 0
T B U 1
T B U 0
T B U 1
T B U 0
T B U 1
T B U 0
T B U 1
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 52/122
52 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
RNC196 step 7 for more information. Both of the configuration expansion steps require
cabling and configuration changes to the RNC.
The configuration of the RNC must be at least RNC196 step 5 before the RNC196 con-
figuration step 6 and 7 expansions.
g In the following figure Configuration steps RNC196 steps 6 and 7 with mandatory
hardware changes: in slots which show two functional unit names, the lower one shows
the functional unit equipped in that slot in configuration steps 1–5 and the upper one
shows the functional unit equipped in that same slot after the mandatory hardware
changes have been carried out in the expansion to RNC196 step 6 and 7.
Figure 20 Configuration steps RNC196 step 6 and 7 with mandatory hardware
changes
RNAC RNBC
ConfigurationStep 1
Configuration
step 2
Configurationstep 5
I C S U 3
I C S U 4
I C S U 5
D M C U 6
D M C U 7
D M C U 8
M X U 4
P D 2 0
M X U 5
D M C U 9
D M C U 1 0
T B U
1
T B U
0
N I P 1
3
N I P 1
2
A 2 S U 2
D M C U 1 1
G T P U 1
N I S x
3
I C S U 6
S F U 0
A 2 S U 0
A 2 S U 7
R R M U 0
R S M U 0
M X U 0
P D 2 0
N E M U
H D D 0
( N E M U )
O M U 0
T B U
1
T B
U
0
D M C U
1 8
D M C U
1 9
W D U 0
( O M U )
Configuration
step 4
I C S U 0
I C S U 1
I C S U 2
D M C U 0
D M C U 1
D M C U 2
M X U 2
P D 2 0
M X U 3
D M C U 3
D M C U 4
T B U
1
T B
U
0
N I P 1
1
N I P 1
0
A 2 S U 1
D M C U 5
G T P U 0
N I S x
2
- I C S U 1 3
I C S U 1 4
I C S U 1 5
D M C U 2 8
D M C U 2 9
D M C U 3 0
M X U 1 0
P D 2 0
M X U 1 1
D M C U 3 1
D M C U 3 2
T B U
1
T B U
0
N I P 1
9
N I P 1
8
A 2 S U 5
D M C U 3 3
D M C U 3 4
D M C U 3 5
G T P U 4
Configurationstep 3
S F U 1
N I S x
1
R R M U 1
R S M U 1
M X U 1
P D 2 0
O M U 1
T B U
1
T B U
0
F D U
I C S U 2 0
I C S U 2 1
N I S 1 P
5
N I S 1 P
7
E S A 2 4
1 ( O
p t i o n a l )
H D D 0
( N E M U )
W D U 0
( O M U )
I C S U 1 0
I C S U 1 1
I C S U 1 2
D M C U 2 0
D M C U 2 1
D M C U 2 2
M X U 8
P D 2 0
M X U 9
D M C U 2 3
D M C U 2 4
T B U
1
T B U
0
N I P 1
7
N I P 1
6
A 2 S U 4
D M C U 2 5
D M C U 2 6
D M C U 2 7
G T P U 3
I C S U 7
I C S U 8
I C S U 9
D M C U 1 2
D M C U 1 3
D M C U 1 4
M X U 6
P D 2 0
M X U 7
D M C U 1 5
D M C U 1 6
T B U
1
T B
U
0
N I P 1
5
N I P 1
4
A 2 S U 3
D M C U 1 7
D M C U 1 8
D M C U 1 9
G T P U 2
I C S U 1 6
I C S U 1 7
I C S U 1 8
D M C U 3 6
D M C U 3 7
D M C U 3 8
M X U 1 2
P D 2 0
M X U 1 3
D M C U 3 9
D M C U 4 0
T B U
1
T B U
0
N I P 1
1 1
N I P 1
1 0
A 2 S U 6
D M C U 4 1
D M C U 4 2
D M C U 4 3
G T P U 5
E H U
E S A 1 2
/ E
S A 2 4 0
= unit relocated or removed
= unit added
= unit upgraded to newest variant
Configuration step 6
= unit upgraded to newest variant
Configuration step 7
DN0638349
N I S x
0
N I S x
4
N I S x
6
M X U 1
I C S U 6
W D U 0
( O M U )
I C S U 1
9
A 2 S U 8
D M C U 2 6
D M C U 2 7
M X U 1 4
M X U 1 5
G T P U 6
E H U
W D U 1
( O M U )
D M C U
3 4
O p t i o n a
l
N I S x 0
D M C U 4 2
- N I S x
1
D M C U 4 3
- N I S 1 P
9
N I S 1 P
1 1
D M C U
3 5
- N I S x
8
N I S x
1 0
N I S x 4
N I S x 6
D M C U
2 5
-
- - N I S 1 P
5
N I S 1 P
7
G T P U 7
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 53/122
DN0938143 53
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
RNC196 step 6
RNC196 step 6 can be achieved with the following hardware changes. For detailed infor-
mation on the hardware changes and instructions on how to carry out the expansion,
see document Hardware upgrades from RNC196 step 5 to steps 6 and 7 .
RNC196 step 7
RNC196 step 7 can be achieved with the hardware changes listed below, required in
addition to the hardware changes made for configuration step RNC196 step 6. For
detailed information on the hardware changes and instructions on how to carry out the
expansion, see document Hardware upgrades from RNC196 step 5 to steps 6 and 7 .
Functional unit Minimum HW level Configuration expansion step 6
A2SU AL2S-B Add 2 AL2S-D units
GTPU CCP10 Add 3 CCP18-C/CCP18-A units
ICSU CCP10 Add 2 CCP18-C/CCP18-A units
MXU MX622-D Add 2 MX622-D units
or
Add 2 MX622-D units and upgrade all MX622-
C/-B units to MX622-D
NISx NI4S1-B Add up to 8 new NISx units
OMU CCP18-A Upgrade 2 CCP10 units to CCP18-A
OMU WDU HDD HDS-B Upgrade 2 OMU HDS/-A units to 2 HDS-B units
DMCU CDSP-C Reconfigure existing CDSP-Cs to new loca-
tions
In RN4.0, upgrade CDSP-C units to CDSP-DH
FDU Remove MDS-A (replaced by OMU's USB con-
nection for external USB devices. The USB
memory stick can be used only with CCP18-A.)
NIP1 NI16P1A Remove excessive NIP1 units – 1 unit remains
RRMU In RN4.0, remove and reconfigure as ICSU
units
RSMU CCP10
OMS MCP18-B Integrated OMS replaces NEMU as of RN3.0
As of RN5.0, the functional unit OMS can be
selected between the current integrated OMS
or an external standalone OMS network
element. For RN5.0 new deliveries, the stand-
alone OMS is recommended.
Table 7 Minimum hardware level and configuration expansion for RNC196 step 6
Functional unit Minimum HW level Configuration expansion step 7
A2SU AL2S-D Upgrade remaining 7 AL2S-B units to AL2S-D
Table 8 Minimum hardware level and configuration expansion for RNC196 step 7
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 54/122
54 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
7.2 Equipment in the Subracks
The table below shows the configurations of the subracks for RNC196 step 5, RNC196
step 7 and RNC196 step 8. The RNC196 step 7 covers both RNC196 step 6 and
RNC196 step 7 maximum configurations.
GTPU CCP18-C
CCP18-A
Upgrade remaining 6 CCP10 units to CCP18-
C/CCP18-A
ICSU CCP18-C
CCP18-A
Upgrade remaining 19 CCP10 units to CCP18-
C/CCP18-A
RRMU In RN4.0, removed and reconfigured as ICSU
units
RSMU CCP18-C
CCP18-A
Upgrade 2 CCP10 units to CCP18-C/CCP18-A
MXU MX622-D
DMCU CDSP-C In RN4.0, upgrade CDSP-C units to CDSP-DH
OMU CCP18-A
OMU WDU HDD HDS-B
OMS MCP18-B Integrated OMS replaces NEMU as of RN3.0.
As of RN5.0, the functional unit OMS can be
selected between the current integrated OMS
or an external standalone OMS network
element. For RN5.0 new deliveries, the stand-
alone OMS is recommended.
Functional unit Minimum HW level Configuration expansion step 7
Table 8 Minimum hardware level and configuration expansion for RNC196 step 7
Unit type Conf. RNAC RNBC Min Max
SR 1 SR 2 SR 3 SR 4 SRs 1–4 conf. conf.
