dh21ka trouble shooting
DESCRIPTION
doazarTRANSCRIPT
-
TROUBLESHOOTING
ERROR CODE DH21KA (WORK EQUIPMENT PUMP OIL PRESSURE SENSOR:
DISCONNECTION (KA))
ERROR CODE DH21KA (WORK EQUIPMENT PUMP OIL PRESSURE SENSOR:DISCONNECTION (KA))
Circuit diagram related to work equipment pump oil pressure sensor
Action code Error codeTrouble
Work equipment pump oil pressure sensor: Disconnection (KA)
(Transmission controller system)E01 DH21KA
Contents of
trouble Signal voltage of work equipment pump oil pressure sensor circuit is below 0.5V.
Action of
controller Does not take any particular action.
Problem that
appears on
machine
Work equipment pump oil pressure cannot be monitored.
Related
information
Input (Voltage) from work equipment pump oil pressure sensor can be checked in monitoring mode.
(Code 70701: Voltage of work equipment pump oil sensor)
Method of reproducing error code: Turn starting switch ON.
Possible causes
and standard
value in normal
state
Cause Standard value in normal state/Remarks on troubleshooting
1Defective 24V power source
system
See if error code [DAQ6KK] is displayed. If it is displayed, carry out
troubleshooting for it first.
2
Defective work equipment
pump oil pressure sensor
(Internal trouble)
aPrepare with starting switch OFF, turn starting switch ON and carry
out troubleshooting.
HHP Voltage
BetweenC A 0.5 6.0V
3
Disconnection in wiring har-
ness (Disconnection in wir-
ing or defective contact in
connector)
aPrepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between TMCN1 (female)F
HHP (female)BResistance Max. 1z
Wiring harness between TMCN1 (female)9
HHP (female)CResistance Max. 1z
4
Short circuit with chassis
ground in wiring harness
(Contact with ground circuit)
aPrepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Short circuit of wiring harness between
TMCN1 (female)9 HHP (female)C with
chassis ground
Resistance Min. 1Mz
5Defective transmission con-
troller
aPrepare with starting switch OFF, turn starting switch ON and carry
out troubleshooting.
TMCN1 (female) Voltage
Between9 K 0.5 6.0V