Surge Protection:Safety for Sewage Plants.
DEHN – Competence in Lightning and Surge Protection.
Surges disturb processes.Sewage plants play a key role in the useof the resource water. With a chain ofmutually dependent processes, theymanage to filter the toxic substancesbound in the dirty wastewater andregain drinking water.
Various measuring and analysis methodswith extensive system technology are usedfor process control.Damage to this equipment can disturbthe process sustainably and even lead toa threat to the environment. Therefore,its availability deserves high priority.
Power supply, for example, as wellas measuring and control systems of sewageplants are threatened by damage due tosurges or direct lightning strokes. Surgesare caused by distant or close lightningstrokes, but also by switching operations(e.g. when switching heavy loads).
230 V ~rain overflow basinpump / lift
sation
rake
ventilation / grid chamber
primarysedimentationbasin
precipitationtank
aeration tanknitrification / denitrification
sedi-mentation
tank
outlet
sewage plant controlblack water basin
Profibus PA
telecontrol signal
4-20 mA
4-20 mA
Profibus DP
4-20 mA Ex (i)
230 V ~
230 V ~
230 V ~
Example 1
Example 2
Example 3
Example 4
Example 6Example 5
DEHN – Lightning and Surge Protection for Sewage Plants from one Source.
Illustration of a sewage plant.Sewage plants are especially exposed to therisks of atmospheric discharges due to theirlarge sizes. Furthermore, interference pulsescan spread well due to the widely networkedparts of the plant.
A lightning protection system consists ofexternal lightning protection, internal light-ning protection and lightning equipotentialbonding. External lightning protectionprotects buildings from fire or mechanicaldamage by lightning. Internal lightningprotection is supposed to prevent hazardoussparking within the building.
Lightning equipotential bonding reduces thepotential differences caused by lightningcurrents. As a part of the lightning currentflows, for example, also via the externalelectrical supply lines of the sewage plant andcan thus damage them, the lines have to beprotected by SPDs with lightning currentcarrying capability.Surge arresters reliably protect terminaldevices from conducted surges.The lightning protection zones concept isa comprehensive catalogue of protectionmeasures. And it helps to optimise theavailability of the installation.
Example: Intermeshed earth-termination system.A lightning equipotential bonding system should be established foreach part or building of the plant. Intermeshing these installationsreduces conducted partial lightning currents among the parts of theplant. Powerful surge arresters minimise the risk due to surges.
The following standards apply to the earth-termination system:IEC 62305-4: “Electrical and electronic systems within structures”prEN 50114: “Materials and size requirements for earth electrodes from the corrosion point of view”
Know-how – Designing aids for lightningand surge protection.The designer of the installation sets thebasis for the later availability of the sewageplant. He takes effective protectionmeasures against harmful surges. For thispurpose, he applies important regulationswhich help to implement a complete pro-tection concept. At the design stage,both the external lightning protectionsystem, earthing system with equipotentialbonding and effective protection in caseof surges are taken into consideration.
Building codes
IEC 60364-...Erection of power installations
with nominal voltagesup to 1000 V
IEC 61643-... / IEC 61663-...Lightning and surge protection
for telecommunication andsignalling lines
IEC 62305Protection against lightning
Part 3: Physical damage tostructures and life hazard
Part 4: Electrical and electronicsystems within structures
IEC 62305Protection against lightning
Part 2: Risk management
Application guidesCodes of practice
Lightning and surge protectionconcept for a sewage plant
Concepts for Measuring Points.
