diversionsystem - agni controlsbalafire.com/pdf/co2.pdf · textile fire protection system...

15
No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, India Phone: +91- 44-24812420; Fax: +91- 44- 24812475 E-mail: [email protected], [email protected]; Website: www.balafire.com th DIVERSION SYSTEM Fire Detection and Diversion System Introduction :- In Textile Plant, particularly Spinning Industry, normally Blow room is connected with Carding section and Filter section through material duct, dust duct and waste duct. If Spark is created while processing the cotton in Blow Room, which travels through duct and spread to Carding and Filter area. It is always the concept to detect the fire at early stage and confine the fire in one area/ zone and extinguishing the fire within the area / zone. FireDiversion System is basically designed on the above discussed principle. :- 1.) Fire Detection, 2.) Isolating the Fire by stopping themachineries and operating the Dampers, 3.) Diversion Dampers stop thematerial flow and divert thematerial into Diversion Duct, 4.) DivertedMaterials sucked through Suction Fan toQuenching Tank or Fire Collection Bag, 5.) Extinguishing BurningMaterial. 1.) FireAlarm Control Panel. 2.) Electrical Trip Panel. 3.) Pneumatic Control Panel. 4.) Spark Detector. 5.) Heat Detector. 6.) Electronic Hooter. 7.) Fire Stop Damper. 8.) Fire Diversion Damper. 9.) PneumaticActuator. 10.) Quenching Tank. 11.) DiversionDuct&SuctionFan. Fire can be detected either by Spark Detector or Heat Detectors. Fire can be detected by fixing the Heat Detectors of 60 C. Temp. range in the Machinery enclosure and duct. The spark detector is placed in thematerial duct and dust duct which passes through the carding & filter area. SystemOperation The following activities are the key function of the system. System Consists of :- Fire Detection :- ° Page 1 of 4

Upload: lynguyet

Post on 05-Apr-2018

259 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

DIVERSION SYSTEM

Fire Detection and Diversion System

Introduction :-

In Textile Plant, particularly Spinning Industry, normally Blow room is connected withCarding section and Filter section through material duct, dust duct and waste duct.

If Spark is created while processing the cotton in Blow Room, which travels through duct andspread to Carding and Filter area.

It is always the concept to detect the fire at early stage and confine the fire in one area/ zone andextinguishing the fire within the area / zone.

FireDiversion System is basically designed on the above discussed principle.

:-

1.) Fire Detection,2.) Isolating the Fire by stopping themachineries and operating the Dampers,3.) Diversion Dampers stop thematerial flow and divert thematerial into

Diversion Duct,4.) DivertedMaterials sucked through Suction Fan toQuenching Tank or Fire Collection Bag,5.) Extinguishing BurningMaterial.

1.) FireAlarm Control Panel.2.) Electrical Trip Panel.3.) Pneumatic Control Panel.4.) Spark Detector.5.) Heat Detector.6.) Electronic Hooter.7.) Fire Stop Damper.8.) Fire Diversion Damper.9.) PneumaticActuator.10.) Quenching Tank.11.) DiversionDuct&SuctionFan.

Fire can be detected either by Spark Detector or Heat Detectors. Fire can be detected by fixing theHeat Detectors of 60 C. Temp. range in the Machinery enclosure and duct. The spark detector is placed inthematerial duct and dust duct which passes through the carding & filter area.

SystemOperation

The following activities are the key function of the system.

System Consists of :-

Fire Detection :-

°

Page 1 of 4

Page 2: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

Heat Detector is fixed temperature bi-metal type which operates effectively in any type ofenvironmental condition. Spark Detectors are available with higher efficiency to detect the movingspark in the duct. However direct exposure of day light and sun light may create false alarm. Properprecaution has to be adopted while installing the spark detector in the duct. Our Spark DetectorAssemblyconsists of 4 Nos./5 Nos. of Infra Red Spark Detectors fixed at 90°/72° angle to cover entire duct.

In our system we have adopted necessary precaution to avoid false fire alarm and to give the bestefficient detection method.

Fire Alarm Control Panel is the back bone of the entire system which gives input to the detectorand receives the signal from the detectors. It gives audio visual fire indication and also trip machines asper the system requirement and actuates the solenoid to supply the compressed air to the pneumaticactuator to operate Diversion Dampers pneumatically. The Control Panel works with 230 V AC primaryinput supply and 24 V DC secondary battery back up. The entire system works with 24 V DC.

