NOTE:CONTRACTOR SHALL REMOVE PAVEMENT, CONCRETE WALKS,CURB AND GUTTER, FENCES, AND SIGNS AS NECESSARY TOINSTALL UTILITY UPGRADES. HOWEVER CONTRACTOR MUSTMAKE ALL EFFORTS TO SAVE TREES AND PROTECT UTILITIES.CONTRACTOR SHALL RECORD LOCATION OF ALL EX. PAINTMARKINGS, PAVEMENT LOCATIONS AND CONC. WALKLOCATIONS AND SHALL REPLACE TO MATCH EXISTING AND PERDETAILS AND DEKALB COUNTY STANDARDS. ALL DISTURBEDAREAS THAT ARE NOT IMPERVIOUS MUST BE PERMANENTLYSTABILIZED WITH BERMUDA SOD.
NOTE:RETAINING WALL SPOT ELEVATIONS ARE BASED ON AGYMNASIUM FFE OF 869.00 (TBM).
SITE LAYOUT &UTILITY PLAN
C100
Know what's below.before you dig.CallDial 811
Or Call 800-282-7411
CAUTION
B R E E D L O V ELAND PLANNINGLandscape Architects • Civil Engineersw w w . l a n d p l a n n i n g . n e t
PROPOSED GREASE TRAP INV. IN: 0.5' HIGHER THAN INV. OUT INV. OUT: TBD
AutoCAD SHX Text
CLEANOUT (TYP.)
AutoCAD SHX Text
REPLACE EX. BACKFLOW PREVENTER W/ RPZ PER DEKALB COUNTY STANDARDS (RPZ SIZE SHALL MATCH SIZE OF EX. WATER LINE)
AutoCAD SHX Text
DO NOT DUPLICATE DRAWINGS WITHOUT WRITTEN PERMISSION
AutoCAD SHX Text
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE DESIGN PROFESSIONAL ASSUMES NO RESPONSIBILITY FOR THE LOCATIONS SHOWN AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATIONS OF UTILITIES WITHIN THE LIMITS OF THE WORK. DAMAGE TO EXISTING UTILITIES BY THE CONTRACTOR, FROM HIS/ HER OPERATIONS, SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
AutoCAD SHX Text
CONTRACTOR SHALL BE RESPONSIBLE TO SECURE THE SERVICES OF A PRIVATE UTILITY LOCATOR FIRM DURING THE ENTIRE COURSE OF CONSTRUCTION. CONTRACTOR SHALL PAY FOR SAID SERVICES. CONTRACTOR SHALL IMMEDIATELY REPAIR ALL UTILITIES DAMAGED BY CONSTRUCTION ACTIVITIES, AT NO ADDITIONAL COST TO THE OWNER.
AutoCAD SHX Text
CONTRACTOR SHALL BE RESPONSIBLE FOR COMPACTION OF BACKFILL OF ALL UTILITY TRENCHES WITHIN SITE WORK LIMITS. THIS INCLUDES TRENCHES DUG AND BACKFILLED BY LOCAL UTILITIES, SUCH AS POWER, GAS, TELEPHONE, ETC. CONTRACTOR SHALL PROVIDE ADDITIONAL BACKFILL AND COMPACTION AS NECESSARY, IF SETTLEMENT OCCURS.
AutoCAD SHX Text
R
AutoCAD SHX Text
SCALE: 1"=40'-0"
AutoCAD SHX Text
20
AutoCAD SHX Text
10
AutoCAD SHX Text
0
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
80
AutoCAD SHX Text
120
AutoCAD SHX Text
CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID TO EXAMINE AND BECOME FAMILIARIZED WITH THE EXISTING CONDITIONS WITHIN THE LIMITS OF CONSTRUCTION SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL REPLACE OR RESTORE EXISTING ITEMS DAMAGED DURING CONSTRUCTION. REPLACEMENT ITEM OR RESTORED ITEM SHALL MATCH EXISTING AND MEET OR EXCEED CONDITION PRIOR TO CONSTRUCTION.