LPZ = Lightning Protection Zone
rain overflow basin
ultrasonicmeasuringequipment
telecontrol signal
level + volume
LPZ 0A
LPZ 100.0
pH value +temperature
2 x 4 - 20 mA
sewage plantcontrol
inlet of the primarysedimentation basin
electrode at the hose fitting
LPZ 1000.0
LPZ 0B
tubing
volume
Profibus DP
sewage plantcontrol
recirculation line
magneticallyinductive sensor
230 V ~ (TN-System)
230 V ~ (TN system)
230 V ~ (TN system)
Example 1: Telecontrol signal and power supplyLightning and surge protection for the flow and levelmeasuring equipment at the distant rain overflow basin
Shield earthing at both ends of the short wires from the measuring transformer to the ultrasonic sensorsMeasured data are transmitted to thesewage plant control via telecontrol signalThe power supply is provided directly by the utilityThe power supply and telecontrol systems are protected by combined lightning current and surge arresters capable of carrying lightning currents withan appropriate voltage protection level for terminal equipment and minimum requirements space
Example 2: 4-20 mA and power supply (non-Ex) and 4-20 mA Ex (i)
Surge protection for the sewer network levelmeasuring equipment
Ex zone: Shield earthing at both ends of the short wiresfrom the measuring transformer to the ultrasonic sensorsIf the measuring transformer and Ex isolationamplifier are spatially separated, Ex (i)-type surge arresters are installed at both ends of theconnecting cableOutside of the Ex zone, surge arresters are in-stalled for protecting the 4-20 mA signal andpower supply system
Example 3: 2 x 4-20 mA and power supplySurge protection for the pH value and temperaturemeasuring equipment
Shield earthing at both ends of the lines from the measuring transformer to the electrode of the hose fittingThe pH value and temperature are transmittedto the sewage plant control as two independent4-20 mA signalsPower supply is provided by the sewageplant controlThe lines going to the sewage plant control are protected by surge arresters
volume
power supply4 - 20 mA
sewage plantcontrol
4 - 20 mAEx (i)
ultrasonic measuringequipment
LPZ 100.0
00.0
LPZ 0B
Example 4: PROFIBUS DP and power supply systemSurge protection for the flow measuring equipment
Magnetically inductive measuring sensor withPROFIBUS DP and power supply connectionThe SPDs are installed close to a distribution boardThe shield of the bus cable has to be led con-tinuously and earthed with low impedance both viathe sensor and SPDThe bus cable and power supply system areprotected by surge arresters
Example 1:1 x BLITZDUCTOR® XT ML2 BD 180 *Part No. 920 247
or1 x BLITZDUCTOR® XTU ML2 BD S 0-180 *Part No. 920 249
1 x DEHNventil® M TT 2P 255 FM Part No. 951 115Modular combined lightning current and surge arrester withremote signalling contact for TT systems
or1 x DEHNventil® M TN 2P 255 FM Part No. 951 205
Modular combined lightning current and surge arrester withremote signalling contact for TN systems
1 x SLK 16 Part No. 910 099Accessories, PE terminal
Example 2:1 x BLITZDUCTOR® XT ML2 BD S 24 *Part No. 920 244
or1 x BLITZDUCTOR® XTU ML2 BD S 0-180 *Part No. 920 249
1 x BLITZDUCTOR® XT ML4 BD EX 24 **Part No. 920 381KEMA 06 ATEX 0274 X II 2 (1) G Ex ia IIC T4/T5/T6, FISCO
1 x DEHNpipe MD EX 24 M 2 Part No. 929 960Surge arrester, Y/L SPD Class TYPE 2 P1
KEMA 09 ATEX 0122 X II 2 (1) G Ex ia IIC T4/T5/T6, FISCO1 x KV S M20 MS 9.5 Part No. 929 982
Accessories, EMC cable gland, IP 68, Ø 6.5-9.5 mm2 x SLK 16 Part No. 910 099
Accessories, PE terminal1 x DEHNguard® M TN 275 FM Part No. 952 205
Surge arrester Type 2 with remote signalling contact, pluggableExample 3:1 x BLITZDUCTOR® XT ML4 BD 24 *Part No. 920 344
or1 x BLITZDUCTOR® XTU ML4 BD 0-180 *Part No. 920 349
1 x SLK 16 Part No. 910 099Accessories, PE terminal
1 x DEHNguard® M TN 275 FM Part No. 952 205Surge arrester Type 2 with remote signalling contact, pluggable
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P2
Example 4:1 x BLITZDUCTOR® XT ML2 BD HFS 5 *Part No. 920 271
Combined lightning current and surge arrester, 12 Mbit/s
or1 x BLITZDUCTOR® XTU ML2 BD S 0-180 *Part No. 920 249
1 x SAK BXT LR Part No. 920 395Accessories, EMC spring terminal for shield connection
1 x SLK 16 Part No. 910 099Accessories, PE terminal
2 x DEHNguard® M TN 275 FM Part No. 952 205Surge arrester Type 2 with remote signalling contact, pluggable
2-part unit, Y/L SPD Class TYPE 1 P1
Universal combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
* in combination with Part No. 920 300 ** in combination with Part No. 920 301
LPZ 100.0
00.0
shielded sensor lines
LN
4 - 20 mA Ex (i)
4 - 20 mA
230 V ~ (TN system)
LPZ 1
00.0
LN
telecontrol signal
shieldedsensorlines
230 V ~ (TN system)
LN
2 x 4 - 20 mA
shieldedsensor
lines
230 V ~ (TN system)
LPZ 1000.0
LN
Profibus DP
230 V ~ (TN system)
2
2
2
2
2
22
2
2
Concepts for Measuring Points.
