din standard marine cable - shipserv marine... · din standard marine cable chongqing lange...
TRANSCRIPT
DIN standard marine cable
Chongqing Lange Machinery Group Co,.LTD
No.65 North Jianxin road,jiangbei distric,chongqing,china Cell phone: +86-18623290269 Skype: lange.marine-elec5 E-mail: [email protected] Tel: +86-23-67698698 EXT 8103 Fax: +86-23-67698691 Web: www.langemachinery.com
professional and valuable
技术创造价值 专业铸就品牌
Marine cableDIN standard
Power Cable 600/1000V
MGCG ------ Shipboard Power Cables(screen/armour) ----------------------------------------- 3- 5
MGCH ----- Halogen Free Power Cables with screen (armour) ------------------------------- 9- 11
MGG --------Shipboard Power Cables without screen ------------------------------------------- 6- 8
MGCH-F --- Halogen Free ,Fire Resistant Power Cables with screen (armour) ---------- 12-14
MGH ------- Halogen Free Power Cables without screen ------------------------------------ 15-17
MPRXCX - Shipboard Halogen Free, Power Cables with screen (armour) --------------- 18-20
MPRXCX331 - Halogen Free,Fire Resistant Power Cables with screen(armour) ------ 21-22
MPRX ------ Shipboard Halogen Free Power Cables without screen ----------------------- 23-25
MPRX331 - Halogen Free,Fire Resistant Power Cables without screen ------------------ 26-27
Communication Cable 150/250V
FMGCG --- Communication cable with screen(armour) -------------------------------------- 28-29
FMGCH --- Halogen Free Communication cable with screen(armour) -------------------- 30-31
FMGCH-F - Halogen Free,Fire Resistant Communication cable with screen ------------ 32-33
FMKHC --- Halogen Free Communication cable with screen(armour) ------------------- 34-35
FMKHC-F - Halogen Free,Fire Resistant Communication cable with screen ----------- 36-37
DIN Standard Marine shipboard cable
Design
3
Marine Power Cables (screen/armour) 0.6/1KV
*Rated Voltage Uo/U(Um) 600/1000V
3.Filler or Tape
1.Conductor:Annealed Stranded Bare Copper,Class 2
Electrical Characteristics
2.Insulation:HEPR (Crosslinked Hard grade Ethylene Propylene)
4.Armour:Separator tape/Bare copper braid/Separator tape
Standards : DIN 89158
5.Sheath:Cross linked polychloroprene rubber
*Short-circuit max.conductor temperature
*Max.conductor temperature in service
IEC 60332-3 Cat. A
*For overall diameter of cables > 25mm
Applications*For fixed installations on ships and offshore-units in all locations.
IEC 61034
Yes
IEC 60754-2
No toxicity to IEC 60754-1
Minimum Internal Bending Radius4xcable diameter
6xcable diameter
*Gases Toxicity
*For overall diameter of cables ≤ 25mm
*Good copper braid screening quality reduce radio interferences and electrical in fluences to electronic installation.
*Gases Corrosivity
*Electro magnetic interference resistance
*Smoke Density
*Flame Retardant
MGCG 0.6/1KV
85 °C
250 °C
–35 °C*Minimum operating temperature
–10 °C*Minimum installation temperature
Usage Characteristics
3500V*Test Voltage
CrossSection
mm2 Min.(mm) Max.(mm)
MMLE602-MGCG01 1 4 6 8.5
MMLE602-MGCG02 1 6 7 9.5
MMLE602-MGCG03 1 10 8 10.5
MMLE602-MGCG04 1 16 9 11.5
MMLE602-MGCG05 1 25 11 13.5
MMLE602-MGCG06 1 35 12 14.5
MMLE602-MGCG07 1 50 14 16.5
MMLE602-MGCG08 1 70 16 18.5
MMLE602-MGCG09 1 95 18 21
MMLE602-MGCG10 1 120 19.5 22.5
MMLE602-MGCG11 1 150 21.5 25
MMLE602-MGCG12 1 185 23.5 27
MMLE602-MGCG13 1 240 26.5 30
MMLE602-MGCG14 1 300 29 32.5
MMLE602-MGCG15 2 1.5 10 12.5
MMLE602-MGCG16 2 2.5 11 13.5
MMLE602-MGCG17 2 4 12 14.5
MMLE602-MGCG18 2 6 14 16.5
MMLE602-MGCG19 2 10 15.5 18.5
MMLE602-MGCG20 2 16 18 21
MMLE602-MGCG21 2 25 20.5 24.5
MMLE602-MGCG22 3 1.5 10.5 13
MMLE602-MGCG23 3 2.5 11.5 14
MMLE602-MGCG24 3 4 12.5 15
MMLE602-MGCG25 3 6 14.5 17
MMLE602-MGCG26 3 10 16.5 19.5
MMLE602-MGCG27 3 16 19 22
MMLE602-MGCG28 3 25 22 25.5
MMLE602-MGCG29 3 35 24.5 28.5
MMLE602-MGCG30 3 50 28 31.5
MMLE602-MGCG31 3 70 32.5 37
MMLE602-MGCG32 3 95 37 41.5
MMLE602-MGCG33 3 120 40.5 46
MMLE602-MGCG34 4 1.5 11 13.5
4
Approx WeightProduct No Core No
Out Diameter
KG/KM
MGCG 0.6/1KV
110
140
190
270
380
480
660
900
1170
1410
1750
2160
2770
3440
180
220
280
380
500
710
1020
210
260
330
450
620
870
1280
1680
2180
3020
4050
5000
240
CrossSection
mm2 Min.(mm) Max.(mm)
MMLE602-MGCG35 4 2.5 12.5 16
MMLE602-MGCG36 4 4 14 16.5
MMLE602-MGCG37 4 6 15.5 18.5
MMLE602-MGCG38 4 10 18 21
MMLE602-MGCG39 4 16 20.5 24
MMLE602-MGCG40 4 25 24.5 28
MMLE602-MGCG41 4 35 27 31
MMLE602-MGCG42 4 50 30.5 35.5
MMLE602-MGCG43 4 70 36.5 41
MMLE602-MGCG44 4 95 41.5 46
MMLE602-MGCG45 5 1.5 12 14.5
MMLE602-MGCG46 5 2.5 14 16.5
MMLE602-MGCG47 7 1.5 13 15.5
MMLE602-MGCG48 10 1.5 15.5 18.5
MMLE602-MGCG49 12 1.5 16.5 19.5
MMLE602-MGCG50 14 1.5 17 20
MMLE602-MGCG51 16 1.5 18.5 21MMLE602-MGCG52 19 1.5 19 22
MMLE602-MGCG53 24 1.5 22.5 25.5
5
300
430
MGCG 0.6/1KV
Product No Core NoOut Diameter Approx Weight
KG/KM
540
780
1090
1630
2120
2750
3900
5160
290
400
380
450
630710
500
560
880
Standards : DIN 89158
2.Insulation:HEPR (Crosslinked Hard grade Ethylene Propylene)
6
Shipboard Power Cables without screen
Electrical Characteristics600/1000V3500V
4.Sheath:Cross linked polychloroprene rubber
*Rated Voltage Uo/U(Um)*Test Voltage
Usage Characteristics*Minimum installation temperature –10 °C
–35 °C*Minimum operating temperature250 °C85 °CIEC 60332-3 Cat. AIEC 61034IEC 60754-2No toxicity to IEC 60754-1
4xcable diameter6xcable diameter
Applications*For fixed installations on ships and offshore-units in all locations.
