YOUR REF: 109808-1 OUR REF: DA-2011-260
26 June 2012 Andergrove Lakes Pty Ltd c/- RPS Group (Mackay) Pty Ltd PO Box 1895 MACKAY QLD 4740 Dear Sir/Madam DEVELOPMENT APPLICATION Proposal: Material Change of Use - Multiple Dwelling Units (86) including
16 Dual Key Units (102 keys) & Commercial Premises (Catering Shop)
Application Number: DA-2011-260 Address: 70-90 Beaconsfield Road East, ANDERGROVE QLD 4740 Property Description: Part of Lot 1 on RP743633 Council acknowledges receipt of the revised plans of development for the above proposal received on 16 May 2012. The approved plans for job number 0910-1118 pages 102 and 103 (rev I), 112 and 301(rev B), are attached herein and satisfy condition 2 of the Decision Notice DA-2011-260. It is noted that some car parking matters in relation to condition 31-34 may be reviewed for compliance with Australian Standards at the time of Operational Works assessment. The acoustic treatments for Building Groups C and D as detailed in the approved assessment by NSA acoustics must be shown on the building plans lodged for the Building Works permit. Would you please update your records accordingly, if you require further information please contact the Julie Brook on 4961 9186. Yours faithfully Shane Kleve Principal Planner enc Approved Plans
This is a Mackay Regional Council digitally signed document.
This is a Mackay Regional Council digitally signed document.
This is a Mackay Regional Council digitally signed document.
This is a Mackay Regional Council digitally signed document.
This is a Mackay Regional Council digitally signed document.
30/03/2012 Project No. 313
NSA Acoustics ABN 66 037 556 829
PO Box 5163 Manly Qld 4179 PH (07) 3393 5667 FAX (07) 3393 4493 Email: [email protected]
30 March 2012 Contrast Constructions PO Box 2115 Windsor Qld 4030 Attention: Mr Philip Mason Dear Philip Re: Proposed Development- 70-90 Beaconsfield Road East, Andergrove
Buildings C & D - Road Traffic Noise Impacts Recommended Acoustic Treatments
This is in response to a request for NSA Acoustics to determine the acoustic ratings (Rw) for the construction components of the proposed Buildings C & D to be constructed at 70-90 Beaconsfield Road East, Andergrove in accordance with Mackay Regional Council’s Development Approval Ref No. DA-2011-260, Condition No. 39 ‘Acoustic Treatments’ as follows. ‘The developer shall design and construct the noise sensitive internal areas of the two buildings adjacent to Beaconsfield Road in accordance with AS 3671 to achieve the internal design level road traffic noise criteria set in Table 1 of the Acoustic report submitted and approved with the preliminary approval DA-2007-286. Demonstration of compliance with the acoustic report parameters shall be submitted to Council for separate approval.’’ The weighted sound reduction index, (Rw) for a particular building component (eg windows) is calculated by following the procedures set out in, Australian Standard AS3671 1989 ‘Road Traffic Noise Intrusion – Building Siting and Construction’ using the predicted road noise levels impacting onto most exposed facades of the proposed dwellings as presented in Table No. 1.
This is a Mackay Regional Council digitally signed document.
