Preprint typeset in JINST style - HYPER VERSION Development of a GEM based detector for the CBM Muon Chamber (MUCH) S. Biswas a,b* , D. J. Schmidt a , A. Abuhoza a , U. Frankenfeld a , C. Garabatos a , J. Hehner a , V. Kleipa a , T. Morhardt a , C.J. Schmidt a , H.R. Schmidt c and J. Wiechula c a GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstrasse 1, D-64291 Darmstadt, Germany b National Institute of Science Education and Research, Sachivalaya Marg, PO: Sainik School, Bhubaneswar - 751 005, Odisha, India c Eberhard-Karls-Universität, Tübingen, Germany E-mail: [email protected] ABSTRACT: The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been measured for cosmic ray. At high rate operation of GEMs the value of the protection resistor influences the gain and the stability. This feature has been investigated varying both the rate and the value of the protection resistor. This measurement has been performed using both X-ray generator and Fe 55 source. The ageing and long-term stability of GEM based detectors has been studied employing both X-ray generator and Fe 55 source. The ageing study of one GEM module is performed by using a 8 keV Cu X-ray generator to verify the stability and integrity of the GEM detectors over a longer period of time. The accumulated charge on the detector is calculated from the rate of the X-ray and the average gain of the detector. The details of the measurement and results has been described in this article. KEYWORDS: FAIR; CBM; Gas Electron Multiplier; Cosmic Ray; Long-term test; Ageing. * Corresponding author. arXiv:1310.0642v2 [physics.ins-det] 3 Oct 2013

Upload: others

Post on 19-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

Preprint typeset in JINST style - HYPER VERSION

Development of a GEM based detector for the CBMMuon Chamber (MUCH)

S. Biswasa,b∗, D. J. Schmidta, A. Abuhozaa, U. Frankenfelda, C. Garabatosa,J. Hehnera, V. Kleipaa, T. Morhardta, C.J. Schmidta, H.R. Schmidtc and J. Wiechulac

aGSI Helmholtzzentrum für Schwerionenforschung GmbH,Planckstrasse 1, D-64291 Darmstadt, Germany

bNational Institute of Science Education and Research,Sachivalaya Marg, PO: Sainik School, Bhubaneswar - 751 005, Odisha, India

cEberhard-Karls-Universität,Tübingen, GermanyE-mail: [email protected]

ABSTRACT: The characteristics of triple GEM detectors have been studied systematically by usingcosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEMvoltage setting. Efficiency of GEM detector has been measured for cosmic ray.At high rate operation of GEMs the value of the protection resistor influences the gain and thestability. This feature has been investigated varying both the rate and the value of the protectionresistor. This measurement has been performed using both X-ray generator and Fe55 source.The ageing and long-term stability of GEM based detectors has been studied employing both X-raygenerator and Fe55 source. The ageing study of one GEM module is performed by using a 8 keVCu X-ray generator to verify the stability and integrity of the GEM detectors over a longer periodof time. The accumulated charge on the detector is calculated from the rate of the X-ray and theaverage gain of the detector. The details of the measurement and results has been described in thisarticle.

KEYWORDS: FAIR; CBM; Gas Electron Multiplier; Cosmic Ray; Long-term test; Ageing.

∗Corresponding author.

arX

iv:1

310.

0642

v2 [

phys

ics.

ins-

det]