FireAlarmControl Panel

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

DIVERSION SYSTEM

Page 2 of 4

Page 3: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

DIVERSION SYSTEM

Page 3 of 4

FIRE ALARM CUM DIVERSION PANELSPECIFICATION;-

1. Location - Indoor2. Colour - Fire Red3. Painting Process - Powder Coating Process4. Protection Class - IP 525. Description - Fire Alarm cum Pneumatic

Control Panel with Electromagneticrelays for Auxiliary SwitchingContacts. 16 SWG M.S SheetWall Mounting Type.

6. Application - Diversion System7. Power Source - Input Supply Voltage 230V, 1PH,

50 Hz AC Working VoltageDerived will be 24V DC, 10 Amps.

8. Operating Voltage - 24V DC9. Supply Voltage & Source to Detector - 22V DC10. Signal Voltage on Control Panel - 12V DC

SPARK DETECTORSPECIFICATION;-

1. Application - It is designed to fix the Duct to Detect Fire.2. Colour - Fire Red3. Painting Process - Coating Process4. Supply Voltage - 20V DC to 24V DC5. Quicent Current - 5mA6. Alarm Current - 30mA to 100mA7. No. of Sensor - 4 Nos.8. Operating Temp. Range - 0 C to 60 C9. Principle of Detection - IR Detection Technology10. Response Indication - Two Red LED per Module

° °

HEAT DETECTORSPECIFICATION;-

1. Application - It is designed to fix the Duct to Detect Heat.2. Supply Voltage - 18V DC to 24V DC3. Quicent Current - 1.2mA4. Alarm Current - 45mA5. Detector Setting Temp. - 60 C6. Principle of Detection - Bi - Metal Principle7. Response Indication - Two Red LED

°PLAN

IR DETECTOR

FRONT VIEW

Page 4: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

DIVERSION SYSTEM

Page 4 of 4

ELECTRONIC HOOTER WITHFLASHING LAMP

SPECIFICATION;-

1. Mounting Type - Wall Mounting Type.2. Colour - Fire Red3. Painting Process - Powder Coating4. Cable Entry - Bottom5. Working Voltage - 24V DC6. Current Consumption - 100mA Max.7. Type of Tone - Dual Tone

FIRE STOP DAMPERSPECIFICATION;-

1. Damper Material - 3.15mm - 10SWG, H.R Sheet2. Flap Thickness - 4mm Thickness M.S Sheet3. Colour - Fire Red4. Painting Process - Powder Coating5. Actuation - Pneumatic Operation

- Reset from Control Panel

FIRE DIVERSION DAMPERSPECIFICATION;-1. Damper Material - 3.15mm - 10SWG, H.R Sheet2. Flap Thickness - 4mm Thickness M.S Sheet3. Colour - Fire Red4. Painting Process - Powder Coating5. Actuation - Pneumatic Operation

- Reset from Control Panel

QUENCHING TANKSPECIFICATION;-

1. Material - M.S Plate2. Thickness - 5mm Thickness3. Capacity - 1000 Litres / 2000 Litres

Actuator Working Condition(Diversion Duct Open Condition)

Flap Normal Condition(Diversion Duct Closed Condition)

Pneumatic ActuatorReducer

Flap Normal Condition( Duct Open Condition)

Actuator Working Condition( Duct Closed Condition)

Quenching Tank

Front View Side View

Buzzer

Flash Lamp

Page 5: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

CO2 FLOODING SYSTEM

TECHNICAL REVIEW ON STANDARD CO2 FIRE EXTINGUISHING SYSTEM

Page 1 of 3

Introduction

Scope of our offer

System Description

bala-wa CO Flooding Fire Extinguishing system & Components are engineered, designed,manufactured / procured to meet NFPA-12 / IS15528 : 2004 standards.

The scope of this offer is supply of CO2 Fire Protection System for Machineries as per your enquiry.Independent CO2 Cylinder banks are considered for this offer to protect specified area as per thespecification.