NSA Acoustics 2
30/03/2012 Project No. 313
Receptor Location Max LAeq,1hr(6am-10pm) Max LAeq,1hr(10pm-6am) Group C Gr Floor C1 60.6 52.5 Group C Level 1 C3 63.0 54.9 Group C Level 2 C6 64.0 55.9 Group C Level 3 C9 64.7 56.6 Group C Level 1 C2 68.1 60.0 Group C Level 2 C5 69.1 61.0 Group C Level 3 C8 69.7 61.6 Group C Level 1 C4 Sth 69.7 61.6 Group C Level 1 C4 Nth 54.4 46.3 Group C Level 2 C7 Sth 70.7 62.6 Group C Level 2 C7 Nth 54.4 46.3 Group C Level 3 C10 Sth 71.1 63.0 Group C Level 3 C10 Nth 54.4 46.3 Group D Level 1 D1/2, D5-7, D11/12 Sth 69.7 61.6 Group D Level 1 D1/2, D5&7, D11/12 Nth 54.4 46.3 Group D Level 2 D3/4, D8-10, D13/14 Sth 70.7 62.6 Group D Level 2 D3/4, D8&10, D13/14 Nth 54.4 46.3
Table 1: Predicted future road traffic noise impact levels. Acoustics calculations are based upon the drawings supplied by Idea Architecture Job No. 0910, 1118 Rev. B. Tables 2 to 5 present the recommended Rw ratings and typical construction to comply with the internal noise limits. For components with a Traffic Noise Reduction (TNR) less than or equal to 10, Construction Category 1 applies under AS3671 which requires ‘Standard construction; openings, including open windows and doors may compromise up to 10% of the exposed façade’, therefore mechanical ventilation is not required. For Construction Categories 2 to 4 doors and windows must be closed to achieve the required noise reduction which precludes the provision of natural ventilation. Therefore an air conditioning/mechanical ventilation system is to be installed in all internal noise sensitive areas in accordance with the Building Code of Australia guidelines. The typical glazing and building components recommended should only be used as a guide. Installers and suppliers of doors and window systems should provide certificates that the systems installed meet the recommended Rw ratings when tested under Australian Standard, AS1276-1999 ‘Acoustics – Rating of sound insulation in buildings and of building elements Part 1: Airborne sound insulation’.
This is a Mackay Regional Council digitally signed document.
NSA Acoustics 3
30/03/2012 Project No. 313
Unit Room Component Rw Typical Construction C1 Living/
Dining Kitchen/
Sliding Doors Windows Front Door External Walls
20 20 20 45
Standard glass standard frames Standard glass standard frames Solid Core Door Masonry
C1 Bedroom 1 Sliding Doors Windows External Walls
22 22 45
Standard glass in standard frames Standard glass in standard frames Masonry
C1 Bedroom 2 Windows External Walls
17 45
Standard glass in standard frames Masonry
C2 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
28 28 20 45
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Solid Core Door Masonry
C2 Bedroom 1 Sliding Doors Windows External Walls
30 30 45
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Masonry
C2 Bedroom 2 Windows External Walls
24 45
6mm plain glass with acoustic seals Masonry
C3 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
23 23 20 45
Standard glass standard frames Standard glass standard frames Solid Core Door Masonry
C3 Bedroom 1 Sliding Doors North West Window North East Window External Walls
25 25 20 45
6mm plain glass with acoustic seals 6mm plain glass with acoustic seals Standard glass in standard frames Masonry
C3 Bedroom 2 Windows External Walls
19 45
Standard glass in standard frames Masonry
C4 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
TNR ≤ 10 TNR ≤ 10 20 45
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry
C4 Bedroom 1 Sliding Doors Windows External Walls
31 31 45
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Masonry
C4 Bedroom 2 Sliding Door External Walls
30 45
6.38mm lam. glass with acoustic seals Masonry
C5 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
29 29 21 45
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Solid Core Door Masonry
C5 Bedroom 1 Sliding Doors Windows External Walls
31 31 45
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Masonry
C5 Bedroom 2 Windows External Walls
25 45
6mm plain glass with acoustic seals Masonry
Table 2: Recommended minimum Rw Ratings and acoustic treatments for noise sensitive internal areas of the proposed Building C.
This is a Mackay Regional Council digitally signed document.
