Page 1: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

مجهز دیجیتالی آالرم سیستمخطا ثبات به

Digital Alarm Annunciator with event recorder

Page 2: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Description Alarm annunciator for use with all types

of digital inputs that provide a voltage signal .

Features 20 digital inputs that can be classified in 4 groups with separate output contacts .

Also inputs 1&2 have the facility to operate as trip circuit supervision relay.

Page 3: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Characteristics 20 inputs for use with digital signals. Each input accepts voltage signals. Programmable 16 character LCD text for each

alarm. Current alarms are displayed and scrolled up on

2x16 LCD display. Alarm delay programmable within the range of 50

msec. to 600 seconds in steps of 50 msec. for each input separately.

20 LEDs with indication of new and acknowledged alarms.

Page 4: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Characteristics (continued)

Alarm inputs can be classified in 1 to 4 groups with

separate voltage commons and separate output relays. In each group if there is many alarms in same time, the

blinking frequency of the first alarm is different with

others. Inputs 1&2 can be defined as inputs for trip circuit

supervision as a part of system operation with separate

voltage references. LCD provides real time input sensing. SD memory of 2G bytes for event logs with date & time

(unlimited).

Page 5: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Characteristics (continued)

PC based programming and reading of event logs,

through USB link. In addition to memory log , events can be recorded

in MODBUS-RTU protocol via RS485. RS485 interface for field-bus communication. Remote programming facility. Standard MODBUS-RTU protocol.

Page 6: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Function

The MAL-20C features a total of 20 programmable alarms. Multiple alarms can be assigned to the same input group to provide annunciation at different input selectable delays. An alarm is annunciated when the input passes above or below a fixed level.

Page 7: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Function ( continued)

Annunciation of an alarm can be displayed on any one of the 20 LEDs located on the front plate. Each LED will indicate new alarms with flashing light and acknowledged alarms with steady light. The user can acknowledge all new alarms by pressing the “Ack” key. If the alarm input is removed, it can be reseted by “RST” key.

Page 8: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Function ( continued)

The front plate includes an illuminated LCD display with 2 lines of 16 characters.

The LCD provides the user with a 16 character alarm description.

Page 9: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Function (continued)

The system can operate as an event recorder for it’s inputs.

During event recording or data transfer, the alarms can be reported by their description or their number.

Page 10: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Function (continued)

Inputs 1 and 2, and output relay1 can be assigned to be the inputs and output for trip circuit supervision application.

Page 11: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Connection

The rear and front of the MAL20C annunciator is illustrated here.

The power supply plug-in connector of the MAL20C includes 2 terminals, one for +60 to 180V DC and one GND reference.

The MAL20C includes two standard interfaces for serial data communication. The RS485 is intended for long

distance bus communication between multiple units.

The USB port for alarm setting or data collection by a laptop or computer .

Page 12: Digital Alarm Annunciator with event recorder. Description Alarm annunciator for use with all types of digital inputs that provide a voltage signal. Features

Connection rear view