detailed assets - oceanus offshore · 2015-01-22 · the lightweight, 300m deep diving system named...

18
Detailed Assets List of Diving Equipments available with the company Sr. No. Description Qty 1. Saturation Spread 1 (Six Man Saturation 1 Diving Spread) 2. Saturation Spread 2 - (Twelve Man 1 Saturation Diving Spread) 3. Saturation Spread 3 - (Twelve Man Saturation Diving Spread) 4. Surface Supplied Mixed Gas Diving Spread 002 1 3.1 Containerized Deck Decompression Chamber 1 (Approved by Germanischer Lloyds) 3.2 Three Diver Mixed Gas Panel with Depth 1 Gauges (3D) and High Pressure Regulators (Tescom) 3.3 Rack Mounted two Diver Comms Radio 1 (Amron) 3.4 Underwater Video System, each consisting of 2 3.4.1 LCD screen 1 3.4.2 Power Unit For regulated power supply to 1 Underwater Light and Camera (Oultand Tech) 1 3.4.3 DVD Recorder 1 3.4.4 Underwater Camera (Outland Tech) 1 3.4.5 Underwater Light 1 3.5 Diver Launch and Recovery System consisting 1 of 3.5.1 Hydraulic Man Riding Winch 1 3.5.2 Hydraulic Power Unit 1 3.5.3 Hydraulic Control Console 1 3.5.4 A - Frame 1 3.5.5 Hydraulic Cylinders 2 3.5.6 Wire Rope 1 3.5.7 Diving Cage with Air Cylinder 1 3.6 Secondary Recovery System consisting of 1 3.6.1 Hydraulic Man Riding Winch 1 3.6.2 Clump Weight with Tool Basket 1 3.7 Gas Container Consisting of 1 3.7.1 L P Compressor 2 3.7.2 H P Compressor 1 3.7.3 Air Receiver (500 liters.) 1 3.7.4 9 Cylinder Air Quads 2 3.7.5 Crane - SWL 1.5 tons 1 5. Surface Supplied Mixed Gas Diving Spread 003 1 4.1 Combo of LARS and DDC consisting of 1 4.1.1 Diver Launch and Recovery System consisting 1 of 4.1.1.1 Hydraulic man Riding Winch 1 4.1.1.2 Hydraulic Power Unit 1 4.1.1.3 Hydraulic Control Console 1

Upload: others

Post on 02-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

Detailed Assets

List of Diving Equipments available with the company

Sr. No. Description Qty

1. Saturation Spread 1 – (Six Man Saturation 1 Diving Spread)

2. Saturation Spread 2 - (Twelve Man 1

Saturation Diving Spread)

3. Saturation Spread 3 - (Twelve Man Saturation

Diving Spread)

4. Surface Supplied Mixed Gas Diving Spread 002 1

3.1 Containerized Deck Decompression Chamber 1 (Approved by Germanischer Lloyds)

3.2 Three Diver Mixed Gas Panel with Depth 1 Gauges (3D) and High Pressure Regulators

(Tescom)

3.3 Rack Mounted two Diver Comms Radio 1 (Amron)

3.4 Underwater Video System, each consisting of 2 3.4.1 LCD screen 1 3.4.2 Power Unit For regulated power supply to 1

Underwater Light and Camera (Oultand Tech) 1 3.4.3 DVD Recorder 1 3.4.4 Underwater Camera (Outland Tech) 1

3.4.5 Underwater Light 1

3.5 Diver Launch and Recovery System consisting 1 of

3.5.1 Hydraulic Man Riding Winch 1 3.5.2 Hydraulic Power Unit 1 3.5.3 Hydraulic Control Console 1

3.5.4 A - Frame 1 3.5.5 Hydraulic Cylinders 2

3.5.6 Wire Rope 1 3.5.7 Diving Cage with Air Cylinder 1

3.6 Secondary Recovery System consisting of 1

3.6.1 Hydraulic Man Riding Winch 1 3.6.2 Clump Weight with Tool Basket 1

3.7 Gas Container Consisting of 1

3.7.1 L P Compressor 2 3.7.2 H P Compressor 1 3.7.3 Air Receiver (500 liters.) 1

3.7.4 9 Cylinder Air Quads 2 3.7.5 Crane - SWL 1.5 tons 1

5. Surface Supplied Mixed Gas Diving Spread 003 1

4.1 Combo of LARS and DDC consisting of 1

4.1.1 Diver Launch and Recovery System consisting 1 of

4.1.1.1 Hydraulic man Riding Winch 1

4.1.1.2 Hydraulic Power Unit 1 4.1.1.3 Hydraulic Control Console 1

Page 2: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

4.1.1.4 A - Frame 1 4.1.1.5 Hydraulic Cylinders 2 4.1.1.6 Wire Rope 1 4.1.1.7 Two Man Diving Cage with two Air 1

Cylinders, two Mixed Gas Cylinders 4.1.2 Secondary Recovery System consisting of 1