NSA Acoustics 4
30/03/2012 Project No. 313
Unit Room Component Rw Typical Construction C6 Living/
Dining Kitchen/
Sliding Doors Windows Front Door External Walls
24 24 20 45
6mm plain glass with acoustic seals 6mm plain glass with acoustic seals Solid Core Door Masonry
C6 Bedroom 1 Sliding Doors North West Window North East Window External Walls
26 26 21 45
6mm plain glass with acoustic seals 6mm plain glass with acoustic seals Standard glass in standard frames Masonry
C6 Bedroom 2 Windows External Walls
20 45
Standard glass in standard frames Masonry
C7 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
TNR ≤ 10 TNR ≤ 10 21 45
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry
C7 Bedroom 1 Sliding Doors Windows External Walls
32 32 45
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Masonry
C7 Bedroom 2 Sliding Door External Walls
31 45
6.38mm lam. glass with acoustic seals Masonry
C8 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls Roof/ceiling
29 29 21 45 36
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm soundcheck with R2.0 Batts on top
C8 Bedroom 1 Sliding Doors Windows External Walls Roof/ceiling
31 31 45 33
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
C8 Bedroom 2 Windows External Walls Roof/ceiling
26 45 33
6mm plain glass with acoustic seals Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
C9 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
24 24 20 45
6mm plain glass with acoustic seals 6mm plain glass with acoustic seals Solid Core Door Masonry
C9 Bedroom 1 Sliding Doors North West Window North East Window External Walls Roof/ceiling
26 26 21 45 28
6mm plain glass with acoustic seals 6mm plain glass with acoustic seals Standard glass in standard frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard
C9 Bedroom 2 Windows External Walls Roof/ceiling
21 45 28
Standard glass in standard frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard
C10 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls Roof/ceiling
TNR ≤ 10 TNR ≤ 10 21 45 27
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm plasterboard
C10 Bedroom 1 Sliding Doors Windows External Walls Roof/ceiling
32 32 45 34
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
C10 Bedroom 2 Sliding Door External Walls Roof/ceiling
31 45 34
6.38mm lam. glass with acoustic seals Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
Table 3: Recommended minimum Rw Ratings and acoustic treatments for noise sensitive internal areas of the proposed Building C.
This is a Mackay Regional Council digitally signed document.
NSA Acoustics 5
30/03/2012 Project No. 313
Unit Room Component Rw Typical Construction D1/2 Living/
Dining Kitchen/
Sliding Doors Windows Front Door External Walls
TNR ≤ 10 TNR ≤ 10 22 45
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry
D1/2 Bedroom 1 Sliding Doors External Walls
31 45
6.38mm lam. glass with acoustic seals and frames Masonry
D1/2 Bedroom 1A Sliding Door External Walls
30 45
6.38mm lam. glass with acoustic seals Masonry
D3/4 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls Roof/ceiling
TNR ≤ 10 TNR ≤ 10 23 45 27
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm plasterboard
D3/4 Bedroom 1 Sliding Doors External Walls Roof/ceiling
32 45 34
6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D3/4 Bedroom 1A Sliding Door External Walls Roof/ceiling
31 45 34
6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D5/7 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
TNR ≤ 10 TNR ≤ 10 22 45
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry
D5/7 Bedroom 1 Sliding Doors External Walls
30 45
6.38mm lam. glass with acoustic seals Masonry
D6 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls
31 31 22 45
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Solid Core Door Masonry
D6 Bedroom 1 Sliding Doors External Walls
30 45
6.38mm lam. glass with acoustic seals Masonry
D8/10 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls Roof/ceiling
TNR ≤ 10 TNR ≤ 10 23 45 27
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm plasterboard
D8/10 Bedroom 1 Sliding Doors External Walls Roof/ceiling
31 45 34
6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D9 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls Roof/ceiling
31 31 23 45 37
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm soundcheck with R2.0 Batts on top
D9 Bedroom 1 Sliding Doors External Walls Roof/ceiling
31 45 34
6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
Table 4: Recommended minimum Rw Ratings and acoustic treatments for noise sensitive internal areas of the proposed Building D.
This is a Mackay Regional Council digitally signed document.