*For overall diameter of cables> 25mm
*Meet the Flame test requirements for bunched cables according to IEC 60332-3-22&IEEE 45-18.13.
3.Filler or Tape
*Short-circuit max.conductor temperature*Max.conductor temperature in service*Flame Retardant*Smoke Density*Gases Corrosivity*Gases Toxicity
Minimum Internal Bending Radius*For overall diameter of cables < 25mm
Design1.Conductor:Annealed Stranded Bare Copper,Class 2
MGG 0.6/1KV
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGG01 1 10 7.5 9.5
MMLE602-MGG02 1 120 18 20.5
MMLE602-MGG03 1 150 20 22.5
MMLE602-MGG04 1 16 8.5 10.5
MMLE602-MGG05 1 185 22 25
MMLE602-MGG06 1 240 25 28
MMLE602-MGG07 1 25 10 12
MMLE602-MGG08 1 300 28 31
MMLE602-MGG09 1 35 11 13
MMLE602-MGG10 1 4 5.5 7.5
MMLE602-MGG11 1 50 12.5 14.5
MMLE602-MGG12 1 6 6.5 8.5
MMLE602-MGG13 1 70 14.5 16.5
MMLE602-MGG14 1 95 16.5 19
MMLE602-MGG15 10 1.5 14.5 17
MMLE602-MGG16 12 1.5 15 17.5
MMLE602-MGG17 14 1.5 15.5 18.5
MMLE602-MGG18 16 1.5 16.5 19.5
MMLE602-MGG19 19 1.5 17.5 20.5
MMLE602-MGG20 2 1.5 9 11.5
MMLE602-MGG21 2 10 14.5 17
MMLE602-MGG22 2 16 16.5 19.5
MMLE602-MGG23 2 2.5 9.5 12
MMLE602-MGG24 2 25 19.5 22.5
MMLE602-MGG25 2 4 11 13.5
MMLE602-MGG26 2 6 12 14.5
MMLE602-MGG27 24 1.5 20.5 23.5
MMLE602-MGG28 3 1.5 9.5 12
MMLE602-MGG29 3 10 15 17.5
MMLE602-MGG30 3 120 38.5 43.5
MMLE602-MGG31 3 16 17.5 20
MMLE602-MGG32 3 2.5 10.5 13
MMLE602-MGG33 3 25 20.5 24
MMLE602-MGG34 3 35 23 26.5
MMLE602-MGG35 3 4 11.5 14
MMLE602-MGG36 3 50 26.5 30
7
Approx Weight
KG/KM
MGG 0.6/1KV
Product No Core NoOut Diameter
150
1290
1590
220
1960
2560
320
3200
420
80
560
110
780
1030
360
410
470
530
610
130
410
590
170
880
220
280
760
160
1970
510
4580
750
210
1130
1500
270
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGG37 3 6 13 15.5
MMLE602-MGG38 3 70 31 35
MMLE602-MGG39 3 95 35 39.5
MMLE602-MGG40 4 1.5 10 12.5
MMLE602-MGG41 4 10 16.5 19.5
MMLE602-MGG42 4 16 19.5 22.5
MMLE602-MGG43 4 2.5 11 13.5
MMLE602-MGG44 4 25 22.5 26.5
MMLE602-MGG45 4 35 25.5 29
MMLE602-MGG46 4 4 12.5 15
MMLE602-MGG47 4 50 29 33
MMLE602-MGG48 4 6 14 16.5
MMLE602-MGG49 4 70 34.5 39
MMLE602-MGG50 4 95 39 44
MMLE602-MGG51 5 1.5 11 13.5
MMLE602-MGG52 5 2.5 12 14.5
MMLE602-MGG53 7 1.5 12 14.5
8
350
2770
3680
200
660
950
250
1460
230
300
1920
330
2520
440
MGG 0.6/1KV
Product No Core NoOut Diameter Approx Weight
KG/KM
290
3530
4730
Halogen Free Power Cables with screen (armour)
1.Conductor:Annealed Stranded Bare Copper,Class 22.Insulation : HEPR (Crosslinked Hard grade Ethylene Propylene)
9
MGCH 0.6/1KV
Standards : DIN 89158
3.Filler or Tape: 4.Armour : Separator tape/bare copper braid5.Sheath : Polyolefin
Electrical Characteristics*Rated Voltage Uo/U(Um) 600/1000V*Test Voltage 3500V
Usage Characteristics*Minimum installation temperature –10 °C*Minimum operating temperature –35 °C*Short-circuit max.conductor temperature 250 °C
85 °C*Flame Retardant IEC 60332-3 Cat. A*Smoke Density IEC 61034
*Max.conductor temperature in service
IEC 60754-2*Gases Corrosivity*Gases Toxicity No toxicity to IEC 60754-1
Minimum Internal Bending Radius
influences to electronic installation.*Meet the Flame test requirements for bunched cables according to IEC 60332-3-22&IEEE 45-18.13.
6xcable diameter
Applications*For fixed installations on ships and offshore-units in all locations.*The fantastic screening qualities of the copper braid also reduce radio interferences and electrical
*For all cables
*Free halogen materials ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.