4.1.2.1 Hydraulic Man Riding Winch 1 4.1.2.2 Clump Weight with tool basket 1

4.1.3 Deck Decompression Chamber (Approved by 1

Germanischer Lloyds)

4.2 Dive Control Container consisting of 1 4.2.1 Three Diver Mixed Gas Panel 1

4.2.2 Two Diver Rack Mounted Comms Radio 1 (Amron)

4.2.3 Desktop 2 4.2.4 Printer - Scanner (All in One) 1 4.2.5 Underwater Video System, each consisting of 2

4.2.5.1 LCD screen 1 4.2.5.2 Power Unit For regulated power supply 1

to Underwater Light and Camera (Oultand Tech)

4.2.5.3 DVD Recorder 1

4.2.5.4 Underwater Camera (Outland Tech) 1 4.2.5.5 Underwater Light 1

4.3 Gas Container Consisting of 1 4.3.1 L P Compressor 2 4.3.2 H P Compressor 1 4.3.3 Air Receiver (500 liters) 1

4.3.4 9 Cylinder Air Quads 2

6. Surface Supplied Mixed Gas Diving Spread 004 1

5.1 Combo of LARS and Dive Control consisting 1 of

5.1.1 Diver Launch and Recovery System consisting 1 of

5.1.1.1 Hydraulic man Riding Winch 1 5.1.1.2 Hydraulic Power Unit 1 5.1.1.3 Hydraulic Control Console 1

5.1.1.4 A - Frame 1 5.1.1.5 Hydraulic Cylinders 2

5.1.1.6 Wire Rope 1 5.1.1.7 Two Man Diving Cage with two Air 1

Cylinders, two Mixed Gas Cylinders

5.1.2 Secondary Recovery System consisting of 1 5.1.2.1 Hydraulic Man Riding Winch 1

5.1.2.2 Clump Weight with tool basket 1 5.1.3 Dive Control consisting of 1

5.1.3.1 Three Diver Mixed Gas Panel 1

5.1.3.2 Two Diver Rack Mounted Comms Radio 1 (Amron)

5.1.3.3 Underwater Video System, each 2

Page 3: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

consisting of

5.1.3.3.1 LCD screen 1 5.1.3.3.2 Power Unit For regulated 1

power supply to Underwater

Light and Camera (Oultand Tech)

5.1.3.3.3 DVD Recorder 1 5.1.3.3.4 Underwater Camera (Outland 1

Tech)

5.1.3.3.5 Underwater Light 1

5.2 Containerized Deck Decompression Chamber 1 (Approved by Germanischer Lloyds)

5.3 Three Diver Mixed Gas Panel with Depth 1

Gauges (3D) and High Pressure Regulators (Tescom)

5.4 Rack Mounted two Diver Comms Radio 1 (Amron)

5.5 Underwater Video System, each consisting of 2 5.5.1 LCD screen 1

5.5.2 Power Unit For regulated power supply to 1 Underwater Light and Camera (Oultand Tech) 1

5.5.3 DVD Recorder 1

5.5.4 Underwater Camera (Outland Tech) 1 5.5.5 Underwater Light 1

5.6 Gas Container Consisting of 1 5.6.1 L P Compressor 2 5.6.2 H P Compressor 1

5.6.3 Air Receiver (500 liters.) 1 5.6.4 9 Cylinder Air Quads 2

7. Surface Supplied Mixed Gas Diving Spread 005 1

6.1 Combo of DDC, LARS, Gas Container and 1 Dive Control consisting of

6.1.1 Diver Launch and Recovery System consisting 1 of

6.1.1.1 Hydraulic man Riding Winch 1 6.1.1.2 Hydraulic Power Unit 1 6.1.1.3 Hydraulic Control Console 1

6.1.1.4 A - Frame 1 6.1.1.5 Hydraulic Cylinders 2

6.1.1.6 Wire Rope 1 6.1.1.7 Two Man Diving Cage with two Air 1

Cylinders, two Mixed Gas Cylinders

6.1.2 Secondary Recovery System consisting of 1 6.1.2.1 Hydraulic Man Riding Winch 1

6.1.2.2 Clump Weight with tool basket 1 6.1.3 Deck Decompression Chamber (Approved by 1

Germanischer Lloyds) 6.1.4 Dive Control consisting of 1

6.1.4.1 Three Diver Mixed Gas Panel 1

6.1.4.2 Two Diver Rack Mounted Comms Radio 1

Page 4: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

(Amron)

