developed pmsg & appropriate converter
TRANSCRIPT
Investigations on Permanent Magnet Synchronous Generator for Different Renewable Energy
ApplicationsSubhrakanti Nanda
(Prime Minister’s Research Fellow)
1
Deptt. of E.E.IIEST, ShibpurGE Motors Pvt. Ltd
Mr. Koushik Pyne(Director)Industry Mentor
Prof. Mainak SenguptaProf. Deptt. Of EEAcademic Guide
PRESENTATION OUTLINE
2
• PART-I (introduction)o Target Applicationo Specification, Main Dimension & Material Selection
• PART-II (PMSG)o Design, Analysis & Fabrication
Surface Mounted PMSG
• PART-III (Converters)o Design, Analysis & Fabrication
Back to Back PWM Converter Vienna Rectifier Cuk Converter
2
• PART-IVo Modeling & Closed-Loop Control
• PART-Vo Experimental Set-Up & Testing
• PART-VIo Conclusion and Future Work
TARGET APPLICATION OF PERMANENT MAGNET SYNCHRONOUS GENERATOR (PMSG): 2kVA-5kVA
3
• 2kVA Permanent Magnet Synchronous Generator (PMSG) –o To provide-
reliable electricity to target group in remote hilly areas with pico-hydel system
o Target Group- Residents of large plantations A group of small planters / agriculturists Populace living in hilly hamlets
o Benefits of target group- Availability of electricity @ 100 W per home (minimum)[2/3 CFL lamps + one television set+ charging of mobile phones] Access to electricity Easy access to information systems
3
SPECIFICATIONS, MAIN DIMENSIONS & MATERIALS
4
o Targeted Specification of 2kVA PMSG
o Main Dimensions of 2kVA PMSG
o Materials usedStator Lamination: M36 (ss)Rotor Lamination: M36 (ss)Copper Wire: first varnish-polyester imide, 2ndvarnish-Polyamide ImideMagnet: NdFeB (grade 38)Rotor Sleeve: PVC Tape (Kevlar Roving for future use)Slot insulation: Nomex paperSlot Wedge: Wooden materialBearing: 6205 and 6206 SKF bearingHousing: Cast IronShaft: EN24
Rated power 2kVARated speed 1000 R.P.MNumber of poles, P 6Terminal line voltage 245V Phase 3 (star)Efficiency 90%Rated line current 5A
o Cross Section View of 2kVA PMSG Stator ID: 95 mm Stator OD: 158 mm Slot No. : 36 Air Gap: 0.8 mm Magnet Thickness:
4mm(At 150C, Br = 1.09T & Hc = 833598.7AT/m)
5
• PART-II (PMSG)o Design, Analysis & Fabrication
Surface Mounted PMSG
5
ELECTRO-MAGNETIC CALCULATIONS
6
o Bav = 0.65Wb/m2o ac = 10000 ac/mo Stack Length = 104.6mmo Efficiency = 0.92o Power Factor = 0.92 (assumed at worst
case)o Magnet Thickness = 4mmo Pole Arc = 44.1 degreeo Turns/Coil = 18o Mechanical Slot Fill Factor = 57%o Winding = staro Phase Resistance = 1.5 ohmo Ld & Lq = 17mHo Weight = 15Kg (considering Al
housing)o Calculations are done as per standard methods– See References 6
ELECTRO-MAGNETIC CALCULATIONS
7
o Permeance Coefficient (PC) value depends on type of permanent magnet using for the designFor sintered magnets 2-5 For Ferrite magnets 7-15Select PC in such a way magnet should not be demagnetized under peak load operating condition with factor of safety.