High pressure CO2 System is offered. The system consists of the followingmaincomponents.68 Ltrs.W/CSeamless CO2 Cylinder to fill 45Kg CO2 gas.Master & Slave CO2 Cylinder Valves.Discharge & Actuation Hoses.CO2 FrameAssembly with Manifold.CO2 Discharge Nozzles.FireAlarm cum Gas Discharge Panel.ManualGasDischarge Station.Electronic Hooter with Flashing Lamp.Discharge Warning Display Board.

Cylinder bank, consisting of required Nos. of 45 Kg Gas capacity CO2 Cylinders. First cylinder ofCylinder bank will be fitted with 24 V DC Solenoid operated master valve. Remaining cylinders willbe fitted with pneumatically operated slave valves. From the cylinder valves ½” H.P Dischargehoses will be connected to CO Manifold through NRV. Actuation hoses will be connected fromMaster NRV to slave valve. Seamless Sch.80 pipes will be connected from the manifold todischarge nozzles.Required Spark & Heat Detectors along with Manual Gas Discharge Stations, External Hooter, withDischarge Warning Display Board will be provided at the entrance of the each ProtectedArea.Fire Alarm Panel & Gas discharge panel will be provided for interconnecting the Detection signalfrom Detectors and other instruments.

2

2

1.

2.

3.

4.

5.

6.

7.

8.

9.

Page 6: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

CO2 FLOODING SYSTEM

Page 2 of 3

The system can be operated by any one of the followingmethod.

1. Automatic detection and automatic extinguishing.2. Manual detection and Manual discharge through Manual Gas Discharge Stations3. Mechanical Manual discharge by operating manual release lever

On receipt of signal from any : 1. Inbuilt Fire Hooter ON.spark / Heat detector 2. External Hooter ON.

3. Fire Signal will be provided to GasDischarge Panel.

4. Delay Timer ON.5. Tripping signal will be provided.

After the lapse of preset time delay, Gas Discharge Panel will send 24V DC supply to SolenoidValve of master cylinder valve . Solenoid valve will open the master valve and CO will bedischarged to manifold through discharge hose and master NRV.

Further entire gas will be discharged to Protected area discharge nozzle by using distribution pipingfrom the discharge header. Pressure switch, which is fitted on manifold, will be actuated due to theavailability of the pressurized gas in the CO manifold. Simultaneously it will send gas dischargeindication to control panel.

During the actual Fire condition, without waiting for actuation of detectors, Fire signal can beprovided to control panel for discharging the CO2 gas to the protected area, by breaking Glass andpressing both the discharge push button simultaneously. If we press both the push buttonssimultaneously, the same will be treated, as a Fire Signal and the other function will be done asexplained above.

Apart from the above two methods, CO2 cylinder can be opened by pressing the manualreleasing knob of master cylinder valves.

Automatic detection and automatic extinguishing

2

2

Manual detection andManual discharge by through Manual Call Point

Mechanical Manual discharge by operating manual release lever

Page 7: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

No:1, 6 Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai - 600 024, IndiaPhone: +91- 44-24812420; Fax: +91- 44- 24812475

E-mail: [email protected], [email protected]; Website: www.balafire.com

th

CO2 FLOODING SYSTEM

PROTECTION OF BLOW ROOM MACHINERIESWITH

CO2 FLOODING FIRE EXTINGUISHING SYSTEM

Page 3 of 3

Page 8: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

Doc.No.: 093/06-07 3/4Date.: 01/10/2006

Sl.No. Part No.

1 IH147

2 IH040

3 IH042-60

4 IH042-70/80

5 IH148

6 IH148/1

7 IH163/1

8 IH163/2

9 IH163/3

10 IH163/4

11 IH163/6

12 B228S

13 IH140

14 IH141

15 IH039W

16 IH046/Z4/T4

17 IH046/Z6/T6

18 IH046/Z8/T8

19 IH046/Z10/T10

20 IH046/Z*/T*

21 IH171

22 IH172

23 IH173

24 IH174

25 IH227

26 IH175

27 B232

28 B214

29 B215

30 B229

31 B231/*

32 B233

33 B235

34 IH221/1 Pneumatic Panel with one set of actuations, Each set can operate Two Dampers

Conventional Modular Type Fire Alarm Panel with Pneumatic Actuation Module to Operate Dampers (* - As per Requirement)

2x12V DC, *AH SMF Lead Acid Battery

4 zone Conventional Modular Type Fire Alarm Panel with Pneumatic Actuation Module to Operate 4 Dampers