6.1.4.3 Underwater Video System, each 2 consisting of 6.1.4.3.1 LCD screen 1

6.1.4.3.2 Power Unit For regulated 1 power supply to Underwater

Light and Camera (Oultand Tech)

6.1.4.3.3 DVD Recorder 1

6.1.4.3.4 Underwater Camera (Outland 1 Tech)

6.1.4.3.5 Underwater Light 1 6.1.5 Gas Container Consisting of 1

6.1.5.1 L P Compressor 2

6.1.5.2 H P Compressor 1 6.1.5.3 Air Receiver (500 liters.) 1

6.1.5.4 9 Cylinder Air Quads 2

8. Surface Supplied Mixed Gas Diving Spread 006 1

7.1 Containerized Deck Decompression Chamber 1 (Approved by Germanischer Lloyds)

7.2 Three Diver Mixed Gas Panel with Depth 1

Gauges (3D) and High Pressure Regulators (Tescom)

7.3 Rack Mounted two Diver Comms Radio 1 (Amron)

7.4 Underwater Video System, each consisting of 2 7.4.1 LCD screen 1

7.4.2 Power Unit For regulated power supply to 1 Underwater Light and Camera (Oultand Tech) 1

7.4.3 DVD Recorder 1

7.4.4 Underwater Camera (Outland Tech) 1 7.4.5 Underwater Light 1

7.5 Diver Launch and Recovery System consisting 1 of

7.5.1 Hydraulic Man Riding Winch 1 7.5.2 Hydraulic Power Unit 1

7.5.3 Hydraulic Control Console 1 7.5.4 A - Frame 1

7.5.5 Hydraulic Cylinders 2 7.5.6 Wire Rope 1 7.5.7 Diving Cage with Air Cylinder 1

7.6 Secondary Recovery System consisting of 1 7.6.1 Hydraulic Man Riding Winch 1 7.6.2 Clump Weight with Tool Basket 1

7.7 Gas Container Consisting of 1 7.7.1 L P Compressor 2 7.7.2 H P Compressor 1

7.7.3 Air Receiver (500 liters.) 1 7.7.4 9 Cylinder Air Quads 2

9. Deck Decompression Chamber (Approved from 2

Page 5: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

Germanischer Lloyds)

10. Hydraulic Power Units 1

11. Pneumatic Winches 5

12. L P Compressor 4

13. Grit Blaster / Hupper with Hose 2

14. Underwater Video System with 10

13.1 LCD screen

13.2 Power Unit For regulated power supply to Underwater Light and Camera (Oultand Tech)

13.3 DVD Recorder

13.4 Underwater Camera (Outland Tech)

13.5 Underwater Light

15. Diving Comms Radio - Portable 3/ 2 Diver (Amron) 10

16. KirloskarGenset - 62.5 kVA 1

17. KirloskarGenset - 250 kVA 1

18. Portable two Diver Air Diving Panel 2

19. Equipment Launch and Recovery System 3

20. Scuba Replacement Unit 1

21. Zodiac with Outboard Motor 8

22. Fiber Boat 3

23. M P I Unit 1

24. C P Unit 1

25. U T Meter 1

26. Air Quads 2

27. Oxygen Quad 5

28. Mixed Gas Quad 6

29. Diving Helmets

27.1 Kirby Morgan Superlite - 17 B with Ultrajewel 2

601 reclaim valve

27.2 Kirby Morgan Superlite - 17 C with Ultrajewel 4 601 reclaim valve

27.3 Kirby Morgan Superlite - 17 C 4

27.4 Kirby Morgan Superlite - 37 9

27.5 Kirby Morgan Superlite - 27 1

27.6 Kirby Morgan Bandmask - 18 4

27.7 Kirby Morgan Bandmask - 28 4

30. Scuba Cylinders 9

31. Diving Umbilical with comms cable and video cable 12

32. Fire Extinguisher 2

33. CRT Monitors 3

34. Scuba Regulator 8

35. Depth gauge(WIKA ) 10

36. High Pressure Regulator(Tescom ) 25

37. Carbon Dioxide Analyzer (Analox) 1

38. Oxygen Analyzer (Analox) 5

39. Welding Machines 5

40. Crane - SWL 1.5 tons 1

Page 6: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

SATURATION SPREAD 1

1. INTRODUCTION

This document describes the Oceanus Offshore Services owned Six (6) Man

Saturation, 2 Man Bell Diving System after its September 09 upgrade to

bring it in line with all International Marine Contractor’s Association (IMCA)

standards. It is the responsibility of the Asset Manager to keep this

document updated.