Design
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGCH01 1 4 6 8.5
MMLE602-MGCH02 1 6 7 9.5
MMLE602-MGCH03 1 10 8 10.5
MMLE602-MGCH04 1 16 9 11.5
MMLE602-MGCH05 1 25 11 13.5
MMLE602-MGCH06 1 35 12 14.5
MMLE602-MGCH07 1 50 14 16.5
MMLE602-MGCH08 1 70 16 18.5
MMLE602-MGCH09 1 95 18 21
MMLE602-MGCH10 1 120 19.5 22.5
MMLE602-MGCH11 1 150 21.5 25
MMLE602-MGCH12 1 185 23.5 27
MMLE602-MGCH13 1 240 26.5 30
MMLE602-MGCH14 1 300 29 32.5
MMLE602-MGCH15 2 1.5 10 12.5
MMLE602-MGCH16 2 2.5 11 13.5
MMLE602-MGCH17 2 4 12 14.5
MMLE602-MGCH18 2 6 14 16.5
MMLE602-MGCH19 2 10 15.5 18.5
MMLE602-MGCH20 2 16 18 21
MMLE602-MGCH21 2 25 20.5 24.5
MMLE602-MGCH22 3 1.5 10.5 13
MMLE602-MGCH23 3 2.5 11.5 14
MMLE602-MGCH24 3 4 12.5 15
MMLE602-MGCH25 3 6 14.5 17
MMLE602-MGCH26 3 10 16.5 19.5
MMLE602-MGCH27 3 16 19 22
MMLE602-MGCH28 3 25 22 25.5
MMLE602-MGCH29 3 35 24.5 28.5
MMLE602-MGCH30 3 50 28 31.5
MMLE602-MGCH31 3 70 32.5 37
MMLE602-MGCH32 3 95 37 41.5
MMLE602-MGCH33 3 120 40.5 46
MMLE602-MGCH34 4 1.5 11 13.5
MMLE602-MGCH35 4 2.5 12.5 16
MMLE602-MGCH36 4 4 14 16.5
MMLE602-MGCH37 4 6 15.5 18.5
10
870
1680
2180
3020
1280
4050
5000
240
300
430
540
140
190
KG/KM110
Approx Weight
MGCH 0.6/1KV
480
660
Product No Core NoOut Diameter
270
380
900
1170
1410
1750
2160
2770
3440
180
220
280
380
500
710
1020
210
260
330
450
620
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGCH38 4 10 18 21MMLE602-MGCH39 4 16 20.5 24MMLE602-MGCH40 4 25 24.5 28MMLE602-MGCH41 4 35 27 31MMLE602-MGCH42 4 50 30.5 35.5MMLE602-MGCH43 4 70 36.5 41MMLE602-MGCH44 4 95 41.5 46MMLE602-MGCH45 5 1.5 12 14.5MMLE602-MGCH46 5 2.5 14 16.5MMLE602-MGCH47 7 1.5 13 15.5MMLE602-MGCH48 10 1.5 15.5 18.5MMLE602-MGCH49 12 1.5 16.5 19.5MMLE602-MGCH50 14 1.5 17 20MMLE602-MGCH51 16 1.5 18.5 21MMLE602-MGCH52 19 1.5 19 22MMLE602-MGCH53 24 1.5 22.5 25.5
11
630
450
78010901630
380
560
KG/KM
2120
710880
500
Approx Weight
MGCH 0.6/1KV
Product No Core NoOut Diameter
275039005160290400
* Insulation : HEPR(Cross-linked Ethylene Propylene Rubber)
12
*For all cables 6xcable diameter
Applications*For fixed installations on ships and offshore-units in all locations.
*Electro magnetic interference resistance YESMinimum Internal Bending Radius
*Gases Corrosivity IEC 60754-2*Gases Toxicity No toxicity to IEC 60754-1
*Fire Resistant IEC 60331*Smoke Density IEC 61034
*Max.conductor temperature in service 85 Degree Centigrade*Flame Retardant IEC 60332-3 Cat. A
*Minimum operating temperature 35 Degree Below Zero Centigrade*Short-circuit max.conductor temperature 250 Degree Centigrade
*Test Voltage 3500V
Usage Characteristics*Minimum installation temperature 10 Degree Below Zero Centigrade
Electrical Characteristics
4.Armour : Separator tape/bare copper braid
*Rated Voltage Uo/U(Um) 600/1000V
2.Insulation : Fire Barriers
3.Filler or Tape
Standards : DIN 89158
MGCH-F 0.6/1KV
5.Sheath : Polyolefin
*Meet the Fire resistance characteristics according to IEC 60331-21.*Free halogen materials ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.
influences to electronic installation.*The fantastic screening qualities of the copper braid also reduce radio interferences and electrical
Halogen Free,Fire Resistant Power Cables with screen (armour),0.6/1KV
*Meet the Flame test requirements for bunched cables according to IEC 60332-3-22&IEEE 45-18.13.
