Simple fi eld devices such as barcode readers, identifi cation system, valve islands or I/O blocks
will require a connection to Fieldbus or Real-Time Ethernet systems. Since these devices do
not have a high data throughput, the netIC uses a serial connection such as UART and SPI as host interface.
The netIC is a complete ‘Single Chip Module’ in the compact dimensions of a Dual-In-Line (DIL) 32 pin plugin
module. It is based on the network controller netX and contains all components of a Fieldbus or Real-Time
Ethernet interface with integrated 2-port switch and hub. With the netX technology the whole spectrum of relevant
Fieldbus and Real-Time Ethernet systems is covered by loadable Firmware with one netIC. The user data
is transferred with simple read-write commands to the application via the above mentioned serial interfaces. As
serial protocol the well known Modbus RTU protocol is used.
Alternatively conventional shifting registers can be controlled via a synchronous serial interface
so no additional processor for a simple I/O-Device is required.
netICDIL-32 Communication-IC with Modbus Host Interface
Slave solution for simple field devices
Real-Time Ethernet
Fieldbus
Compact communication module for cost-efficient field devices
Fieldbus and Real-Time Ethernet as Slave
Modbus RTU protocol via SPI or UART to the host
One hardware for all Real-Time Ethernet protocols
Firmware update via integrated Webserver
One design for all networks due to consistent interfaces
Real-Time Ethernet
Compact communication module for cost-efficient field devices
DIL-32 Communication-IC with Modbus Host Interface
Direct I/O data transfer
Integrated Webserver
Same Function - Same API - Same Tools
The Hilscher Platform Strategy provides the whole range of
communication solutions to the user – from standardized PC
cards up to the integration of the multi-protocol chip netX. All
solutions – whether Master or Slave – have the same interface
to the application and use the same tools.
After single integration of the application interface the change
to a different hardware format or a different physical host
interface is a purely hardware optimization process without
fundamental changes of the software structure.
netIC allows the direct connection of I/O data via con-
ventional shift registers. This is beneficial for compact
and simple field devices, since a product design can
be realized without a host processor. The shifting
direction as well as the refresh cycle of the data can
easily be configured using a graphical tool.
The major Real-Time Ethernet protocols always
include a Webserver and FTP server. This allows
the user an easy and central firmware update as well
as IP configuration. Furthermore I/O data from the
Modbus registers can be dynamically displayed and
written. User and password administration will be
done during the installation process using a graphi-
cal configuration tool.
Real-Time Ethernet & Fieldbus protocols
Modbus Host Interface
As specialist for industrial communication
Hilscher offers the largest selection of proto-
cols used in the factory automation. Besides
traditional Fieldbus all major Real-Time
Ethernet protocols are available.
For a quick and easy integration the Hilscher netIC uses the well-
known Modbus protocol as application interface. Thereby it can
either be deployed as Modbus RTU Slave or as Modbus RTU Master
on the serial bus – or netIC gets connected as SPI slave device.
Commissioning and configuration of netIC
is done quick and easy by an intuitive confi-
guration tool. With this tool the user defines
the behaviour of the Fieldbus, the Modbus
host interface, the shift registers as well
as the basic settings of the Web and FTP
Server.
Graphical configuration tool
The major Real-Time Ethernet protocols always
include a Webserver and FTP server. This allows
the user an easy and central firmware update as well
as IP configuration. Furthermore I/O data from the
Modbus registers can be dynamically displayed and
written. User and password administration will be
done during the installation process using a graphi-
cal configuration tool.