2. GENERAL The lightweight, 300m deep diving system named “6 - Man Saturation

Diving System ” is designed to enable 2 divers to work at depths of 150-

350m in Saturation Dive Technique.

The equipment includes a 4 Man living chamber, a closed diving bell, a

pivoting frame and lifting winch, two constant tension winches, two

machinery vans containing two gas regeneration units and a dual divers

hot water unit and a diving /Life Support control cabin. The system also

includes a Hyperbaric Rescue Chamber, which also doubles up as a two

man living chamber and a Hyperbaric Rescue Chamber Control Van. The

“6-Man Saturation Diving System system, due to its compactness

can be very easily and rapidly installed on board ships or rigs.

3. SPECIFICATIONS 3.1 MAIN PARTICULARS AND FEATURES

Certification : Various, a Combination of ABS and Lloyds

Location : Middle East

Saturation Diving System :

Configuration : 2 Main Modules + Sundry items Design Rating : 200 MSW

Depth Rating : 200 MSW Manning Level : 6 Divers

Chamber Complex : 2 x Living Chambers : 2 x Transfer Chambers

Diver Rescue : 8 Man Hyperbaric Rescue Chamber

Diving Bell (Side Mating) : 2.7 Cu Mtr2 Man Diving Bell System Floodable Volume (aprox) : 26 Cu Mtr

Bell Deployment Frame : Fully articulated, Suitable for Moonpool or Over the Side

Bell Handling System : Electro Hydraulic

Emergency Bell Handling : Pneumatic Diver Heating : Electrically Powered (Calorifier)

Diver Gas Recovery : Yes ECU Systems : External Life Support Package (LSP) : Containerised, c/w Heating, Cooling,

Gas Management etc.

Gas Management System : N/A

Page 7: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

In Built Gas Storage : N/A

3.2 TECHNICAL CHARACTERISTICS

This main module groups together on the same platform consisting of a 30

bar decompression chamber, a 200 meter diving-bell and its handling and

lifting systems. It also contains a second two man living chamber which

also doubles up as an eight man HRC for diver rescue in times of

emergencies. It also includes all ancillary equipment to safely carry out

extended saturation diving operations.

3.2.1 Diver Transport

The SDC is a 200 meter diving-bell with an internal and external working

pressure of 20 bars. The bell mates onto the chamber by horizontal hub,

divers’ exit via vertical hub. Electrical supply and communications are

provided by means of the Electro mechanical cable in the main bell

umbilical. Gas is supplied by means of the main bell umbilic al with back up

gas supplied from 8 onboard gas cylinders mounted on the outside of the

diving-bell. Hot water can be supplied from the surface for divers hot water

suits Electrical heating of the divers’ suits.

3.2.2 Hyperbaric Rescue Chamber and Control Van

The system includes a Hyperbaric Rescue Chamber and a separate

Control Van which is embarked on a separate standby vessel or on land if

close enough. The HRC CV provides the facility to manage the HRC when

it has been deployed. It contains the necessary panels, communications

and analysis equipment to be able to monitor and control the

decompression of divers and to control the environment inside the HRC.

It also contains the hoses and interconnect cables required to mate with

the HRC. The system also requires that sufficient gas is stored with the

HRC CV to enable treatment and decompression of the divers.

The HRC is monitored in normal operations through the Saturation CV

and can be deployed by a number of means including a gravity

deployment system if the height is not too great or by crane.

3.2.3 Compression and decompression

Internal working pressure of chamber is 30 bar. Internal diameter 1,800mm x

length 3,800mm. Main chamber contains four beds. The decompression chamber is equipped with two separate control panels (one for the main chamber and one for the lock) for the gas, power and communications systems. The mating of the diving-bell to the decompression chamber is

carried out by a manual clamp with a pneumatic safety interlock that prevents accidental removal of the clamp and depressurization of the bell and or chamber hydraulic clamp.

The second living chamber consists of two bunks. The mating of the first chamber to second chamber is carried out with a clamp in a similar manner as

stated above.

3.2.4 Handling System

The diving-bell is transferred from the decompression chamber to the

dive position by means of a pivoting hydraulic handling A Frame. (The

pivoting movement functions by means of hydraulic rams). The hydraulic

Page 8: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

lifting winch of 4.OT has a speed of 20m/min. The diving-bell is guided

by guide lines maintained in constant tension by pneumatic winches.