6 zone Conventional Modular Type Fire Alarm Panel with Pneumatic Actuation Module to Operate 6 Dampers

8 zone Conventional Modular Type Fire Alarm Panel with Pneumatic Actuation Module to Operate 8 Dampers

10 zone Conventional Modular Type Fire Alarm Panel with Pneumatic Actuation Module to Operate 10 Dampers

Nylon Hose

Quenching Tank - 1000 Ltrs. Capacity

2Cx1.5 Sq.mm Cu.Armd. FRLS Cable

Fire Stop Dampers with Reducers and Match Rings suitable to fix in 200 - 350mm Dia Ducts

Fire Stop Dampers with Reducers and Match Rings suitable to fix in 400 - 500mm Dia Ducts

Fire Stop Dampers with Reducers and Match Rings suitable to fix in 500 - 600mm Dia Ducts

Pneumatic Actuator suitable for Part.NoIH171, IH172, IH173 & IH174 - Working Pressure of 4 - 10 bar.

Fire Diversion Dampers with Reducers and Match Rings suitable to fix in 200 - 350mm Dia DuctsMetal Diversion Dampers with suitable accessories suitable for 300mm Dia Ducts

4Cx1.5 Sq.mm Cu.Armd. FRLS Cable

Suction Fan

IR Spark Detector Module stand alone unit suitable for Mounting Directly on Duct / Machinery.

TEXTILE FIRE PROTECTION SYSTEM COMPONENTS

Description

Electronic Dual Tone Hooter with Flashing Lamp for Indoor Application.

Probe type heat detector with ordinary junction box - 60 Deg.C Temparature Setting

Probe type heat detector with ordinary junction box - 70 Deg.C / 80 Deg.C Temparature Setting

Fixed Temparature Bi-Metal & Auto Reset type Heat Detector - 60 Deg.C Temparature setting with Dual LED indication suitable for wall or surface mounting type.

Electronic Hooter Dual Tone - For Indoor Application

Fusible Bulb type Link for Fire Proof Door - 68° C Temp. Setting

Manual Call Point - Break Glass Type with canopy & hammer for outdoor application

Fixed Temparature Bi-Metal & Auto Reset type Heat Detector - 60 Deg.C Temparature setting with Dual LED indication suitable for duct mounting type.

IR Spark Detector Assembly suitable for Duct Size upto 400mm Dia

IR Spark Detector Assembly suitable for Duct Size above 400mm Dia upto 600mm Dia

IR Spark Detector Single Module suitable for part No.IH163/1, IH163/2 as spares.

Electrical trip panel with 8 outputs

IR Spark Detector Module - Weather Proof Model

Metal Detector with suitable accessories suitable for 300mm Dia Ducts

Siren Control Panel

Page : 1 of 1Ph No : + 91 44 24812420 Fax : + 91 44 24812475

E-Mail : [email protected]@agnicontrols.com

Page 9: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

SPARK DETECTOR ASSEMBLY

PART NO : IH-163/1

IH163/1 Spark Detector is Designed to use in Duct of

various sizes for Textile Industries or other similar

Industries, where the possibility of Fire Spread through

duct from one area to other. It consist of 4 Spark

Detectors module placed in 90 Deg. Spacing.

The IR Spark Detector individual module has wide

angular sensitivity and can reliably and quickly detect

Amber in motion.

IR Spark Detector is active in the range of 400 nm to 1100

nm.

Each individual module is fully wired and is properly fixed

with suitable filter to avoid damage due to movement of

seed, stone and other hard particles in the duct.

Fully wired Spark Detector Assembly is designed to

connect directly with FireAlarm Control Panel.

1. In Textile Spinning Mills Blow Room Machineries can

be protected by detecting Fire in the duct using Spark

Detector.

2. Carding and Filter Machineries can be protected by

fixing Spark Detector in the duct.

3. Paper and Wood Industries dust duct finds IR Spark

Detector application.

Application:-

IH163/1 Spark Detector is Designed to use in Duct of

various sizes for Textile Industries or other similar

Industries, where the possibility of Fire Spread through

duct from one area to other. It consist of 4 Spark

Detectors module placed in 90 Deg. Spacing.

The IR Spark Detector individual module has wide

angular sensitivity and can reliably and quickly detect

Amber in motion.