A2SU RNC196 step 5 1 — 1 1 1 3 7
RNC196 step 7 2 1 1 1 1 5 9
RNC196 step 8 — — — — — — —
DMCU RNC196 step 5 — — 6 6 8 12 44
RNC196 step 7 2 2 7 7 5–7 a) 18 44
RNC196 step 8 1 1 2 3 11 18 18
EHU RNC196 step 5 1 — — — — 1 1
RNC196 step 7 — 1 — — — 1 1
RNC196 step 8 — 1 — — — 1 1
GTPU RNC196 step 5 — — 1 1 1 2 6
RNC196 step 7 — 1 1 1 1–2 b) 4 8
RNC196 step 8 — — — — — — —
Table 9 Number of units in RNC196 subracks
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 55/122
DN0938143 55
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
ICSU h) RNC196 step 5 1 1 3 4 3 9 21
RNC196 step 7 3 3 3 3 3 12 24
RNC196 step 8 3 4 4 4 17 32 32
MXU RNC196 step 5 1 1 2 2 2 6 14
RNC196 step 7 2 2 2 2 2 8 16
RNC196 step 8 2 2 2 2 8 16 16
OMS f) RNC196 step 5 1 — — — — 1 1
RNC196 step 7 1 — — — — 1 1
RNC196 step 8 0–1 — — — — — 1
OMS HDD e) RNC196 step 5 1 1 — — — 2 2RNC196 step 7 1 1 — — — 2 2
RNC196 step 8 0–1 0–1 — — — — 2
ESA24 c) 1 0–1 — — — 1 2
ESA12 c) 1 — — — — 1 1
NIP1 RNC196 step 5 1 — 0–2 0–2 0–2 — 12
RNC196 step 7 1 — — — — 1 1
RNC196 step 8 — — — — — — —
NIS1 RNC196 step 5 1–3 0–1 0–1 0–1 — 2 6
RNC196 step 7 — — 1–2 1–2 0–2 d) 2 6
RNC196 step 8 — — — — — — —
NIS1P RNC196 step 5 1–3 1–3 0–1 0–1 — 2 8
RNC196 step 7 — — 1–2 1–2 0–2 2 12
RNC196 step 8 — — — — — — —
NPGE(P) RNC196 step 5 0–1 0–1 0–1 0–1 0–1 — 8
RNC196 step 7 — — — — — — —
RNC196 step 8 — — 0–1 0–1 0–6 — 8
NPS1(P) RNC196 step 5 — — — — — — —
RNC196 step 7 — — — — — — —
RNC196 step 8 — — 0–1 0–1 0-4 0 6
OMU 1 1 — — — 2 2
OMU WDU 1 1 — — — 2 2
OMU FDU h) RNC196 step 5 — 1 — — — 1 1
PD20 1 1 1 1 1 4 8
RRMU f) 1 1 — — — 2 2
RSMU 1 1 — — — 2 2
Unit type Conf. RNAC RNBC Min Max
SR 1 SR 2 SR 3 SR 4 SRs 1–4 conf. conf.
Table 9 Number of units in RNC196 subracks (Cont.)
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 56/122
56 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
SFU 1 1 — — — 2 2
TBUF 1 1 2 2 2 6 14
TSS3 1 1 — — — 2 2
a) In RNBC Sr2, there are 5 DMCUs.
b) In RNBC Sr2, there are 2 GTPUs.
c) RNC196 is configured with either ESA24 or ESA12.
d) 0-2 NIS1 units in RNBC Sr1 or Sr3: maximum number of NIS1 units is 6.
e) Integrated OMS replaces NEMU in RN3.0.
As of RN5.0, the functional unit OMS can be selected between the current integrated OMS or an external stand-
alone OMS network element. For RN5.0 new deliveries, the standalone OMS is recommended.
f) ICSU replaces RRMU in both subracks after RN4.0 software release upgrade.
g) In RNBC Sr2, there are 6 DMCUs.
h) RNC196 step 5 only: FDU is removed when adding configuration step RNC196 step 6 and RNC196 step 7.
Unit type Conf. RNAC RNBC Min Max
SR 1 SR 2 SR 3 SR 4 SRs 1–4 conf. conf.
Table 9 Number of units in RNC196 subracks (Cont.)
Unit type Configuration steps
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8
A2SU 3 4 5 6 7 9 9 —
DMCU 12 20 28 36 44 44 44 18
EHU 1 for all configurations
ESA24 2 for all configurations
ESA12 1 for all configurations
GTPU 2 3 4 5 6 8 8 —
ICSU a) 7 10 13 16 19 22 22 32
MXU 6 8 10 12 14 16 16 16
OMS b)
* OMS replaces
NEMU as of RN3.0
1 for all configurations
OMS HDD b) 2 for all configurations
NIP1 4 6 8 10 12 1 1 —
NIS1 6 for all configurations —
NIS1P 8 for all configurations 12 12 —
NPGE(P) 4 5 6 7 8 — — 8
NPS1(P) — — — — — — — 6
OMU 2 for all configurations
OMU WDU 2 for all configurations
Table 10 Maximum number of units in RNC196 for each configuration step
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 57/122
DN0938143 57
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
For information on the capacities of the alternative configurations, see RNC196 capacity
in Product Description for RNC196 .
7.3 Upgrades and Expansions for RNC196 in RN6.0
7.3.1 Optional Upgrades and Expansions for RNC196
HSPA peak rate upgrade
In HSPA peak rate upgrade peak rate performance is controlled by SW license.
Control plane capacity upgrade
All CCP18-A/C except for OMU are changed to CCP1D-A.Capacity increasing is con-
trolled by SW license.
In case of NPGE-only or NPS1-only configuration, RNC196 CS8 can be equipped with
max 4+4 NPGE(P) and max 3+3 NPS1(P).
CCP1D-A and HDS-C upgrade
Faulty CCP18-A/C units can be replaced with CCP1D-A in all configurations.
If CCP18-A OMU or RSMU is replaced by CCP1D-A the redundant unit must also bereplaced with CCP1D-A.
Faulty HDS-B can be replaced with HDS-C in all configurations.
g If OMU’s CCP18-As are replaced by CCP1D-As, a HSD-C upgrade is mandatory
because CCP1D-A is not compatible with HDS-B.
If HDS-B is replaced by HDS-C then CCP1D-A upgrade is required for CCP18-A OMU
(also for the redundant unit) because HDS-C is not compatible with CCP18-A.
In case of upgrading OMU’s CPU units as CCP1D-A, or HSD-B is repleced with HDS-
C, the integrated OMS should be also upgraded to stand alone OMS.
OMU FDU 1 for all configurations — — —
PD20 4 5 6 7 8 8 8 8
RRMU a) 2 for all configurations —
RSMU 2 for all configurations
SFU 2 for all configurations
TBUF 6 8 10 12 14 14 14 14
TSS3 2 for all configurations
a) ICSU replaces RRMU in both subracks after RN4.0 software release upgrade.
b) As of RN5.0, the functional unit OMS can be selected between the current integrated OMS or an external standalone OMS
network element. For RN5.0 new deliveries, the standalone OMS is recommended..
Unit type Configuration steps
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8
Table 10 Maximum number of units in RNC196 for each configuration step (Cont.)
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 58/122
58 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821afb
Confidential
Cabinet and Subrack Descriptions for RNC196
ESA40-A upgrade
Faulty ESA24 can be replaced with ESA40-A.
OMS as stand-alone NE
In RN6.0 the integrated OMS can be optionally removed and substituted by a new
external OMS NE.
The OMS functional unit (MCP18-B) and the related two HDD (HD B in HDS-B PIUs)
must be removed. All SCSI connections between the OMS and the HDD, and the LAN
connection between OMS and the Ethernet Switch (ESA12/24/40) must be removed as
well.The stand-alone OMS will then be connected to the RNC through the external L2/L3
site switches or, if this solution is not possible, to ETH2 port of SWU.
7.4 Upgrades and Expansions for RNC196 in RN5.0
7.4.1 Mandatory Upgrades for RNC196
Only CCP18-A can be used for OMU at RN6.0 level. All CCP10 used as OMU functional
units must be upgraded to CCP18-A. CCP10 can be used in all other functional units
RN196 capacity steps 1-6. Mixed use is allowed in N+1 redundant units, but 2N redun-
dant units must be of the same CPU type.
Minimum hardware requirement for all configurations in RN5.0: the disk size for Inte-
grated OMS must be at least 147 GB.
Before RN5.0 software upgrade, all AL2S-B plug-in units in A2SU functional units mustbe replaced with the plug-in unit variant AL2S-D.
7.4.2 Optional Upgrades for RNC196
As of RN5.0, the functional unit OMS can be selected between the current integrated
OMS or an external standalone OMS network element. For RN5.0 new deliveries, the
standalone OMS is recommended.
RNC196 step 7 to step 8 upgrade is supported. For more informaiton, see Hardware
Expansion for RNC196 .
Full CDSP-DH upgrade (replacing all CDSP-C with CDSP-DH) is supported. For more
information, see Replacing CDSP-C with CDSP-DH and Enabling HSDPA Capacity Enhancement in CDSP-DH .
The upgrades supported in RN4.0 are also supported in RN5.0.
7.5 Upgrades and Expansions for RNC196 in RN4.0
7.5.1 Mandatory Upgrades for RNC196
In RN4.0 software release, the RRMU functional unit is removed from configuration and
is configured as ICSU unit. RRMU functions are divided between the RSMU, ICSU, and
OMU functional units. The location service feature moves to RSMU. For more informai-
ton, see Hardware Expansion for RNC196 .
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 59/122
DN0938143 59
WCDMA RNC Engineering Description Cabinet and Subrack Descriptions for RNC196
Id:0900d80580821afb
Confidential
7.5.2 Optional Upgrades for RNC196
• RRMU to ICSU
When the RRMU functional unit is removed, its CCP10/CCP18-A/CCP18-C plug-in
units are released. They can be configured as ICSU, which means that ICSUcapacity increases by two plug-in units. For more informaiton, see Hardware Expan-
sion for RNC196 .
• SFU upgrade
In SFU upgrade, the SF10 plug-in units are replaced by the SF10E plug-in units in
the RNAC cabinet. The SFU upgrade is prerequisite for IP upgrade.
For more information, see SFU and IP Upgrade.
• IP upgrade
IP upgrade deploys IP over Ethernet (IPoE) transport for the Iu-CS, Iu-PS and Iur
interfaces of an RNC. This is achieved by equipping new NP2GE-B plug-in units into
an RNC cabinet and recreating existing ATM interfaces as Ethernet interfaces. The
NP2GE-B plug-in units can be equipped in a cabinet into slots specified in upgradedocumentation. The SFU upgrade must be completed before starting the IP
upgrade.
For more information, see SFU and IP Upgrade.