3.2.5 Standard Equipment

The system comes complete with a colour video system with video

overlay, full analysis capability, a complete array of helium unscrambler

radios for diving and life support functions as well as a full range of tools

and spares for the system equipment.

3.2.6 Support Service Requirements

Main Power : 440v x 50 / 60 Hz x 350 kVA EmgyPower : 440v x 50 Hz x 250 kVA: Utility Air : 500

CFM @ 6 Bar: Salt Water : 60 ltrs/Min @ 3 Bar Min: Potable Water: 25ltrs/min for short periods through the day Hook up to Vessel: Phone, PA, Vessel Alarms Etc:

3.2.7 Principle Dimensions

Main Module: 6.65m L x 2.5m W x 3.8m H x 21

tonnes

Second Living Chamber / HRC: 4.5m L x 2.5m W x 2.8m H x 11

tonnes

Control Van:

Machinery Van 1:

tonnes

(Regeneration Units)

Machinery Van 1:

(Hotwater Units, chiller units

And Diver Gas Reclaim Unit)

4. SPECIFICATIONS

Road transportable

200mtr Capability

Facilities for 6 divers

2 x Living Chambers

2 x Transfer Chambers

6.4m L x 2.4m W x 2.4m H x 5 tonnes

6.4m L x 2.4m W x 2.4m H x 11

6.4m L x 2.4m W x 2.4m H x 5 tonnes

8 man Hyperbaric Rescue Chamber

2 Man diving Bell Electro Hydraulic Bell Handling System

Pneumatic Emergency Bell Handling System

Diver Heating Electric Calorifier

Diver Gas Recovery. Air Powered Gas Reclaim System

Power and Services Required

Page 9: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

SATURATION SPREAD 2

1. Scope The scope of this document is to give a short description of the

equipment known as the 12 Man Portable Saturation Dive System. It

is not intended to be a set of operating instructions nor a detailed

breakdown of system components.

2. Introduction This short introduction has been structured to include a general

description and specifications of the unit involved.

3. Description 3.1 MAIN PARTICULARS AND FEATURES

Certification : Various, a Combination of ABS,

Lloyds & DNV Location : Singapore

Saturation Diving System : Configuration : 3 Main Modules + Sundry items

Design Rating : 200 MSW Depth Rating : 200 MSW

Manning Level : 12 Divers Chamber Complex : 2 x Living Chambers

: 2 x Transfer Chambers

Diver Rescue : 12 Man Hyperbaric Rescue Lifeboat (SPHL)

Diving Bell (Side Mating) : 4.5 Cu Mtr 3 Man Diving Bell System Floodable Volume (aprox) : 65 Cu Mtr Bell Deployment Frame : Fully articulated, Suitable for

Moonpool or Over the Side Bell Handling System : Electro Hydraulic (incl. Pneumatic

Lateral Translation Trolley) Emergency Bell Handling : Diesel Hydraulic Diver Heating : Electrically Powered (Calorifier)

Diver Gas Recovery : Yes ECU Systems : External

Life Support Package (LSP) : Containerised, c/w Heating, Cooling, Gas Management etc.

Gas Management System : N/A

In Built Gas Storage : N/A 3.2 SATURATION DIVING SYSTEM

The Saturation Diving System is Fully Certified, it supports up to 12 divers in

saturation at depths of up to 200 MSW, it also conforms to all the legislation requirements of the UK HSE and IMCA.

Page 10: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

The diving system pressure envelope comprises a 9 man, 32 Cu Mt, single lock chamber, a 3 man, twin lock chamber, a vertical transfer lock, a 12 Man SelfPropelled Hyperbaric Lifeboat (SPHL) and a side mating 3 man Bell.

The basic layout of the diving system & chambers are mounted on 2 large lifting frames (Bell Handling Module & Chamber Module) + lifeboat davit & support frame, all suitable for installation on an open deck.