7
FINITE ELEMENT ELECTRO-MAGNETIC ANALYSIS
8
o 2-D Flux Plot o 2-D Flux Density Plot @ Rated Load
o No-Load BEMF @ 1000 rpm o Torque Current Characteristics8
9
Total weight 31 kg. Shell weight 19kg. Core and Copper weight 12 kg. Electrical Power Density = 154W/Kg Overall Power Density = 64W/Kg Electrical Torque Density= 1.47 N-m/Kg Overall Torque Density= 0.613N-m/Kg
Performance Prediction
o Predicted Performance of Designed PMSG -- Maximum continuous power 1840W Efficiency at rated load & speed 89% Temperature rise 0.613 deg C/W Maximum winding temperature 155 deg C Load current 5.7A No load AC voltage 245V(l-l) Loaded AC voltage 238V(l-l)
Figure: Phasor Diagram
Figure: Power Vs. Efficiency9
10
RMS 82V, 50Hz
Fabrication
Figure:2kVA PMSG Rotor withStainless Steel material
Figure:2kVA PMSG Rotorwith Silicon Steel material
Figure:2kVA PMSG Stator with Silicon Steel material
Figure:2kVA PMSG Stator with Silicon Steel material
Figure: Assembled 2kVAPMSG
Figure: Line Voltage, 50 Hz
Figure: Assembled 2kVAPMSG
Figure: Phase Voltage, 40 Hz
RMS 196V, 40Hz
10
11
Fabrication
2kVA PM-Rotor damaged during load test
2kVA PM-Rotor during repair at work-shop
12
Comparison between 2KVA PMSG (in motor mode) Induction Motor (IM) and Synchronous Motor (SM)
items Designed PMSG(D=95mm & L=101.4mm)
Available induction machine
Designed SM(D=95mm & L= 128.5mm)
Electrical weight 12 kg 23 kg. 22 kgTotal weight 31kg 42 kg 40kgPower density 64 W/kg 47.6 W/kg 50W/kgTorque density 0.613N-m/kg 0.45 N-m/kg 0.475 N-m/kg
12
1313
• PART-III & IV (Converters)o Design, Analysis & Fabrication
Back to Back PWM Converter Vienna Rectifier Cuk Converter
o Modeling & Closed-Loop Control
CONVERTER SPECIFICATIONS
14
Representative Diagram of Grid Interactive/ Isolated 2kVA PMSG
Protection Scheme- Over Current: Protection by
true current sensing on Input / Output AC side.
Over Voltage: Protection by voltage sensing on Input / Output AC side as well as DC side.
Short Circuit: Protection by Vce de-saturation detection
Cooling System- Forced air cooling with Fan
Environment- Ambient Temperature: 0-45oC Humidity: 95% RH max. Non-
Condensing Protection- IP 41 Control Platform- ALTERA
Cyclone-II FPGA (Ver.3.0)
Converter Topology-Two no. of 2-level 3–phase Inverters connected with common DC Cap Bank and Pre-charge Section.Rated Input Voltage- 440V, +5% / -10%, 3-Phase, 50Hz.Rated Input / Output Current- 30ASwitching Frequency- 10kHz
Active Front End
15
Representative Diagram of Active Front End
IGBT- BSM75GB120DN2- 75A, 1200V (Infineon)Electro Lytic Capacitor- 4700μF/450V, 6 Nos. (Kendeil)Snubber Capacitor - 0.47uF, 1.5 kV (Advance Comp. & Instr.)Gate Driver (Concept)Voltage Sensor– LV 20-P (LEM) Current Sensor - LA 55-P (LEM) Heatsink - 30F126 (Bhoomi)Pre-Charge Resistor- 100Ω±5%/60W (Kiyosh)Bleeder Resistor- 47kΩ±3%/10W (Raatronics)
Developed Back-Back PWM Converter
16
Module Level Test- Back to Back PWM Converter
17
Fig.1: Output voltage and load current with resistive load of 15 ohms
Fig.2: Output voltage and load current with inductive load of 4mH
Fig.3: VC-E of one group of IGBTs on load side
Load Test Result- Input Voltage: 3-Ph, 415V,50 Hz Output Voltage: 430V (measured at no load
condition) Load Current: 25 A Ambient Temperature: 28.9oC Final Temperature: 52.3oC Test duration: 30 min.