IR Spark Detector is active in the range of 400 nm to 1100

nm.

Each individual module is fully wired and is properly fixed

with suitable filter to avoid damage due to movement of

seed, stone and other hard particles in the duct.

Fully wired Spark Detector Assembly is designed to

connect directly with FireAlarm Control Panel.

1. In Textile Spinning Mills Blow Room Machineries can

be protected by detecting Fire in the duct using Spark

Detector.

2. Carding and Filter Machineries can be protected by

fixing Spark Detector in the duct.

3. Paper and Wood Industries dust duct finds IR Spark

Detector application.

Application:-

Maintenance & Inspection :-

Installation Consideration :

To assure maximum sensitivity, keep the surface

of the sensor clean from dirt or other contaminants

at all times.

Periodically test the sensitivity of the detector

using small Amber through specially provided

inspection hole.

IH163/1, must be installed such that no external

light reaches the sensor. External Light source can

cause False FireAlarm.

Maintenance & Inspection :-

Installation Consideration :

To assure maximum sensitivity, keep the surface

of the sensor clean from dirt or other contaminants

at all times.

Periodically test the sensitivity of the detector

using small Amber through specially provided

inspection hole.

IH163/1, must be installed such that no external

light reaches the sensor. External Light source can

cause False FireAlarm.

IH - 163/1 SPARK DETECTORASSEMBLY

IH - 163/1 SPARK DETECTORASSEMBLY

Advantages :

Rigid Model to be used in changing environment.

Fast Responses to Amber/Spark / Flame in moving

Inspection hole is provided to check the Periodically

performance of all the IR Spark Detector modules.

Easy to install and operate

High Speed Response

Free from FalseAlarm

Low Maintenance Cost

Advantages :

Rigid Model to be used in changing environment.

Fast Responses to Amber/Spark / Flame in moving

Inspection hole is provided to check the Periodically

performance of all the IR Spark Detector modules.

Easy to install and operate

High Speed Response

Free from FalseAlarm

Low Maintenance Cost

Page 10: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

Technical Specifications

PARAMETERS RATING UNITS

SUPPLY VOLTAGE 18 - 28 V DC

NO. OF SENSOR UNIT 4 Nos.

SENSOR TYPE IR -

SENSOR RANGE 400 nm TO 1100 nm NANOMETER

MAKE & MODEL SIEMENS ( E 9087)GERMANY / FAIR CHILD -(QSE) USA

QUIESCENT CURRENT < 6 ma

ALARM CURRENT 60 (MAX) ma

FIRE INDICATION RED LED -

MATERIAL MS SHEET 1.6 mm -

CABLE ENTRY ¾ ' -

WIRING 2 WIRE OF MIN1 Sq. mm SIZE -

OPERATING 0° ~ 60° °cTEMPERATURE

FINISHING RED COLOURPOWDER COATING -

<

Technical Specifications

PARAMETERS RATING UNITS

SUPPLY VOLTAGE 18 - 28 V DC

NO. OF SENSOR UNIT 4 Nos.

SENSOR TYPE IR -

SENSOR RANGE 400 nm TO 1100 nm NANOMETER

MAKE & MODEL SIEMENS ( E 9087)GERMANY / FAIR CHILD -(QSE) USA

QUIESCENT CURRENT < 6 ma

ALARM CURRENT 60 (MAX) ma

FIRE INDICATION RED LED -

MATERIAL MS SHEET 1.6 mm -

CABLE ENTRY ¾ ' -

WIRING 2 WIRE OF MIN1 Sq. mm SIZE -

OPERATING 0° ~ 60° °cTEMPERATURE

FINISHING RED COLOURPOWDER COATING -

<

Important :

This document is not intended to be used for installation purposes.Specifications are subject to change without prior notice.

Important :

This document is not intended to be used for installation purposes.Specifications are subject to change without prior notice.

