diagnostic cardiology - medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf ·...

16
DIAGNOSTIC CARDIOLOGY For Your Procedural Needs Manufactured to the Highest Standards, Customised to Your Specific Needs

Upload: vutu

Post on 18-Mar-2018

229 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

DIAGNOSTIC CARDIOLOGYFor Your Procedural Needs

Manufactured to the Highest Standards,Customised to Your Specific Needs

Page 2: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

The items contained within this brochure are perfect for including in a procedure pack. Medline as a worldwide leader in Sterile Procedure Packs, are committed to quality. Medline have been providing surgical packs to facilities for over 20 years, and produce thousands of packs every day. The importance of quality cannot be overstated, in fact, we have zero tolerance for errors. Globally, we have over 300 highly trained quality assurance specialists directing all quality-related functions. The team includes chemists, microbiologists, statisticians, RNs and engineers. Count on your packs always containing exactly what you ordered: •Therightcomponents •Correctplacementwithinthepack •Consistent–accurate,eachandeverytime Our accuracy comes from state-of-the-art IT systems that help us to plan production, assemble sets and manage inventories. Procedure packs are assembled in dedicated clean rooms and undergo a validated Ethylene Oxide (EtO) sterilisation process. High quality and great service are the cornerstones of our success as a world-leading pack provider.

MEDLINE PROCEDURE PACKS

2

Page 3: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

MEDLINE PROCEDURE PACKS FLUID MANAGEMENT PRODUCTS

Manifolds Stopcocks SafetyDevices

Angiography Control Syringes

Closed-WasteManagement

High-PressureSyringes

Cath Lab Speciality Surgical Drapes

AngiographyNeedles

High Pressure Tubing

Fluid Administration Sets

3

Page 4: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Manifolds

Medline offers a variety of transducer manifold kits in configurations to meet your specific needs.

• Easy to use

• Smooth turning handles provide the feel that your clinicians are accustomed to

• Clearly identified on and off options

• Requires minimal stopcock manipulations

Non Sterile Code Description

CC99880 Transducer Manifold 3-Port Right Hand On

CC99885 Transducer Manifold 3-Port Right Hand Off

CC99884 Transducer Manifold 3-Port Left Hand On

CC99883 Transducer Manifold 3-Port Left Hand Off

CC99880

4

Page 5: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

CC91628

CC90127

CC91627

Stopcocks

• Efficient on/off valve can be used in a variety of settings

• Smooth rotation

• 1-, 2- and 3-way body style, right facing

• Available in low and high-pressure capacity

• Easy to differentiate pressure with colour coding:

white for standard

red for medium

blue for high pressure

Non Sterile Code Description

CC90126 Low Pressure, Swivel Lock Luer, 45PSI Rating, Off

CC91627 Low Pressure, Swivel Lock Luer, 45PSI Rating, On

CC91628 Medium Pressure, Rotating Adapter, 500PSI Rating, Off

CC90127 Medium Pressure, Rotating Adapter 500PSI, On

CC91629 High Pressure, Rotating Adapter 1050PSI, Off

CC90128 High Pressure, Rotating Adapter 1050PSI, On

CC90126

CC91629

CC90128

5

Page 6: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Safety Devices

• Medline’s guidewire bowl has five tabs to ensure that the guidewire stays in place

• Medline’s needle nest allows for a safe and secure place for needle storage

• Safety - VortexTM minimises the risk of exposure to healthcare professionals and allows for a safe clean way to dispose of liquid waste

• The pad solidifies, eliminating the need to transport medical waste in liquid form

• Self-contained system with a lid that seals tight to hold bio-hazardous waste

• 500ml fluid waste bowl

Non Sterile Code Description Sterile Code

96360 Guidewire Bowl, 2500mL -

35862 Needle Nest NDLNESTCE

95666 Basin, Safety Splash with Pad GSSPLASH1CE

96360

35862

95666

6

Page 7: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Angiography Control Syringes

• Easy visualisation of air bubbles with clear polycarbonate design

• Requires less force and provides smoother injections and aspirations with superior barrel design