1.Conductor : Annealed Stranded Bare Copper,Class 2Design
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGCH-F01 1 25 11.5 13.5MMLE602-MGCH-F02 1 35 12.5 14.5MMLE602-MGCH-F03 1 50 14.5 16.5MMLE602-MGCH-F04 1 70 16 18.5MMLE602-MGCH-F05 1 95 18 21MMLE602-MGCH-F06 1 120 19.5 22.5MMLE602-MGCH-F07 2 1.5 11.5 13.5MMLE602-MGCH-F08 2 2.5 12 14MMLE602-MGCH-F09 2 4 12.5 15MMLE602-MGCH-F10 2 6 14.5 17MMLE602-MGCH-F11 2 10 16.5 19.5MMLE602-MGCH-F12 2 16 18.5 21.5MMLE602-MGCH-F13 2 25 21 25MMLE602-MGCH-F14 3 1.5 12 14MMLE602-MGCH-F15 3 2.5 12.5 15MMLE602-MGCH-F16 3 4 13.5 16MMLE602-MGCH-F17 3 6 15 17.5MMLE602-MGCH-F18 3 10 17.5 20MMLE602-MGCH-F19 3 16 19 22MMLE602-MGCH-F20 3 25 22.5 25.5MMLE602-MGCH-F21 3 35 25 28.5MMLE602-MGCH-F22 3 50 28.5 32MMLE602-MGCH-F23 3 70 33 37MMLE602-MGCH-F24 3 95 37 41.5MMLE602-MGCH-F25 3 120 41.5 45MMLE602-MGCH-F26 4 1.5 12 14.5MMLE602-MGCH-F27 4 2.5 13.5 16.5MMLE602-MGCH-F28 4 4 15 17MMLE602-MGCH-F29 4 6 16.5 19MMLE602-MGCH-F30 4 10 19 22MMLE602-MGCH-F31 4 16 21.5 24.5MMLE602-MGCH-F32 4 25 25.5 28.5MMLE602-MGCH-F33 5 1.5 13 15.5MMLE602-MGCH-F34 5 2.5 15 17.5MMLE602-MGCH-F35 7 1.5 15 17.5MMLE602-MGCH-F36 10 1.5 18 20.5MMLE602-MGCH-F37 12 1.5 18.5 21
13
400460510
11201670320440
330460560790
305040805030270
880130016802190
11801430210
670
350480
1050230280
720
390490670
250300410550
Approx Weight
910
KG/KMProduct No Core No
Out Diameter
MGCH-F 0.6/1KV
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGCH-F38 14 1.5 19 22MMLE602-MGCH-F39 16 1.5 20 23MMLE602-MGCH-F40 19 1.5 21.5 24.5MMLE602-MGCH-F41 24 1.5 25 28
14
730910
570640
MGCH-F 0.6/1KV
Product No Core NoOut Diameter Approx Weight
KG/KM
1.Conductor : Annealed Stranded Bare Copper,Class 22.Insulation : HEPR (Crosslinked Hard grade Ethylene Propylene)
15
3.Filler or Tape
Halogen Free Power Cables without screen
Standards : DIN 89160
4.Sheath : Polyolefin
Electrical Characteristics*Rated Voltage Uo/U(Um) 600/1000V*Test Voltage 3500V
Usage Characteristics*Flame Retardant IEC 60332-3 Cat. A*Smoke Density IEC 61034*Gases Corrosivity IEC 60754-2*Gases Toxicity No toxicity to IEC 60754-1
Applications*For fixed installations on ships and offshore-units in all locations.
Minimum Internal Bending Radius
*for overall diameter of cables > 25 mm 6*cable diameter
*Meet the Flame test requirements for bunched cables according to IEC 60332-3-22&IEEE 45-18.13.*Free halogen materials ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, these cables are especially suitable for the installation on passenger ships.
*for overall diameter of cables < 25 mm 4*cable diameter
Design
MGH 0.6/1KV
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGH01 1 4 5.5 7.5MMLE602-MGH02 1 6 6.5 8.5MMLE602-MGH03 1 10 7.5 9.5MMLE602-MGH04 1 16 8.5 10.5MMLE602-MGH05 1 25 10 12MMLE602-MGH06 1 35 11 13MMLE602-MGH07 1 50 12.5 14.5MMLE602-MGH08 1 70 14.5 16.5MMLE602-MGH09 1 95 16.5 19MMLE602-MGH10 1 120 18 20.5MMLE602-MGH11 1 150 20 22.5MMLE602-MGH12 1 185 22 25MMLE602-MGH13 1 240 25 28MMLE602-MGH14 1 300 28 31MMLE602-MGH15 2 1.5 9 11.5MMLE602-MGH16 2 2.5 9.5 12MMLE602-MGH17 2 4 11 13.5MMLE602-MGH18 2 6 12 14.5MMLE602-MGH19 2 10 14.5 17MMLE602-MGH20 2 16 16.5 19.5MMLE602-MGH21 2 25 19.5 22.5MMLE602-MGH22 3 1.5 9.5 12MMLE602-MGH23 3 2.5 10.5 13MMLE602-MGH24 3 4 11.5 14MMLE602-MGH25 3 6 13 15.5MMLE602-MGH26 3 10 15 17.5MMLE602-MGH27 3 16 17.5 20MMLE602-MGH28 3 25 20.5 24MMLE602-MGH29 3 35 23 26.5MMLE602-MGH30 3 50 26.5 30MMLE602-MGH31 3 70 31 35MMLE602-MGH32 3 95 35 39.5MMLE602-MGH33 3 120 38.5 43.5MMLE602-MGH34 4 1.5 10 12.5MMLE602-MGH35 4 2.5 11 13.5MMLE602-MGH36 4 4 12.5 15MMLE602-MGH37 4 6 14 16.5
16
10301290
420560780
110150220320
Out Diameter Approx Weight
KG/KM80
Product No Core No
1590196025603200130170220280410590880160
15001970
210270350510
250330440
MGH 0.6/1KV
277036804580200
7501130
CrossSection
mm2 Min.(mm) Max.(mm)MMLE602-MGH38 4 10 16.5 19.5MMLE602-MGH39 4 16 19.5 22.5MMLE602-MGH40 4 25 22.5 26.5MMLE602-MGH41 4 35 25.5 29MMLE602-MGH42 4 50 29 33MMLE602-MGH43 4 70 35.5 39MMLE602-MGH44 4 95 39 44MMLE602-MGH45 5 1.5 11 13.5MMLE602-MGH46 5 2.5 12 14.5MMLE602-MGH47 7 1.5 12 14.5MMLE602-MGH48 10 1.5 14.5 17MMLE602-MGH49 12 1.5 15 17.5MMLE602-MGH50 14 1.5 15.5 18.5MMLE602-MGH51 16 1.5 16.5 19.5MMLE602-MGH52 19 1.5 17.5 20.5MMLE602-MGH53 24 1.5 20.5 23.5
17
Approx Weight
19202520
660
Product No Core NoOut Diameter
760
290360410470530610
35304730230300
9501460
KG/KM
MGH 0.6/1KV
1.Conductor : Annealed Standard Copper,class2.2.Insulation : XLPE(Cross-Linked Polyethylene)
18
MPRXCX 0.6/1 kV
Minimum operating temperatureFlame retardantSmoke Density
*Especially suitable for installation on passenger ships.