• Replacing CDSP-C with CDSP-DH (RAN1266, RAN1258)
CDSP-C plug-in units for DMCU can be replaced with CDSP-DH plug-in units
(RAN1266) in existing installations in the following cases:
• to expand the existing DMCU configuration with new units
• to replace a broken unit
• to enable DMCU for the feature RAN1258: HSDPA 14 Mbps per User (CDSP-
DH is mandatory equipment for RAN1258)
Mixed CDSP-C and CDSP-DH configurations are allowed. However, only specificCDSP-DH units in the network element can be enabled for the RAN1258 feature.
For more information, see Replacing CDSP-C with CDSP-DH and Enabling HSDPA
Capacity Enhancement in CDSP-DH .
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 60/122
60 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
8 Functional Unit Descriptions
8.1 Functional Unit CategoriesThe functional units of the RNC fall into four general categories according to their main
functions:
• Management, control computer and data processing units
• Switching and multiplexing units
• Network element interface units
• Units in the timing, power distribution, and hardware management subsystems
The units in the first three categories make up the hardware system blocks which are
responsible for the main functions of the network element, such as switching, signalling,
and database handling. The units in the last category are mainly blocks in the different
subsystems, which are needed for the operation and maintenance of the networkelement, such as clock signal distribution, power distribution, and Hardware Manage-
ment System. All these subsystems are controlled up to a degree by one of the
computer units of the network element, the Operation and Maintenance Unit (OMU).
Notations
The following notations are used throughout this chapter:
• The index numbers of the plug-in units run from left to right and top to bottom.
• Even though the CCP18-A and CCP10 plug-in units are all equipped with onboard
LAN/Ethernet and SCSI interfaces, these are included in the functional unit interface
lists only when the LAN or SCSI facility is actually used (in OMU unit only).
8.2 Management, Control Computer and Data Processing
Units
The management and control computer units are on the highest level in the computing
hierarchy of the IPA2800 network elements. Their tasks are roughly the following:
• Operation and maintenance, including control of the Hardware Management
System (or alarm system) and activation of appropriate recovery and diagnostics
procedures when a fault occurs
• Switch fabric control and ATM circuit hunting
• Control of some of the signal processing units
• Maintenance of the radio network configuration and recovery
• Monitoring of the MS connections
• Handling of signalling functions and management of the associated protocols
• Interfacing with both local users and the higher-level network management system
The management and control computer unit category comprises the following functional
units:
8.2.1 DMCU, Data and Macro Diversity Combining Unit
Purpose: Although from the technical point of view DMCU is a signal processing
unit, it performs some control plane functions besides its signal pro-cessing tasks. Its tasks are the following:
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 61/122
DN0938143 61
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
• WCDMA L1 functions, including macro diversity combining and
outer loop power control
• RLC-U and RLC-C protocol processing
•
MAC-C and MAC-D protocol processing• PDCP protocol processing
• GTP termination
• encryption
• HSDPA with CDSP-DH
All DSPs and RISC processors of the unit are automatically allocated
within the RNC according to the capacity need.
Redundancy: SN+
Type: Signal processing unit with no sub-units
Plug-in unit: CDSP-DH / CDSP-C
Configurable Dynamic Signal Processing Platform
Interfaces: ATM interface to MXU
Figure 21 DMCU's interfaces - CDSP-DH
DN7088176
LED
SLAVE 3
SLAVE 2
SLAVE 1
MASTER
RS-232 CONNECTORS:
SLAVE 1
MASTER
LAN / ETHERNET:
SLAVE 2
SLAVE 3
BACKPLANE:
-TIMING & SYNC- HMS- POWER SUPPLY- MXU
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 62/122
62 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 22 DMCU's interfaces - CDSP-C
8.2.2 GTPU, Gateway Tunneling Protocol Unit
Purpose: GTPU facilitates RNC connections towards the SGSN by performing
those RNC-specific Iu user plane functions which are related to GTP
protocols. These include:
• Routing based on GTP tunnel ID
• UDP/IP protocol termination
Redundancy: SN+
Type: Computer unit with no sub-units
Plug-in unit: CCP1D-A / CCP18-C / CCP18-A / CCP10
Control Computer, Dual Core with Intel Jasper Forest processor
(CCP1D-A).
Control Computer, Pentium M (CCP18-C / CCP18-A)
Control Computer, Pentium III (CCP10)
Interfaces: ATM interface to MXU
CDSP DN00256144
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 63/122
DN0938143 63
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 23 GTPU’s interfaces - CCP1D-A
SER1
SER2
RST
USB1
USB 2
PCIe2
PC Ie 1
PCI Express Interface, P11
PCI Express Interface, P12
USB 2.0 Interface, P15
USB 2.0 Interface, P16
Bicolor HMS LED
Reset Button
Serial Interface, P13
Serial Interface, P14
DN0953479
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 64/122
64 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 24 GTPU's interfaces - CCP18-C
BACKPLANE:
- HMS- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
DN70391828
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 65/122
DN0938143 65
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 25 GTPU's interfaces - CCP18-A
BACKPLANE:
- HMS- SCSI (TO STORAGE
DEVICES INSUBRACKS)
- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
USB
DN0621415
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 66/122
66 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 26 GTPU's interfaces - CCP10
8.2.3 ICSU, Interface Control and Signalling Unit
Purpose: ICSU handles signalling functions and the associated traffic control
functions, including the following tasks:
• Admission control
• Radio resource management
• Handover control
• Packet scheduling
• Signalling protocols to Iu, Iub, and Iur interfaces, including NBAP,
RNSAP, and RANAP
• Monitoring and recovery of the signalling links
Redundancy: N+1
Type: Computer unit with no sub-units
Plug-in unit: CCP1D-A/ CCP18-C / CCP18-A / CCP10
Control Computer, Dual Core with Intel Jasper Forest processor
(CCP1D-A). At RN6.0 level, only CCP1D-A is used.
Control Computer, Pentium M (CCP18-C / CCP18-A)
Control Computer, Pentium III (CCP10)
CCP10 DN00249775
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU- SCSI (NOT USED)- LAN (NOT USED)
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 67/122
DN0938143 67
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Interfaces: ATM interface to MXU
Figure 27 ICSU’s interfaces - CCP1D-A
SER1
SER2
RST
USB1
USB 2
PCIe2
PC Ie 1
PCI Express Interface, P11
PCI Express Interface, P12
USB 2.0 Interface, P15
USB 2.0 Interface, P16
Bicolor HMS LED
Reset Button
Serial Interface, P13
Serial Interface, P14
DN0953479
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 68/122
68 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 28 ICSU's interfaces - CCP18-C
BACKPLANE:
- HMS- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
DN70391828
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 69/122
DN0938143 69
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 29 ICSU's interfaces - CCP18-A
BACKPLANE:
- HMS- SCSI (TO STORAGE
DEVICES INSUBRACKS)
- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
USB
DN0621415
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 70/122
70 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 30 ICSU's interfaces - CCP10
8.2.4 Integrated OMS, Operation and Maintenance Server and its sub-
units
As of RN5.0, the functional unit OMS can be selected between the current integrated
OMS or an external standalone OMS network element. For RN5.0 new deliveries, the
standalone OMS is recommended.
Purpose: Integrated OMS provides the following facilities:
• Local user interface
• Interface towards the higher level network management system
• O&M functions which are not handled by other computer units of the
RNC
• Post-processing support for measurement and statistics
• Peripheral device control
Integrated OMS is equipped with storage devices for storing measure-
ment and statistical data, and an Ethernet switch with 12 or 24 physical
LAN interfaces for connections to the upper-level network management
system and the site LAN. Both facilities are implemented as separate
plug-in units and described in separate sections which follow this one.Redundancy: None
CCP10 DN00249775
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU- SCSI (NOT USED)- LAN (NOT USED)
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 71/122
DN0938143 71
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Type: Computer unit, with dedicated storage devices and the Ethernet Switch
unit (ESA12/ESA24) as sub-units.
Plug-in unit: MCP18-B
Management Computer, Pentium M 745 (MCP18-B)
MCP18-B Interfaces: Small Computer Systems Interface (SCSI)
LAN/Ethernet to NMS, OMU and Site LAN via ESA24/ESA12
LAN/Ethernet to OMU via ESA24/ESA12
USB *
VDU
*) The USB ports can be used to connect a keyboard, a mouse or a
bootable device to the MCP18-B. USB-PS/2 adapters are not sup-
ported.
Figure 31 Integrated OMS interfaces (MCP18-B)
Integrated OMS storage devices
Purpose: Integrated OMS is equipped with dedicated hard disks, which serve as
a storage for the measurement and statistical data it collects.
Redundancy: 2N (hard disk drive)
Type: Sub-unit to integrated OMS
Plug-in unit: HDS-B
BACKPLANE:
- HMS- SCSI (TO STORAGE
DEVICES IN
SUBRACKS)- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
SVGA
USB
DN05226345
RESET SWITCH
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 72/122
72 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Hard Disk Drive with SCSI Interface
Interfaces: Small Computer System Interface (SCSI)
Figure 32 Integrated OMS storage device interfaces
Configuration and redundancy principles of integrated OMS storage devices
Integrated OMS has a duplicated hard disk unit for storing all crucial measurement and
statistical data. The disks are connected to integrated OMS by means of two SCSIbuses, the connection principles of which are shown in the figure below.
DN00256429
LED
BACKPLANE:
- HMS- POWER
SUPPLY
- SCSI
INTERFACES:
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 73/122
DN0938143 73
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 33 SCSI connection principle for integrated OMS storage devices (MCP18-B)
8.2.5 ESA40-A, Ethernet Switch
At RN6.0 release level, RNC uses the ESA40-A LAN/Ethernet switch.
