Terms of Reference for the Provision of
Microwave Radio Links
National Maritime Safety Authority(NMSA)
PROJECT/TASK TITLE: Supply and installation of microwave communication links for the
Global Maritime Distress and Safety System project in Port Moresby
National Capital District
EXECUTING AGENT: National Maritime Safety Authority
IMPLEMENTING AGENT: National Maritime Safety Authority
PROJECT SPONSOR: CEO
PROJECT LOCATION: MMI Building, Port Moresby to Telikom Tower, Paga Hill
MMI Building, Port Moresby to PNGASL’s Control Tower, Jackson
Airport.
MMI Building, Port Moresby to PNGASL’s HF Transmitter, Taldora
site at seven (7) mile
COMMENCEMENT DATE: June 2014
PROJECT DURATION: 8 weeks for the supply and installation of equipment
![Page 2: Detail ToR for Provision of Microwave Radio Link](https://reader037.vdocuments.us/reader037/viewer/2022100506/577c84221a28abe054b7a02d/html5/thumbnails/2.jpg)
8/19/2019 Detail ToR for Provision of Microwave Radio Link
http://slidepdf.com/reader/full/detail-tor-for-provision-of-microwave-radio-link 2/4
INTRODUCTION/BACKGROUND
NMSA has proposed to install microwave radio link for the GMDSS project in Port Moresby. The
microwave radio links are to connect the following location:
MMI Building, Port Moresby to Telikom Tower, Paga Hill MMI Building, Port Moresby to PNGASL’s Control Tower, Jackson Airport.
MMI Building, Port Moresby to PNGASL’s HF Transmitter, Taldora site
OBJECTIVE
NMSA’s Global Maritime Distress and Safety System Project requires microwave radio link to
connect the high frequency transmitter, and receiver and to be available on a 24/7 basis.
The link will be utilize to remotely control the transmitters and the receivers from the operations
centre located at the Pacific MMI building.
CONSTRAINTS
The transmitters and receivers for the Coastal Radio Station will be remotely controlled from the
Pacific MMI building in town, the selected frequencies should be taken into consideration when
designing the solution.
The equipment offered should have support in PNG with 99.999% uptime must be taken into
consideration when presenting the solution.
REQUIREMENTS FOR THE MICROWAVE LINK PROVIDER
By accepting the Terms of Reference (ToR), the microwave link provider confirms that it meets the
following condition: The provider has a valid dealers licence with the National Information Communication
Technology Authority (NICTA)
The provider is committed to undertake this engagement in accordance with International
best practices and standards.
The engaging firm must be currently registered, as required under the PNG Companies Act
1997, and must always comply with the requirements and guidelines of Investment
Promotion Authority (IPA)
The engaging firm must comply with all tax requirements, as required by the Internal
Revenue Commission (IRC) and must have a current operating Certificate of Compliance
(CoC).
QUALIFICATIONS AND EXPERIENCE
The Providers are expected to be technically qualified and experienced in the field of communication
and ICT. They are expected to provided a turn-key solution which is both robust and can be able to
operate in the harshest of PNG conditions.
SCOPE OF WORKS
The Turn key solution provided by the vendors should cater for all the elements of a microwave
communication system taking into account the nature of the GMDSS project.
SCOPE OF WORK AND REQUIREMENTS
![Page 3: Detail ToR for Provision of Microwave Radio Link](https://reader037.vdocuments.us/reader037/viewer/2022100506/577c84221a28abe054b7a02d/html5/thumbnails/3.jpg)
8/19/2019 Detail ToR for Provision of Microwave Radio Link
http://slidepdf.com/reader/full/detail-tor-for-provision-of-microwave-radio-link 3/4
The sites will be in Port Moresby and the microwave links are required to operate 24/7 basis. The
Link specifications are as follows:
Radio Link Specifications:
1.
Licensed Spectrum: as per ITU-R Rec.F.636
Frequency Band: 14.5-15.35 GHz 30 45 55
Point-to-point
Low – medium capacity
ITU-R Rec.F.636
2.
Channel Size: as per ITU-R Rec.F.636
3.5 MHz, 7 MHz selectable by software
3.
Rx Sensitivity:Threshold at 10-6 BER
3.5 MHz -92.5 dBm
7 MHz -90.5 dBm
4. Tx Power 22.0 dBm
5.
System Gain
System Gain at 10-6 BER
3.5 MHz 114.5 dB
7 MHz 112.5 dB
6. Modulation CPM
7.
Carrier grade QoS policing and prioritization options (802.1p/q)
8. 1+1 Hot Standby
9. Minimum 8 E1 interfaces Compliant to ITU-T Rec. G.703, G.823
10.
Minimum 2 Ethernet interfaces 10/100 Base-T
11.
All paths to be designed to >99.998% annual availability using ITU-R P.530 7/8 and rain data
ITU-R P.530-7, rain algorithm ITU-R P.530-7
12. The power supply will be 48V Sealed Lead Acid Battery with adequate capacity to support
the radio equipment and the associated MUX for a period of at least 5 hours. The charging
system must be fully automatic and suitable to maintain the batteries offered. The batteries
will require mounting shelves in a standard 19 inch rack.
13. Equipment offered should have support in PNG.
EXPECTED OUTCOMES
![Page 4: Detail ToR for Provision of Microwave Radio Link](https://reader037.vdocuments.us/reader037/viewer/2022100506/577c84221a28abe054b7a02d/html5/thumbnails/4.jpg)
8/19/2019 Detail ToR for Provision of Microwave Radio Link
http://slidepdf.com/reader/full/detail-tor-for-provision-of-microwave-radio-link 4/4
The NMSA expects the links to have >99.998% annual availability using ITU-R PP.530 7/8 and rain
data ITU -R P.530-7. Rain algorithm ITU-R P.530-7 service level