DC Link Discharge Test-The DC link capacitor bank 4700μF/450 V with sharing resistor 47kΩ is charged to rated DC link voltage of 700 V without triggering IGBTs. The total time required for discharge is found to be 14 minutes approximately.
18
Three level three switch Vienna rectifier.
18
Vienna Rectifier
Circuit Operation Control Block Diagram
1919
Developed Vienna Rectifier
2020
Module Level Test- Vienna Rectifier with Hysteresis Controller
Hysteresis Reference Phase V & I without switching
Input Voltage & Current Unit Vectors from Encoder
Prototype Cuk Converter
Fabricated Cuk Converter in Laboratory
A Cuk Converter in Continuous Conduction Mode
21
Close-Loop Control of Cuk Converter
Linear State Variable Feedback Control with Reference Tracking
• LSVF for Non-Minimum Phase System (Cuk Converter): Conventional Control Principles not applicable• A full state feedback regulator plus integral controller (to reduce steady state tracking error) is given by
u = -Kx + KI*e(t)• Which uses the matrix K to place the poles of the system at desired locations.
22
Real Time Simulation Results
23
Output Voltage (Vo) and Input Current (I1)
Voltage across C1 (Vc) and Output Current (I2)
23
Output Voltage (Vo) and Input Current (I1)
Voltage across C1 (Vc) and Output Current (I2)
Module Level Test- CuK Converter
24
2525
• PART-V o Experimental Set-Up & Testing
2626
Prototype PMSG & Converters
PMSG set-up: 2kVA , 1000 rpm PMSG coupled with 3.5kW, 220 V DC motor load
PMSG, Converter & Load
Parameter Estimated value Experimental value
Ra(ohm)/phase 1.6 1.82Ld(mH) 17 18.86Lq(mH) 17 18.86Ke (VL-L(rms) /1000rpm) 245 247
PMSG
LOAD
CONVERTER
27
2kVA PMSG Full Load Test Result (Gen. alone)
Sl. No.
V(L-L)(V)
I (L) (A)
Speed (rpm)
Generated power(W)
I/P shaft power(W)
% Load Generator eff (%)
1 236 1.3 1008 540.4 659 33 82
2 232 2 1001 803.6 924 40 87
3 230.5 4.2 1001 1676.7 1895 84 88.5
4 226 5.5 1005 2153 2360 104 90
27
28
Test Results & WaveformsSpeed (rpm) No-load Line
Voltage (Vrms)1000 247.5900 223.4800 198.5700 172.9600 147.5500 123400 99300 73200 49
Experimental BEMF (line) at Different SpeedExperimental BEMF (line) Vs. Speed
Experimental Waveform BEMF(ph) at 1000 rpm (gain:50)
bemf vs. speed
050
100150200250300
0 500 1000 1500rpm
Vrms bemf vs. speed
28Sim. &Exp. BEMF (line) Vs. Speed
29
Test Results & Waveforms
Unit Vectors Generated from Encoder Input Voltage & Current Waveformsof AFE
Output Voltage & Current Waveforms of Inverter (R Load)
Output Voltage & Current Waveforms of Inverter (R-L Load)29
30
Experimental Results withHysteresis Band based ControlSl. No.
Speed(rpm)
DC Link(V)
GeneratorCurrent(rpm)
Generated power(W)
DC link
current (A)
% Load
DC link power (W)
1 1000 419 1.4 540.4 1.1 27 460
2 1000 418 2 803.6 1.67 40 700
3 1000 418 4 1590 3.23 80 1350
4 1000 418 5.5 2100 4.6 105 1920
30
Test Results & Waveforms
Power Vs. Efficiency (Simulation) Power Vs. Efficiency (Test)
0102030405060708090100
0
500
1000
1500
2000
2500
0 200 400 600 800 1000 1200
Effice
ncy in
%
Powe
r (W)
rpm
outputpowerinput power
efficiency
3131
Simulation & Experimental WaveformsWith Hysteresis Band based Control
Dc Link Voltage (yellow)Generated Phase Voltage (magenta)Current drawn from the generator (sky blue) Scale- 1:140
Dc Link Voltage (green)Generated Phase Voltage-180Vpk (magenta)Current drawn from the generator-7.8Apk (yellow)
Corresponds to DC Link Voltage 418V and Generator is 100% Loaded with rated speed of 1000 rpm3232
33
• PART-VIo Conclusion & Future Work
33
Conclusions
Future Work
34
Fabrication & Testing of IPMSG Sensor-less closed-loop control of Vienna Rectifier Integration of the total system and testing
Fault Tolerant PMSG- insulation / vector control Simulation shows +/- 40% speed variation of the generator is able to
maintain 700V DC-Link Voltage It’s expected that the proposed scheme (with Cuk converter included)
can handle further speed variation while maintaining the same DC Link Voltage.