Purpose: ESA40-A is an Ethernet switch, which provides physical LAN/Ethernet
interfaces for connections between OMU, integrated OMS and the other
units of the network element.
Redundancy: None/2N
Type: Sub-unit to integrated OMS
Plug-in unit: ESA40-A
Ethernet Switch
Capacity/ Performance 236 physical 10/100 Base-T Ethernet interfaces
Interfaces: LAN/Ethernet to OMU, integrated OMS, and site LAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
RNC SUBRACK 1
RNC SUBRACK 2
RNAC
W D U 1
( O M S )
DN0938779
BUS END POINT
W D U 0
( O M S ) OMS
SCSI 1
SCSI 0
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 74/122
74 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 34 ESA40-A’s interfaces
8.2.6 ESA24, Ethernet Switch
RNC can have either ESA24 or ESA12 LAN/Ethernet switch.
Purpose: ESA24 is an Ethernet switch, which provides physical LAN/Ethernet
interfaces for connections between OMU, integrated OMS and the other
units of the network element. The ESA24 upgrade increases LAN
switching capacity. Redundant ESA24 is needed for AGPS feature.
Redundancy: None/2N
Type: Sub-unit to integrated OMS
Plug-in unit: ESA24
Ethernet Switch
Capacity/ Performance 24 physical 10/100 Base-T Ethernet interfaces
Interfaces: LAN/Ethernet to OMU, integrated OMS, and site LAN
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 75/122
DN0938143 75
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 35 ESA24's interfaces
8.2.7 ESA12, Ethernet Switch
RNC can have either ESA24 or ESA12 LAN/Ethernet switch.
Purpose: ESA12 is an Ethernet switch which provides physical LAN/Ethernet
interfaces for connections between OMU, integrated OMS and the other
units of the network element.
Redundancy: None
Type: Sub-unit to integrated OMS
Plug-in unit: ESA12
Ethernet Switch
Capacity/ Performance 12 physical 10/100 Base-T Ethernet interfaces
Interfaces: LAN/Ethernet to OMU, integrated OMS, and site LAN
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 76/122
76 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 36 ESA12's interfaces
8.2.8 OMU, Operation and Maintenance Unit and Its Subunits
Purpose: OMU handles all RNC's crucial upper-level system maintenance func-
tions, such as hardware configuration management, Hardware Man-
agement System (HMS) supervision, and the associated centralised
recovery functions. It also serves as an interface between integrated
OMS and the other units of the network element.
In the event of a fault, OMU automatically activates appropriaterecovery and diagnostics procedures within RNC.
In addition, OMU is responsible for the maintenance of the radio
network configuration. It monitors the status of the network, separates
faulty units from the system if necessary, automatically initiates the
associated recovery procedures, and houses the databases that
contain information on the radio network configuration.
OMU has dedicated storage devices, which house the entire system
software and the event buffer for intermediate storing of alarms, along
with the radio network configuration files.
Redundancy: 2N
Type: Computer unit with a dedicated storage device unit as a sub-unit.
ESA12 DN02179274
INTERFACES:
12 x LAN / ETHERNET
BACKPLANE:
- HMS (NOT USED)- POWER SUPPLY
- TIMING & SYNC(NOT USED)
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 77/122
DN0938143 77
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Plug-in unit: CCP1D-A / CCP18-A / CCP10
Control Computer, Dual Core with Intel Jasper Forest processor
(CCP1D-A). At RN6.0 level, only CCP1D-A is used.
Control Computer, Pentium M (CCP18-A)
Control Computer, Pentium III (CCP10)
Interfaces: ATM virtual channels to MXU
LAN/Ethernet via ESA24/ESA12 to integrated OMS
Duplicated Small Computer Systems Interface (SCSI)
Service Terminal interface
Multiplexer Interface
Duplicated Hardware Management System (HMS) interface
Figure 37 OMU’s interfaces - CCP1D-A
SER1
SER2
RST
USB1
USB 2
PCIe2
PC Ie 1
PCI Express Interface, P11
PCI Express Interface, P12
USB 2.0 Interface, P15
USB 2.0 Interface, P16
Bicolor HMS LED
Reset Button
Serial Interface, P13
Serial Interface, P14
DN0953479
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 78/122
78 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 38 OMU's interfaces - CCP18-A
BACKPLANE:
- HMS- SCSI (TO STORAGE
DEVICES INSUBRACKS)
- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
USB
DN0621415
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 79/122
DN0938143 79
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 39 OMU's interfaces - CCP10
OMU's storage devices
Purpose: OMU has two dedicated hard disk units, which serve as a redundant
storage for the entire system software, the event buffer for intermediate
storing of alarms, and the radio network configuration files.
Backup copies are made onto a USB memory stick that is connected to
the CCP18-A front plate. Only memory sticks can be used.
Redundancy: 2N (HDS-C / HDS-B)
none (MDS-A/B)
Type: Sub-unit to OMU
Plug-in unit: HDS-C Hard Disk Drive SAS, only used with CCP1D-A
HDS-A/-B: Hard Disk Drive with SCSI Interface
MDS-A/-B : Magneto Optical Drive with SCSI Interface
External devices: USB memory stick, one for each OMU (for CCP18-A only)
Interfaces: Small Computer System Interface (SCSI)
Universal Serial BUS (USB, CCP18-A)
DN00249799CCP10
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU- SCSI- LAN
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 80/122
80 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 40 OMU’s storage device interfaces - HDS-C
HDS-C
QSFP connector (PCIe)
MiniSAS connector
LED
HDD tray
LED
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 81/122
DN0938143 81
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 41 OMU's storage devices' interfaces
Configuration and redundancy principle of OMU's storage devices
The two mutually redundant WDUs are connected simultaneously to both OMUs by
means of separate SCSI buses. This ensures that a spare unit is immediately available
for either one of the mutually redundant OMUs, eliminating the need for OMU switchover
in case of a memory unit failure.
The USB stick is an optional external device that is not automatically delivered. Only the
USB memory stick that is connected to the active OMU can be used. For OMU switcho-
ver, two USB memory sticks are needed: one for each OMU.
The connection principle for the memory units is illustrated in the figures below.
DN02179305
HDS /-AMDS /-A
INTERFACES:
BACKPLANE:
- HMS- POWER SUPPLY- SCSI
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 82/122
82 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 42 SAS connection principle for OMU storage devices - CCP1D-A and HDS-C
Figure 43 SCSI connection principle for OMU storage devices - CCP18-A and HDS-B
1
0DN0959185
OMU
WDU
PCIe
SAS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
RNAC SUBRACK 1
RNAC SUBRACK 2
RNAC
DN0640747 BUS END POINT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
SCSI 1
SCSI 0
W D U 0
( O M U )
O M U 0
W D U 1
( O M U )
O M U 1
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 83/122
DN0938143 83
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 44 SCSI connection principle for OMU storage devices - CCP10, HDS-A and
MDS-A
8.2.9 RRMU, Radio Resource Management Unit
Purpose: RRMU performs RNC-wide paging and IPA2800 messaging.
Redundancy: 2N
Type: Computer unit
Plug-in unit: CCP18-C / CCP18-A / CCP18-A / CCP10
Control Computer, Pentium M (CCP18-C/CCP18-A)
Control Computer, Pentium III (CCP10)
Interfaces: ATM interface to MXU
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
RNC SUBRACK 1
RNC SUBRACK 2
RNAC
DN99573042 BUS END POINT
SCSI 0 SCSI 1
W D U 0 ( O M U )
F D U ( O M U
)
O M U 1
W D U 1 ( O M U )
O M U 0
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 84/122
84 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 45 RRMU's interfaces - CCP18-C
BACKPLANE:
- HMS- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
DN70391828
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 85/122
DN0938143 85
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 46 RRMU's interfaces - CCP18-A
BACKPLANE:
- HMS- SCSI (TO STORAGE
DEVICES INSUBRACKS)
- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
USB
DN0621415
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 86/122
86 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 47 RRMU's interfaces - CCP10
8.2.10 RSMU, Resource and Switch Management Unit
Purpose: RSMU controls the switch fabrics in RNC and establishes connections
for calls according to requests from the signalling computer units
(ICSUs). It also handles DSP resource management.
ATM switching management functions comprise:
• Establishment of both internal and external connections via SFU,
including ATM circuit hunting
• Management and control of SFU, A2SU and MXU
• Transmission resource management.
DSP resource management tasks comprise:
• Supervision and management of the DMCU units, including the
necessary software upload procedures
• Allocation of the DSPs and associated computer resources to differ-
ent tasks, such as microdiversity combining and data traffic
• Management of the ATM connections within DMCU
Redundancy: 2N
Type: Computer unit
CCP10 DN00249775
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU- SCSI (NOT USED)- LAN (NOT USED)
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 87/122
DN0938143 87
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Plug-in unit: CCP1D-A / CCP18-C / CCP18-A / CCP10
Control Computer, Dual Core with Intel Jasper Forest processor
(CCP1D-A). At RN6.0 level, only CCP1D-A is used.
