dimensional data for piping (ddp) - spi-ltuf.orgspi-ltuf.org/20171114/ddp presentation.pdf ·...

23
© 2014 Fluor. All Rights Reserved. Dimensional Data for Piping (DDP) By L. Webster

Upload: trinhkiet

Post on 28-Mar-2018

233 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

© 2014 Fluor. All Rights Reserved.

Dimensional Data for Piping(DDP)

By L. Webster

Page 2: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Special Thanks

♦ The Fisher FIRST & DDP work process slides are original from a presentation prepared by:– John Dressel, Fluor– Keith Herbsleb, Emerson (Puffer Sweiven)– Janelle Prusha, Emerson

2

Page 3: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Overview

♦ The Basics– Setup– DDP Groups– Working Data Browser

♦ Next Evolution– SP3D Groups– Re-use Data - Default Data Browser

♦ Hexagon/Fisher (Fisher FIRST 2.0)– Optimizing Valve Sizing Work Processes

3

Page 4: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Setup

♦ Domain Administrator– Click Add-Ins > Import DDP

Library Data > From SmartPlant 3D

– Connect– Import

♦ Imports– DDP Groups– Piping End Connection Types– Piping Classes

4

Page 5: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

5

Original DDP Groups

♦ Approx. 100 Different Groups♦ Original DDP Groups didn’t have

values for rotation– Change groups to change rotation

♦ Lose dimensional data when groups are changed

Page 6: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Enter Data

♦ Dimensional Data Sheet– Tag by Tag

6

Page 7: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Enter Data - Working Data Browser

♦ Multiple Tags♦ Set the status - Preliminary / Design / Certified

7

Page 8: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

8

♦ The DDP data is Published to SmartPlant Foundation (SPF) for S3D to Retrieve into the 3D Model with Tag Numbers

Publish

Page 9: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

♦ The Piping Designer selects the Valve Tag and places the Fully Dimensioned Valve into the Model

♦ The Instrument Designer Checks the Instrument Connection, Maintenance Access and Orientation of the Valve

Valve isPlaced

The TagIs Select

Retrieve & Place in S3D

Page 10: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

10

Next Evolution

♦ 10 New S3D Groups cover 90% of the of the PDS groups

♦ S3D Groups with rotation♦ PDS groups still available for

S3D as well

Page 11: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Re-Use Data - Default Data Browser

♦ Fluor has created a Global SPI DDP Database for loading Default Data– Uploaded with Mfr & Model dimensions from previously purchased instruments– Copy data from Default Browser to Working Data for matching Mfr, Model and

size

11

Page 12: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

12

♦ Fisher FIRST 2.0 Transfer control valve spec sheets and envelope dimensions as DATA rather than graphic PDF files

How can DDP be easier, faster, and more reliably?

Process Conditions Specification Sheet Sizing Calculations Piping 3D Model

Page 13: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

The FF to SPI Manual Work Process

Export Valve Spec Sheet

from SPI

Input Selection data

into SPI

Input SPI Spec Data

into FF

Retrieve DDP datainto S3D

EPC I&CEngineer

(SPI)

Fisher Sales Office - Puffer-Sweiven

(FF)

EPC Piping and InstrumentDesigners

(S3D)

Complete SPIControl Valve Spec Sheet

Spec Sheet with Process

Data

Valve Spec Sheet Selection

Data

Create SPI Valve Spec Sheet with

Process Data andDefine DDP Group

Export ModelNumber and

Certified Data

Publish DDP data to SPF

Size and Select Control Valve with FF

Associate Tag to DDP Group

Valve CertifiedDimensional Data Sheet

Input Certified

Dimensional Data into

S3D

Input Preliminary DDP Dimensional Data

Manual Data Input

IssueValve

Purchase Order

Control valve shape placed into Piping Design Model

SmartPlant Foundation

(SPF)

Update Control valve shape from Design Basis

Page 14: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Fisher Valve Sizing and Selection

