design | production creating space for industry
TRANSCRIPT
CREATING SPACE FOR INDUSTRY
D E S I G N | P R O D U C T I O N
T E M P O R A R Y I N D U S T R I A L B U I L D I N G S
A GLOBAL BRAND
HTS tentiQ GmbH is a leading manufacturer of high quality
semi-permanent industrial buildings. Quick and easy to in-
stall and dismantle, our comprehensive product range serves
many diff erent markets including: manufacturing, logistics,
retail, waste, mining, automotive, education, hospitals and
general industry.
The company is driven by innovation and continuous im-
provement, always ensuring we deliver the optimum service
and product lines to our customers worldwide.
For further product information go to: https://www.hts-ind.co.uk
ACCESSORIESPersonnel and vehicle access doors,
windows, heating, ventilation or lighting;
we can supply everything you need.
INSULATED TEMPORARY BUILDINGS
Insulated buildings that minimise
condensation.
NON-INSULATED TEMPORARY BUILDINGS
Uninsulated buildings for general storage
and operational activity.
CANOPIES
Basic weather protection for loading/
unloading operations and storage.
28
20
12
6
CONTENT An overview of our fast, fl exible and economical temporary
structures and accessories.
32
Überdachungen
ABOUT HTS tentiQ
CUSTOM SOLUTIONS FOR ALL APPLICATIONS
HTS tentiQ is the driving force in the temporary buildings
industry. For years we have been the trusted brand for
customers worldwide, offering a wide range of structures,
unrivalled quality, a global presence and innovative ideas.
Our products are designed and manufactured to the
highest standards at our extensive and technically
advanced production facility in Kefenrod, Germany. This
guarantees optimal service levels, stringent quality control,
short delivery times and competitive prices – for all our
customers. German quality at its best.
Our global customer service can fulfil all requirements. When
you contact our team, you will be connected to a technical
expert from our sales network. In-depth product knowledge
and years of experience ensure that you’ll always receive the
product that best suits your requirements.
For further product information go to: https://www.hts-ind.co.uk 54
Überdachungen
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
CANOPY BULDINGS
Our free-standing Canopy Buildings provide fast and
economical space for loading and unloading operations
or basic storage. Taking just days to install, they are the
perfect solution to extend warehouses and operational
capacity quickly and easily.
For further product information go to: https://www.hts-ind.co.uk 76
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
Eave height
Span width 5.00 m 10.00 m 15.00 m 20.00 m 25.00 m 30.00 m
4.20 m Ridge height 5.23 m 6.04 m 6.86 m 7.70 m 8.51 m 9.32 m
5.20 m Ridge height 6.23 m 7.04 m 7.86 m 8.70 m 9.51 m 10.32 m
6.20 m Ridge height 7.23 m 8.04 m 8.88 m 9.70 m 10.51 m 11.32 m
KEY FEATURES
nInstallation of a typical canopy can usually be completed
in under a week.
nEasy to dismantle, remove, extend, modify or relocate
where required.
nAluminium frame, industrial grade PVC roofi ng, steel
sheet or PVC walls.
nRobust, durable and proven through hundreds of
successful loading and storage applications.
nTranslucent PVC roof creates natural light and reduces
lighting costs.
nDesigned to comply with BS6399, DIN EN 13782
(semi-permanent) and DIN EN 1991 (permanent) for
wind and snow loads. Buildings can also be engineered
to site specifi c requirements.
SIZE TABLE – CANOPY BUILDINGSOur Canopy Buildings are available in the following standard sizes.
STANDARD ACCESSORIES – CANOPY BUILDINGS
STRUCTURE SPECIFICATIONS
LENGTHUnlimited length in
5.00 m bays
RIDGE HEIGHT5.23 m - 11.32 m
SNOW LOAD0.52 - 1.25 kN/m2
WIND LOAD0.5 - 0.7 kN/m2
SPAN WIDTH5.00 m - 30.00 m
EAVE HEIGHT4.20 m - 6.20 m
Note: All measurements are standard dimensions. Custom-made solutions can be off ered, subject to static calculations. Higher wind and snow loads are available upon request, dependent on regional requirements.
For further product information go to: https://www.hts-ind.co.uk 98
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
APPLICATION EXAMPLES
NON-INSULATED PVC ROOF BUILDINGS
APPLICATION EXAMPLES
NON-INSULATED STEEL SHEET ROOF BUILDINGS
For further product information go to: https://www.hts-ind.co.uk 1110
Überdachungen
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
NON-INSULATED BUILDINGS
Our Non-Insulated Buildings provide the ideal budget
solution for storage and operational areas that don’t require
temperature control. The roof is manufactured from single layer industrial-grade PVC fabric or corrugated steel sheet panels. The walls can be engineered from corrugated steel
sheets, insulated composite panels or PVC covers. The PVC
roof option offers a high degree of natural light, meaning
lighting costs can be reduced significantly.