3 O

ct 2

013

Page 2: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

Contents

1. Introduction 11.1 CBM muon chamber detector concept 2

2. Cosmic ray test set-up 32.1 Results of cosmic ray test 4

3. Effect of protection resistor 5

4. Long-term study of GEM 8

5. Preliminary ageing study of GEM 10

6. Summary and Conclusion 14

1. Introduction

Gas Electron multipliers (GEM) will be used in the Muon Chamber (MUCH) located downstreamof the Silicon Tracking System (STS) of the Compressed Baryonic Matter (CBM) experimentalong with other sophisticated detectors at the future Facility for Antiproton and Ion Research(FAIR) in Darmstadt, Germany [1, 2, 3]. The CBM experiment at FAIR will use proton and heavyion beams to study matter at extreme conditions and to explore the QCD phase diagram in theregion of high baryon densities [4]. With CBM we will enter a new era of nuclear matter researchby measuring rare diagnostic probes never observed before at FAIR energies, and thus CBM hasa unique discovery potential. The focus of the CBM experiment is to detect the rarest probeslike Charmonia as a testimony of the early fireball, along with the conventional probes by varyingexperimental parameters e.g. beam energy or the centrality of the collisions. A very high beamintensity will enable to detect the rare probes which was not possible earlier at similar energies forstatistical reasons. In the CBM experiment, particle multiplicities and phase-space distributions, thecollision centrality and the reaction plane will be determined. For example, the study of collectiveflow of charmonium and multi-strange hyperons will shed light on the production and propagationof these rare probes in dense baryonic matter. This will only be possible with the application ofadvanced instrumentation, including highly segmented and fast gaseous detectors.

In this paper, we would like to present the results of characterization of triple GEM detectorsby cosmic ray, long-term test and ageing studies of GEM for CBM.

– 1 –

Page 3: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

Figure 1. Schematic view of the CBM experiment: Muon set up (left). Implementation of the muondetection system in GEANT (right).

1.1 CBM muon chamber detector concept

The measurements of J/ψ→ µ+µ− and low mass vector meson decay ρ0→ µ+µ−, ω0→ µ+µ−

and φ 0 → µ+µ− in Au + Au collisions at 25 AGeV have been proposed as a key probe to theindication of in-medium modification of hadrons, chiral symmetry restoration and deconfinementat high baryon density ρb.

This measurement would require a sophisticated muon detector (MUCH) located downstreamof the Silicon Tracking System (STS) of the CBM experiment. The current design of the muonsystem consists of 6 iron absorber layers of thickness 20, 20, 20, 30, 35, 100 cm respectivelyand 18 detector layers with ∼ 100 µm position resolution divided into 6 stations. The muondetector in the CBM experiment will be constructed in such a way that there will be micro-patterngaseous detectors with high rate capability at least in the first 4 stations and other detectors likepad chambers, thick GEM or straw tubes in the later stations [5]. A schematical view of the CBMdetector with its MUCH detection system is shown in Figure 1.

Simulation studies of the CBM detector system yield that in the first GEM layer of the muonchambers hit densities (H) of 0.5 hits/cm2/event at an event rate (R) of 107 Hz will occur. Thedetectors will have to withstand a large accumulated charge. If the gas gain (G) of the detector is 103

and the number of primary electrons/track (P) is 30 (for Argon and CO2) then after amplificationthe total number of electrons (Ne) is 1.5× 1011 /cm2/s [Ne=H×R×P×G]. The accumulated chargeper year (Qy) computes to around 0.75 C/cm2. In the 10 years period of the CBM experiment thetotal accumulated charge will thus be 7.5 C/cm2. Ageing studies are therefore crucial for extendedefficient detector operation.

– 2 –

Page 4: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

Figure 2. Cosmic ray test set-up.

2. Cosmic ray test set-up

Characteristics of GEM detectors have been studied systematically by using cosmic ray muons.The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting.The drift, transfer and induction gaps of the detector are 2 mm, 2 mm and 2 mm respectively. Thevoltage to the drift plane and individual GEM plates has been applied by 7 channel power supply(HVG210). Although there is a segmented readout pad (256 pads of 6×6 mm2 area) the signalin this study was obtained from two add up boards (named as S0 and S1 and each board summed128 pads) and a single input from each board is fed to a charge sensitive preamplifier. After that aPXI LabVIEW based data acquisition system is used. The drift field, induction field and the two-transfer fields were kept constant at 2.5 kV/cm, 2 kV/cm and 3 kV/cm respectively. The detectorhas been operated with argon and CO2 in 70/30 mixing ratio. The pulse height distribution forthe GEM has been studied by a NI PXI-5105 sampling ADC. In the cosmic ray measurement thetrigger of the sampling ADC has been taken by the coincidence signal of three plastic scintillators.The cosmic ray test set-up along with the GEM detector is shown in Figure 2.

– 3 –

Page 5: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

/ ndf 2χ 156.8 / 79

Constant 17.6± 694.7 MPV 2.4± 123.9 Sigma 1.97± 65.85

ADC channel

0 100 200 300 400 500 600 700 800

co

un

t

0

100

200

300

400

500

600

700

800 / ndf 2χ 156.8 / 79

Constant 17.6± 694.7 MPV 2.4± 123.9 Sigma 1.97± 65.85

Figure 3. A typical MIP spectrum at GEM voltage 400-395-390 V.