Control Computer, Pentium M (CCP18-C/CCP18-A)
Control Computer, Pentium III (CCP10)
Interfaces: ATM interface to MXU
Figure 48 RSMU’s interfaces - CCP1D-A
SER1
SER2
RST
USB1
USB 2
PCIe2
PC Ie 1
PCI Express Interface, P11
PCI Express Interface, P12
USB 2.0 Interface, P15
USB 2.0 Interface, P16
Bicolor HMS LED
Reset Button
Serial Interface, P13
Serial Interface, P14
DN0953479
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 88/122
88 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 49 RSMU's interfaces - CCP18-C
BACKPLANE:
- HMS- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
DN70391828
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 89/122
DN0938143 89
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 50 RSMU's interfaces - CCP18-A
BACKPLANE:
- HMS- SCSI (TO STORAGE
DEVICES INSUBRACKS)
- LAN / ETHERNET- POWER FEED- JTAG/ISP
INTERFACES:
USB
DN0621415
RESET SWITCH
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 90/122
90 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 51 RSMU's interfaces - CCP10
8.3 Switching and Multiplexing Units
Switching and multiplexing in RNC is based on the Asynchronous Transfer Mode (ATM)
technology with full support to the various traffic types used in the network. The units in
this category are the following:
• ATM Switching Fabric Units (SFUs) which are used for switching the calls processed
by the network element
• Multiplexer Units (MXUs), for connecting the low-bit-rate network interface units,along with the computer units and signal processing units (which typically have small
to moderate bandwidth requirements) to the ATM switch fabric
• AAL2 Switching Units (A2SUs), which ensure efficient transport of information with
limited transfer delay for low-to-moderate bit-rate units connected to the main switch
fabric.
In addition, the units in this block provide the ATM interface, which serves as the main
message bus between the units in the network element. Upper-level control functions
for all three units are performed by the RSMU functional unit.
CCP10 DN00249775
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU- SCSI (NOT USED)- LAN (NOT USED)
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 91/122
DN0938143 91
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
MXU's connections within the RNC
The figure below shows how the ATM connections in RNC are allocated to its various
units in RNC450. The SFU switching fabric has 16 ports for connections to the other
units in the network element, with an aggregate capacity of 10Gbit/s (equivalent to64STM-1 lines); each port, in turn, has a capacity of 622 Mbit/s. The connections
through the ports are allocated in the following manner:
RNC2600, RNC450, RNC196 step 6, RNC196 step 7 and RNC196 step 8
• 2–6 (12 redundant) ports are used for the external STM-1 connections provided by
the NIS1, NPGE and NPS1 units.
• Eight ports are used for connections to the low-bit-rate network interface units and
the computer units via the mutually redundant MXU pairs. One MXU pair requires
one port.
The equipment of RNC is organised as groups of units around its MXU pairs, with each
group connecting to a MXU pair of its own. When adding the RNC196 configuration step
6, the MXU 1 is moved to RNAC subrack 1 and a new MXU pair, MXU 14 and MXU 15
are added to RNAC subrack 2. After the configuration step RNC196 step 6 upgrade,
both MXU pairs in RNAC subracks 1–2 serve the subracks they are located in.
The figure below shows the MXU pairs and the devices connecting to each MXU pair in
RNC450. The number of units included in each subrack is given after each unit.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 92/122
92 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 52 ATM connections to SFU - RNC450
8.3.1 A2SU, AAL2 Switching Unit
Purpose: A2SU unit handles the ATM adaptation layer type 2, AAL2, switching.
A2SU is an AAL type 2 CPS minipacket switching unit, which is used in
association with the Multiplexing Unit (MXU) for facilitating connections
between the main Switch Fabric (SFU) and the low-to-moderate bit-rate
units (computer units, signal processing units and low-bit-rate network
interface units).
The function of the A2SU unit is to switch the AAL type 2 CPS minipack-
ets. The AAL 2 minipackets coming into and going out of A2SU are
embedded in ATM cells. Before the switching the AAL 2 minipackets are
removed from the ATM cells, and after the switching they are packed
again into ATM cells.
Redundancy: SN+
OMU
DN01128575
2-12 pcs
SFU
DMCU
0-1 pcs ***
3 pcs
5-7 pcs*
1 pcs
1-2 pcs **
2 pcs A2SU
1 pcs RSMU
1 pcs OMU
1 pcs RRMUMXU
1
DMCU
A2SU
GTPU
ICSU
NIP 1
MXU
3-8
ICSU2 pcs
DMCU2 pcs
NIS 1
5 DMCUs in RNBC Sr2*
2 GTPUs in RNBC Sr2**
*** 1 NIP1 in RNAC Sr3
1 pcs A2SU
1 pcs RSMU
1 pcs
1 pcs RRMUMXU
2
ICSU2 pcs
DMCU2 pcs
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 93/122
DN0938143 93
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Type: Signal processing unit
Plug-in unit: AL2S-D / AL2S-B
AAL type 2 switching unit
Interfaces: ATM interface to MXU
Figure 53 A2SU's interfaces - AL2S-D
DN7088176
LED
SLAVE 3
SLAVE 2
SLAVE 1
MASTER
RS-232 CONNECTORS:
SLAVE 1
MASTER
LAN / ETHERNET:
SLAVE 2
SLAVE 3
BACKPLANE:
-TIMING & SYNC- HMS- POWER SUPPLY- MXU
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 94/122
94 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 54 A2SU's interfaces - AL2S-B
8.3.2 MXU, Multiplexer Unit
Purpose: The MXU units enable connection of the low-to-medium bit-rate signal
processing units and computer units, as well as low-bit-rate network
interface units, to the ATM switch fabric. The task of MXU is to perform
the multiplexing and demultiplexing of ATM cells and perform ATM layer
management and processing functions such as header translation,
UPC/NPC parameter control, OAM functions, traffic management, per-
formance monitoring and collection of performance data.Redundancy: 2N
Type: Multiplexer unit
Plug-in unit: MX1G6-A / MX1G6 / MX622-D / MX622-C / MX622-B
ATM Multiplexer plug-in unit 622 Mbit/s
Capacity: 622 Mbit/s
Interfaces: ATM interfaces to:
• SFU switching block
• SFU unit computer
•Control computer units (including DMCU)
AL2S-B DN00249833
INTERFACES:
BACK PLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 95/122
DN0938143 95
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
• Network interfaces
• A2SU
• Connection between the passive MXU via the active one to OMU
(for OAM purposes)
Figure 55 MXU's interfaces - MX1G6 and MX1G6-A
MX1G6/ MX1G6-ADN70170272
SERVICE TERMINAL
INTERFACES:
BACKPLANE:
- TIMING & SYNC
- HMS
- POWER FEED
- SFU
- TRIBUTARY UNITS
- REDUNDANCY INTERFACE
- BOUNDARY SCAN INTERFACE
LED
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 96/122
96 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 56 MXU's interfaces - MX622
8.3.3 SFU, Switching Fabric Unit
Purpose: SFU serves as the main switch fabric of the network element. It
operates according to a non-blocking connection principle, which
means that a connection can be established any time provided that the
needed input and output capacity is available. SFU supports both point-
to-point and point-to-multipoint connection topologies, as well as differ-
entiated handling of various ATM service categories.Redundancy: 2N
Type: Switching fabric
Plug-in unit: SF20H, SF10E, SF10
ATM Switch Fabric Plug-in Unit 10 Gbit/s
Capacity: 10 Gbit/s
Interfaces: ATM interfaces to:
• NI4S1 network interfaces
• Low-bit-rate network interfaces and control computers (via MXUs)
•
OMU from the unit computer of SFU (for OAM purposes andsoftware uploads, via MXUs)
MX622 DN02179344
SERVICE TERMINAL
INTERFACES:
BACKPLANE:
- TIMING & SYNC
- HMS
- POWER FEED
- SFU
- TRIBUTARY UNITS
- SFU UNIT COMPUTER
- OMU FROM PASSIVE MUXVIATHE ACTIVE ONE
LED
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 97/122
DN0938143 97
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 57 SFU's interfaces - SF20H
ETH
SER
DN70166955 SF20H
LED
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 98/122
98 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 58 SFU's interfaces - SF10E
INTERFACES:
LAN (TESTING ONLY)
SERVICETERMINAL
SFP (SFPIF2G5)
BACKPLANE:
- TIMING & SYNC
- HMS
- POWER SUPPLY
- SWITCH PORT TOTRIBUTARY UNITS
- OMU (FROM UNIT
COMPUTER VIAMXU)
DN70498095
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 99/122
DN0938143 99
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 59 SFU's interfaces - SF10
8.4 Network Interface Units
These units serve as the trunk network interfaces of the network element and execute
physical layer and ATM layer functions, such as policing, statistics, Operation Adminis-
tration Maintenance (OAM), buffer management, and scheduling. The category com-
prises the following units:
• NIP1, Network Interface Unit PDH
• NIS1 / NIS1P, Network Interface Unit STM-1
• NPS1 / NPS1P
• NPGE / NPGEP
One network interface unit contains more than one physical interface. Each interface
can be configured to be used as an Iu, Iub, or Iur interface within the total connection
capacity of the network element.
g To ensure at least partial backup for the power supply to the network interfaces,
SDH/TDM trunk connections from RNC to any direction should be divided between at
least two, preferably even more units, which are located in different subracks.
DN02179356
INTERFACES:
BACKPLANE:
- TIMING & SYNC
- HMS
- POWER SUPPLY
- SWITCH PORT TOTRIBUTARY UNITS
- OMU (FROM UNITCOMPUTER VIAMXU)
SF10
SERVICE TERMINAL
LAN
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 100/122
100 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
8.4.1 NIP1
NIP1 is optional in RNC450, RNC196 step 6 and RNC196 step 7.
Purpose: This ATM network interface unit contains PDH E1/T1/JT1 interfaces
with Inverse Multiplexing for ATM (IMA) function, which allows for
flexible grouping of physical links to logical IMA groups. Normally, the
PDH lines are used for connections between RNC and the BTSs.