DP PA Ex 4-20 mA
LPZ = Lightning Protection Zone
BLITZDUCTOR® XT, combined lightning current and surgearrester modules with LifeCheck®
Condition Monitoring System with BLITZDUCTOR® XT
Example 5: PROFIBUS PA Ex (i)Surge protection for the level measuring equipment
The level measuring sensor used in hazardous zonesis connected to the sewage plant control via anintrinsically safe PROFIBUS PA unitAs there is no external power supply,only the bus connector has to be protectedEx (i)-type SPDs have to be installed into metalenclosures upstream of the measuring sensorShielding within the hazardous zone has to be performed in accordance with IEC 60079-14
Example 6: Switchgear cabinets with programmablelogic control (PLC)
Surge protection for the sewage plant controlLines between parts of the plant have to be pro-tected with the same types of SPDs as the connectedmeasuring pointsAt the entry of the switchgear cabinet, the cableshields have to be earthed with low impedanceand lines have to be protected by SPDsThe SPDs have to be arranged clearly to avoidinstallation errorsIf lightning current arresters for the supply systemsare installed centrally, e.g. into the low-voltage maindistribution board, the switchgear cabinets haveonly to be protected by surge arrestersLines within the building of the sewage plant control also have to be integrated into the protection concept
Easy SPD testing due to LifeCheck®
BLITZDUCTOR XT with integrated LifeCheck makesmaintenance very easy. LifeCheck uses modern RFIDtechnology for monitoring protective circuits and forcommunication. Independent from downtimes of thesystem, LifeCheck allows for quick and easy testing ofSPDs by means of a portable testing device of typeDRC LC M3+.
LifeCheck® Condition Monitoring
The LifeCheck technology also allows for the permanentmonitoring of the surge arresters. This technology allowsto continuously monitor up to 300 pairs in a system ofup to 15 MCM monitoring devices. Faults will be signalledeither by remote signalling contact to a superior systemcontrol or they can be registered by a PC software whichcan be provided free of charge. Considering the hazardof lightnings and surges, you will be sure to have utmostprotection and availability with this technology.
black water basin
ultrasonic measuringequipment
level
Profibus PA
sewage plantcontrol
LPZ 0B
LPZ 1
230 V ≈
switchgear cabinet
TYPE 2 P1
Example 5:1 x DEHNpipe MD EX 24 M 2 Part No. 929 960
Surge arrester, Y/L SPD Class TYPE 2 P1
KEMA 09 ATEX 0122 X II 2 (1) G Ex ia IIC T4/T5/T61 x KV S M20 MS 9.5 Part No. 929 982
Accessories, EMC cable gland, IP 68, Ø 6.5-9.5 mm
Portable handheld device with LifeCheck sensor for flexibleuse. Visual and acoustic “OK” indication of identifiedLifeCheck circuits.
Quick and easy testing of the SPDs within seconds During operation
Electrically isolated, no removing of the moduleDetection of potential thermal and electrical overload of all componentsBattery-operated, no external power supply necessaryUSB terminal for transmission of the test results onthe PCIncluded PC software for documentation andadministration of the test results
Part No. 910 653
Stationary DIN-rail-mounted SPD monitoring device to ensurepermanent protection and availability of the systems. Suitablefor permanent condition monitoring of up to 10 BXT lightningcurrent arresters with LifeCheck function.
Permanent SPD monitoring for maximum protection and availability of systemsDetection of potential thermal and electrical overloadof all componentsRemote signalling contactsRS 485 interfacePC software for monitoring available free of charge
Part No. 910 695
DRC MCM XT for Condition Monitoring
DRC LC M3+ SPD Test Device
Example 6:1 x BLITZDUCTOR® XT ML2 BD HFS 5 *Part No. 920 271
Combined lightning current and surge arrester, 12 Mbit/s
or1 x BLITZDUCTOR® XTU ML2 BD S 0-180 *Part No. 920 249
1 x SAK BXT LR Part No. 920 395Accessories, EMC spring terminal for shield connection
1 x BLITZDUCTOR® ML2 BD HF EX 6 **Part No. 920 538Surge arrester with LifeCheckKEMA 06 ATEX 0274 X II 2 (1) G Ex ia IIC T4/T5/T6
1 x BLITZDUCTOR® XT ML4 BD EX 24 **Part No. 920 381KEMA 06 ATEX 0274 X II 2 (1) G Ex ia IIC T4/T5/T6, FISCO TYPE 2 P1
3 x BLITZDUCTOR® XT ML4 BD 24 *Part No. 920 344
1 x SLK 16 Part No. 910 099Accessories, PE Terminal
1 x DEHNguard® M TN 275 FM Part No. 952 205Surge arrester Type 2 with remote signalling contact, pluggable
2-part unit, Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
Combined lightning current and surge arrester, 2-part unit,Y/L SPD Class TYPE 1 P1
* in combination with Part No. 920 300 ** in combination with Part No. 920 301
Profibus-PA
LN
Profibus DP PA Ex 4-20 mA
230 V (TN system)
Samaratel. +7 846 273 95 [email protected]
Yekaterinburgtel. +7 343 287 19 [email protected]
St. Petersburgtel. +7 812 327 [email protected]
Moscowtel. +7 495 641 [email protected]
Helsinkitel. +358 9 540 [email protected]
Vilniustel. +370 5 215 [email protected]
Rigatel. +371 6738 [email protected]
Мinsktel. +375 17 200 [email protected]
Tallinntel. +372 668 [email protected]
Кievtel. +38 044 495 33 [email protected]
Dehn_Safety_for_Sewage_Plants_en_0515.pdf