2.1 Results of cosmic ray test

Pulse height distribution is studied and the efficiency and crosstalk is measured by using cosmic ray.A typical minimum ionizing particle (MIP) spectrum at GEM voltage 400-395-300 V is shown inFigure 3. In this spectrum the signal and noise peak are well separated. The spectrum is fitted witha Landau distribution. The overflow at ADC channel 700 is due to saturation of the pre-amplifier.

The MPV of the Landau fitting for minimum ionizing particles are measured at different GEMvoltage settings. The MPV as a function of global GEM voltage is plotted in Figure 4.

The efficiency of the GEM detector is measured in the same cosmic ray test bench by varyingthe global GEM voltage. The efficiency as a function of the global GEM voltage is shown inFigure 5. A plateau at 95% has been achieved for cosmic ray.

The total number of read out pad for the GEM was 256 and of area 6×6 mm2 as mentionedin section 2. The readout pads are connected to two sum-up boards each with 128 pins. With thescintillator trigger both the signals have been read out. About 10% crosstalk in the pad plane hasbeen observed between the two segments of the GEM.

– 4 –

Page 6: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

(Volt)3

V∆+2

V∆+1

V∆

1140 1150 1160 1170 1180 1190 1200 1210

MP

V

20

40

60

80

100

120

Figure 4. MPV of Landau fitting as a function of global GEM voltage.

(Volt)3

V∆+2

V∆+1

V∆

1130 1140 1150 1160 1170 1180 1190 1200 1210 1220

eff

icie

nc

y

0.5

0.6

0.7

0.8

0.9

1

Figure 5. Efficiency as a function of the global GEM voltage.

3. Effect of protection resistor

At high rate operation of GEMs the value of the protection resistor influences the gain. This featurehas been investigated varying both the rate of X-ray and the value of the protection resistor. Thismeasurement has been performed using both Fe55 source and Cu X-ray generator.

In this whole set of measurements the GEM voltages i.e. ∆V1, ∆V2, ∆V3 have been kept

– 5 –

Page 7: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

rate (Hz)

1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000

mean

AD

C c

han

nel

340

360

380

400

420

440

460 protection resitanceΩ11 M

protection resitanceΩ1 M

protection resitance on topΩ11 M

Figure 6. Variation of the mean ADC channel (mean position of 5.9 keV peak of Fe55 X-ray spectrum withGaussian fitting) as a function of the rate varying the detector and source distance with collimator fixed withthe detector.

at 400 V, 395 V and 390 V and the drift, induction and two-transfer fields were kept constant at2.5 kV/cm, 2 kV/cm and 3 kV/cm respectively. The gain of the detector has been expressed byobtaining the mean position of 5.9 keV peak of Fe55 X-ray spectrum with Gaussian fitting [6, 7].Using Fe55 source the rate has been varied in two different ways. The collimator has been fixedwith the detector and the distance of the source from the detector is varied and the diameter ofthe collimator is varied keeping the source to detector distance constant. For these two sets ofmeasurements the variations of the mean ADC channel of 5.9 keV peak of Fe55 X-ray spectrum, asa function of the rate are shown in Figure 6 and Figure 7 respectively. For each set of measurementsthree sets of protection resistance value have been chosen. The sets are 11 MΩ protection resistanceto the drift plane and both the planes (top and bottom) of all three GEM foils, 1 MΩ protectionresistance to the drift plane and both the planes of all three GEM foils and 11 MΩ protectionresistance to the drift plane and on the top plane of all three GEM foils.

In both the set of measurements the mean ADC channel of 5.9 keV peak of Fe55 X-ray spec-trum decreases with the rate in all three sets of protection resistance value. The rate of decrease ofthe mean is maximum with 11 MΩ protection resistance to both the planes of all three GEM foils.

