Direct heating system ECOFLOOR

Installation guide

Page 2: Direct heating system ECOFLOOR Installation guide

DIRECT HEATING SYSTEM ECOFLOOR - FOR NEW BUILDING APPLICATIONS

heating mat or heating cable is placed into flexible cement (glue), on 5 cm concrete layer.power density is used from 100 W/m2 (for habitable rooms with limited floor temperature) up to 160 W/m2(for bathrooms, laundries and no good heat-insulated floors)very good and easy temperature controlfloor heating is possible to combine with el.convectors or radiant panels

Page 3: Direct heating system ECOFLOOR Installation guide

DIRECT HEATING SYSTEM ECOFLOOR - FOR RECONSTRUCTION APPLICATIONS

modern floor heating with high level temperature controlsheating mat or heating cable is placed into thin layer of flexible cement (glue), on concrete layer or origin tiling. power density is used according to type of room (100 W/m2 or 160 W/m2)

Page 4: Direct heating system ECOFLOOR Installation guide

ADVANTAGES OF DIRECT FLOOR HEATING

quick reaction to the changes in the user‘s heat requirements (warming of floor up to 20 min) very good, accurate and easy temperature controlsuitable for renovated floors with limited construction height

Page 5: Direct heating system ECOFLOOR Installation guide

ECOFLOOR INSTALLATION

at first choose the right floor heating application (storage, semi-storage or direct heating )calculate the heating loses, total heating output should be greater 10-20 % then calculated heating loss According to type of room choose an appropriate heating density:

- permanentaly occupied rooms up to 100 W/sqm - rooms occupied for short periods (bathrooms, -

toilets) up to 160 W/sqm - laminated floors up to 80 W/sqm - wooden floors up to 60 W/sqm

Page 6: Direct heating system ECOFLOOR Installation guide

INSTALLATION NOTICES

minimum distance of floor heating system from walls and fixtures like bath, shower or toilet is 5 cm.

the heating cable may never be shortened or cutted !!! (only the cold connection lead)

NO!

Page 7: Direct heating system ECOFLOOR Installation guide

INSTALLATION NOTICES

Heating cables must not be crossed and must not be intersected each other. Minimum distance between heating cables is 3 cm

the connector between the cold connection and heating cable needs to be install in straight stretcht (never be installed at a bend!)

the heating cable may never pass over an expansion joint

Page 8: Direct heating system ECOFLOOR Installation guide

EXPANSIONWHY:

the floor construction expands when temperature rises and must be furnished with expansion elements to prevent the floor construction being stressed ( tiling could be damaged, base layer cracked and peeled etc.)

Expansion is necessary to provide:into place around the room‘s circumference, where floor heating will be used.( The whole floor construction must be a floating construction !)

expansion is necessary to provide for rooms with area 25 m2 and for diagonal 7 m.

Page 9: Direct heating system ECOFLOOR Installation guide

Expansion jointsthe choice of expansion joints depends on room‘s shape and structure - rooms with „L,Z,or T“ shapes should be divided into rectangular or squere sectionsExpansion joint must not be discontinued and for cementation process is recomended flexible cementECOFLOOR heating cables and mats may never cross the expansion joints ! If the cold connections pass the expansion joints, they must lay freely within protective tubes

Page 10: Direct heating system ECOFLOOR Installation guide

Heating mat/cable ECOFLOOR laying to the flexible cement (glue) –new building

1. On the base(1)place thermal insulation (2)– expanded polystyrene at least or extruded polystyrene of min. thickness 5 cm

2. Place the steel reinforcement (3)to harden the concrete layer. Place the concrete layer 5 cm thick(4)

3. Penetrate the concrete layer. ECOFLOOR cables/mats (6) place into flexible cement (5).

4. Measure el parameters of heating system and lay the tiles. (7)

Page 11: Direct heating system ECOFLOOR Installation guide

Heating mat/cable ECOFLOOR laying to the flexible cement (glue) – floor reconstruction

1. Clean and penetrate the original tiling2. Into flexible gluing cement place the

ECOFLOOR heating cables/mats3. Measure the parameters of heating cable/mat 4. Laying of new tiles

Page 12: Direct heating system ECOFLOOR Installation guide

Other possibility of ECOFLOOR laying

Wooden floor construction

Page 13: Direct heating system ECOFLOOR Installation guide

Other possibility of ECOFLOOR laying

Plasterboard floor construction

Page 14: Direct heating system ECOFLOOR Installation guide

Other possibility of ECOFLOOR layingConstruction with self-levelling

cement

Page 15: Direct heating system ECOFLOOR Installation guide

INSTALLATION OF ECOFLOOR HEATING CABLE CIRCUIT ADSL1P

COMFORT DIRECT FLOOR HEATING UNDER TILES

ADSV Heating cable circuit (double conductor with 1 connection lead „cold tail“

1. Control measuring

2. Grooving for thermostat floor

probe

3. Floor base cleaning and penetration

4. Floor probe installation

5. Fixation of el.conncector

6. Installation of Heating cable circuit 7. Control

measuring8. Thin layer flexible cementing (glueing)

9. New tiling

Page 16: Direct heating system ECOFLOOR Installation guide

INSTALLATION OF ECOFLOOR HEATING MAT LDTS COMFORT DIRECT FLOOR HEATING UNDER TILES

LDTS Heating mat (double conductor with 1 connection lead „cold tail“

1. Control measuring

2. Grooving for thermostat floor

probe

3. Floor base cleaning and penetration

4. Floor probe installation

5. Heating mat laying

6. Mat sticking to the floor base by its self-

adhesive tape7. Control measuring

8. Thin layer flexible cementing (glueing)

9. New tiling

6. Heating mat installation

Page 17: Direct heating system ECOFLOOR Installation guide

FLOORING MATERIALThe most suitable for ECOFLOOR systems:ceramic tile, marble, natural stone

Other suitable:Laminate floating and wooden parquet floors

PVC without a rubber baseSpecial carpets without rubber base recommended by their manufacturers for use with floor heating

Unsuitable !!!:Carpets with pile more than 10 mm thick or with a rubber base

PVC with a rubber

Page 18: Direct heating system ECOFLOOR Installation guide

Electrical installation

ECOFLOOR heating cable/mat has to be connected to the el.net just by a qualified person accordance with the manufacturer´s instructionsThe total take-off (Amps) of heating mat/cable must never exceed the maximum value of thermostat switched current

Page 19: Direct heating system ECOFLOOR Installation guide

For floor heating are suitable following thermostats:

Fenix Therm 100 Eco M/z1

Microline OCD 1999 H

Eberle Instat 8

TEMPERATURE CONTROLS

Fenix Therm 100

Page 20: Direct heating system ECOFLOOR Installation guide

Thermostat connection (thermostat with floor probe)

L – phase (el.supply)N – neutral (el.supply)L’ –phase (Ecofloor)N’ – neutral (Ecofloor)

Page 21: Direct heating system ECOFLOOR Installation guide
Page 22: Direct heating system ECOFLOOR Installation guide

Electrical installation directly throught the thermostat

Page 23: Direct heating system ECOFLOOR Installation guide

Electrical installation throught the el.box and contactor(1 thermostat controls 2 Ecofloor units (cables/mats) through the contactor to prevent thermostat switch current overloading)

Page 24: Direct heating system ECOFLOOR Installation guide

Direct heating ECOFLOOR Modern and comfort floor heating system