NSA Acoustics 6
30/03/2012 Project No. 313
Unit Room Component Rw Typical Construction D11 Living/
Dining Kitchen/
Sliding Doors Windows Front Door External Walls
TNR ≤ 10 TNR ≤ 10 21 45
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry
D11 Bedroom 1 Sliding Doors Windows External Walls
31 31 45
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Masonry
D11 Bedroom 2 Sliding Door External Walls
30 45
6.38mm lam. glass with acoustic seals Masonry
D12 Living/ Dining Kitchen/
Sliding Doors Nth Windows East Windows Front Door External Walls
TNR ≤ 10 TNR ≤ 10 28 21 45
Category 1: Standard construction, mechanical ventilation is not required. 6.38mm lam. glass with acoustic seals Solid Core Door Masonry
D12 Bedroom 1 Sliding Doors Windows External Walls
31 31 45
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Masonry
D12 Bedroom 2 Sliding Door East Window External Walls
30 27 45
6.38mm lam. glass with acoustic seals 6.38mm lam. glass with acoustic seals Masonry
D13 Living/ Dining Kitchen/
Sliding Doors Windows Front Door External Walls Roof/ceiling
TNR ≤ 10 TNR ≤ 10 22 45 27
Category 1: Standard construction, mechanical ventilation is not required. Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm plasterboard
D13 Bedroom 1 Sliding Doors Windows External Walls Roof/ceiling
32 32 45 34
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D13 Bedroom 2 Sliding Door External Walls Roof/ceiling
31 45 34
6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D14 Living/ Dining Kitchen/
Sliding Doors Nth Windows East Windows Front Door External Walls Roof/ceiling
TNR ≤ 10 TNR ≤ 10 30 23 45 27
Category 1: Standard construction, mechanical ventilation is not required. 6.38mm lam. glass with acoustic seals Solid Core Door Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D14 Bedroom 1 Sliding Doors Windows External Walls Roof/ceiling
32 32 45 34
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals and frames Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
D14 Bedroom 2 Sliding Door East Window External Walls Roof/ceiling
32 29 45 34
6.38mm lam. glass with acoustic seals and frames 6.38mm lam. glass with acoustic seals Masonry Sheet Metal roof with 1-layer 10mm plasterboard with R2.0 Batts on top
Table 5: Recommended minimum Rw Ratings and acoustic treatments for noise sensitive internal areas of the proposed Building D.
This is a Mackay Regional Council digitally signed document.
NSA Acoustics 7
30/03/2012 Project No. 313
If you have any queries do not hesitate to contact this office. Yours Faithfully
Martin Hodge Acoustical Consultant Attached: Rw Spreadsheet (2 Pages)
This is a Mackay Regional Council digitally signed document.
Rw RATINGS
Unit Room Component Impact Criteria TNR Component Floor Height RT60 C TNA RwdB(A) Area (m2) (m2) (m) (s)
C1 Liv/Kit Doors & Windows 60.6 45 15.6 7.62 36.78 2.40 0.70 2 14.20 20C1 Bedroom 1 Doors and Windows 52.5 40 12.5 7.94 12.00 2.40 0.70 2 16.15 22C1 Bedroom 2 Window 52.5 40 12.5 1.98 10.00 2.40 0.70 2 10.91 17