*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)
Gases corrosivityGases toxicityElectro magnetic interference resistanceMinimum internal bending radius
Standard : DIN&IEC
Shipboard Halogen Free, Power Cables with screen (armour)
4.Armour : Separator tape,bare copper brai5.Outer sheath : Polyolefin
Electrical CharacteristicsRated Voltage Uo/U(Um) 0.6/1 kV
Test Voltage
Design
3.Inner covering(lapped)
3500 VMaximum operating voltage 1.2 kV
–10 °C
Usage CharacteristicsMax.Conductor temperature in service 90 °CShort-circuit max.conductor temperature 250 °CMinimum installation temperature
IEC 61034IEC 60332-3 Cat. A–35 °C
6*cable DiameterYESNo toxicity to IEC 60754-1No IEC 60754-2
*For fixed installations in communication,radio,control,data processing facilities on ship and offshore.Applications
*Halogen Free cable materials ensure non corrosive and low toxic gases are emitted in case of fire.
installations.*Good copper braid screening qualities reduce radio interferences and electrical influences to electronic
Cross Section(mm2) Min(mm) Max(mm)
1 4 6.9 8.41 6 7.5 9.51 10 8.7 10.71 16 9.5 11.51 25 11.7 13.41 35 12.6 15.11 50 14.6 17.11 70 16.9 19.41 95 18.6 21.11 120 19.7 22.21 150 22.6 25.11 185 24.7 27.21 240 27.9 30.41 300 30.2 32.72 1.5 8.3 9.82 2.5 9.1 10.62 4 10.3 11.82 6 12.1 14.12 10 14.9 16.92 16 16.7 18.72 25 20.3 22.33 1.5 8.8 10.33 2.5 10.1 11.63 4 11.1 12.63 6 12.1 14.13 10 14.8 16.83 16 17.6 19.63 25 21.2 23.23 35 20.8 23.33 50 24.3 26.8
19
MPRXCX 0.6/1 kV
95014701870
900117014101750216027703440
MMLE602-MPRXCX29MMLE602-MPRXCX30
MMLE602-MPRXCX25MMLE602-MPRXCX26MMLE602-MPRXCX27MMLE602-MPRXCX28
MMLE602-MPRXCX21MMLE602-MPRXCX22MMLE602-MPRXCX23MMLE602-MPRXCX24
MMLE602-MPRXCX17MMLE602-MPRXCX18MMLE602-MPRXCX19MMLE602-MPRXCX20
MMLE602-MPRXCX13MMLE602-MPRXCX14MMLE602-MPRXCX15MMLE602-MPRXCX16
MMLE602-MPRXCX09MMLE602-MPRXCX10MMLE602-MPRXCX11MMLE602-MPRXCX12
MMLE602-MPRXCX05MMLE602-MPRXCX06MMLE602-MPRXCX07MMLE602-MPRXCX08
MMLE602-MPRXCX01MMLE602-MPRXCX02MMLE602-MPRXCX03MMLE602-MPRXCX04
kg/km
130160
180130
560840160200250360520750
205290400
Product No. Core No.
660480380250
Approx.WeightOuter Diameter
105
Cross Section(mm2) Min(mm) Max(mm)
3 70 27.6 30.13 95 31.8 34.33 120 34.3 36.84 1.5 10.1 11.64 2.5 11.2 12.74 4 12.3 13.84 6 14 164 10 17.2 19.24 16 19.4 21.44 25 23.8 25.84 35 23 25.54 50 26 28.54 70 31.5 344 95 35.5 385 1.5 10.9 12.45 2.5 12.1 13.67 1.5 11.7 13.2
10 1.5 14.5 1612 1.5 15.3 16.814 1.5 16.5 1816 1.5 17.7 19.219 1.5 18.3 19.824 1.5 20 21.5
20
Outer Diameter Approx.Weightkg/km
550MMLE602-MPRXCX52MMLE602-MPRXCX53
440500
770620
225330310400
1930250035504600
450670950
1470
4300200240350
2650
MMLE602-MPRXCX49MMLE602-MPRXCX50MMLE602-MPRXCX51
MMLE602-MPRXCX45MMLE602-MPRXCX46MMLE602-MPRXCX47MMLE602-MPRXCX48
MMLE602-MPRXCX41MMLE602-MPRXCX42MMLE602-MPRXCX43MMLE602-MPRXCX44
MMLE602-MPRXCX37MMLE602-MPRXCX38MMLE602-MPRXCX39MMLE602-MPRXCX40
MMLE602-MPRXCX33MMLE602-MPRXCX34MMLE602-MPRXCX35MMLE602-MPRXCX36
MMLE602-MPRXCX31MMLE602-MPRXCX32
MPRXCX 0.6/1 kV
Product No. Core No.
3500
1.Conductor : Annealed Standard Copper,class2.2.Insulation : Mica Tape+XLPE(Cross-Linked Polyethylene)
*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)
installations.
*Especially suitable for installation on passenger ships.
Test Voltage 3500 VUsage CharacteristicsMax.Conductor temperature in serviceShort-circuit max.conductor temperatureMinimum installation temperatureMinimum operating temperature
*Halogen Free cable materials ensure non corrosive and low toxic gases are emitted in case of fire.
Flame Retardant
–10 °C
IEC 60754-2IEC 61034
IEC 60332-3 Cat. A–35 °C
Standard : DIN&IEC
Halogen Free,Fire Resistant Power Cables with screen(armour)
Rated Voltage Uo/U(Um) 0.6/1 kVMaximum operating voltage 1.2 kV
*Good copper braid screening qualities reduce radio interferences and electrical influences to electronic
Design
3.Inner covering(lapped)
Smoke DensityGases corrosivityGases toxicity
Fire Resistant
*For fixed installations on ships and offshore-units at all levels and open deck in safety circuits,whereApplications
4.Armour : Separator tape,bare copper brai5.Outer sheath : Polyolefin
Electrical Characteristics
fire Resistance is required.