• More secure catheter connection with rotating adapter

Non Sterile Code Description

CC81015 10mL Control Syringe with Rotating Male Luer Lock

CC81016 12mL Control Syringe with Rotating Male Luer Lock

RotatiNg tip

CC81015

CC81016

7

Page 8: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

CC90516

High Pressure Tubing

• Strong flexible braided and non braided options, withstands 1200PSI

• Transparent for visibility

• Available with and without a rotating adapter

• Sturdy PVC material

Non Sterile Code Description

CC93059 Non-braided 25.4cm (10”) Rotating Luer Lock

CC93060 Non-braided 51.2cm (20”) Fixed Luer Lock

CC93062 Non-braided 76.2cm (30”) Fixed Luer Lock

CC93064 Non-braided 121.9cm (48”) Fixed Luer Lock

CC93065 Non-braided 121.9cm (48”) Rotating Luer Lock

CC93066 Non-braided 152.4cm (60”) Fixed Luer Lock

CC90516 Braided 76.2cm (30”) Rotating Luer Lock

CC90521 Braided 182.9cm (72”) Fixed Luer Lock

CC90522 Braided 182.9cm (72”) Rotating Luer Lock

*If there is a configuration that you prefer which is not listed, please speak to your local representative to source an alternative within a greater range.

FiXED LUER LoCK RotatiNg LUER LoCK

8

Page 9: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Medline has an extensive range of fluid administration sets and fluid transfer connectors to complement our Diagnostic Cardiology range. These meet the majority of your clinical needs, are DEHP free and available with a drip chamber.

Non Sterile Code Description

CC35004 182.9cm (72”) Roller Clamp, No Vent / No Filter, Male Luer Lock

CC92526 182.9cm (72”) Chamber, Roller Clamp, No Vent / Filter Tip, Male Luer Lock

CC35003 182.9cm (72”) Roller Clamp, Vented Large Bore Spike, Male Luer Lock

*If there is a configuration that you prefer which is not listed, please speak to your local representative to source an alternative within a greater range.

Fluid Administration Sets

9

Page 10: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Medline waste bags minimise splashing and limit the potential for exposure to medical waste in the diagnostic cardiolgy field.

Non Sterile Code Description

48900 Single Spike Waste Bag, 1500mL

83493 Dual Spike Waste Bag, 1500mL

*If there is a configuration that you prefer which is not listed, please speak to your local representative to source an alternative within a greater range.

Closed-System WasteManagement

83493

10

Page 11: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Manufactured to withstand the highest pressures, Medline syringes are intended for use specifically in the cardiovascular environment.

Customisable • Choose from a variety of sizes and barrel colours to meet your specific needs

• Additional colours and sizes available for use inside custom packs

Durable • Polycarbonate withstands the high pressure ratings in the cath lab

Non Sterile Code Description

83562 10mL, Red**

**Available in other sizes and colours, please speak to your local representative.

High-Pressure Syringes

83562

11

Page 12: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

84880 83499 84881 89331

• Trouble-free insertion of guide wires with the luer hub

• Needle points feature a non-coring ‘B’ arterial bevel

• Designed for single-wall arterial percutaneous puncture

Non Sterile Code Description

84880 Needle, 18 Gauge, 2.75”, with Base

83499 Needle, 18 Gauge, 2.75”, No Base

84881 Needle, 19 Gauge, 2.75”, No Base

89331 Needle, 20 Gauge, 2.75”, No Base

Angiography Needles

12

Page 13: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Medline offers a variety of drape innovations to help you increase the efficiency of your cath lab while improving the patient experience such as windows, Zip-StripTM and procedure specific speciality drapes.

Please discuss these options with your local representative.

Cath Lab SpecialitySurgical Drapes

Zip StRiptM Zip StRiptM

SpECiaLtY DRapES

WiNDoWS

13

Page 14: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

14

Notes

Page 15: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

15

Notes

Page 16: DIAGNOSTIC CARDIOLOGY - Medlineau.medline.com/media/aumedline/smartchoice/cathlab-brochure.pdf · Manifolds Stopcocks Safety Devices Angiography Control Syringes Closed-Waste Management

Medline Australia6 Coronation AvenueKings Park NSW 2148Phone: 1800 110 511Web: medline.com/au

©2014 Medline Industries, Inc. Medline is a registered trademark of Medline Industries, Inc. One Medline Place, Mundelein, IL 60060. IP085/Feb14/v1