NIC 10-CCS
NIC 50-COS
NIC 50-DNS
NIC 50-RE
NIC 50-DPS
NIC 50-REFO
Slave
Slave Slave
Slave
PCI
PCIe
PCIe
DPM SPI SP
I
DPM
UART
SPI
DPM
SPI
DPMSPI
MAC
(Modbus R
TU)
(Modbus RTU)
M
aster
M
aste
r
S
lave
Master
Slave
netX
Core
Tech
nolo
gy
sam
e A
PI
-
same Tools - sam
e Driver -
Technical Data / Product Overview
HeadquartersGermanyHilscher Gesellschaft fürSystemautomation mbHRheinstrasse 1565795 HattersheimPhone: +49 (0) 6190 9907-0 Fax: +49 (0) 6190 9907-50E-Mail: [email protected]: www.hilscher.com
JapanHilscher Japan KKTokyo, 160-0022Phone: +81 (0) 3-5362-0521E-Mail: [email protected]
KoreaHilscher Korea Inc. Seongnam, Gyeonggi, 463-400Phone: +82 (0) 31-789-3715E-Mail: [email protected]
SwitzerlandHilscher Swiss GmbH 4500 SolothurnPhone: +41 (0) 32 623 6633E-Mail: [email protected]
USAHilscher North America, Inc. Lisle, IL 60532Phone: +1 630-505-5301E-Mail: [email protected]
IndiaHilscher India Pvt. Ltd.Pune, Delhi, MumbaiPhone: +91 11 26915430E-Mail: [email protected]
ItalyHilscher Italia S.r.l.20090 Vimodrone (MI)Phone: +39 02 25007068E-Mail: [email protected]
SubsidiariesChinaHilscher Systemautomation(Shanghai) Co. Ltd.200010 ShanghaiPhone: +86 (0) 21-6355-5161E-Mail: [email protected] FranceHilscher France S.a.r.l.69500 BronPhone: +33 (0) 4 72 37 98 40E-Mail: [email protected] Distributors
More information at www.hilscher.com 10/2
014
GB
-
-
netIC 10
NIC 10
Art
icle
Mod
bus
via
UA
RT
Mod
bus
via
SPI
netIC 50
NIC 50
netIC Evaluationboard
NICEB-RE
netIC Evaluationboard
NICEB-FB
-
- - - - - - -
-
Parameter Value
Processor netX 10 / netX 50
Memory 8 MB SDRAM
Displays System LED
Serial Interfaces Diagnostic/Confi guration:
UART (RXD, TXD)
Host Interface:
Modbus RTU via UART (Master/Slave)
max. 115.2 KBit/s
Modbus RTU via SPI (Slave)
max. 102 KBit/s
Serial I/O Shiftregister Inputs: max. 256 x 8 Bit shift register
Interface Outputs: max. 256 x 8 Bit shift register
max. 5 MBit/s
Tec
hn
ical
Dat
a
Parameter Value
Communication- 2x Ethernet 100 BASE-TX
interface CANopen / DeviceNet / CC-Link / Profi bus
Operating voltage +3.3 V / typ 400 mA
Operating temperature - 20 ... +70 °C (RE with heatsink)
Dimensions (L x W x H) 42 x 21 x 14,2 mm (without Pins)
- with heatsink- 42 x 21 x 17,2 mm (with Pins)
Emission EN55011 class A
Immunity Surge - IEC 61000-4-5
Burst - IEC 61000-4-4
ESD - IEC 61000-4-2
CE Yes
RoHS Yes
Tec
hn
ical
Dat
a
NIC 10-CCS/CCS 1542.740 netIC CC-Link Slave InterfaceNIC 50-COS/COS 1541.540 netIC CANopen Slave InterfaceNIC 50-DNS/DNS 1541.520 netIC DeviceNet Slave InterfaceNIC 50-DPS/DPS 1541.420 netIC PROFIBUS-DP Slave InterfaceNIC 50-RE/ECS 1541.100/ECS netIC EtherCAT Slave InterfaceNIC 50-RE/EIS 1541.100/EIS netIC EtherNet/IP Adapter InterfaceNIC 50-RE/PLS 1541.100/PLS netIC POWERLINK Controlled Node InterfaceNIC 50-RE/OMB 1541.100/OMB netIC Modbus TCP Client/Server InterfaceNIC 50-RE/PNS 1541.100/PNS netIC PROFINET IO RT Device InterfaceNIC 50-REFO/PNS 1541.110/PNS netIC PROFINET IO RT Device Fiber OpticNIC 50-RE/S3S 1541.100/S3S netIC sercos Slave Interface (not synchonous)NIC 50-RE/VRS 1541.100/VRS netIC VARAN Client InterfaceNICEB-RE 1540.000 netIC Evaluationboard for Real-Time Ethernet*NICEB-FB 1541.000 netIC Evaluationboard for FieldbusNICEB-REFO 1540.020 netIC Evaluationboard Fiber OpticNICEB-CONKIT 1541.001 netIC Evaluationboard Fieldbus connector kit
Ove
rvie
w
Article Description Article Number Article
*Note: To enhance NICEB-RE toNICEB-FB a Connector-Kit(Article number: 1541.001) isavailable and can simply beordered afterwards.
Note: All technical data are preliminary and can be altered without notice.
- - - - - - -
- - -
- - -