21
IEC 60331-21
MPRXCX331 0.6/1 kV
6*cable DiameterYESNo toxicity to IEC 60754-1
Electro magnetic interference resistanceMinimum internal bending radius
250 °C90 °C
Cross Section(mm2)
1 251 351 501 701 951 1202 1.52 2.52 42 62 102 162 253 1.53 2.53 43 63 103 163 253 353 503 703 953 1204 1.54 2.54 44 64 104 164 254 355 1.57 1.5
12 1.519 1.5
17
20.523
27.5
18
37.5
1441
15
25
29.533.5
27
1415
1921
17
15.517.520
1323.5
MMLE602-MPRXCX331-34MMLE602-MPRXCX331-35MMLE602-MPRXCX331-36MMLE602-MPRXCX331-37
22
21.5 24.5
26.5
18.5
1516.5
12.514
21.5
29.5
15.518
20.524.5
26.530.53437
11.512.514.5
12.514.516.518.522.524
MMLE602-MPRXCX331-30MMLE602-MPRXCX331-31
17.521
10.511.5
151719
14.5
21.523.512.513.5
18.520.510
11.512.514.516.5
MMLE602-MPRXCX331-32MMLE602-MPRXCX331-33
MMLE602-MPRXCX331-26MMLE602-MPRXCX331-27MMLE602-MPRXCX331-28MMLE602-MPRXCX331-29
MMLE602-MPRXCX331-22MMLE602-MPRXCX331-23MMLE602-MPRXCX331-24MMLE602-MPRXCX331-25
MMLE602-MPRXCX331-18MMLE602-MPRXCX331-19MMLE602-MPRXCX331-20MMLE602-MPRXCX331-21
MMLE602-MPRXCX331-14MMLE602-MPRXCX331-15MMLE602-MPRXCX331-16MMLE602-MPRXCX331-17
MMLE602-MPRXCX331-10MMLE602-MPRXCX331-11MMLE602-MPRXCX331-12MMLE602-MPRXCX331-13
MMLE602-MPRXCX331-06MMLE602-MPRXCX331-07MMLE602-MPRXCX331-08MMLE602-MPRXCX331-09
MMLE602-MPRXCX331-02MMLE602-MPRXCX331-03MMLE602-MPRXCX331-04MMLE602-MPRXCX331-05
MMLE602-MPRXCX331-01
Product No. Core No. Outer DiameterMin(mm)
14
MPRXCX 0.6/1 kV
Outer DiameterMax(mm)
11121315
1.Conductor : Annealed Standard Copper,class2.2.Insulation : XLPE(Cross-Linked Polyethylene)
23
4*cable diameter6*cable diameter
Applications*For fixed installations on ships and offshore-units at all locations below the upper metallic deck.*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)
Minimum operating temperatureFlame Retardant
for overall diameter of cable < 25mmfor overall diameter of cable> 25mm
Smoke DensityGases corrosivityGases toxicity
Minimum internal bending radius
IEC 60754-2IEC 61034
Max.Conductor temperature in service 90 °CShort-circuit max.conductor temperature 250 °C
*Halogen Free cable materials ensure non corrosive and low toxic gases are emitted in case of fire.*Especially suitable for installation on passenger ships.
Minimum installation temperature–35 °C
No toxicity to IEC 60754-1
Standard : DIN&IEC
MPRX 0.6/1 kV
Design
3.Outer sheath : Polyolefin
IEC 60332-3 Cat. A
Shipboard Halogen Free Power Cables without screen
–10 °C
3500 V1.2 kV
Electrical CharacteristicsRated Voltage Uo/U(Um) 0.6/1 kVMaximum operating voltageTest Voltage
Usage Characteristics
Cross Section(mm2) Min(mm) Max(mm)
1 4 5.5 81 6 6 8.51 10 7 9.51 16 8 10.51 25 9.5 121 35 10.5 131 50 12 14.51 70 14 16.51 95 16 191 120 18 211 150 20 23.51 185 22 25.51 240 25 28.51 300 27.5 31.52 1.5 7 9.52 2.5 8 10.52 4 9 11.52 6 10 12.52 10 12.5 152 16 14.5 172 25 18 20.53 1.5 8 10.53 2.5 9 11.53 4 10 12.53 6 11 13.53 10 13 15.53 16 15.5 183 25 19 21.53 35 20.5 23.53 50 24 273 70 26.5 29.53 95 30.5 34
24
MPRX 0.6/1 kV
3305
970129017202450
145190290430
190260410600
MMLE602-MPRX32
MMLE602-MPRX28MMLE602-MPRX29MMLE602-MPRX30MMLE602-MPRX31
MMLE602-MPRX24MMLE602-MPRX25MMLE602-MPRX26MMLE602-MPRX27
MMLE602-MPRX20MMLE602-MPRX21MMLE602-MPRX22MMLE602-MPRX23
MMLE602-MPRX16MMLE602-MPRX17MMLE602-MPRX18MMLE602-MPRX19
MMLE602-MPRX12MMLE602-MPRX13MMLE602-MPRX14MMLE602-MPRX15
MMLE602-MPRX08MMLE602-MPRX09MMLE602-MPRX10MMLE602-MPRX11
Product No. Core No. Outer Diameterkg/km
Approx.Weight
320
MMLE602-MPRX01
MMLE602-MPRX039570
MMLE602-MPRX05MMLE602-MPRX04
MMLE602-MPRX02
MMLE602-MPRX06MMLE602-MPRX07
1960
680
560420
1030780
25603200
80105
100140
200140
12901590
Cross Section(mm2) Min(mm) Max(mm)
3 120 33.5 37.54 1.5 8.5 114 2.5 10 12.54 4 11 13.54 6 12 14.54 10 14.5 174 16 17 19.54 25 21 244 35 23 264 50 27 304 70 31 34.54 95 35.5 39.55 1.5 9.5 125 2.5 10.5 137 1.5 10.5 13
10 1.5 13.5 1612 1.5 14 1714 1.5 14.5 17.516 1.5 15.5 18.519 1.5 16.5 19.524 1.5 19.5 22.5
25
290
500630
MMLE602-MPRX52MMLE602-MPRX53
330375440
4445165225205
1300172523103275
245345535795
4140130180
MMLE602-MPRX50MMLE602-MPRX51
MMLE602-MPRX46MMLE602-MPRX47MMLE602-MPRX48MMLE602-MPRX49
MMLE602-MPRX42MMLE602-MPRX43MMLE602-MPRX44MMLE602-MPRX45
MMLE602-MPRX39
Product No.
MMLE602-MPRX40MMLE602-MPRX41
MMLE602-MPRX38
MMLE602-MPRX33MMLE602-MPRX34MMLE602-MPRX35
MPRX 0.6/1 kV
Core No. Outer Diameter Approx.Weightkg/km
MMLE602-MPRX36MMLE602-MPRX37
1.Conductor : Annealed Standard Copper,class2.2.Insulation : Mica Tape+XLPE(Cross-Linked Polyethylene)
26
*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)*Halogen Free cable materials ensure non corrosive and low toxic gases are emitted in case of fire.
