development of room temperature and superconducting ch … · 2007. 5. 21. · institut für...
TRANSCRIPT
![Page 1: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/1.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 1 HPPA 2007
HPPA 2007
Mol, Belgium, May 6.-9. 2007
Holger J. Podlech
Institut für Angewandte Physik (IAP)
J.W.-Goethe-Universität, Frankfurt am Main, Germany
Development of Room Temperature and SuperconductingCH-Structures for High Power Applications
![Page 2: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/2.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 2 HPPA 2007
• H-mode cavities – CH-structure
• room temperature (rt) CH-structure (FAIR p-linac)
• superconducting (sc) CH-structure
• Projects (EUROTRANS, IFMIF)
Overview
![Page 3: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/3.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 3 HPPA 2007
IH-Structure
4-Vane RFQIH-RFQ
CH-Structure
Interdigital H-Mode (IH)B E
++
-- Interdigital H-Mode (IH)BBB E
++
-- B E
++
++
--
--
Crossbar H-Mode (CH)BBB E
++
++
--
--
Crossbar H-Mode (CH)
The Family of H-mode cavities (H11, H21)
![Page 4: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/4.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 4 HPPA 2007
High efficiency (Z) for low and medium energies (3-100 AMeV)
• Homogeneous distribution of lossesGood cooling possibilities
• Possible cw operation
• Use of KONUS Less rf defocusinglong lensfree sections
• High real estate gradients
• High mechanical stability
• Room temperature- and superconducting operation
H - CavityH - Mode211
RF Frequency 432 MHz
The CH-StructureCross-Bar H-Mode-Structure
![Page 5: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/5.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 5 HPPA 2007
rt IHE< 30 AMeV
30<f<250 MHz
rt CH E< 100 AMeV
150<f<700 MHz
sc CH E< 100 AMeV
150<f<700 MHz
H-mode DTL- cavities
![Page 6: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/6.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 6 HPPA 2007
p-bar target
p-linac
Super- FRS
SIS100SIS300
HESR
CRRESR
Unilac
The FAIR Accelerator ComplexSIS 100
NESR
HESR Antiproton Prod. Target
SIS18
CR
GSI Today
RESR
p-linac SIS 300
UNILAC
FAIR 100 m
FAIR: Facility for Antiproton and Ion Research
7⋅1010 cooled / hour
⇔
2⋅1016 p / hour
Requirement: 7*1012 p/pulseUNILAC: Factor 500 too low
New dedicated p-injector
p
![Page 7: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/7.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 7 HPPA 2007
95 keV 3 MeV 70 MeV
Source LEBT RFQ CH-DTLRe-Buncher
to Dump
to SIS18
Particles Protons RF drivers (6x) 2.5 MW KlystronsCurrent (mA) 70 Pulse power (MW) 4.9Energy (MeV) 70 Beam pulse length (μs) 36Frequency (MHz) 325.224 Repetition rate (Hz) 4RF structures (6x) r.t. CCH Linac length (m) 25
FAIR proton-linac
High gradients (3-7 MV/m), low duty cycle r.t. CH-structures
![Page 8: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/8.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 8 HPPA 2007
The Coupled CH (CCH)
Coupling Cavity (E010)
Coupling of two CH-sections (H21-mode) via a resonant oscillating coupling cell (E010-mode)
![Page 9: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/9.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 9 HPPA 2007
The 2 kW level (4kW/m, ~ 310 kV) has been reached within 20 minutes
Measured Q0: 13000 (95 % Ideal MWS Value)
r.t. CH-prototype Test Setup
![Page 10: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/10.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 10 HPPA 2007
Motivation for the Development of the Superconducting CH-Structure
Several fixed velocity accelerators with cw operation areunder discussion
(i.e. Spallation neutron sources, IFMIF, Transmuter, isotope production...)