C2 Liv/Kit Doors & Windows 68.1 45 23.1 7.62 36.78 2.40 0.70 2 21.70 28C2 Bedroom 1 Doors and Windows 60.0 40 20.0 7.94 12.00 2.40 0.70 2 23.65 30C2 Bedroom 2 Window 60.0 40 20.0 1.98 10.00 2.40 0.70 2 18.41 24
C3 Liv/Kit Doors & Windows 63.0 45 18.0 7.62 36.78 2.40 0.70 2 16.60 23C3 Bedroom 1 Doors and Windows 54.9 40 14.9 7.94 12.00 2.40 0.70 2 18.55 25C3 Bedroom 2 Window 54.9 40 14.9 1.98 10.00 2.40 0.70 2 13.31 19
C4 Liv/Kit Sliding Doors 54.4 45 9.4 6.30 25.00 2.40 0.70 2 8.85 15C4 Bedroom 1 Doors and Windows 61.6 40 21.6 5.94 10.00 2.40 0.70 2 24.78 31C4 Bedroom 2 Sliding Door 61.6 40 21.6 5.04 10.00 2.40 0.70 2 24.06 30
C5 Liv/Kit Doors & Windows 69.1 45 24.1 7.62 36.78 2.40 0.70 2 22.70 29C5 Bedroom 1 Doors and Windows 61.0 40 21.0 7.94 12.00 2.40 0.70 2 24.65 31C5 Bedroom 2 Window 61.0 40 21.0 1.98 10.00 2.40 0.70 2 19.41 25
C6 Liv/Kit Doors & Windows 64.0 45 19.0 7.62 36.78 2.40 0.70 2 17.60 24C6 Bedroom 1 Doors and Windows 55.9 40 15.9 7.94 12.00 2.40 0.70 2 19.55 26C6 Bedroom 2 Window 55.9 40 15.9 1.98 10.00 2.40 0.70 2 14.31 20
C7 Liv/Kit Sliding Doors 54.4 45 9.4 6.30 25.00 2.40 0.70 2 8.85 15C7 Bedroom 1 Doors and Windows 62.6 40 22.6 5.94 10.00 2.40 0.70 2 25.78 32C7 Bedroom 2 Sliding Door 62.6 40 22.6 5.04 10.00 2.40 0.70 2 25.06 31
C8 Liv/Kit Doors & Windows 69.7 45 24.7 7.62 36.78 2.40 0.70 2 23.30 29C8 Liv/Kit Roof/ceiling 69.7 45 24.7 36.78 36.78 2.40 0.70 2 30.14 36C8 Bedroom 1 Doors and Windows 61.6 40 21.6 7.94 12.00 2.40 0.70 2 25.25 31C8 Bedroom 1 Roof/ceiling 61.6 40 21.6 12.00 12.00 2.40 0.70 2 27.04 33C8 Bedroom 2 Window 61.6 40 21.6 1.98 10.00 2.40 0.70 2 20.01 26C8 Bedroom 2 Roof/ceiling 61.6 40 21.6 10.00 10.00 2.40 0.70 2 27.04 33
C9 Liv/Kit Doors & Windows 64.7 45 19.7 7.62 36.78 2.40 0.70 2 18.30 24C9 Liv/Kit Roof/ceiling 64.7 45 19.7 36.78 36.78 2.40 0.70 2 25.14 31C9 Bedroom 1 Doors and Windows 56.6 40 16.6 7.94 12.00 2.40 0.70 2 20.25 26C9 Bedroom 1 Roof/ceiling 56.6 40 16.6 12.00 12.00 2.40 0.70 2 22.04 28C9 Bedroom 2 Window 56.6 40 16.6 1.98 10.00 2.40 0.70 2 15.01 21C9 Bedroom 2 Roof/ceiling 56.6 40 16.6 10.00 10.00 2.40 0.70 2 22.04 28
C10 Liv/Kit Sliding Doors 54.4 45 9.4 6.30 25.00 2.40 0.70 2 8.85 15C10 Liv/Kit Roof/ceiling 60.7 45 15.7 25.00 25.00 2.40 0.70 2 21.14 27C10 Bedroom 1 Doors and Windows 62.6 40 22.6 5.94 10.00 2.40 0.70 2 25.78 32C10 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34C10 Bedroom 2 Sliding Door 62.6 40 22.6 5.04 10.00 2.40 0.70 2 25.06 31C10 Bedroom 2 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34
This is a Mackay Regional Council digitally signed document.
Rw RATINGS
Unit Room Component Impact Criteria TNR Component Floor Height RT60 C TNA RwdB(A) Area (m2) (m2) (m) (s)
D1 Liv/Kit Sliding Doors 54.4 45 9.4 7.62 20.00 2.40 0.70 2 10.65 17D1 Bedroom 1 Sliding Doors 61.6 40 21.6 5.88 10.00 2.40 0.70 2 24.73 31D1 Bedroom 1A Sliding Doors 61.6 40 21.6 5.67 12.00 2.40 0.70 2 23.78 30
D2 Liv/Kit Sliding Doors 54.4 45 9.4 7.62 20.00 2.40 0.70 2 10.65 17D2 Bedroom 1 Sliding Doors 61.6 40 21.6 6.09 10.00 2.40 0.70 2 24.89 31D2 Bedroom 1A Sliding Doors 61.6 40 21.6 5.67 12.00 2.40 0.70 2 23.78 30