For further product information go to: https://www.hts-ind.co.uk 1312
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
Eave height
Span width 5.00 m 10.00 m 15.00 m 20.00 m 25.00 m 30.00 m
4.20 m Ridge height 5.23 m 6.04 m 6.86 m 7.70 m 8.51 m 9.32 m
5.20 m Ridge height 6.23 m 7.04 m 7.86 m 8.70 m 9.51 m 10.32 m
6.20 m Ridge height 7.23 m 8.04 m 8.88 m 9.70 m 10.51 m 11.32 m
nInstallation of a typical non-insulated PVC roof building
can usually be completed in under a week.
nEasy to dismantle, remove, extend, modify or relocate
where required.
nAluminium frame, industrial grade PVC roofing, steel
sheet or PVC walls.
nRobust, durable and proven through hundreds of
successful storage and operational applications.
nTranslucent PVC roof creates natural light and reduces
lighting costs.
nDesigned to comply with BS6399, DIN EN 13782
(semi-permanent) and DIN EN 1991 (permanent) for
wind and snow loads. Buildings can also be engineered
to site specific requirements.
SIZE TABLE - NON-INSULATED ROOF BUILDINGS Our Insulated Roof Buildings are available in the following standard sizes.
STANDARD ACCESSORIES - NON-INSULATED ROOF BUILDINGS
STRUCTURE SPECIFICATIONS
Note: All measurements are standard dimensions. Custom-made solutions can be offered, subject to static calculations. Higher wind and snow loads are available upon request, dependent on regional requirements.
KEY FEATURES
LENGTHUnlimited length in
5.00 m bays
RIDGE HEIGHT5.23 m - 11.23 m
SNOW LOAD0.52 - 1.25 kN/m2
WIND LOAD0.5 - 0.7 kN/m2
SPAN WIDTH5.00 m - 30.00 m
EAVE HEIGHT4.20 m - 6.20 m
For further product information go to: https://www.hts-ind.co.uk 1514
Eave height
Span width 5.00 m 10.00 m 15.00 m 20.00 m 25.00 m 30.00 m
4.20 m Ridge height 5.23 m 6.04 m 6.86 m 7.70 m 8.51 m 9.32 m
5.20 m Ridge height 6.23 m 7.04 m 7.86 m 8.70 m 9.51 m 10.32 m
6.20 m Ridge height 7.23 m 8.04 m 8.88 m 9.70 m 10.51 m 11.32 m
n Installation of a typical non-insulated steel roof building
can usually be completed within 1-2 weeks.
n Easy to dismantle, remove, extend, modify or relocate
where required.
n Aluminium frame, steel sheet roof, steel sheet or PVC
walls.
n Robust, durable and proven through hundreds of
successful storage and operational applications.
n Designed to comply with BS6399, DIN EN 13782 (semi-
permanent) and DIN EN 1991 (permanent) for wind and
snow loads. Buildings can also be engineered to site
specific requirements.
STANDARD ACCESSORIES – NON-INSULATED STEEL SHEET ROOF BUILDINGS
SIZE TABLE - NON-INSULATED STEEL SHEET ROOF BUILDINGSOur Non-Insulated Steel Sheet Roof temporary buildings are available in the following standard sizes.
Note: All measurements are standard dimensions. Custom-made solutions can be offered, subject to static calculations. Higher wind and snow loads are available upon request, dependent on regional requirements. The ridge height may change depending on the depth and type of roofing.
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
KEY FEATURES
STRUCTURE SPECIFICATIONS
LENGTHUnlimited length in
5.00 m bays
RIDGE HEIGHT5.23 m - 11.23 m
SNOW LOAD0.52 - 1.25 kN/m2
WIND LOAD0.5 - 0.7 kN/m2
SPAN WIDTH5.00 m - 30.00 m
EAVE HEIGHT4.20 m - 6.20 m
For further product information go to: https://www.hts-ind.co.uk 1716
APPLICATION EXAMPLES
NON-INSULATED PVC ROOF BUILDINGS
APPLICATION EXAMPLES
NON-INSULATED STEEL SHEET ROOF BUILDINGS
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
For further product information go to: https://www.hts-ind.co.uk 1918
Überdachungen
INSULATED BUILDINGS
Our Insulated Buildings minimise condensation. The roof
panels can either be steel insulated composite panels or our distinctive PVC thermo roof. The Thermo roof is
a double-layered inflatable roof system engineered from
industrial grade PVC fabric. Once inflated it minimises
condensation and reduces structural noise, creating
an ideal solution for goods or equipment that require
protection from condensation.