AutoCAD SHX Text
DISTURBED AREAS SHALL BE PERMANENTLY STABILIZED WITH BERMUDA SOD NON-EXEMPT ACTIVITIES SHALL NOT BE CONDUCTED WITHIN THE 25 OR 50-FOOT UNDISTURBED STREAM BUFFERS AS MEASURED FORM THE POINT OF WRESTED VEGETATION WITHOUT FIRS ACQUIRING THE NECESSARY VARIANCES AND PERMITS ANY AMENDMENTS/REVISIONS TO THE ES&PC PLAN HAVING A SIGNIFICANT EFFECT ON BMPS WITH A HYDRAULIC COMPONENT MUST BE CERTIFIED BY THE DESIGN PROFESSIONAL. WASTE MATERIALS SHALL NOT BE DISCHARGED TO WATERS OF THE STATE, EXCEPT AS AUTHORIZED BY A SECTION 404 PERMIT THE ESCAPE OF SEDIMENT FROM THE SITE SHALL BE PREVENTED BY THE INSTALLATION OF EROSION AND SEDIMENT CONTROL MEASURES AND PRACTICES PRIOR TO, OR CONCURRENT WITH , LAND DISTURBING ACTIVITIES. EROSION CONTROL MEASURES WILL BE MAINTAINED AT ALL TIMES. IF FULL IMPLEMENTATION OF THE APPROVED PLAN DOES NOT PROVIDE FOR EFFECTIVE EROSION CONTROL, ADDITIONAL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE IMPLEMENTED TO CONTROL OR TREAT THE SEDIMENT SOURCE. ANY DISTURBED AREA LEFT EXPOSED FOR A PERIOD GREATER THAN 14 DAYS SHALL BE STABILIZED WITH MULCH OR TEMPORARY SEEDING.
AutoCAD SHX Text
EROSION CONTROL NOTES
AutoCAD SHX Text
CONTRACTOR SHALL VERIFY EXISTING SANITARY/STORM SEWER INVERT ELEVATIONS AND CONFIRM PROPOSED INVERT ELEVATIONS WITH DESIGN ENGINEER PRIOR TO CONSTRUCTION.
AutoCAD SHX Text
1. ALL REQUIRED BACKFLOW DEVICES MUST BE INSTALLED PER DEKALB COUNTY DEPARTMENT OF WATERSHED MANAGEMENT STANDARDS AS CLOSE AS PRACTICAL TO PROPERTY LINE AND OUT OF RIGHT-OF-WAY 2. INSTALLATION OF BACKFLOW DEVICES INSIDE THE BUILDING IS NOT ALLOWED WITHOUT PRIOR APPROVAL FROM BACKFLOW SECTION OF DEKALB COUNTY DEPARTMENT OF WATERSHED MANAGEMENT. 3. CALL (404) 687-4075 FOR BACKFLOW INSPECTION PRIOR TO INSTALLING ANY BACKFLOW DEVICE
AutoCAD SHX Text
1. ALL DESIGN AND CONSTRUCTION FOR WATER, SEWER, FIRE LINES, LIFT STATIONS, & BACKFLOW PREVENTION SHALL COMPLY WITH DEKALB COUNTY DEPARTMENT OF WATERSHED MANAGEMENT DESIGN STANDARDS 2009 EDITION, VERSION 1.0. ACTUAL FIELD CONDITIONS MAY DICTATE MORE STRINGENT REQUIREMENTS IF DEEMED NECESSARY BY THE CONSTRUCTION INSPECTOR. 2. DEVELOPER SHALL PROVIDE RECORD DRAWINGS "AS-BUILT PLANS" AND "FINAL PLATS" (IF APPLICABLE) IN HARD COPY AND ELECTRONIC FORMAT, AS WELL AS, RECORD ALL EASEMENTS THAT WILL BE DEDICATED TO DEKALB COUNTY IN THE COURT HOUSE, PRIOR TO APPROVAL OF AS-BUILT PLANS. 3. F.0.G. COMPLIANCE (GREASE TRAP) REVIEW AND APPROVAL REQUIRED. CALL (404) 687-7157. 4. FIELD CHANGES DURING CONSTRUCTION MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY THE COUNTY WATER AND SEWER ENGINEER BEFORE CHANGES ARE IMPLEMENTED. 5. FOR PROJECTS WITHIN CITIES, CONTRACTOR SHALL PROVIDE A MAINTENANCE BOND TO DEKALB COUNTY FOR WATERSHED UTILITIES PRIOR TO APPROVAL OF AS-BUILT PLANS. 