*Fire resistant(IEC 60331)
*Especially suitable for installation on passenger ships.
for overall diameter of cable > 25mm 6*cable diameter
Applications*For fixed installations on ships and offshore-units at all locations below the upper metallic deck.
Gases toxicity
Minimum internal bending radiusfor overall diameter of cable < 25mm 4*cable diameter
No toxicity to IEC 60754-1
Flame Retardant
Smoke DensityFire Resistant
Gases corrosivity
Short-circuit max.conductor temperature 250 °CMinimum installation temperatureMinimum operating temperature
–10 °C
Test Voltage
Usage CharacteristicsMax.Conductor temperature in service 85 °C
3500 VMaximum operating voltage 1.2 kV
3.Outer sheath : Polyolefin
Electrical CharacteristicsRated Voltage Uo/U(Um) 0.6/1 kV
Standard : DIN&IEC
Design
IEC 60754-2IEC 61034IEC 60331-21IEC 60332-3 Cat. A–35 °C
MPRX331 0.6/1 kV
Halogen Free,Fire Resistant Power Cables without screen
Cross Section(mm2)
1 251 351 501 701 951 1202 1.52 2.52 42 62 102 162 253 1.53 2.53 43 63 103 163 253 353 503 703 953 1204 1.54 2.54 44 64 104 164 254 355 1.57 1.5
12 1.519 1.5
27
23
13.5151719
1821.511.512.5
12131416
22.2
13.514.5
12.513.515
17.519.521.511
25.52832
15
12.513.5
MMLE602-MPRX331-35MMLE602-MPRX331-36
35.539
16
2628
18.521
19.5
MMLE602-MPRX331-31MMLE602-MPRX331-32
MMLE602-MPRX331-37
12.5
1112
16.519.5
MMLE602-MPRX331-33MMLE602-MPRX331-34
MMLE602-MPRX331-27MMLE602-MPRX331-28MMLE602-MPRX331-29MMLE602-MPRX331-30
MMLE602-MPRX331-23MMLE602-MPRX331-24MMLE602-MPRX331-25MMLE602-MPRX331-26
23
11
25
13.516
18.5
1112.5
103532
15.519
29
MMLE602-MPRX331-09 10.5
MMLE602-MPRX331-17MMLE602-MPRX331-18
MMLE602-MPRX331-15MMLE602-MPRX331-16
13.5MMLE602-MPRX331-11MMLE602-MPRX331-12MMLE602-MPRX331-13
MMLE602-MPRX331-19
25
MMLE602-MPRX331-10 11.5
MMLE602-MPRX331-20MMLE602-MPRX331-21MMLE602-MPRX331-22
20.522.5
MMLE602-MPRX331-14
15
16.5
MMLE602-MPRX331-05 16.5MMLE602-MPRX331-06 18.5
MMLE602-MPRX331-08 9.5
910
MMLE602-MPRX331-01 10
14.5
MMLE602-MPRX331-02 11MMLE602-MPRX331-03 12.5
MMLE602-MPRX331-07 8.5
MMLE602-MPRX331-04
Product No. Core No. Outer Diameter Outer DiameterMax(mm)Min(mm)
MPRX331 0.6/1 kV
Communication cable with screen(armour)150/250V
1.Conductor : Annealed Standard Copper,class2.2.Insulation : EPR(Cross-linked Ethylene Propylene Rubber)3.Laying Up : Pair stranding(2 pair cable=quad stranding)4.Armour : Separator tape,bare copper braid5.Outer sheath : Cross-linked Polychloroprene Rubber
28
Standard : DIN 89159
Design
Usage Characteristics
Rated Voltage Uo/U(Um)Test Voltage
150/250V1500V
IEC 61034
Minimum installation temperatureMinimum operating temperature
YES6*cable Diameter
Applications*For fixed installations in communication,radio,control,data processing facilities on ship and offshore.
Minimum internal bending radius
IEC 60754-2Gases corrosivity
–10 °C
Electrical Characteristics
85 °C250 °CShort-circuit max.conductor temperature
Max.Conductor temperature in service
–35 °CIEC 60332-3 Cat. A
No toxicity to IEC 60754-1
Flame retardant
Electro magnetic interference resistance
*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)
Gases toxicity
Smoke Density
FMGCG 150/250V
Cross Section(mm2) Min(mm) Max(mm)
1 0.75 7.5 910 0.75 17.5 19.514 0.75 19.5 22.519 0.75 22 262 0.75 8.5 10
24 0.75 25 28.54 0.75 12 13.57 0.75 15 17
29
FMGCG 150/250V
MMLE602-FMGCG02MMLE602-FMGCG03
MMLE602-FMGCG01
Approx.Weightkg/km
MMLE602-FMGCG05
Product No. Pair No. Outer Diameter
120580740930MMLE602-FMGCG04
MMLE602-FMGCG07MMLE602-FMGCG06
MMLE602-FMGCG08
1701200290410
Halogen Free Communication cable with screen(armour)
1.Conductor : Annealed Standard Copper,class2.2.Insulation : HEPR(Cross-linked Ethylene Propylene Rubber)3.Laying Up : Pair stranding(2 pair cable=quad stranding)4.Armour : Separator tape,bare copper braid5.Outer sheath : Cross-linked Polychloroprene Rubber
30
Design
Standard : DIN89159
Electrical CharacteristicsRated Voltage Uo/U(Um) 150/250VTest Voltage 1500V
Usage CharacteristicsMax.Conductor temperature in service 85 °CShort-circuit max.conductor temperature250 °CMinimum installation temperature –10 °CMinimum operating temperature –35 °CFlame retardant IEC 60332-3 Cat. ASmoke Density IEC 61034Gases corrosivity IEC 60754-2Gases toxicity No toxicity to IEC 60754-1Electro magnetic interference resistanceYESMinimum internal bending radius 6*cable Diameter
Applications*For fixed installations in communication,radio,control,data processing facilities on ship and offshore.*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)*Halogen Free cable materials ensure non corrosive and low toxic gases emitted in case of fire.*Especially suitable for installation on passenger ships.