Superconducting operation
lack of efficient superconducting low β cavities,whereas efficient means large energy gain per cavity
![Page 11: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/11.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 11 HPPA 2007
SuperconductingCH-Prototype
The first low energy s.c.multi cell cavity
140 mm
Gap number 19
Length (mm) 1048
Frequency (MHz) 350
(Ra/Q)G (Ω2) 178000
W (mJ/(MV/m)2) 155
β 0.1
Ep/Ea (βλ-definition) 5.2
G=RsQ0 (Ω) 56
Ra/Q (Ω) (T incl.) 3180
Bp/Ea (mT/(MV/m)) 5.7
Q0 (BCS, 4.4K, 352 MHz) 1.5x109
![Page 12: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/12.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 12 HPPA 2007
Cryogenic Test of the sc CH-cavity
tP
rP
fP
fon PP =rP
eoff PP =
![Page 13: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/13.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 13 HPPA 2007
Q0 versus Gradient and Voltage
L=n/2βλ=9.5βλGradient Voltage
![Page 14: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/14.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 14 HPPA 2007
Projects and possible applications (sc CH)
EUROTRANS (Nuclear waste transmutation)
IFMIF (Fusion material research)
![Page 15: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/15.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 15 HPPA 2007
A CH-Injector for XADS/EUROTRANS
![Page 16: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/16.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 16 HPPA 2007
• High flux source of fast neutrons
• Development of new material for fusion reactors
• Up to 100 dpa/fpy
• Liquid Li target
• Beam: 40 MeV Deuterons
• Beam current 2x125 mA
• Beam power: 10 MW
• Duty cycle 100%
• RFQ/CH combination with 175 MHz
IFMIF
International Fusion Material Irradiation Facility
Reference design: Alvarez!
![Page 17: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/17.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 17 HPPA 2007
r.t./s.c. CH-linac for IFMIF
s.c. cavity doublet with tuner
• One room temperature H-mode cavity (2.5-4.5 AMeV)• 8 superconducting CH-cavities (per linac)• Sc cavity RF power: 30 W• Static losses: 20 W per cavity
800 W@4K • 3 Cryo plants (500 W each) for IFMIF, 2 in operation ,1 stand by• Beam loading per cavity 400-500 kW• Power couplers: 2 coaxial-couplers per cavity with 250 kW
Main advantages
Stable cw operation without thermal problems
Significant operational cost savings: 5 MW 45 Mio kWh/a
![Page 18: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/18.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 18 HPPA 2007
IFMIF IAP Proposal: sc CH-Linac
![Page 19: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/19.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 19 HPPA 2007
People
U. RatzingerH. KleinH. PodlechH. LiebermannC. ZhangA. Bechtold
C. ClementeR. TiedeM. BuschF. DziubaD. BänschI. Müller
![Page 20: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/20.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 20 HPPA 2007
Conclusion
• The CH-structure is a very efficient DTL-Structure
larger real estate gradient, smaller number of sub-systems
reliability, cost reduction
• Suitable for room temperature and superconducting operation
• Prototypes have been developed and tested successfully
• Projects: FAIR p-linac, EUROTRANS, IFMIF
![Page 21: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/21.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 21 HPPA 2007
Thank you for your attention
![Page 22: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/22.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 22 HPPA 2007
Effective Shunt Impedance of DTL-Cavities
![Page 23: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/23.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 23 HPPA 2007
r.t. CH-cavity and MEBT for EUROTRANS
Steerer diagnostic
~ 215 cm
~ 175 cm
![Page 24: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/24.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 24 HPPA 2007
QuadsTubes
Envelopes r.t. CH-cavity
![Page 25: Development of Room Temperature and Superconducting CH … · 2007. 5. 21. · Institut für Angewandte Physik LINAC AG H. Podlech, IAP 4 HPPA 2007 High efficiency (Z) for low and](https://reader034.vdocuments.us/reader034/viewer/2022052011/6026a5477c3af278010c437d/html5/thumbnails/25.jpg)
Institut für Angewandte PhysikLINAC AG
H. Podlech, IAP 25 HPPA 2007
Beam Dynamics (KONUS)Code: LORASR
KONUS (Combined Zero Degree Structure)
0-degree-sections reduce rf defocusingLess focusing elements requiredlong lens free sectionsslim drift tubeshigh shunt impedance
Strong triplet-channel