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
For further product information go to: https://www.hts-ind.co.uk 2120
Eave height
Span width 5.00 m 10.00 m 15.00 m 20.00 m 25.00 m 30.00 m
4.20 m Ridge height 5.23 m 6.04 m 6.86 m 7.70 m 8.51 m 9.32 m
5.20 m Ridge height 6.23 m 7.04 m 7.86 m 8.70 m 9.51 m 10.32 m
6.20 m Ridge height 7.23 m 8.04 m 8.88 m 9.70 m 10.51 m 11.32 m
KEY FEATURES
nInstallation of a typical thermo roof building can usually be
completed in under a week.
nEasy to dismantle, remove, extend, modify or relocate
where required.
nAluminium frame, industrial PVC double-layered roofing
system, steel sheet or insulated composite panel walling.
nRobust, durable and proven through hundreds of
successful applications.
nTranslucent PVC roof creates natural light and reduces
lighting costs.
nDesigned to comply with BS6399, DIN EN 13782 (semi-
permanent) and DIN EN 1991 (permanent) for wind and
snow loads. Buildings can also be engineered to site
specific requirements.
SIZE TABLE - THERMO ROOF BUILDINGS Our Thermo Roof Buildings are available in the following standard sizes.
STANDARD ACCESSORIES - THERMO ROOF BUILDINGS
STRUCTURE SPECIFICATIONS
Note: All measurements are standard dimensions. Custom-made solutions can be offered, subject to static calculations. Higher wind and snow loads are available upon request, dependent on regional requirements.
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
LENGTHUnlimited length in
5.00 m bays
RIDGE HEIGHT5.23 m - 11.23 m
SNOW LOAD0.52 - 1.25 kN/m2
WIND LOAD0.5 - 0.7 kN/m2
SPAN WIDTH5.00 m - 30.00 m
EAVE HEIGHT4.20 m - 6.20 m
For further product information go to: https://www.hts-ind.co.uk 2322
SIZE TABLE - INSULATED COMPOSITE STEEL ROOF TEMPORARY BUILDINGS Our Insulated Buildings with a Steel Composite Roof are available in the following standard sizes:
KEY FEATURES
nInstallation of a typical insulated steel composite roof
building can usually be completed within 2 weeks.
nEasy to dismantle, remove, extend, modify or relocate
where required.
nAluminium frame, insulated steel composite roof (in
various thicknesses), steel sheets or insulated composite
panel walling.
nRobust, durable and proven through hundreds of
successful applications.
nDesigned to comply with BS6399, DIN EN 13782 (semi-
permanent) and DIN EN 1991 (permanent) for wind and
snow loads. Buildings can also be engineered to site
specific requirements.
STANDARD ACCESSORIES - INSULATED COMPOSITE STEEL ROOF
Eave height
Span width 5.00 m 10.00 m 15.00 m 20.00 m 25.00 m 30.00 m
4.20 m Ridge height 5.23 m 6.04 m 6.86 m 7.70 m 8.51 m 9.32 m
5.20 m Ridge height 6.23 m 7.04 m 7.86 m 8.70 m 9.51 m 10.32 m
6.20 m Ridge height 7.23 m 8.04 m 8.88 m 9.70 m 10.51 m 11.32 m
All measurements are standard dimensions. Custom-made solutions can be offered, subject to static calculations. Higher wind and snow loads are available upon request, dependent on regional requirements. The ridge height may change depending on the depth and type of roofing.
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
STRUCTURE SPECIFICATIONS
LENGTHUnlimited length in
5.00 m bays
RIDGE HEIGHT5.23 m - 11.23 m
SNOW LOAD0.52 - 1.25 kN/m2
WIND LOAD0.5 - 0.7 kN/m2
SPAN WIDTH5.00 m - 30.00 m
EAVE HEIGHT4.20 m - 6.20 m
For further product information go to: https://www.hts-ind.co.uk 2524
APPLICATION EXAMPLES
INSULATED TEMPORARY BUILDINGS WITH PVC ROOF
APPLICATION EXAMPLES
INSULATED TEMPORARY BUILDING WITH STEEL ROOF
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
For further product information go to: https://www.hts-ind.co.uk 2726
Überdachungen
OPTIONS AND ACCESSORIES
Of course, we also take care of everything else that you
need. Doors, windows and lighting systems are installed ba-
sed on your individual requirements. Regardless of whether
you need a roller shutter door, sliding door, sectional door or
a high-speed door, we can provide it. If you need anything
else our development experts can take care of it.