The complex allows for up to 4 teams of divers to operate at the same or different

depths optionally 3 teams whilst a fourth team is simultaneously decompressing. The 3 Man diving Bell is deployed by means of a fully articulated A Frame c/w

lateral translation trolley. Each team of divers has access to the diving bell via

the transfer lock The Diving System Chamber Complex is monitored and controlled from a 2-

compartment purpose built containerised control room. The control room is located on the upper level of the Bell handling module, here the environment in each chamber compartment is monitored. Decompression, pressure monitoring,

analysis; communications etc are also controlled from dedicated panels & instruments in this control room. In addition a central communications station is provided allowing full connections with all the chamber compartments

The accommodation compartments of the chambers are outfitted with bunks & curtains, seating and table as well as fire fighting equipment, BIBS, emergency life support equipment incl. internal monitoring. Additionally all divers inside have access to individual bunk lights, talk back speakers and monitoring

equipment. An audio entertainment system is provided for diver comfort The transfer locks are outfitted with toilet, hand basin and showering facilities, these compartments are also provided with emergency equipment similar to the

main compartments. Pre-regulated cold & heated sanitary water is provided to each of the transfer locks. Life support and environmental control for the chamber complex is provided

both internally and externally by means of specialised proprietary equipment. Over capacity in this area ensures redundancy in the case of breakdown or

maintenance requirement. The ECU Eqpt is housed in purpose built containers and are located on the upper level of the Chamber Module

The diving bell has a volume of 4.5 m3 and is outfitted for 3 divers. The diving

bell has double acting bayonet action single doors on the side and bottom; these

seal both internally & externally. The bell is negatively buoyant and has a passive telescopic retractable work stage incorporated into its crash frame to

ensure that there is a fixed stand off. Procedures for Emergency Seabed Intervention will require to be developed by users

Dive Control is housed in the second compartment of the Containerised Control Room; it has windows from which diving bell deployments may be observed, it

houses all monitors, indicators and other essential services necessary to ensure safe efficient bell diving operations. Diving bell hoisting operations are controlled from this location. Emergency intervention air diver is catered for. The Diving Bell Handling System is fully articulated and suitable for operation

over the side or in conjunction with a moonpool. The Diving bell is connected to the handling system via the non rotating hoist wire, there is a composite

umbilical which allows all normal and essential services to support the bell and its occupants, and the diving bell has through water communications. The diving bell is outfitted internally with all necessary safety and emergency equipment,

including an industry standard Diver Gas Recovery System, the diving bell

Page 11: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

external outfit is also fully compliant with all ruling regulat ions and

requirements, and includes facilities and connections for hook up of an emergency umbilical. Hydraulically Powered Winches are employed for hoisting & lowering the bell

and for the deployment & recovery of the Guide Weight and the Composite Umbilical.

Diver heating is accomplished by means of a large capacity electrically powered

calorifier system. A stored volume of water ensures a good factor of redundancy.

A 12 man SelfPropelled Hyperbaric Rescue Lifeboat (SPHL) is provided for the emergency escape or transfer of divers. The SPHL is handled overboard by means

of a dedicated Pivot Arm “Gravity” Davit Handling System with built- in stored energy. The SPHL hull, machinery, equipment, manoeuvrability and seagoing properties comply with the relevant MSA & SOLAS codes and it can provide life

support for up to 72 hours, once recovered this duration can be further extended if need be with the aid of an Emergency Support Package. The lifeboat cockpit has space for all essential personnel inc‟l the coxswain, a Technician and a chamber

operator. Access to the SPHL Chamber is achieved by means of a trunking connected to one of the chamber spare manways. The SPHL chamber has a self contained

heating system, and a cooling system is powered from the lifeboat engine. The SPHL has the benefit of a recent Thermal Evaluation, heating & cooling

capacities comply with the requirements of the current IMCA Guidelines. The SPHL chamber has a provisioning lock, viewport & all-necessary safety and emergency facilities required for preserving life. During normal operation the

SPHL chamber is controlled from a panel in Saturation Control and is interfaced with the diving system by means of a quick connect umbilical. In emergency it

operates autonomously. The SPHL carries reserves of Heliox& Metabolic Oxygen Gasses, as well as all necessary safety and emergency facilities required for the preservation of life

Typical Support Services Required Main Power 440v x 60hz x 500Kva:

Emgy Power 440v x 60hz x 250Kva: Utility Air 500 CFM @ 6 Bar: Salt Water 15 Imp Gal/Min @ 3 Bar Min:

Potable Water 150Imp Gal/Day: Hook up to Vessel: Phone, PA, Vessel Alarms Etc:

Page 12: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

System Lift Weight and Dimensions

Dimension Bell Module Chamber Module SPHL with SPHL

Transit Frame Deployment

Frame

Length 13.74 m 8.40 m 9.80 m 8.98 m

Width 4.82 m 7.92 m 3.70 m 3.75 m

Height 9 m 8 m 3.44 m 10 m

Lift Weight 90 MT 60 MT 12.2 MT 22 MT

Chamber DDC 1 DDC 2 TUP SDC SPHL

Volume (9 man) (3 man)

