determining proper burst size

Upload: mettlemaster

Post on 06-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/17/2019 Determining Proper Burst Size

    1/5

    Determining Proper urst Size for Traffic Policers

    This topic covers the following information:

    Policer Burst Size Limit Overview

    Effect of Burst-Size Limit

    Two Methods for Calculating Burst-Size Limit

    Comparison of the Two Methods

    Policer Burst Size Limit Overview

    A policer burst-size limit controls the number of bytes of traffic that can pass unrestricted through a

    policed interface when a burst of traffic pushes the average transmit or receive rate above the configured

    bandwidth limit. The actual number of bytes of bursty traffic allowed to pass through a policed interface

    can vary from zero to the configured burst-size limit, depending on the overall traffic load.

    By configuring a proper burst size, the effect of a lower shaped rate is alleviated. Use the burst-size-

    limit statement to configure the burst size.

    Note: If you set the burst-size limit too low, too many packets will be subjected to rate

    limiting. If you set the burst-size limit too high, too few packets will be rate-limited.

    Consider these two main factors when determining the burst size to use:

    The allowed duration of a blast of traffic on the line.

    The burst size is large enough to handle the maximum transmission unit (MTU) size of the packets.

    The following general guidelines apply to choosing a policer burst-size limit:

    A burst-size limit should not be set lower than 10 times the MTU of the traffic on the interface to be policed.

    The amount of time to allow a burst of traffic at the full line rate of a policed interface should not be lower than 5 ms.

    The minimum and maximum values you can specify for a policer burst-size limit depends on the policer type (two-

    color or three-color).

    Best Practice: The preferred method for choosing a burst-size limit is based on the

    line rate of the interface on which you apply the policer and the amount of time you

    want to allow a burst of traffic at the full line rate.

    Effect of Burst-Size Limit

    Bursty traffic requires a relatively large burst size so that extra tokens can be allocated into the token

    bucket for upcoming traffic to use.

    Bursty Traffic Policed Without a Burst-Size Limit

    Figure 1 shows an extreme case of bursty traffic where the opportunity to allocate tokens is missed, and

    the bandwidth goes unused because a large burst size is not configured.

    Figure 1: Bursty Traffic Without Configured Burst Size Excessive Unused Bandw idth)

    http://-/?-http://-/?-http://-/?-

  • 8/17/2019 Determining Proper Burst Size

    2/5

    Burst-Size Limit Configured to Match Bandwidth Limit and Flow Burstiness

    Figure 2 depicts how bandwidth usage changes when a large burst size is configured to handle burstytraffic. The large burst size minimizes the amount of unused bandwidth because tokens are being

    allocated in between the bursts of traffic that can be used during traffic peaks. The burst size determines

    the depth of the token bucket.

    Figure 2: Bursty Traffic with Configured Burst Size Less Unused Bandwidth)

    Burst-Size Limit That Depletes All Accumulated Tokens

    Configuring a large burst size for the unused tokens creates another issue. If the burst size is set to a very

    large value, the burst of traffic can be transmitted from the interface at line rate until all the accumulated

    tokens in the token bucket are used up. This means that configuring a large burst size can allow too many

    packets to avoid rate limiting, which can lead to a traffic rate that exceeds the bandwidth limit for an

    extended period of time.

    If the average rate is considered within 1 second, the rate is still below the configured bandwidth limit.

    However, the downstream device might not be able to handle bursty traffic, so some packets might be

    dropped.

    Two Methods for Calculating Burst-Size Limit

    For policers configured on MX Series, M120, and M320 routers, and EX Series switches, configurable burst-

    Next PagePrevious Page

    http://-/?-

  • 8/17/2019 Determining Proper Burst Size

    3/5

    size limit values range from 1 ms through 600 ms of traffic at the policer rate (the configured bandwidth

    limit).

    Because one burst size is not suitable for every traffic pattern, select the best burst size for an interface by

    performing experimental configurations. For your first test configuration, select the burst-size limit by

    using one of the calculation methods described in the next two sections.

    Calculation Based on Interface Bandwidth and Allowable Burst Time

    If the bandwidth of the policed interface is known, the preferred method for calculating the policer burst-

    size limit is based on the following values:

    bandwidth—Line rate of the policed interface (in bps units)

    burst-period—Allowable traffic-burst time (5 ms or longer)

    To calculate policer bandwidth in bytes:

    bandwidth X burst-period / 8

    Calculation Based on Interface Traffic MTU

    If the bandwidth of the policed interface is unknown, calculate the policer burst-size limit based on the

    following value:

    interface MTU—Maximum transmission unit (in bytes) for the policed interface.

    To calculate policer bandwidth in bytes:

    interface MTU Χ 10

    Comparison of the Two Methods

    Figure 3 illustrates the relationship between the policer rate (the configured bandwidth limit) and theeffective burst-size limit for the two methods of calculating the best policer burst-size limit. For the

    method based on interface bandwidth and allowable burst time, the correlation is labeled 5 ms. For the

    method based on MTU size, the correlation is labeled 10 MTU.