– 6 –

Page 8: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

rate (Hz)

0 10 20 30 40 50 60 70 80 90 100

310×

mean

AD

C c

han

nel

340

360

380

400

420

440

460 protection resitanceΩ11 M

protection resitanceΩ1 M

protection resitance on topΩ11 M

Figure 7. Variation of the mean ADC channel (mean position of 5.9 keV peak of Fe55 X-ray spectrum withGaussian fitting) as a function of the rate varying the diameter of the collimator.

Figure 8. Set-up with Cu X-ray generator.

Dependence of gain on protection resistance value is also measured using the Cu X-ray gen-erator. The upper part of the GEM is exposed to the X-ray from the generator and the Fe55 sourceis placed at the bottom part of the detector. The Fe55 spectrum is taken from the bottom part ofthe GEM at the same time when the upper part of the detector is exposed to the Cu X-ray from thegenerator. The Cu X-ray generator along with the GEM detector is shown in Figure 8. In this casethe rate of X-ray from the generator is changed by varying the bias voltage.

– 7 –

Page 9: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

X­ray rate (Hz)

0 50 100 150 200 250 300

310×

mean

AD

C c

han

nel

200

250

300

350

400

450 protection resitanceΩ11 M

protection resitanceΩ1 M

protection resitance on topΩ11 M

Figure 9. Variation of the mean ADC channel (mean position of 5.9 keV peak of Fe55 X-ray spectrum withGaussian fitting) as a function of the rate using Cu X-ray generator.

The variations of the mean ADC channel of 5.9 keV peak of Fe55 X-ray spectrum, as a functionof the Cu X-ray rate is shown in Figure 9 for all three sets of protection resistance combination i.e.11 MΩ to the drift plane and both the planes (top and bottom) of all three GEM foils, 1 MΩ to thedrift plane and both the planes of all three GEM foils and 11 MΩ to the drift plane and on the topplane of all three GEM foils. It is clear from the Figure 9 that in all three combination of protectionresistance value the mean decreases with the rate.

4. Long-term study of GEM

The long-term stability of the GEM has been studied using the same test setup. One GEM detectorhas been tested for about 14 days continuously. The voltages to the GEM 1, 2 and 3 were 400 V,395 V and 390 V whereas the drift, induction and the two-transfer fields were kept constant at2.5 kV/cm, 2 kV/cm and 3 kV/cm respectively. A collimated Fe55 source is placed in front of thedetector and the X-ray spectra have been taken for 10-minute interval. The mean position of 5.9keV Fe55 X-ray peak has been recorded with time. The variation of mean as a function of time isshown in Figure 10. The ambient temperature and pressure also recorded continuously and the T/pas a function of time is shown in Figure 11. A definite correlation between mean and T/p has beenobserved which is well known for any gas detector.

Therefore, a corrected and normalized gain g was computed from the effective gain G accord-ing to

– 8 –

Page 10: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

time (h)

0 50 100 150 200 250 300 350

me

an

(A

DC

ch

an

ne

l)

220

240

260

280

300

320

340

360

380

400

Figure 10. Mean (mean position of 5.9 keV peak of Fe55 X-ray spectrum with Gaussian fitting) as afunction of the period of operation.

time (h)

0 50 100 150 200 250 300 350

T/p

(K

/atm

)

290

291

292

293

294

295

296

297

298

299

300

Figure 11. T/p as a function of the period of operation.

g =G

AeBT/p (4.1)

The T/p is the ratio of temperature and pressure. A and B are fit parameters, determined byfitting the exponential function,

– 9 –

Page 11: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

T/p (K/atm)

290 291 292 293 294 295 296 297 298 299 300

me

an

(A

DC

ch

an

ne

l)

220

240

260

280

300

320

340

360

380

400

/ ndf 2χ 3.739e+05 / 2646

p0 6.398e­09± 5.384e­07

p1 4.015e­05± 0.06815

/ ndf 2χ 3.739e+05 / 2646

p0 6.398e­09± 5.384e­07

p1 4.015e­05± 0.06815

Figure 12. Correlation of detector gain and temperature & pressure: pulse height versus T/p and theexponential fits.

G(T/p) = AeBT/p (4.2)

to the correlation plot of Figure 12.

The exponential dependence in Eq. 4.2 is deduced by assuming inverse proportionality of theTownsend coefficient α to the mass density ρ; and thus α ∝ 1/ρ ∝ T/p [8].