Conventional Synchronous Alternator is inferior in performance
Publications Nanda S, Ganguly D, Sengupta M, ‘Weight Optimised Design, Performance
Comparison and Finite Element Analysis of a Brushless DC Motor Using Two Different Materials’, Proc. of the 1st National Power Electronics Conference, NPEC-2005, Dec. 2005, IIT Kharagpur, INDIA.
Nanda S, Sengupta M and Sengupta A, ‘Modeling, Real-Time Simulation, Fabrication of and Experiments on a Boost-Buck (Cuk) Converter’, Proc. of the 6th National Power Electronics Conference, NPEC-2013, Dec. 2013, IIT Kanpur, INDIA.
Nanda S, Sengupta M and Sengupta A, ‘Modeling, Simulation, Fabrication, Experiments and Real-Time Linear State Variable Feedback Control of CukConverter using Pole Placement Technique’ Trans. of The Institution of Engineers (India): Series B , Volume 95, issue1, Jan-Mar 2014.
Nanda S, Sengupta M ‘Design, Analysis, Fabrication and Investigations of a Permanent Magnet Synchronous Generator for different renewable energy applications’, proc of PEDES - 2014. IEEE Conference, Dec. 2014, IIT Bombay, INDIA
Nanda S, Sengupta M, ‘Fabrication, Parameter Evaluation and Testing of a Permanent Magnet Synchronous Generator’ , Proc. of the 7th National Power Electronics Conference, NPEC-2015, Dec. 2015, IIT Bombay, INDIA.
35
References
36
[1] S.Paitandi And M.Sengupta, Design, analysis of a PMSM and its Comparative study With a Induction Machine of Same Nominal Rating, NPEC, December 2013, IIT Kanpur[2] D.O’Kelly And S.Simmons, Generalized Electrical Machine Theory, McGRAW HILL, 1968.[3] M. Sengupta, Construction, Analysis and Performance of Switched Reluctance and Brushless D.C Motors, M.E Thesis, IIT Kharagpur, December 1993.[4] R.Krishnan, Permanent Magnet Synchronous And Dc Motor Drives,Crc Press,2005[5] S.K. Nanda, 1kW, 48V, 2000rpm, 4pole BLDC Motor for Electric Vehicle Application, M.E. Thesis, Department of EE, BESU, Shibpur, 2006.[6] Nanda, S.; Sengupta, M. Design, fabrication and analytical investigations on a permanent magnet synchronous generator, Power Electronics, Drives and Energy Systems (PEDES), 2014 IEEE International Conference[7] www.ansys.com[8] en.wikipedia.org/wiki/Picohydro[9] D. Hanselman. Brushless permanent magnet motor design. US: The Writers Collective, 2 edition, 2003.
ACKNWOLEDGEMENTSo CII, DST for the Prime Minister’s Research Fellowship o M/s G E Motors Pvt. Ltdo Director IIEST, Shibpur, Prof. Ajoy K. Ray o My research guide – Prof. Mainak Senguptao Fund Support for POC -- funded by the Department of Electronics and Information Technology (DeitY), GOI under NaMPET – II Programo Advanced Power Electronics lab, Research Scholars and colleagues in the lab, particularly Mr. N. Datta, TAo Veeral Controls, Gandhinagar
37
38