M/s. Agni Controls,No :1, 6th street, Dr.Subbarayan Nagar, Kodambakkam,Chennai - 600024, IndiaPH : +91-44-24812420 FAX : +91-44-24812475Website : www.balafire.comE-mail : [email protected]

M/s. Agni Controls,No :1, 6th street, Dr.Subbarayan Nagar, Kodambakkam,Chennai - 600024, IndiaPH : +91-44-24812420 FAX : +91-44-24812475Website : www.balafire.comE-mail : [email protected]

Page 11: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

CUSTOMER LIST – TEXTILES DIVERSION SYSTEM (WITH TAC APPROVAL)

Sl. No. CUSTOMER PLACE M/c NAME STATUS

01. Century Textiles-Zenith Unit Bombay Trumac Completed

02. Tamil Nadu Jai Bharath Aruppukottai LMW Completed

03. Prime Cotton Textiles Coimbatore Trumac Completed

04. Textool Company Ltd. Coimbatore LMW Completed

05. Century Unit Bombay Trumac Completed

06. Century Yarn Indore Trumac Completed

07. Gem Spineers Madras Trutzschler Completed

08. Sri Jayajothi & Co. Ltd. Rajapalayam LMW Completed

09. Prima Products Pvt. Ltd. Coimbatore Trumac Completed

10. Lakshmi Narashimha Textiles Coimbatore Trumac Completed

11. Kallam Spinning Mills Ltd. Guntur Trumac Completed

12. DCM Clusion Spinning Mills Ltd. New Delhi LMW Completed

13. Patspin India Ltd. Palakkad Trumac Completed

14. Sri Vishnu Shankar Mills Ltd. Rajapalayam LMW Completed

15. Palani Andavar Mills Ltd. Udamalpet LMW Completed

16. Jai Mata Industries Ltd. Rohtak LMW Completed

17. Prime Cotton Textiles Coimbatore Trumac Completed

18. Aruppukottai Shri Vijayalakshmi Aruppukottai LMW Completed

19. Dewan Textiles Ltd. Meerut LMW Completed

20. Malwa Cotton Spinning Mills Ltd. Ludhiana LMW Completed

21. Sudarsanam Spinning Mills Rajapalayam LMW Completed

22. Prakash Cotton Mills Ltd. Bombay Trumac Completed

23. Shreyans Spinning Mills Ludhiana LMW Completed

24. Auro Dyeing Ludhiana LMW Completed

25. Sri Aruppukottai Jayavilas Mills Aruppukottai LMW Completed

26. Auro Spinning Mills Ludhiana LMW Completed

27. Nagreeka Exports Ltd. Bombay LMW Completed

28. Sri Renuga Textiles Mills Ltd. Theni Trumac Completed

29. Pranavaditya Spinning Mills Bombay Trumac Completed

30. Euro Cotspin Ltd. New Delhi Cross Roll Completed

31. Vibha Synthetics Pvt. Ltd. Hinganghat LMW Completed

32. Mehala Carona Textiles Pvt. Ltd. Tirupur LMW Completed

33. Abhishek Industries Ltd. Barnala LMW Completed

34. Nahar Spinning Mills Phase I Mandideep LMW Completed

35. Nahar Spinning Mills Phase II Mandideep LMW Completed

36. Malwa Cotton Spinning Mills Paonta Sahib Trumac Completed

Page 12: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

CUSTOMER LIST – TEXTILES DIVERSION SYSTEM (WITH TAC APPROVAL)