Redundancy: None
Type: Interface unit
Plug-in unit: NI16P1A
ATM Network Interface 16 × PDH E1/T1/JT1
Capacity/ performance: Sixteen physical PDH electrical interfaces, each with a band-
width of:
•
2048 kbit/s (E1) or • 1544 kbit/s (T1/JT1)
Interfaces: ATM interface to MXU
Clock reference output to TSS3/-A
Figure 60 NIP1's interfaces
NI16P1A
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- MXU- E1 / T1 / JT1- CLOCK
REFERENCEOUTPUT TO TSS3
SERVICE TERMINAL
LAN(NOT USED)
DN02179492
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 101/122
DN0938143 101
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
8.4.2 NIS1 / NIS1P
Purpose: NIS1 provides SDH STM-1 interfaces and handles bit timing, line
coding, and timing recovery.
Redundancy: NIS1: none (organised by routing and/or MSP 1+1)
NIS1P: 2N
Type: Interface unit
Plug-in unit: NI4S1-B
Network Interface 4 × 155 Mbit/s STM-1
Capacity/ performance: Four physical SDH STM-1 interfaces, with a bandwidth of
155,52 Mbit/s for each
Interfaces: ATM interface to SFU
Clock reference output to TSS3/-A
Figure 61 NIS1's interfaces
8.4.3 NPS1 / NPS1P
Purpose: NPS1(P) provides SDH STM-1/STM-4 interfaces and an RJ45 connec-
tor, and handles multiprotocol packet processing at wire speed and
network connectivity.
NI4S1-B DN02179368
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS- POWER SUPPLY- SFU- CLOCK
REFERENCEOUTPUT TO TSS3
LAN (NOT USED)
STM-1
SERVICE TERMINAL
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 102/122
102 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Note that RN4.0 SW does not support STM-4 interface.
Redundancy: NPS1: none (organised by routing)
NPS1P: 2N (organised by routing and MSP and/or MSP 1+1)
Type: Interface unit
Plug-in unit: NP8S1, NP8S1-B
Network Interface 8 × 155 Mbit/s STM-1 or Network Interface 2 × 622
Mbit/s STM-4; one RJ45 connector
Note that RN4.0 SW does not support STM-4 interface.
Capacity/ performance: Eight optical STM-1/OC-3 interfaces, with a bandwidth of
155,52 Mbit/s each, or two optical STM-4/OC-12 interfaces, 622,08
Mbit/s each
Note that RN4.0 SW does not support STM-4 interface.
Interfaces: Fast Ethernet physical layer interfaceSwitch fabric interface
Timing and synchronization interface
Hardware management system interface
ATM interface to SFU
Figure 62 NPS1(P) interfaces
DN70550849 NP8S1-B, NP8S1-A, NP8S1
1
2
3
4
5
6
7
8
STM-1 /STM-4*
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
Rx
STM-1
SERVICE TERMINAL
INTERFACES:
BACKPLANE:
- TIMING & SYNC- HMS
- POWER SUPPLY
- SFU
- CLOCK REFERENCE
OUTPUT TO TSS3- LAN 1-5
CLASS 1 LASER PRODUCTIEC/EN 60825-1
* STM-4 interface cannot be used
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 103/122
DN0938143 103
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
8.4.4 NPGE / NPGEP
Purpose: NPGE(P) provides Ethernet interfaces and handles multiprotocol
packet processing at wire speed.
Redundancy: NPGE: none
NPGEP: 2N
Type: Interface unit
Plug-in unit: NP2GE, NP2GE-B
2 × Gigabit Ethernet interface 1000Base-LX/T (optical/electrical), 2 ×
Fast Ethernet interface 10/100 Base-T (electrical)
Capacity/ performance: Two 1000Base-LX/T (optical or electrical) Gigabit Ethernet
interfaces and two 10/100 Base-T (electrical) Fast Ethernet interfaces
Interfaces: Fast Ethernet physical layer interface
Switch fabric interface
Timing and synchronization interface
Hardware Management System interface
ATM interface to SFU
Figure 63 NPGE(P) interfaces
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 104/122
104 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
8.5 Timing, Power Distribution and Hardware Management
Subsystems
The timing, power distribution, and Hardware Management Subsystems form the lowest
level in the computing hierarchy of the IPA2800 network elements. Each subsystem is
composed of a redundant master unit and a duplicated data distribution/collection bus.
In each case, the bus actually extends through some lower level units to virtually all of
the network element's plug-in units, which are equipped with dedicated hardware blocks
supporting the core parts of the subsystem.
The clock distribution and Hardware Management subsystems in the network element
use the same two types of plug-in units, namely:
• TSS3/-A, Timing and Synchronization, SDH Stratum 3
• TBUF, Timing Buffer.
The clock system meets Stratum 3 level accuracy requirement, as defined in the
Bellcore TA-NWT-1244 standard.
The power distribution subsystem in the network element uses the following type of
plug-in units:
RNC450 with EC216:
• PD30, Power Distribution Plug-in Unit 30 A*
• CD120-A, Cabinet Power Distributor 120 A
* Note that with PD30, FTRA-B is required.
RNC196 with IC186-B:
• PD20, Power Distribution Plug-in Unit 20 A
•
CDP80-B, Cabinet Power Distributor 80 A
8.5.1 TBU, Timing and Hardware Management Bus Unit
The Timing and Hardware Management Bus Unit (TBU) is responsible for the network
element synchronisation, timing signal distribution and message transfer functions in the
hardware management system. TBU is a duplicated functional unit that consists of two
plug-in units in each subrack as well as a serial bus spanning all plug-in units of the
network element. The two plug-in units, the Timing and Synchronisation, SDH Stratum
3 (TSS3/-A) and Timing Buffer (TBUF) and their functions are described below.
TSS3/-A, Timing and Synchronisation, SDH Stratum 3
gNew clock plug-in unit variant TSS3-A is implemented in RN5.0 based RNC2600 deliv-
eries. However, TSS3-A can be used with RN4.0 software if Bridge HMX1BNGX version
inside the plug-in unit is newer than in RN4.0 release package. Refer to technical note
TS-RNC-HW-066 for more detail.
g Due to 2N redundancy a mixed configuration of TSS3 and TSS3-A is not allowed. The
same variant must be used for both clock units in each RNC.
Purpose: TSS3/-As generate the clock signals necessary for synchronising the
functions of RNC. Normally, TSS3/-A operates in a synchronous mode,
that is, it receives an input timing reference signal from an upper level
of the network and adjusts its local oscillator to the long time mean value
by filtering jitter and wander from the timing signal. It transmits the ref-
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 105/122
DN0938143 105
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
erence to the plug-in units in the same subrack, as well as to the TBUF
units, which distribute the signals to units not directly fed by TSS3/-As.
TSS3/-A has inputs for both synchronisation references from other
network elements via the network interfaces, and for those fromexternal sources (options are 2048 kbit/s, 2048 kHz, 64+8 kHz, 1544
kHz, or 1544 kbit/s (TSS3-A)). TSS3-A input is 5 V tolerant.
If all synchronisation references are lost, TSS3/-A can operate by inde-
pendently generating the synchronisation reference for the units in the
network element.
TSS3/-As are also involved in the functioning of the HMS bus. They
convey HMS messages through the HMS bridge node to the HMS
master node. Each OMU has one master node.
TSS3-A is designed to conform ITU-T G813, G.703 and Bellcore GR-
1244 recommendation.
Redundancy: 2N
Type: Functional unit with TBUF units as sub-units
Plug-in unit: TSS3/-A
Timing and Synchronisation, SDH Stratum 3
Interfaces: Synchronisation reference interfaces:
• Three line inputs (from STM-1 or PDH lines)
• Two external inputs (2048 kbit/s, 2048 kHz, 64+8 kHz, 1544 kHz, or
1544 kbit/s (TSS3-A))
• Eight outputs to cabinet timing buses
• One output to subrack timing bus• One external timing output (2048 kHz, 2048 kbit/s (TSS3-A), 1544
kHz (TSS3-A), or 1544 kbit/s (TSS3-A))
HMS interface
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 106/122
106 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 64 TSS3/-A's interfaces
TBUF, Timing Buffer
Purpose: The TBUF unit is a clock buffer which distributes the synchronisation
signals generated by TSS3/-As to those plug-in units that are not
directly fed by TSS3/-As.
TBUFs are also involved in the functioning of the HMS bus. They
convey HMS messages through the HMS bridge node to the HMS
master node. Each OMU has one master node.
Redundancy: 2N
Type: Functional unit, sub-unit of TSS3/-A
Plug-in unit: TBUF
Timing Buffer
Interfaces: Synchronisation reference interfaces:
• One input from TSS3/-A or another TBUF
• One output to subrack timing bus
• One output to another TBUF
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 107/122
DN0938143 107
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
HMS interface
Figure 65 TBUF's interfaces
Connection principle and redundancy for the timing and synchronisation distri-
bution bus
RNC has two separate timing and synchronisation distribution buses to ensure 2N
redundancy for the internal t iming signal distribution. Each bus has its own system clock
(a TSS3/-A plug-in unit), distribution cabling, and timing buffers (TBUF plug-in units).
The two TSS3/-A units backing up each other are placed in different subracks (subracks1 and 2), each of which is powered by a power supply plug-in unit of its own to ensure
redundancy for the power supply. Each of these subracks is also equipped with a TBUF
plug-in unit, which connects the equipment in the subrack to the other clock distribution
bus. The RNAC subracks 3 and 4 and all RNBC subracks have two separate TBUF
units, which connect to different clock distribution buses by means of cables of their own.
In order to function correctly, the differential buses need terminations in the ends of the
bus by means of a termination cable. Due to the expansion of the network element
through the configuration steps, the end of the bus and similarly the termination point
changes. When a new subrack is taken into use in a configuration step, the cabling must
always be moved to the new subrack.
Duplicated buses need two terminations, which means that four terminators altogether
in each cabinet are required for the HMS and the timing and synchronisation distribution
bus.