Cu. M 32.8 11 7.26 4.5 6.38 Diving System Floodable Volume: 65 Cu Mtr

Bell bottomManway: 700mm Dia

4. Specifications

Not Road transportable

200mtr Capability

Facilities for 12 divers

2 x Living Chambers

2 x Transfer Chambers

12 man Hyperbaric Rescue Lifeboat (SPHL)

3 Man diving Bell

Electro Hydraulic Bell Handling System

Diesel Hydraulic Emergency Bell Handling System

Diver Heating Electric Calorifier

Diver Gas Recovery. Air Powered Gas Reclaim System

Power and Services Required

Page 13: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

5. Basic layout of the system

Page 14: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

SATURATION SPREAD 3

1. INTRODUCTION

This introduction has been structured to include a general description and

specifications of the unit involved.

2. DESCRIPTION

2.1 MAIN PARTICULARS AND FEATURES

Saturation Diving System :

Configuration : 3 Main Modules + 3 20’

Container + Sundry

items

Test Rating : 300 MSW

Depth Rating : 200 MSW

Manning Level : 12 Divers

Chamber Complex : 2 x Living Chambers

: 1 x Transfer Chambers

Diver Rescue : 3men Living /12 Men HRC

Diving Bell (Side Mating) : 3 Man Diving Bell

Bell Deployment Frame : Fully articulated,

Suitable for

Moonpool and side launching.

Bell Handling System : Hydraulic

Emergency Bell Handling : Pneumo

Diver Heating : Electrically Powered

Diver Gas Recovery : Yes (Gas Services)

ECU Systems : Three external units

Life Support Package (LSP) : Containerized, c/w Heating,

Cooling, Gas, Management etc.

2.2 SATURATION DIVING SYSTEM

The Saturation Diving System is Fully Certified by ABS Certification

Society, it supports up to 12 divers in saturation at depths of up to

200 MSW, it also confirms to all the legislation requirements of the

UK HSE and IMCA.

The diving system pressure envelope comprises a 6 man, single lock

chamber, a 3 men, single lock chamber, 5.5 Cu Mt transfer lock, a 3

men living/ 12men, Hyperbaric Rescue Chamber and a side mating, 5.85 Cu Mt, 3 men Bell.

The basic layout of the diving system & chambers are mounted on 2

large lifting frames (Bell Handling Module & Chamber Module) + HRC,

all suitable for installation on an open deck.

The complex allows for up to 4 teams of divers to operate at the

same or different depths optionally 3 teams whilst a fourth team is

simultaneously decompressing.

The 3 Men diving Bell is deployed by means of a fully articulated A

Frame c/w lateral translation trolley. Each team of divers has access to

the diving bell via the transfer lock

The Diving System & Chamber Complex is monitored and controlled

from a purpose built containerized control rooms. Decompression,

pressure monitoring, analysis; communications etc are also

Page 15: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

controlled from dedicated panels & instruments in this control room. In

addition a central communications station is provided allowing full

connections with all the chamber compartments

The accommodation compartments of the chambers are outfitted with

bunks & curtains, seating and table as well as fire fighting

equipment, BIBS, emergency life support equipment incl. internal

monitoring. Additionally all divers inside have access to individual bunk

lights, talk back speakers and monitoring equipment. An audio

entertainment system is provided for diver comfort.

The transfer locks are outfitted with toilet, hand basin and showering

facilities, these compartments are also provided with emergency

equipment similar to the main compartments. Pre-regulated cold &

heated sanitary water is provided to each of the transfer locks.

Life support and environmental control for the chamber complex is

provided both internally and externally by means of specialized

proprietary equipment. Over capacity in this area ensures

redundancy in the case of breakdown or maintenance requirement.

The ECU is housed in purpose built containers.

The diving bell outfitted for 3 divers. The diving bell has double

acting bayonet action single doors on the side and bottom; these seal

both internally & externally. Procedures for Emergency Seabed

Intervention will require to be developed by users

Dive Control is housed in Containerized Control Room; it has

windows from which diving bell deployments may be observed, it

houses all monitors, indicators and other essential services necessary to

ensure safe efficient bell diving operations. Diving bell hoisting

operations are controlled from this location. Emergency intervention air

diver is catered for.

The Diving Bell Handling System is fully articulated and suitable for

moon pool or side launch. The Diving bell is connected to the

handling system via the non rotating hoist wire, there is a composite

umbilical which allows all normal and essential services to support

the bell and its occupants, and the diving bell has through water

communications. The diving bell is outfitted internally with all

necessary safety and emergency equipment, including an industry

standard Diver Gas Recovery System, the diving bell external outfit is

also fully compliant with all ruling regulations and requirements, and

includes facilities and connections for hook up of an emergency

umbilical.