The variation of the normalized gain as obtained by Eq. 4.1 is plotted in Figure 13. Still thereis about 10% variation of the gain from the average value with time. This variation might arisesfrom the variation of the O2 concentration in the gas as well as variation of the gas ratio due tochanges of the characteristics of the mass flow controller with temperature.

The variation of energy resolution with time for the detector is shown in Figure 14. The energyresolution varies between 17-20% in the whole period of operation.

5. Preliminary ageing study of GEM

An infrastructure has been set up at the GSI detector laboratory to study the ageing properties ofgas filled detectors such as multi wire proportional chambers (MWPC), gas electron multipliers(GEM) etc [9, 10]. An accuracy in the relative gain measurement below 1% has been achieved by

– 10 –

Page 12: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

time (h)

0 50 100 150 200 250 300 350

no

rma

lis

ed

ga

in

0

0.2

0.4

0.6

0.8

1

1.2

1.4

Figure 13. Normalized gain as a function of the period of operation.

time (h)

0 50 100 150 200 250 300 350

en

erg

y r

es

olu

tio

n (

%)

16

18

20

22

24

26

28

Figure 14. Energy resolution as a function of the period of operation.

monitoring environmental conditions and by systematic improvements of the measuring equipment[10]. The ageing study of one GEM module is performed in the same ageing measurement set-upby using a 8 keV Cu X-ray generator to verify the stability and integrity of the GEM detectorsover a period of time. The GEM has been operated at 395-390-385 V with drift, induction andtransfer field at 2.5 kV/cm, 2 kV/cm and 3 kV/cm respectively. The centre of the upper part of theGEM (region A) was exposed to high rate Cu X-rays for 10 minutes. Subsequently the Fe55 spectra

– 11 –

Page 13: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

Figure 15. Schematical view of the ageing measurement set-up.

have been observed for 1 minute each from upper and lower part (region B) of the GEM. The Fe55

source has been placed in such a way that the Fe55 X-rays direct toward the upper part of the GEMin the same spot, which was exposed by Cu X-ray. The ratio of the mean position of 5.9 keV Fe55

X-ray peak from upper side and lower side of GEM is the normalized gain and corrects the effectof pressure and temperature variations. The whole measurement is performed for about 70 hours.The schematical view of the ageing measurement setup is shown in Figure 15. The rate of the CuX-ray was about 240 kHz. The rate of X-ray on two sides of the detector as a function of time isshown in Figure 16.

The mean Fe55 peak positions obtained from the region A and B as a function of time is shownin Figure 17. The mean varies with time due to change of pressure and temperature. The gain fromthe two regions are slightly different due to the difference in the gain of the pre-amplifiers.

– 12 –

Page 14: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

time (h)

0 10 20 30 40 50 60 70

rate

(k

Hz)

0

50

100

150

200

250

A

B

Figure 16. Rate as a function of time.

time (h)

0 10 20 30 40 50 60 70

me

an

(A

DC

ch

an

ne

l)

460

480

500

520

540

560

580

B

A

Figure 17. Mean (mean position of 5.9 keV peak of Fe55 X-ray spectrum with Gaussian fitting) as afunction of time.

The accumulated charge on the detector is calculated from the rate of the X-ray and the averagegain of the detector. The normalized gain of the ageing part (A) to the gain of the reference part(B) along with the T/p as a function of accumulated charge per unit area is plotted in Figure 18. Nosign of ageing is observed after accumulation of more that 0.04 mC/mm2.

– 13 –

Page 15: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

)2dQ/dA (mC/mm

0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045

no

rma

lis

ed

ga

in

0.75

0.8

0.85

0.9

0.95

1

1.05

T/p

(K

/atm

)

295

296

297

298

299

300

301

302

)2dQ/dA (mC/mm

0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045

no

rma

lis

ed

ga

in

0.75

0.8

0.85

0.9

0.95

1

1.05

T/p

(K

/atm

)

295

296

297

298

299

300

)2dQ/dA (mC/mm

0 0.005 0.01 0.015 0.02 0.025 0.03 0.035 0.04 0.045

no

rma

lis

ed

ga

in

0.75

0.8

0.85

0.9

0.95

1

1.05

T/p

(K

/atm

)

295

296

297

298

299

300

normalised gain

T/p

Figure 18. The normalized gain and the T/p as a function of accumulated charge per unit area.

time (h)

0 10 20 30 40 50 60 70

en

erg

y r

es

olu

tio

n (

%)

14

15

16

17

18

19

20

A

B

Figure 19. Energy resolution as a function of time.