6. CONTRACTOR MUST JET CLEAN AND T.V. SANITARY SEWER LINES AFTER CONNECTIONS ARE MADE TO THE EXISTING SEWER TIE-IN POINTS. TRACER WIRE TO BE INSTALLED FOR PVC PIPES. 7. CONTRACTOR MUST NOTIFY THE WATER & SEWER CONSTRUCTION INSPECTOR FOR AT LEAST 72 HOURS PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES. CONTACT M. MCGUIRE (DISTRICT 18) (PHONE) 404-687-4060. 8. THRUST BLOCKS ARE REQUIRED WHEREVER PIPE CHANGES DIRECTION (TEES, BENDS, ETC.) 9. GRAVITY SEWER LINE MATERIAL SHALL BE PVC (SDR35) OR DIP (CLASS 350) 10. PROVIDE EASEMENT PLAT & DEED FOR REVIEW FOR ALL SANITARY SEWER AND WATER EASEMENTS (AFTER CONSTRUCTION AND WITH AS-BUILTS. 11. WATER AND SEWER ACCESS FEES NEED TO BE PAID UNDER THE FOLLOWING CIRCUMSTANCES: NEW CONSTRUCTION, RE-DEVELOPMENT, ADDITIONS, CHANGE OF USE, ETC. THESE FEES ARE TO BE PAID AT 330 W. PONCE DE LEON AVE, 2ND FLOOR. FAILURE T SETTLE THESE FEES WILL RESULT IN DELAYS FOR OBTAINING WATER & SEWER PLAN APPROVAL, AS WELL AS CERTIFICATE OF OCCUPANCY/COMPLETION. CALL (404) 371-4918 FOR FEE CALCULATIONS OR ANY QUESTIONS. 12. FIRE LINES, F.O.G., BACKFLOW PREVENTION, AND LIFT STATIONS REQUIRE SEPARATE REVIEW. 13. TO PURCHASE A COPY OF THE DESIGN STANDARDS, PLEASE CALL (770) 414-2383 OR (770) 621-7272.
AutoCAD SHX Text
NO IRRIGATION LINE PRESENT ON SITE.
AutoCAD SHX Text
ALL ON-SITE WATER & SANITARY SEWER IS PRIVATE.
AutoCAD SHX Text
CONTRACTOR SHALL STABILIZE ALL DISTURBED AREAS AS REQUIRED BY CONTRACT DOCUMENTS AND LOCAL GOVERNING REGULATIONS
AutoCAD SHX Text
Ds1
AutoCAD SHX Text
Ds2
AutoCAD SHX Text
Ds4
AutoCAD SHX Text
Du
AutoCAD SHX Text
Pm
AutoCAD SHX Text
SCHEMATIC
AutoCAD SHX Text
2/16/16
AutoCAD SHX Text
50%%% CD DRAWINGS
AutoCAD SHX Text
8/8/16
AutoCAD SHX Text
100%%% CD DRAWINGS
AutoCAD SHX Text
10/15/16
AutoCAD SHX Text
BID DOCUMENTS
AutoCAD SHX Text
12/21/16
AutoCAD SHX Text
REVISION 1
AutoCAD SHX Text
2/14/17
AutoCAD SHX Text
1
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
I
AutoCAD SHX Text
H
AutoCAD SHX Text
C
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
P
AutoCAD SHX Text
A
AutoCAD SHX Text
R
AutoCAD SHX Text
K
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
G
AutoCAD SHX Text
A
AutoCAD SHX Text
L
AutoCAD SHX Text
E
AutoCAD SHX Text
P
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
S
AutoCAD SHX Text
G
AutoCAD SHX Text
I
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
S
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text
R
AutoCAD SHX Text
No. 1083
AutoCAD SHX Text
R.
AutoCAD SHX Text
R
AutoCAD SHX Text
12-21-2016
AutoCAD SHX Text
CAFETERIA SEATING CAPACITY - 529 KITCHEN HOURS OF OPERATION: 7:00 AM - 7:30 AM 10:05 AM - 12:25 PM