dimension and installation guide gas cooktop
TRANSCRIPT
DIMENSION AND INSTALLATION GUIDE
510mm
58mm(built-in height)
860mm
A minimumB minimum
830mm470mm
Gas supply connection
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL95/795 Current as at Jul 2007
Note: Electrical connectionRequires 240V 10AMP power outlet
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
These models are supplied with 10Amp plug and lead
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
gas cooktop
MODELS: GHL95, GHL795
DIMENSION AND INSTALLATION GUIDE
PHL222
320mm505mm
40mm(built-in height)
600mm
303mm
485mm
50mm min
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL222 Current as at Jul 2007
Note: Connection type - hardwired Maximum power load 3.0kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.
Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
cooktop dimensions
building-in cut-out dimensions
electric ceramic cooktop
MODEL: PHL222
DIMENSION AND INSTALLATION GUIDE
600mm 535mm
58mm(built-in height)
600mm
50mm min
490mm
570mm
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL255 Current as at Jul 2007
cooktop dimensions
building-in cut-out dimensions
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles
Note: Connection type requires 240V/20A power outlet
electric solid hotplate cooktop
MODEL: PHL255
DIMENSION AND INSTALLATION GUIDE
600mm
50mm min
485mm
588mm
615mm 515mm
40mm(built-in height)
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL284 Current as at Jul 2007
Note: Connection type - hardwired Maximum power load 6.0kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.
Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
cooktop dimensions
building-in cut-out dimensions
electric ceramic cooktop
MODEL: PHL284
DIMENSION AND INSTALLATION GUIDE
605mm 505mm
40mm(built-in height)
600mm
50mm min
485mm
588mm
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL285 Current as at Jul 2007
Note: Connection type - hardwired Maximum power load 6.4kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles
Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
cooktop dimensions
building-in cut-out dimensions
electric ceramic cooktop
MODEL: PHL285
DIMENSION AND INSTALLATION GUIDE
605mm
95mm
505mm
505mm
40mm(built-in height)
65mm(built-in height)
600mm
50mm min
485mm
588mm
80mm120mm max.
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL564 Current as at Jul 2007
cooktop dimensions
building-in cut-out dimensions
Note: Connection type - hardwired Maximum power load 6.4kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles
Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
control panel dimensions
electric ceramic cooktop
MODEL: PHL564
DIMENSION AND INSTALLATION GUIDE
870mm406mm
100mm(built-in height)
600mm
362mm
825mm
50mm min
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL365 Current as at Jul 2007
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles
cooktop dimensions
building-in cut-out dimensions
Note: Connection type requires 240V/20A power outlet
electric solid hotplate cooktop
MODEL: PHL365
DIMENSION AND INSTALLATION GUIDE
615mm 515mm
40mm(built-in height)
600mm
50mm min
485mm
588mm
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL668 Current as at Jul 2007
cooktop dimensions
building-in cut-out dimensions
Note: Connection type - hardwired Maximum power load 5.9kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles
Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
electric ceramic cooktop
MODEL: PHL668
DIMENSION AND INSTALLATION GUIDE
600mm
50mm min
485mm
588mm
615mm 515mm
40mm(built-in height)
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL768 Current as at Jul 2007
cooktop dimensions
building-in cut-out dimensions
Note: Connection type - hardwired Maximum power load 6.5kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles
Note: If a barrier is not required, a minimum gap of 30mm is needed under the cooktop.
Note: If the base of the cooktop can be touched from inside a cupboard or drawer, a barrier MUST be installed to prevent contact. The material for the barrier must be capable of sustaining heat up to 70oC. Make sure the barrier is at least 50mm and not more than 75mm below the base of the cooktop. The barrier is to have ventilation holes evenly spaced in the one of the following configurations: 25 x 25mm diameter, 15 x 35mm diameter or 6 x 50mm diameter.
electric ceramic cooktop
MODEL: PHL768
DIMENSION AND INSTALLATION GUIDE
930mm440mm
50mm(built-in height)
600mm
50mm min
360mm
870mm
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL394 Current as at Jul 2007
Note: Connection type - hardwired Maximum power load 6.2kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.
cooktop dimensions
building-in cut-out dimensions
electric ceramic cooktop
MODEL: PHM394U
DIMENSION AND INSTALLATION GUIDE
600mm
50mm min
462mm
880mm
896mm505mm
50mm(built-in height)
© 2007 Electrolux Home Products Pty Ltd
WDIMPHL798 Current as at Jul 2007
cooktop dimensions
building-in cut-out dimensions
Note: Connection type - hardwired Maximum power load 6.5kW
Note: Any walls surrounding the cooktop are to be heat resistant up to 90oC, up to 150mm high eg. ceramic tiles.
electric ceramic cooktop
MODEL: PHM798
DIMENSION AND INSTALLATION GUIDE
535mm
58mm(built-in height)
600mm
A minimum
B minimum
570mm
490mm
Gas supply connection
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
Note: Electrical connectionGHL12 models require a 240V/10A power outlet.GHL11 models do not require an electrical connection.
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL11/12 Current as at Jul 2007
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
GHL12 is supplied with 10Amp plug and lead
gas cooktop
MODELS: GHL11, GHL12
DIMENSION AND INSTALLATION GUIDE
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
535mm
58mm(built-in height)
600mm
A minimum
B minimum
570mm
490mm
Gas supply connection
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL16/17/765 Current as at Jul 2007
Note: Electrical connectionRequires 240V 10AMP power outlet
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
These models are supplied with 10Amp plug and lead
gas cooktop
MODELS: GHL16, GHL17, GHL765
DIMENSION AND INSTALLATION GUIDE
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
542mm
58mm(built-in height)
600mm
A minimum
B minimum
570mm
490mm
Gas supply connection
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL26 Current as at Jul 2007
Note: Electrical connectionRequires 240V 10AMP power outlet
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
These models are supplied with 10Amp plug and lead
gas cooktop
MODEL: GHL26
DIMENSION AND INSTALLATION GUIDE
520mm
58mm(built-in height)
890mm
A minimumB minimum
830mm470mm
Gas supply connection
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL46 Current as at Jul 2007
Note: Electrical connectionRequires 240V 10AMP power outlet
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
These models are supplied with 10Amp plug and lead
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
gas cooktop
MODEL: GHL46
DIMENSION AND INSTALLATION GUIDE
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
510mm
58mm(built-in height)
860mm
A minimumB minimum
830mm470mm
Gas supply connection
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL90 Current as at Jul 2007
Note: Electrical connectionNot required
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
gas cooktop
MODEL: GHL90
DIMENSION AND INSTALLATION GUIDE
* Minimum height of non-combustible surface is 150mm
NOTE: All appliances must be installed to Australian Standard AS5601
minimum distance to combustible vertical surface
minimum distance to non-combustible vertical surface*
A 135mm 50mm
B 120mm 50mm
58mm(built-in height)
510mm
860mm
A minimumB minimum
830mm470mm
Gas supply connection
© 2007 Electrolux Home Products Pty Ltd
WDIMGHL92 Current as at Jul 2007
Note: Electrical connectionRequires 240V 10AMP power outlet
cooktop dimensions
building-in cut-out dimensions
Walls around cooktop must be heat resistant for temperatures up to 90oC to a height of 150mm above the bench top.
These models are supplied with 10Amp plug and lead
gas cooktop
MODEL: GHL92