    Figure 3: Comparing Burst Size Calculation Methods

    For a policer burst-size limit calculated using the 5 ms method, the effective burst-size limit is

    proportional to the configured bandwidth limit. With a very low bandwidth limit, the effective burst-size

    limit might be so small that the policer rate-limits traffic more aggressively than desired. For example, a

    traffic “burst” consisting of two MTU-sized packets might be rate-limited. In this scenario, a policer burst-

    size limit calculated using the 10 MTU method appears to be a better choice.

    http://-/?-

  • 8/17/2019 Determining Proper Burst Size

    4/5

    10 x MTU Method for Selecting Initial Burst Size for Gigabit Ethernet with 100 Kbps

    Bandwidth

    The following sequence illustrates the use of the 10 x MTU method for selecting an initial burst size for

    test configurations for a Gigabit Ethernet interface configured with a 100 Kbps bandwidth limit:

    1. If you configure a 100 ms burst-size limit, the maximum amount of traffic allowed to pass through the

    interface unrestricted is 1250 bytes, calculated as follows:

      100,000 bps x 0.1 s

    100 Kbps x 100 ms = ————————————————————— = 1250 bytes

      8 bits per byte

     

    2. In theory, a 10 x MTU burst size would allow up to 15,000 bytes to pass unrestricted. However, the

    maximum configurable burst-size limit for MX Series, M120, and M320 routers is 600 ms of the

    bandwidth limit. If you configure the maximum burst-size limit of 600 ms of the bandwidth limit, the

    maximum amount of traffic allowed to pass through the interface unrestricted is 7500 bytes,

    calculated as follows:

      100,000 bps x 0.6 s

    100 Kbps x 600 ms = ————————————————————— = 7500 bytes

      8 bits per byte

     

    On a Gigabit Ethernet interface, a configured burst-size limit of 600 ms creates a burst duration of

    60 μs at Gigabit Ethernet line rate, calculated as follows:

      7500 bytes 60,000 bits

     ———————————— = ——————————————————— = 0.00006 s = 60 μs

      1 Gbps 1,000,000,000 bps

    3. If the downstream device is unable to handle the amount of bursty traffic allowed using the initial burst size

    configuration, reduce the burst-size limit until you achieve acceptable results.

    5 ms Method for Selecting Initial Burst Size for Gigabit Ethernet Interface with

    200 Mbps Bandwidth

    The following sequence illustrates the use of the 5 ms method for selecting an initial burst size for testconfigurations for a Gigabit Ethernet interface configured with a 200 Mbps bandwidth limit. This example

    calculation shows how a larger burst-size limit can affect the measured bandwidth rate.

    1. If you configure a 5 ms burst-size limit, the maximum amount of traffic allowed to pass through the

    interface unrestricted is 125,000 bytes (approximately 83 1500-byte packets), calculated as follows:

      200,000 bps x 0.005 s

    200 Mbps x 5 ms = ——————————————————————— = 125,000 bytes

      8 bits per byte

     

    On a Gigabit Ethernet interface, a configured burst-size limit of 5 ms creates a burst duration of 1 ms at

    Gigabit Ethernet line rate, calculated as follows:

  • 8/17/2019 Determining Proper Burst Size

    5/5

      125,000 bytes 1,000,000 bits

     ——————————————— = ——————————————————— = 0.001 s = 10 ms 1 Gbps 1,000,000,000 bps

     

    The average bandwidth rate in 1 second becomes 200 Mbps + 1 Mbps = 201 Mbps, which is a minimal

    increase over the configured bandwidth limit at 200 Mbps.

    2. If you configure a 600 ms burst-size limit, the maximum amount of traffic allowed to pass through theinterface unrestricted is 15 Mbytes (approximately 10,000 1500-byte packets), calculated as follows:

      200,000 bps x 0.6 s

    200 Mbps x 600 ms = ————————————————————— = 15,000,000 bytes

      8 bits per byte

     

    On a Gigabit Ethernet interface, a configured burst-size limit of 600 ms creates a burst duration of

    120 ms at Gigabit Ethernet line rate, calculated as follows:

      15,000 bytes 120,000 bits

     —————————————— = ——————————————————— = 0.012 s = 120 ms

      1 Gbps 1,000,000,000 bps

     

    The average bandwidth rate in 1 second becomes 200 Mbps + 120 Mbps = 320 Mbps, which is much

    higher than the configured bandwidth limit at 200 Mbps.

    200 Mbps Bandwidth Limit, 5 ms Burst Duration

    If a 200 Mbps bandwidth limit is configured with a 5 ms burst size, the calculation becomes200 Mbps x

    5 ms = 125 Kbytes, which is approximately 83 1500-byte packets. If the 200 Mbps bandwidth limit is

    configured on a Gigabit Ethernet interface, the burst duration is 125000 bytes / 1 Gbps = 1 ms at the

    Gigabit Ethernet line rate.

    200 Mbps Bandwidth Limit, 600 ms Burst Duration

    If a large burst size is configured at 600 ms with the bandwidth limit configured at 200 Mbps, the

    calculation becomes 200 Mbps x 600 ms = 15 Mbytes. This creates a burst duration of 120 ms at the

    Gigabit Ethernet line rate. The average bandwidth rate in 1 second becomes 200 Mbps + 15 Mbytes =

    320 Mbps, which is much higher than the configured bandwidth limit at 200 Mbps. This example shows

    that a larger burst size can affect the measured bandwidth rate.

    Related Documentation

    EX M MX T Series

    Policer Implementation Overview

    Understanding the Benefits of Policers and Token Bucket Algorithms

    Modified: 2014-10-22

    http://www.juniper.net/documentation/en_US/junos15.1/topics/concept/policer-mx-m120-m320-benefits-understanding.htmlhttp://www.juniper.net/documentation/en_US/junos15.1/topics/concept/policer-mx-m120-m320-implementation-overview.html