Residential house plan rules and regulation Description Depth/Area Codes Dwelling location and lot occupancy The dwelling shall occupy not more than 90% of a corner lot and 80% of an inside lot, and subject to the provisions on easements of light and view of the civil code of the Philippines, shall be at least 2 meters from the property line. Light and Ventilation Every dwelling shall be so constructed and arranged as to provide adequate light and ventilation as provided under Section 805 to Section 811 of the Code Sanitation Every dwelling shall be provided with at least one sanitary toilet and adequate washing and drainage facilities. Foundation Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least 250

Upload: mitualves

Post on 15-Nov-2015

217 views

Category:

Documents


1 download

DESCRIPTION

Design codes

TRANSCRIPT

Residential house plan rules and regulation

Residential house plan rules and regulation

DescriptionDepth/AreaCodes

Dwelling location and lot occupancyThe dwelling shall occupy not more than 90% of a corner lot and 80% of an inside lot, and subject to the provisions on easements of light and view of the civil code of the Philippines, shall be at least 2 meters from the property line.

Light and VentilationEvery dwelling shall be so constructed and arranged as to provide adequate light andventilation as provided under Section 805 to Section 811 of the Code

SanitationEvery dwelling shall be provided with at least one sanitary toilet and adequate washingand drainage facilities.

FoundationFootings shall be of sufficient size and strength to support the load of the dwelling andshall be at least 250 millimeters thick and 600 millimeters below the surface of theground.

PostThe dimensions of wooden posts shall be those found in Table VII.5.: Dimensions ofWooden Posts. Each post shall be anchored to such footing by straps and bolts ofadequate size. Logs or tree trunk suportales may be used as post in indigenous traditional type ofconstruction, provided that these are of such sizes and spacing as to sustain verticalloading equivalent at least to the loading capacities of the posts and spacing in this Table.

FloorThe live load of the first floor shall be at least 200 kilograms per sq. meter and for thesecond floor, at least 150 kilograms per sq. meter.

Roof The wind load for roofs shall be at least 120 kilograms per sq. meter for verticalprojection.

StairsStairs shall be at least 750 millimeters in clear width, with a rise of 200 millimeters and aminimum run of 200 millimeters.

Entrance and ExitThere shall be at least one entrance and another one for exit.

Electrical RequirementsAll electrical installations shall conform to the requirements of the Philippine ElectricalCode.

Mechanical RequirementsMechanical systems and/or equipment installations shall be subject to the requirements ofthe Philippine Mechanical Engineering Code.

Determining Building Bulk Refer to Table VII.G.1. Reference Table of Floor to Lot Area Ratio (FLAR) Designations/Rights.

Allowable Maximum Building Footprint (AMBF)Refer to rule and computation on page 106 108.

General Classification of Use/Character of Occupancy of Building/StructureGroup A residential (Dwellings) Division A-1(Residential building/ structure for exclusive use of single family occupants)Refer to rule on Table VII.1. Schedule of Principal, Accessory and Conditional Use/Occupancy of Building/Structure