Sl. No. CUSTOMER PLACE M/c NAME STATUS

37. L.G.B. Industries Ltd. Karur Trumac Completed

38. Nahar Exports Ltd. Lairu LMW Completed

39. Raymonds Calltri Denim Ltd. Thane Trutzschler Completed

40. Sailakshmi Industries Pvt. Ltd. Bangalore Rieter Completed

41. Navnitlal Pvt. Ltd. Sarvoli Trutzschler Completed

42. Nahar Fibres Ltd. Ludhiana LMW Completed

43. Rohini Mills Tirupur LMW Completed

44. Hindoostan Spg. & Wvg. Mills Ltd. Mumbai Trumac Completed

45. Pondicherry Co -op. Spg. Mills Ltd. Pondicherry LMW Completed

46. Century Denim Indore Trumac Completed

47. Kamala Mills Ltd. Mumbai Trumac Completed

48. Shree Manufacturing Co. Ltd. Medak LMW Completed

49. R.S.R.Mohota Spg.&Wvg. Mills Ltd. Wani LMW Completed

50. Hindoostan Spg. Mills Ltd. (C Unit) Mumbai Trumac Completed

51. Annpurna Overseas Ltd. Panipet Trumac Completed

52. Mannan Cotton Spg. Mills Abiramam Trumac Completed

53. Mangrul Mills Nagpur LMW Completed

54. Vijayalakshmi Spintex Secunderabad Trumac Completed

55. Sri Jayajothi & Co. Ltd. Rajapalayam LMW Completed

56. Jayalakshmi Textiles Pvt. Ltd. Aruppukottai LMW Completed

57. Sri Nachiammal Cotton Mills Ltd. (B Unit) Chettinad LMW Completed

58. Sri Nachiammal Cotton Mills Ltd. (C Unit) Veeranam LMW Completed

59. Nav Maharashtra Sahakari

Soot Girani Ltd. Kolhapur Trumac Completed

60. Rishab Spg. Mills Ludhiana Trumac Completed

61. Nahar Spg. Mills Ltd. Phase III Mandideep LMW Completed

62. Sri Nachiammal Cotton Mills

Ltd. (A Unit) Chettinad Trumac Completed

63. Indo Count Industries Ltd. Kolhapur Rieter Completed

64. Patspin India Ltd. Palakkad Trumac Completed

65. Abhinav Cotspin Ltd. Batala Trumac Completed

66. Jaya Murugan Cotton Mills Ltd. Salem LMW Completed

67. Cheema Spintex Ltd. Chandigarh Rieter Completed

68. Satia Synthetics Ltd. Muktsar LMW Completed

69. Nahar Spg. Mills Ltd. (Phase II) Mandideep LMW Completed

70. Malkkal Fibres Ltd. Mhow Cross Roll Completed

Page 13: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

CUSTOMER LIST – TEXTILES DIVERSION SYSTEM (WITH TAC APPROVAL)

