detector application gas mixtures for active target ... · daniel yates advisor: dr. rogachev....

19
Electrical properties of various gas mixtures for active target detector application Daniel Yates Advisor: Dr. Rogachev

Upload: others

Post on 03-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Electrical properties of various gas mixtures for active target

detector applicationDaniel Yates

Advisor: Dr. Rogachev

Page 2: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Texas Active Target (TexAT)● New active target detector under development by Rogachev

Group● Time projection chamber (TPC) setup● Gases will be used with TexAT

○ Target of beam○ Active medium for tracking

● Will be used for detailed, precise 3-D trackreconstructions from reactions of gases and rare isotope beams

2

Page 3: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Motivation● TexAT will rely on simulations for gas properties:

○ Drift Velocity○ Gas Gain

● Verification of simulators needed to provide uncertainties in track reconstruction

● Quantifying accuracy of Garfield++ drift simulation package

3

Page 4: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Approach● Testing four potential target gases for TexAT

○ He+4%CO₂○ He+10%CO₂○ Methane○ Isobutane

● TPC with applied electric field and proportional counters● 5.4MeV alpha particles ionize gas, electrons drift and

undergo Townsend avalanche near wires● Alphas hit Si detector causing timing trigger on wires● Use timing values to determine drift velocity

4

Page 5: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Setup● Voltage applied to field cage

surrounding TPC● Mesh 3mm above wires

○ e⁻ undergo avalanche in region

● Si detector with 6-slit mask across from alpha source○ Defines alpha tracks

5

Page 6: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Data Interpretation● Apply cut around alpha

energy deposits ● Ensures only timing

signals from alphas, not from outside noise

61 Channel = .6mV

Page 7: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Data Interpretation● Fit gaussians to wire

timing, use means to determine drift time

● Drift velocity can be calculated from drift time

● Averaged drift velocity of all 5 wires

7 1 Channel = .25ns

Page 8: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Simulations● Using Garfield++¹ drift

simulation package● Drifting e⁻ in same gas,

pressure, and E-field● Drifting every .5cm up to

10cm above floor● Outputs drift velocity,

timing and position resolutions

8 [1] <http://garfieldpp.web.cern.ch/garfieldpp/>

Page 9: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Results: Helium+CO₂

● 5% systematic uncertainty shown in error bars○ mainly from uncertainty

in E-Field and pressure/temperature

● Exp/Sims:○ He+4%CO₂: 1.12○ He+10%Co₂: 1.07

● Sims slightly underestimate drift velocity

9

Page 10: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Results: Methane

● Best fit of all gases● Exp/Sims: 1.02● Deviations start to occur

at higher E/P values

10

Page 11: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Results: Isobutane

● Systematic deviation apparent in Isobutane

● Experimental data is 18% higher on average

11

Page 12: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Conclusion● Garfield underestimates drift velocities of He+CO₂ mixtures

by 7-12%● Methane had only 2% deviation between experimental and

simulation values● Isobutane exhibited a systematic deviation from simulation

data○ Requires further testing with higher pressures and

different geometry

12

Page 13: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Moving Forward● Further testing of Isobutane gas● Energy gains

○ Analyze data and run simulations● Track reconstruction of alphas and electrons

13

● Special Thanks:○ Dr. Rogachev○ Dr. Koshchiy○ Dr. Uberseder○ Rogachev Group

Page 14: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

14

Page 15: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Results● Both He/CO₂ mixtures

exhibited similar drift velocities and deviations from simulations

● 5% systematic deviation in error bars

● Exp/Sims:○ He4%CO₂: 1.15○ He10%CO₂: 1.10

15

Page 16: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Results● Methane matched

best of all gases● Exp/Sims: 1.03● Some deviations at

lower pressure

16

Page 17: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Evidence for Field Distortion● Wires are consistent with

external alpha source● Deviations increase closer

to source

17

Page 18: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

Evidence for Field Distortion● Individual wires are

compact● Wires spread when alpha

source is moved inside

18

Page 19: detector application gas mixtures for active target ... · Daniel Yates Advisor: Dr. Rogachev. Texas Active Target (TexAT) New active target detector under development by Rogachev

● Surrounding pressures

● With 1.5% air in mixture

19