In RN6.0 the timing bus topology has been changed to a dual star configuration, shown
below
In this topology, both TSS3-A in subracks 1 and 2 are connected to all TBUFs in the
other subracks.
TBUF DN02179371
INTERFACES:
BACKPLANE:
- ONE CLOCKREFERENCEINPUT FROMTSS3 OR TBUF
- ONE TIMING &SYNC OUTPUTTO SUBRACKTIMING BUS
- ONE TIMING &SYNC OUTPUTTO ANOTHERTBUF
- HMS
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 108/122
108 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 66 Dual Star timing bus cabling principles
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 109/122
DN0938143 109
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 67 Connection principle of the duplicated clock distribution bus
8.5.2 HMS, Hardware Management Subsystem
The Hardware Management Subsystem has three hierarchically organised layers of
equipment. The upmost level in the hierarchy is formed by the Hardware Management
Master Nodes (HMMNs), one in each OMU, which control the whole subsystem. TSS3/-
As and TBUFs in the subracks have separate Hardware Management System Bridge
nodes (HMSBs), which form the next, intermediate level in the hierarchy. As the name
suggests, they serve as bridges which connect HMMNs to the lowest-level blocks in thehierarchy, Hardware Management System Slave Nodes. Implemented as dedicated
RNAC RNBC
HMS BUS 0HMS BUS 1
HMS BUS 0HMS BUS 1
DN70680727
RNBC
SUBRACK1
RNBC
SUBRACK2
RNBC
SUBRACK3
RNBCSUBRACK4
RNAC
SUBRACK1
RNAC
SUBRACK2
RNAC
SUBRACK3
RNAC
SUBRACK4
In RNC2600/Step1 In RNC2600/Step3
BUS STARTING POINT
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 110/122
110 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
hardware blocks in all plug-in units, the latter are independent from the other blocks of
the plug-in unit, for example, in terms of the power supply.
A block diagram which illustrates the HMS subsystem implementation is shown in the
figure below.
Figure 68 Block diagram of the HMS subsystem
Connection principle and redundancy of the HMS bus
RNC has also two mutually redundant hardware management buses, which are imple-
mented by means of the same plug-in units as the timing and synchronisation buses,
TSS3/-As and TBUFs. The routing of the hardware management buses, however,
differs somewhat from that of the timing and synchronisation buses.
The hardware management bus is organised in such a way that TSS3/-As and TBUFs
are on an equal level of the subsystem; both act as parallel HMS bridges which convey
messages to the HMS master node. Each OMU has one master node.
HMSB 1TSS3
PIU
HMSS
PIU
HMSS
PIU
HMSSHMSS
HMMN
OMU 1
BACKPLANE BUS
BACKPLANE BUS
SUBRACK 2
HMSS
HMSB 0TBUF
HMSS
HMSB 1TBUF
PIU
HMSS
PIU
HMSS
PIU
HMSSHMSS
HMMN
OMU 0
BACKPLANE BUS
BACKPLANE BUS
SUBRACK 1
CABINET 1 CABINET 2
HMSS
HMSB 0TSS3
HMSS
HMSB 1TBUF
PIU
HMSS
PIU
HMSS
PIU
HMSS
BACKPLANE BUS
BACKPLANE BUS
SUBRACK 4
HMSS
HMSB 0TBUF
HMSS
HMSB 1TBUF
PIU
HMSS
PIU
HMSS
PIU
HMSS
BACKPLANE BUS
BACKPLANE BUS
SUBRACK 4
HMSS
HMSB 0TBUF
HMSS
HMSB 1TBUF
PIU
HMSS
PIU
HMSS
PIU
HMSS
BACKPLANE BUS
BACKPLANE BUS
SUBRACK 1
HMSS
HMSB 0TBUF
HMSS
TO OTHER RACKS
HMSB = HMS BRIDGEHMSS = HMS SLAVE NODEHMMN = HARDWARE MANAGEMENT MASTER NODE
DN99573245
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 111/122
DN0938143 111
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
In order to function correctly, the differential buses need terminations in the ends of the
bus by means of cabling. Due to the expansion of the network element through the con-
figuration steps, the end of the bus and similarly the termination point changes. When a
new subrack is taken into use in a configuration step, the cabling must always be moved
to the new subrack.
Duplicated buses need two terminations, which means that four terminators altogether
in each cabinet are required for the HMS and the timing and synchronisation distribution
bus.
The connection principle of the HMS buses in the network element is shown in the figure
below.
Figure 69 Connection principle of the duplicated HMS bus
RNAC RNBC
HMS BUS 0
HMS BUS 1
HMS BUS 0
HMS BUS 1
DN70680715
RNBC
SUBRACK1
RNBC
SUBRACK2
RNBC
SUBRACK3
RNBC
SUBRACK4
RNAC
SUBRACK1
RNACSUBRACK2
RNAC
SUBRACK3
RNAC
SUBRACK4
In RNC2600/Step1 In RNC2600/Step3
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 112/122
112 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
8.5.3 Power Distribution Subsystem
The power distribution subsystem in the network element uses the following type of
plug-in units:
EC216:
• PD30, Power Distribution Plug-in Unit 30 A*
• CD120-A, Cabinet Power Distributor 120 A
* Note that with PD30, FTRA-B is required.
IC186-B:
• PD20, Power Distribution Plug-in Unit 20 A
• CDP80-B, Cabinet Power Distributor 80 A
Purpose: The Power Distribution Subsystem distributes the -48V power from therectifiers or batteries to the equipment inside the RNC cabinets. This
subsystem consists of two CPD120-A or CPD80-B / CPD80-A power
distribution panels at the top of each cabinet, one PD30/PD20 power
distribution plug-in unit in each subrack, and the associated cabling.
See Cable Lists for RNC for a visual representation of the power feed
to each subrack.
The PD30/PD20 unit also controls the cooling equipment of its own
subrack on the basis of messages sent by OMU.
Redundancy: Power distribution subsystem is duplicated by providing two indepen-
dent feeding input branches from cabinet level to plug-in unit level.
Type: Power distribution
Plug-in unit: CPD120-A: Cabinet Power Distributor 120 A
and
PD30: Power Distribution Plug-in Unit 30 A
CPD80-B / CPD80-A: Cabinet Power Distributor 80 A
and
PD20: Power Distribution Plug-in Unit 20 A
Interfaces: One input for each of the two CPD120-As or CPD80-B/-As; or one dupli-
cated input from the site power supply to the CPD80
Four outputs to subracks (in CPD120-A/CPD80-B/-A) or four duplicated
outputs to subracks (in CPD80)
Outputs to four groups of plug-in units (in PD30/PD20)
Four duplicated inputs from CPD80 (in PD20)
Fan tray control and alarm interface
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 113/122
DN0938143 113
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 70 PD30/PD20's interfaces
Power distribution principle and redundancy
To ensure 2N redundancy for the power distribution lines, the RNC cabinets are
provided with two independent feeding input branches. In EC216, each feeding branch
connects to a dedicated CPD120-A.
Each CPD120-A unit contains:
•Connectors for one of the two mutually redundant supply lines from the batter-ies/rectifiers. In this way the two independent input branches are kept separate until
the subrack level.
• Connectors for four supply lines to the subracks. Each subrack is supplied by a line
from both CPD120-As, giving 2N redundancy.
• Circuit breakers for the outgoing supply lines, each with 30-A rating
The CPD120-A allows for either grounding the 0V lead from the battery or for a use of a
separate grounding cable to achieve floating battery voltage. From the CPD120-A unit,
the voltage is fed through the subrack-specific PD30 power distribution plug-in units,
which have individual 10-A fuses for each outgoing distribution line, to the other plug-in
units in a likewise manner as to the cabinets, that is, through two mutually redundant
supply lines. The two distribution lines are finally combined in the power converter
DN00256417
LED
FUSES
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 114/122
114 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
blocks of individual plug-in units, which adapt the voltage so that it is appropriate for the
plug-in unit components.
In the IC186-B cabinet, each branch connects to a dedicated CPD80-B / CPD80-A unit,
which contains:• Connectors for one of the two mutually redundant supply lines from the batter-
ies/rectifiers. In this way the two independent input branches are kept separate until
the subrack level.
• Connectors for four supply lines to the subracks. Each subrack is supplied by a line
from both CPD80-B / -As, giving 2N redundancy.
• Circuit breakers for the outgoing supply lines, each with 20-A rating
In the IC186 cabinet both feeding branches connect into the same CPD80 unit, which
contains
• Connectors for the two mutually redundant supply lines from the batteries/rectifiers
•
Connectors for the four duplicated supply lines to the subracks• Circuit breakers for the outgoing supply lines, each with 20-A rating
The CPD80-B/-A /CPD80 power distribution unit allows for either grounding the 0V lead
from the battery or for a use of a separate grounding cable to achieve floating battery
voltage.
From the power distribution unit, the voltage is fed through the subrack-specific PD20
power distribution plug-in units, which have individual 8-A fuses for each outgoing dis-
tribution line, to the other plug-in units in a similar manner as to the cabinets, that is,
through two mutually redundant supply lines. The two distribution lines are finally
combined in the power converter blocks of individual plug-in units. The power converter
blocks adapt the voltage so that it is appropriate for the plug-in unit components.
g Operating voltages must be fed in each cabinet of the network element using two
separate pairs of supply cables.
The general power distribution principle for RNC is shown in the figure below. The
internal DC/DC converter structure of the plug-in units is shown in the second figure.