Sl. No. CUSTOMER PLACE M/c NAME STATUS

71. Pacific Cotspin Ltd. Calcutta LMW Completed

72. R.M. Mohite Textiles Ltd. Kholapur LMW Completed

73. Prathibha Syntex Ltd. Indore Trumac Completed

74. G.T.N. Textiles Ltd. Nagpur Trumac Completed

75. Govardhan Spineers Ltd. Madurai Trumac Completed

76. Sree Nagalakshmi Textiles Ltd. Madurai Trumac Completed

77. Rishab Spinning Mills Ltd. Ludhiana Trumac Completed

78. Nahar Fibres Ltd. Malerkota LMW Completed

79. G.T.N. Textiles Ltd. Alwaye LMW Completed

80. Hindustan Fibres Ltd. Alwar Trumac Completed

81. Priyadarshini Fabs Ltd. Srivilliputhur Trumac Completed

82. Indo Count Choongnam Ind. Ltd. Baroda Trumac Completed

83. Armstrong Spg. Mills Ltd. Tirupur Trumac Completed

84. B.A.P.L. Industries Ltd. Coimbatore Trumac Completed

85. Nahar Spinning Mills Ltd., Mandideep Trumac Completed

86. Raymond Ltd., Yatmal ---- Completed

87. Visakha Industries Ltd., Nagpur (Moudha) Trumac Completed

88. Premier Mills Ltd., Hosur ---- Completed

89. Gem Spinners India Ltd., Chengalpet ---- Completed

90. LGB Textiles Karur ---- Completed

91. Satia Synthetics Mukstar ---- Completed

92. Nagreekara Exports Ltd., Kolhapur ---- Completed

93. Aravind Cotsyin (India) Ltd., Kolhapur ---- Completed.

94. Nahar Fibres Ltd., Ludhiana ---- Completed.

95. Rishab Spinning Mills Ludhiana …. Completed

96. Malwa Industries (Machchiwara) Ludhiana …. Under Commi.

Page 14: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

Sl. No. Name of the Customer Place STATUS

1 Prima Products Pvt. Ltd., Coimbatore Completed

2 Janaki Raman Mills Ltd., Rajapalayam Completed

3 Jay Textiles (LMV Group) Coimbatore Completed

4 Madanapalle Mills Ltd. Madanapalli Completed

5 Tirupur Textiles Ltd., Tirupur Completed

6 Shree Kaderi Ambal Mills Pvt. Ltd. Karaikudi Completed

7 Shree Akkamamba Textiles Ltd. Tanuku Completed

8 Thiyagarajar Mills Ltd., Kappalur Completed

9 Shri Sivakami Mills Ltd., Madurai Completed

10 Premier Polytronics Ltd., Coimbatore Completed

11 Vijayashree Spg.Mills Ltd., Dindigul Completed

12 Visaka Industries Ltd. Nagpur Completed

13 Surya Jhothi Spg. Mills Ltd., Secunderabad Completed

14 Premier Mills Ltd. Udumalpet Completed

15 Palani Andavar Cotton & Synthetics Mills Ltd Udumalpet Completed

16 Indocount Industries Ltd., Kolhapur Completed

17 M/s. Oil India Ltd., Duliajan, Assam Completed

18 MID India Spg. Mills Ltd Mandasur Completed

19 The Dawn Mills Mumbai Completed

20 Defence Mettalurgical Ltd Hyderabad Completed

21 Shree Meenakshi Sundaram Textile Ltd Hosur Completed

22 Premier Products (P) Ltd. Coimbatore Completed

23 Oswal Cotton Spg. Mills Ludhiana Completed

24 Ashok Leyland Ltd Hosur Completed

25 Ennore Thermal Power Station Chennai Completed

26 Hanil Era Textiles Ltd Mumbai Completed

27 Sanghi Spinners Sanghi Nagar Completed

28 Eastern Spg. Mills Ltd Calcutta Completed

29 BHEL-Hyderabad RIL-Jamnagar Completed

30 BHEL-Hyderabad KMCL- Neelachal Completed

31 BHEL-Hyderabad IOCL-Panipat Completed

32 Karthiga Enterprises Chennai Completed

33 Hyundai Motor India Ltd Sriperumbudur Completed

CUSTOMER LIST FOR CO2 FIRE EXTINGUISHING SYSTEM

Page : 1 of 2

Page 15: DIVERSIONSYSTEM - Agni Controlsbalafire.com/pdf/CO2.pdf · TEXTILE FIRE PROTECTION SYSTEM COMPONENTS ... Auro Dyeing Ludhiana LMW Completed 25. Sri Aruppukottai Jayavilas Mills Aruppukottai

Sl. No. Name of the Customer Place STATUS

CUSTOMER LIST FOR CO2 FIRE EXTINGUISHING SYSTEM

34 Hanil Era Textiles Ltd Mumbai Completed

35 Onshore Construction Co., Pvt. Ltd Mumbai Completed

36 Firepro Systems Pvt. Ltd. Bangalore Completed

37 Firepro Systems Pvt. Ltd. Bangalore Completed

38 TD Power Systems Pvt. Ltd Bangalore Completed

39 Indian Petrochemicals Corporation Ltd Gujarat Completed

40 Reliance Industries Ltd. Hazira Completed

41 Reliance Industries Ltd. Patalganga Completed

42 Vatech Hydro Bhopal Completed

43 Hyundai Motor India Ltd Sriperumbudur Completed

44 Visaka Industries Ltd. Nagpur Completed

45 Visaka Industries Ltd. Nagpur Completed

46 Tyco (Alert Safety Equipments) Banglore Completed

47 Hyundai Motor India Ltd Sriperumbudur Completed

48 Fire Fighters Engg. Chennai Completed

49 Fire Fighters Engg. Chennai Completed

50 Hyundai Motor India Ltd Sriperumbudur Completed

51 Paras Fire Protection Chennai Completed

52 Chentech Enterprises Chennai Completed

53 Visaka Industries Ltd. Nagpur Completed

54 Intek Security Systems (P) Ltd Bangalore Completed

55 Tyco (Alert Safety Equipments) Bangalore Completed

56 Hyundai Motor India Ltd Sriperumbudur Completed

57 GMR Energy Limited Mangalore Completed

58 Indian Oil Corporation Ltd., Mathura Refinery, Mathura (U.P) Mathura Completed

59 Essar Steel Limited Hazira Completed

60 Dekars Techno Engineering Hyderabad Completed

61 Reliance Industries Ltd. Hazira Completed

62 Alert Fire Services Bangalore Completed

63 Reliance Industries Ltd. Hazira Completed

64 M/s. Indian Oil Corporation Limited., Panipat Refinery, Panipat Completed

65 Tyco (Alert Safety Equipments) Bangalore Completed

66 Reliance Industries Ltd. Patalganga Completed

Page : 2 of 2