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
For further product information go to: https://www.hts-ind.co.uk 2928
SECTIONAL DOORS
nManufactured from PU sandwich panels
nElectric or manual drive
nOptional vision panels
nAvailable in a range of standard colours
STEEL DOORS
nStandard measurements: 1.00 x 2.00m
or 2.00 x 2.00m
nAvailable as a personnel door or
emergency door
nAvailable in a range of standard colours
ROLLER SHUTTER DOORS
nManufactured from galvanized
steel profiles
nElectric drive
WINDOWS
nAluminium or U-PVC frames
nDouble glazing
nAvailable in different sizes
nAvailable in a range of standard colours
SLIDING DOORS
nManufactured from steel sheets or
PU sandwich panels
nSingle or double wing
nAvailable in a range of standard colours
SKYLIGHTS, ROOFLIGHTS
nPVC glazing
nAvailable in different sizes
nSmoke extraction flaps
nWind and rain alarm systems – optional
HIGH SPEED DOORS
nDifferent door options
nDifferent control options
nOptional clear sections
nAvailable in a range of standard colours
WALL AND LIGHT PANELS
nCost effective alternatives to
conventional glass facades
nAvailable for roof and walls
nVarious versions available
DOORS AND WINDOWS
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
For further product information go to: https://www.hts-ind.co.uk 3130
For further product information go to: https://www.hts-ind.co.uk
FURTHER OPTIONS
nRental options - subject to geogra-
phical location
nTransport, assembly, dismantle,
removal, relocation
nStructural calculations
nPlanning permission - subject to
geographical location
nConcealed screws
nOptional sandwich panel finishes
LIGHTING
nWaterproof lighting
nVariable lighting levels
nLED options
FLOOR END PLATES
nFloor end plates for various
ground conditions
GLASS FACADES
nAluminium or U-PVC frames
nDouble glazing
nAvailable in a range of standard colours
FIXING
nFloor end plates for various
ground conditions
RAIN GUTTERS
nZinc rain gutters
nRain gutter diameter 180mm
nDown pipe diameter 120mm
CRASH BARRIERS
nCrash barriers manufactured from a
galvanized steel profile
nHeight individually adjustable
nFixing using pegs or ground anchors
STANDARD COLOURS
ACCESSORIES
RAL 9002 RAL 9006 RAL 9007 RAL 5010 RAL 6005 RAL 7016 RAL 7035 RAL 7037 RAL 8012
CANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIESCANOPIES | NON-INSULATED TEMPORARY BUILDINGS | INSULATED TEMPORARY BUILDINGS | ACCESSORIES
3332
QUALITY ASSURANCE
We aim to provide our customers with complete confidence
in our products. Our range of semi-permanent buildings
and accessories are manufactured to stringent DIN EN ISO
9001:2008 & CE-certified quality standards, backed by a
first-rate level of service, providing customers with total
peace of mind on products, workmanship and ongoing
after-sales support.
FURTHER APPLICATION EXAMPLES FROM OUR PORTFOLIO
Zer
tif
izierter Hersteller
für B
auprodukte nach EN 109
0-1
•
•
For further product information go to: https://www.hts-ind.co.uk 3534
SALES OFFICES & TECHNICAL SUPPORT INAustralia, Austria, Brazil, Chile, Czech Republic, France, Germany, Great Britain, India, Ireland, Italy, Jordan, Kazakhstan, Mexico, Middle East, Morocco, Netherlands, Pakistan, Poland, Portugal, Romania, Russia, Scandinavia, Singapore, Slovenia, South Africa, South East Europe, Spain, Switzerland, Turkey, Ukraine, United Arab Emirates, USA, Vietnam.
CONTACT
INDUSTRIAL & COMMERCIAL BUILDINGS
STORAGE | PRODUCTION | LEISURE | LOGISTICS |
WORKSHOPS | RETAIL | SPORTS & MUCH MORE
Contact information for all the above countries may be
found on our website.
www.hts-tentiq.com/contact
Phone: +44 (0) 1276 462 600 | Fax: +44 (0) 1276 462 601 | Email: [email protected]: +49 (0) 6049 9510-0 | Fax: +49 (0) 6049 9510-20 | Email: [email protected] | Web: www.hts-tentiq.com Hinter der Schlagmühle 1 | 63699 Kefenrod | GermanyHTS tentiQ GmbHHEAD OFFICE & PRODUCTION