FMGCH 150/250V
Cross Section(mm2) Min(mm) Max(mm)
1 0.75 7.5 9.510 0.75 17.5 19.514 0.75 19.5 2219 0.75 22 252 0.75 8.5 10
24 0.75 25 284 0.75 11.5 13.57 0.75 15 17
31
FMGCH 150/250V
Product No. Pair No. Outer Diameter Approx.Weightkg/km
MMLE602-FMGCH06MMLE602-FMGCH07MMLE602-FMGCH08
MMLE602-FMGCH01MMLE602-FMGCH02MMLE602-FMGCH03MMLE602-FMGCH04
470610770
MMLE602-FMGCH05 130950230340
90
Halogen Free,Fire Resistant Communication cable with screen
1.Conductor : Annealed Standard Copper,class2.2.Insulation : HEPR(Cross-linked Ethylene Propylene Rubber)3.Laying Up : Pair stranding(2 pair cable=quad stranding)4.Armour : Separator tape,bare copper braid
32
Design
FMGCH-F 150/250V
Standard : DIN89159
5.Outer sheath :Polyolefin
Electrical CharacteristicsRated Voltage Uo/U(Um) 150/250VTest Voltage 1500V
Usage CharacteristicsMax.Conductor temperature in service 85 °CShort-circuit max.conductor temperature250 °CMinimum installation temperature –10 °CMinimum operating temperature –35 °CFlame retardant IEC 60332-3 Cat. A
Smoke Density IEC 61034Gases corrosivity IEC 60754-2Gases toxicity No toxicity to IEC 60754-1Electro magnetic interference resistanceYES
*Halogen Free cable materials ensure non corrosive and low toxic gases emitted in case of fire.*Especially suitable for installation on passenger ships.
Minimum internal bending radius 6*cable Diameter
Applications*For fixed installations in communication,radio,control,data processing facilities on ship and offshore.
Fire resistant IEC 60331-21
*Fire Resistant test(IEC 60331-21)*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)
Cross Section(mm2) Min(mm) Max(mm)
1 0.75 9.5 10.510 0.75 21 2314 0.75 27 2919 0.75 28 302 0.75 10 11
24 0.75 30 334 0.75 14.5 167 0.75 18.5 20.5
33
FMGCH-F 150/250V
MMLE602-FMGCH-F01
Product No. Pair No. Outer Diameter Approx.Weightkg/km
1501110270
MMLE602-FMGCH-F02MMLE602-FMGCH-F03MMLE602-FMGCH-F04MMLE602-FMGCH-F05
110570740930
400
MMLE602-FMGCH-F06MMLE602-FMGCH-F07MMLE602-FMGCH-F08
Halogen Free Communication cable with screen(armour)
1.Conductor : Annealed Standard Copper,class2.2.Insulation : XLPE(Cross-Linked Polyethylene)3.Laying Up : Pair stranding(2 pair cable=quad stranding)4.Armour : Separator tape,bare copper braid
34
Design
FMKHC 150/250V
Standard : DIN 89159
5.Outer sheath : Polyolefin
Electrical CharacteristicsRated Voltage Uo/U(Um) 150/250VTest Voltage 2000V
Usage CharacteristicsMax.Conductor temperature in service 90 °CShort-circuit max.conductor temperature250 °CMinimum installation temperature –10 °CMinimum operating temperature –35 °CFlame retardant IEC 60332-3 Cat. ASmoke Density IEC 61034Gases corrosivity IEC 60754-2Gases toxicity No toxicity to IEC 60754-1Electro magnetic interference resistanceYESMinimum internal bending radius 6*cable Diameter
Applications*For fixed installations in communication,radio,control,data processing facilities on ship and offshore.*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)*Halogen Free cable materials ensure non corrosive and low toxic gases emitted in case of fire.*Especially suitable for installation on passenger ships.
Cross Section(mm2) Min(mm) Max(mm)
1 0.75 7.5 810 0.75 18 20.614 0.75 20 22.519 0.75 23 25.52 0.75 8.5 9.8
24 0.75 26 28.84 0.75 11.5 147 0.75 14.5 17
35
FMKHC 150/250V
Product No. Pair No. Outer Diameter Approx.Weightkg/km
MMLE602-FMKHC01MMLE602-FMKHC02MMLE602-FMKHC03
90460610
MMLE602-FMKHC07MMLE602-FMKHC08
130920230330
750MMLE602-FMKHC04MMLE602-FMKHC05MMLE602-FMKHC06
Halogen Free,Fire Resistant Communication cable with screen
1.Conductor : Annealed Standard Copper,class2.
3.Laying Up : Pair stranding(2 pair cable=quad stranding)4.Armour : Separator tape,bare copper braid
36
FMKHC-F 150/250V
Design
Standard : DIN89159
5.Outer sheath : Polyolefin
2.Insulation : Mica+XLPE
Electrical CharacteristicsRated Voltage Uo/U(Um) 150/250VTest Voltage 1500V
Usage CharacteristicsMax.Conductor temperature in service 90 °CShort-circuit max.conductor temperature250 °CMinimum installation temperature –10 °CMinimum operating temperature –35 °CFlame retardant IEC 60332-3 Cat. AFire resistant IEC 60331-21Smoke Density IEC 61034Gases corrosivity IEC 60754-2Gases toxicity No toxicity to IEC 60754-1Electro magnetic interference resistanceYESMinimum internal bending radius 6*cable Diameter
Applications*For fixed installations in communication,radio,control,data processing facilities on ship and offshore.*The ship cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)*Fire Resistant test(IEC 60331-21)*Halogen Free cable materials ensure non corrosive and low toxic gases emitted in case of fire.*Especially suitable for installation on passenger ships.
Cross Section(mm2) Min(mm) Max(mm)
1 0.75 9 10.510 0.75 22.5 2514 0.75 26 2919 0.75 29.5 32.52 0.75 10.5 12.5
24 0.75 33 36.54 0.75 16 18.57 0.75 18 20
37
FMKHC-F 150/250V
MMLE602-FMKHC-F02 470
Product No. Pair No. Outer Diameter Approx.Weightkg/km
MMLE602-FMKHC-F01 90
MMLE602-FMKHC-F08 340
MMLE602-FMKHC-F05 130MMLE602-FMKHC-F06 920MMLE602-FMKHC-F07 230
MMLE602-FMKHC-F03 610MMLE602-FMKHC-F04 770