14

♦ Fisher FIRST - Valve Sizing and Selection and Pricing software made Fisher a pioneer in Valve sizing automation

♦ Fisher FirstVue - an extension of Fisher FIRST was used by EPCs for Sizing calculations and Selection of Valves

♦ Fisher Specification Manager (FSM) gave Fisher FirstVue an interface into SPI with DDP information for use by EPCs

♦ Fisher FIRST 2.0 merged the functionality of Fisher FIRST for Valve Sizing and Selection and Pricing with the Specification Manager’s interface to SPI and DDP data

Page 15: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

15

The FF2 to SPI Interface Work Process

Export Valve Spec Sheet

from SPI

Import into SPI with FF2 link File

Import SPI Data into

FF2

Retrieve Tagand DDP data

design into S3D

EPC I&CEngineer

(SPI)

Fisher Sales Office - Puffer-Sweiven

(FF2)

EPCPiping

Designer

(S3D)

Complete Control Valve Spec Sheet

CSV file withvalve and

process data

CSV file withValve Spec

Sheet and DDP Data

Create SPI Valve Spec Sheet with

Process Data

Export Spec & Link File for FF2

and DDP Data

Publish Tag and DDP data to SPF

Size and Select Control Valve in FF2

Control valve shape placed

into Piping Design Model

IssueValve

Purchase Order

SmartPlant Foundation

(SPF)

Associate Tag to DDP Group

Input Preliminary DDP Dimensional Data

Page 16: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

SPI SPEC FORM 90

16

Fisher worked with Intergraph to create SPI Form 90, the standard

control valve spec sheet for Fisher products

Page 17: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Form 90 or Custom Form

17

♦ Typically companies have custom forms in SPI♦ The new FF2 link mapping process can handle either…

– SPI Form 90 Standard Fisher control valve specification sheet– Custom valve spec sheet form in SPI with mapped link file

or

PI)

FisherFIRST 2

StandardFF2-to-SPIData File

SPI Import Module

Fisher importmap ‘Link File’

custom import map ‘Link File’

Form 90 -Fisher Spec Sheet Form

Custom valve Spec Sheet Form

or

Page 18: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

18

FF2 Spec and DDP Functions

♦ The .CSV data file includes both the Control Valve Spec Sheet and DDP data

♦ Import link file is provided for SPI Import Module ♦ The SPI user has the option to import all the Spec Data or Just the

Size, Cv and Catalog numbers as needed

Approx. 400 columns of Control Valve Spec Sheet data

Approx. 40 columns of associated Dimensional Data for Piping (DDP)

Page 19: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Fisher Spec Sheet Data …

AND

Dimensions Data for Piping

Before importing Fisher Spec Data and DDP data into SPI the user can do a comparison to see what data fields had changed

SPI Imports FF2 Spec Data and DDP Data using link files

FF2 Import

Page 20: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

20

Many new “Standard” shapes have been defined in SPI and S3D specifically for Fisher control valves

FF2 DDP Groups

Page 21: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

21

Dimensional Data for Piping

Example of Intergraph 3D shape used for Fisher

DDP

♦ In S3D the new DDP Shapes closely resemble the actual Fisher Valves

Control Valve Photo

Page 22: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

22

Future Enhancements

♦ HEXAGONPPM Intergraph recently announced the development of Vendor Application Programming Interfaces (APIs)

♦ Future releases of Fisher FIRST 2.0 will be able to Read and Write data directly from and to SmartPlant Instrumentation

♦ The APIs will eliminate the use of .CSV files to Export and Import Data

♦ Data will be Published and Retrieved through the APIs and have Management of Change and Data Validation

SPI

FF2

API

Page 23: Dimensional Data for Piping (DDP) - spi-ltuf.orgspi-ltuf.org/20171114/DDP Presentation.pdf · ♦The Piping Designer selects the Valve Tag and places the Fully Dimensioned ... ♦Fluor

Questions

23