Hydraulically Powered Winches are employed for hoisting & lowering

the bell and for the deployment & recovery of the Guide Weight and

the Composite Umbilical.

Diver heating is accomplished by means of a electrically powered

system.

A 12 man HRC is provided for the emergency escape or transfer of

divers. Once recovered this duration can be further extended if need

be with the aid of an Emergency Support Package.

Page 16: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

Access to the HRC is achieved by means of a trunking connected to

TUP manway. The HRC has a self contained heating system, and a

cooling system is powered from Battery Pack. The HRC has the

benefit of a recent Thermal Evaluation, heating & cooling capac ities

comply with the requirements of the current IMCA Guidelines. The

HRC chamber has a provisioning lock, viewport & all necessary safety

and emergency facilities required for preserving life. During normal

operation the HRC is controlled from a panel in Saturation Control

and is interfaced with the diving system by means of a quick connect

umbilical.. The HRC carries reserves of Heliox& Metabolic Oxygen

Gasses, as well as all necessary safety and emergency facilities

required for the preservation of life

Typical Support Services Required

Main Power :

Emgy Power :

Utility Air

Salt Water :

Potable Water :

Hook up to Vessel:

3. SPECIFICATIONS

Road transportable

200mtr Capability

Facilities for 12 divers

3 x Living Chambers

1 x Transfer Chambers

440v x 60hz x 500Kva

440v x 60hz x 250Kva

: 500 CFM @ 6 Bar

15 Imp Gal/Min @ 3 Bar Min

150Imp Gal/Day

Phone, PA, Vessel Alarms Etc

12 Hyperbaric Rescue Chamber

3 Man diving Bell

Pneumatic Hydraulic Emergency Bell Handling System

Diver Heating Electric

Diver Gas Recovery. Air Powered Gas Reclaim System Power and Services Required

4. ENVIRONMENTAL CONTROL UNITS (CMU)

Three Kinergetics CMU-2 external units are installed, one for Chamber 2

and two for Chamber 1. Quick disconnect hose connections and a patch

panel for the sensor connections are fitted for convenience of changeover.

Remote control of the ECS is available on the chamber environmental

control panel in the saturation control room in respect of temperature and

humidity. The TUP and work chamber are supplied heated fluid from the

emergency environmental system.

The environmental control system (ECS) consists of 2 major assemblies:

Control Master Unit (CMU).

Habitat Conditioning Unit (HCU)

The CMU’s provides fluid for temperature (primary circuit) and humidity

(secondary circuit) control. The CMU comprises a condensing refrigeration

system, a fluid heating system, primary f luid pump, secondary fluid pump,

associated mixing valves and electronic controls to allow automation.

The HCU’s are installed in the chamber and translate fluid input into

Page 17: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work

heating, cooling and dehumidification functions. Gas is circulated through

the HCU by means of electrically powered blowers, the primary electrical

fan blows gas across the primary heat exchanger and on through the soda

lime canister. The secondary electrical blower blows gas across the

secondary heat exchanger to dehumidify the gas. A water trap is situated

under the unit to catch condensed water for locking out of the chamber.

Note: The units fitted are modified Kinergetics HCU-3-4 units; the normal

water driven motor is replaced by 2 electrically powered motors. The

modification was designed and carried out by Clearbrook Engineering.

5. VOLUME TANKS FOR HOT & COLD WATER

Each chamber is supplied with both hot and cold water from the domestic

hot and cold water tanks. There is 1 hot water tank and 1 cold water tank

in the chamber complex; the tanks are supplied from the water main.

Once the tanks are filled, regulated gas is used to pressurise the tank

forcing the water out the bottom of the tank into the chamber. The hot

water tank has an immersion heater, with thermostat, fitted to heat the

water. Check valves are fitted to prevent back pressurising the water

main. The cold water tank also supplies the humidifier in the work

chamber. The water is supplied to the chamber sinks and shower through

isolation valves.

6. VOLUME TANK FOR SANITARY SYSTEM 6.1 SANITATION

All toilet waste is piped to the waste holding tank which is used to

vent off the pressure and then emptied into an external waste tank.

6.2 BILGE DRAINS

All the bilge and sink drains are piped to the same waste holding

tank as the sanitation waste.

Page 18: Detailed Assets - Oceanus Offshore · 2015-01-22 · The lightweight, 300m deep diving system named “6 - Man Saturation Diving System ” is designed to enable 2 divers to work