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 115/122
DN0938143 115
WCDMA RNC Engineering Description Functional Unit Descriptions
Id:0900d80580821b07
Confidential
Figure 71 General power distribution principle for RNC
Power distributionplug-in unit
Main fusesor circuitbreakersin power system
-UB2
Terminal blocksand circuitbreakers
Filter
Protection area of the main fuse
Protection area of the circuitbreaker at the cabinet level
Protection areaof the glass
tube fuseat the
subrack level
DC
UB1
UB2
BOV 0
BOV 1
-UB1
-UB2
SMDfuseson PCB
-UB1
Backplane SubrackCabinet
Glass tubefuses in front
panel
Plug-in unit
Protectionarea of the fuse
at theplug-in unit
level
DC
UB1
UB2
dn02180104
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 116/122
116 DN0938143
WCDMA RNC Engineering Description
Id:0900d80580821b07
Confidential
Functional Unit Descriptions
Figure 72 DC/DC converter structure in a plug-in unit
For information on power consumption, see Installation Site Requirements for MGW and
RNC .
8.6 EHU, External Hardware Alarm Unit
Purpose: The purpose of the External Hardware Alarm Unit is to receive external
alarms and send indications of them as messages via HMS to theexternal alarm handler located in OMU.
Another function of EHU is to drive the optional External Hardware
Alarm panel (EXAU-A / EXAU), the cabinet integrated lamp, and
possible other external equipment.
Redundancy: None
Plug-in unit: EHAT
External Hardware Alarm Terminal
Interfaces: Interfaces include 32 voltage controlled inputs, 8 current controlled
inputs, 16 general purpose 20 mA current outputs. Connections to
external devices via CPSAL/-B back interface unit located at the rear of the RNAC cabinet or CPAL back interface unit in the cabling cabinet.
Location: One unit per network element, in RNAC subrack 1.
EXAU-A / EXAU, External hardware alarm unit
The optional peripheral EXAU-A / EXAU provides a visual alarm of the fault indications
of RNC. The EXAU-A / EXAU unit is located in the equipment room.
CAIND/-A, Cabinet alarm indicator
The CAIND/-A is located on top of the RNAC cabinet and provides a visual alarm indi-
cating the network element with a fault.
INPUTCIRCUIT
ENABLE=
=
ON/OFF
ENABLE=
=
ON/OFF
ALARM
CIRCUIT
UO 1
UO 2
GND
GND
B 0V
B 0V
UB 1
UB 2
POWER CONTROL FROM HMS NODE
ALARM TO HMS NODE
DC/DC CONVERTER STRUCTUREIN A PLUG-IN UNIT
dn02179535
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 117/122
DN0938143 117
WCDMA RNC Engineering Description Interfaces to the Environment
Id:0900d805807292ab
Confidential
9 Interfaces to the EnvironmentRNC has the following interfaces to the network it is used in:
•Power supply and grounding interfaces
• PDH/TDM trunk circuit interfaces (E1/T1/JT1)
• SDH/TDM trunk circuit interfaces (STM-1/OC-3)
• External synchronisation and HW alarm interfaces
• Ethernet/LAN interfaces to integrated OMS. As of RN5.0, the functional unit OMS
can be selected between the current integrated OMS or an external standalone
OMS network element. For RN5.0 new deliveries, the standalone OMS is recom-
mended.
• Interfaces for peripheral devices (keyboard, mouse, VDU, printer, external storage
device)
• Service terminal interfaces
There are two locations for making the connections:
• Rear side of the cabinet (the back interface units)
• Front side of the cabinet (front panels of the plug-in units)
These connections are briefly described in the following sections. For more information,
see Cabinet Interfaces and External Cables of MGW and RNC and Installation Site
Requirements for the MGW and RNC..
g The cables leaving the network element are not included in the network element deliv-
ery.
9.1 Power Supply and Grounding InterfacesThe interfaces for the power supply and grounding are located on the back panel of the
CPD120-A / CPD80-B / CPD80-A / CPD80 cabinet power distribution units at the top of
the cabinet. Each cabinet is equipped with two cabinet distribution units. The power
supply cables can be routed from top or bottom of the cabinet regardless of the location
of the unit.
The requirements for the power supply and grounding cables are described in sections
Site power supply and Grounding and bonding of the Installation Site Requirements.
Installation alternatives for the power supply and grounding cables are described in
section Installing the site power supply cables and grounding the network element in
Installing the MGW and RNC .
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 118/122
118 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807292ab
Confidential
Interfaces to the Environment
(A) and (B): the two alternatives for connecting the grounding cable
(2) The CPD120-A is grounded to the cabinet grounding busbar with a grounding
strip.
Figure 73 Power supply interfaces of CPD120-A with DC/I principle
DN05158732
22
DC/I
A
B
-UB2
+UB1
+UB2
-UB1
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 119/122
DN0938143 119
WCDMA RNC Engineering Description Interfaces to the Environment
Id:0900d805807292ab
Confidential
(1): Grounding strip between the +UB terminal connector on the CPD120-A on the
top of the cabinet and the horizontal grounding busbar of the cabinet
(2): The CPD120-A is grounded to the cabinet grounding busbar with a grounding
strip.
Figure 74 Power supply interfaces of CPD120-A with DC/C principle
DN05160839
-UB2
B0V
B0V
-UB1
1 21 2
DC/C
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 120/122
120 DN0938143
WCDMA RNC Engineering Description
Id:0900d805807292ab
Confidential
Interfaces to the Environment
Figure 75 Power supply interfaces of CPD80-B with two connection alternatives and
optional ETS grounding
-UB2
+UB2
+UB1
-UB1
-UB2
+UB2
+UB1
-UB1
+UB2
+UB1
DN02180143
CPD80-B 1
CPD80-B 1
CPD80-B 0
CPD80-B 0
For optionalETS 300 253B0V grounding
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 121/122
DN0938143 121
WCDMA RNC Engineering Description Interfaces to the Environment
Id:0900d805807292ab
Confidential
Figure 76 Power supply interfaces of CPD80-A and their connection alternatives:
DC/I and DC/C principle
9.2 PDH TDM Interfaces
The network element's PDH connections from the NIP1 units are made via BIE1C /
BIE1T connector panels at the rear side of the cabinets. The BIE1C / BIE1T connector
panels are located directly behind the NIP1 units that they serve. It is possible to cable
the back interface units directly into the environment or, alternatively, the cables can be
routed through the cabling cabinet panels.
The numbers of the PDH/TDM lines and the plug-in unit connectors they connect to arelisted in the Cable Lists for RNC .
The PDH and TDM circuit cables are usually cut and connected at the installation site,
but they can also be prepared at the factory. Cables with one connector are usually
prepared at the site.
9.3 SDH TDM Interfaces
The connectors for the STM-1/OC-3 cables are located on the front panels of the NIS1
or NP8S1-B plug-in units. The STM-1/OC-3 connections are routed to the BISFC panel.
The BISFC panel is located at the backside of the RNAC cabinet. The use of the BISFC
panel is optional. It is possible to route the STM-1 cables to the environment directlyfrom the front panels of the NIS1 or NP8S1-B units or from the BISFC panel.
9.4 External Synchronisation Interfaces
The synchronisation interfaces are located on the TSS3/-A plug-in unit. The connections
can be routed through the external synchronisation connector panel CPSY-A (TSS3/-A
0), CPSY-B (TSS3/-A 1), or CPSAL-B / CPSAL depending on the configuration. The
back interface units CPSY-A, CPSY-B and CPSAL-B are located at the rear side of the
RNAC cabinet.
RNC's external synchronisation interfaces support 2.048 Mbit/s and 2.048 MHz connec-
tions.
REAR SIDE
+UB0
-UB0
REAR SIDE
+UB0
-UB0
DN01154291
+UB1
-UB1
+UB1
-UB1
DC/I DC/C
7/16/2019 Dn 0938143
http://slidepdf.com/reader/full/dn-0938143 122/122
WCDMA RNC Engineering DescriptionInterfaces to the Environment
9.5 External HW Alarm Interfaces
The external hardware alarms interfaces are located on the EHAT plug-in unit. The con-
nections can be routed through the alarms connector panel or unit CPAL-A or CPSAL-
B / CPSAL depending on the configuration. The CPAL-A and CPSAL/-B units arelocated at the rear side of the RNAC cabinet. The units also have EXAU-A / EXAU panel
control.
9.6 Ethernet/LAN Interfaces
The external LAN/Ethernet connections are routed directly out of the plug-in unit front
panel connectors.
The connectors for RNC's Ethernet/LAN interfaces to the NetAct, site LAN, and other
destinations, for example, to printers, are placed on both the front panels and back inter-
face units of the ESA24 plug-in unit, whereas ESA12 has connectors only on the front
panel. The connection to OMS is protected by the MCP18-B's firewall.
The ESA24 has 24 LAN interfaces of which 22 are at the backplane connectors and 2
on the front panel (RJ45 connectors). There is also one additional serial port on the front
panel (RJ45 connector). The ESA12 has 12 LAN interfaces, up to nine of which can be
used for connections to the environment.
g A cabinet is configured with either the ESA24 or ESA12.
Although AL2S-D / AL2S-B, CCP18-C / CCP18-A / CCP10, CDSP-DH / CDSP-C,
MX1G6-A / MX1G6, MX622-D / MX622-C / MX622-B, NI4S1-B, and SF10E / SF10 units
include a LAN interface, they are provided for test use only.
9.7 Mouse, Keyboard, VDU, SCSI and Printer Interfaces
The MCP18-B plug-in unit has separate interfaces for a VDU and external storage
devices. It also has four USB ports that can be used to connect a keyboard, mouse or a
bootable device to the MCP18-B. USB-PS/2 adapters are not supported.
The form and pin-out of the SVGA and USB interfaces follow standard industry prac-