D3 Liv/Kit Sliding Doors 54.4 45 9.4 7.62 20.00 2.40 0.70 2 10.65 17D3 Liv/Kit Roof/ceiling 54.4 45 9.4 20.00 20.00 2.40 0.70 2 14.84 21D3 Bedroom 1 Sliding Doors 62.6 40 22.6 5.88 10.00 2.40 0.70 2 25.73 32D3 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34D3 Bedroom 1A Sliding Doors 62.6 40 22.6 5.67 12.00 2.40 0.70 2 24.78 31D3 Bedroom 1A Roof/ceiling 62.6 40 22.6 12.00 12.00 2.40 0.70 2 28.04 34
D4 Liv/Kit Sliding Doors 60.7 45 15.7 7.62 20.00 2.40 0.70 2 16.95 23D4 Liv/Kit Roof/ceiling 60.7 45 15.7 20.00 20.00 2.40 0.70 2 21.14 27D4 Bedroom 1 Sliding Doors 62.6 40 22.6 6.09 10.00 2.40 0.70 2 25.89 32D4 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34D4 Bedroom 1A Sliding Doors 62.6 40 22.6 5.67 12.00 2.40 0.70 2 24.78 31D4 Bedroom 1A Roof/ceiling 62.6 40 22.6 12.00 12.00 2.40 0.70 2 28.04 34
D5/7 Liv/Kit Sliding Doors 59.7 45 14.7 9.45 23.00 2.40 0.70 2 16.28 22D5/7 Bedroom 1 Sliding Doors 61.6 40 21.6 5.04 10.00 2.40 0.70 2 24.06 30
D6 Liv/Kit Doors and Windows 69.7 45 24.7 6.75 23.00 2.40 0.70 2 24.82 31D6 Bedroom 1 Sliding Doors 61.6 40 21.6 5.04 10.00 2.40 0.70 2 24.06 30
D8/10 Liv/Kit Sliding Doors 60.7 45 15.7 9.45 23.00 2.40 0.70 2 17.28 23D8/10 Liv/Kit Roof/ceiling 60.7 45 15.7 23.00 23.00 2.40 0.70 2 21.14 27D8/10 Bedroom 1 Sliding Doors 62.6 40 22.6 5.04 10.00 2.40 0.70 2 25.06 31D8/10 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34
D9 Liv/Kit Doors and Windows 70.7 45 25.7 6.75 25.00 2.40 0.70 2 25.45 31D9 Liv/Kit Roof/ceiling 70.7 45 25.7 23.00 25.00 2.40 0.70 2 30.78 37D9 Bedroom 1 Sliding Doors 62.6 40 22.6 5.04 10.00 2.40 0.70 2 25.06 31D9 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34
D11 Liv/Kit Sliding Doors 59.7 45 14.7 9.87 30.00 2.40 0.70 2 15.31 21D11 Bedroom 1 Doors and Windows 61.6 40 21.6 6.75 10.00 2.40 0.70 2 25.33 31D11 Bedroom 2 Sliding Doors 61.6 40 21.6 5.04 10.00 2.40 0.70 2 24.06 30
D12 Liv/Kit Sliding Doors 59.7 45 14.7 9.87 30.00 2.40 0.70 2 15.31 21D12 Bedroom 1 Doors and Windows 61.6 40 21.6 6.75 10.00 2.40 0.70 2 25.33 31D12 Bedroom 2 Sliding Doors 61.6 40 21.6 5.04 10.00 2.40 0.70 2 24.06 30
D13 Liv/Kit Sliding Doors 60.7 45 15.7 9.87 30.00 2.40 0.70 2 16.31 22D13 Liv/Kit Roof/ceiling 60.7 45 15.7 30.00 30.00 2.40 0.70 2 21.14 27D13 Bedroom 1 Doors and Windows 62.6 40 22.6 6.75 10.00 2.40 0.70 2 26.33 32D13 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34D13 Bedroom 2 Sliding Doors 62.6 40 22.6 5.04 10.00 2.40 0.70 2 25.06 31D13 Bedroom 2 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34
D14 Liv/Kit Doors and Windows 60.7 45 15.7 11.50 30.00 2.40 0.70 2 16.98 23D14 Liv/Kit Roof/ceiling 60.7 45 15.7 30.00 30.00 2.40 0.70 2 21.14 27D14 Bedroom 1 Doors and Windows 62.6 40 22.6 6.75 10.00 2.40 0.70 2 26.33 32D14 Bedroom 1 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34D14 Bedroom 2 Doors and Windows 62.6 40 22.6 5.58 10.00 2.40 0.70 2 25.51 32D14 Bedroom 2 Roof/ceiling 62.6 40 22.6 10.00 10.00 2.40 0.70 2 28.04 34