The energy resolution of the two parts as a function of time is shown in Figure 19. The energyresolution from both part varies between 16 to 19% in the period of operation.

6. Summary and Conclusion

In conclusion, systematic studies on the performances of the triple GEM detectors have been per-formed with a gas mixture of argon and CO2 in 70/30 mixing ratio. The minimum ionizing particle

– 14 –

Page 16: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

(MIP) spectra has been taken for different GEM voltage settings and the spectra has been fitted witha Landau distribution. An efficiency plateau at 95% has been achieved for cosmic ray. Crosstalk ofthe GEM signals are measured. About 10% crosstalk has been observed between the two segmentsof the GEM.

At high rate operation of GEMs the value of the protection resistor influences the gain and thestability. This feature has been investigated varying both the rate and the value of the protectionresistor, using both X-ray generator and Fe55 sources. In both the measurements it is clear that thegain is decreasing with the rate. The rate of decrease is maximum with the maximum value of theprotection resistor value.

The long-term stability and the ageing of triple GEM detectors has been studied employingboth X-ray and Fe55 sources. In the continuous operation of about 14 days the gain is measuredand normalized with the T/p value. The normalized gain fluctuates with time for about a 10% peakto peak value. This variation might comes from the variation of the O2 concentration in the gas aswell as variation of the gas ratio due to changes of the characteristics of the mass flow controllerwith temperature. Further investigation is necessary to correlate this variation with other ambientparameters. The energy resolution varies about 4% in this period of operation.

The ageing study of one GEM module is performed by using an 8 keV Cu X-ray generatorto verify the stability and integrity of the GEM detectors over a longer period of time. The ac-cumulated charge on the detector is calculated from the rate of the X-ray and the average gain ofthe detector. No sign of ageing is observed after accumulation of more that 0.04 mC/mm2. Com-pared to the total accumulated charge of 7.5 C/cm2 in the 10 years period of CBM experiment0.004 C/cm2 is just a first view into the ageing.

Acknowledgments

We are thankful to Dr. Ingo Fröhlich of University of Frankfurt, Prof. Dr. Peter Fischer of Institutfür Technische Informatik der Universität Heidelberg, Prof. Dr. Peter Senger, CBM Spokespersonand Dr. Subhasis Chattopadhyay, Deputy spokesperson, CBM for their support in course of thiswork. We are also grateful to Dr. Leszek Ropelewski and Dr. Serge Duarte Pinto of RD51 for theirvaluable suggestions.

References

[1] F. Sauli, GEM: A new concept for electron amplification in gas detectors, Nuclear Instruments andMethods in Physics Research Section A 386 (1997) 531.

[2] http://www.fair-center.eu/for-users/experiments/cbm.html

[3] http://www.fair-center.eu/

[4] CBM Progress report 2008.

[5] A. Prakash et al., Di-muon measurements in CBM experiment at FAIR, [nucl-ex/1102.0882].

[6] S. Biswas et al., Study of the characteristics of GEM for the FAIR experiment CBM, CBM Progressreport 2011.

– 15 –

Page 17: Development of a GEM based detector for the CBM Muon ... · 2.1 Results of cosmic ray test 4 3. Effect of protection resistor 5 4. Long-term study of GEM 8 5. Preliminary ageing study

[7] S. Biswas et al., Study of the characteristics of GEM detectors for the future FAIR experiment CBM,Nuclear Instruments and Methods in Physics Research Section A 718 (2013) 403.

[8] M.C. Altunbas et al., Aging measurements with the Gas Electron Multiplier (GEM), NuclearInstruments and Methods in Physics Research Section A 515 (2003) 249.

[9] A. Abuhoza, et al., Study of the influence of construction materials on the ageing properties of highrate gas detectors, Physics Procedia 37 (2012) 442.

[10] A. Abuhoza, et al., Setup optimization toward accurate ageing studies of gas filled detectors, NuclearInstruments and Methods in Physics Research Section A 718 (2013) 400.

– 16 –