defender datacom cabinets - crenlo · 9 defender ™ datacom cabinets defender™ datacom cabinets...

2
9 DEFENDER Datacom Cabinets Defender™ Datacom Cabinets | 507-287-3535 | www.emcorenclosures.com | CRN.2185.09.16 12,000 BTU Full Rack DEFENDER™ server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don’t have cooling infrastructure already in place. Capable of providing up to 4 kW of cooling, these cabinets with NEMA rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 40U rack space with square hole rails 42” depth standard 30” and 36” depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with 12,000 BTU AC units Cooling capacity approximately 4.0 kW AC Features Designed to mount on the side of the enclosure while maintaining NEMA 12, 3R, 4, or 4X integrity. 120V / 12,000 BTU Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Part Number: DC-40U2442-AC12000-D Cabinet | 40U Rack Space | 24” Wide | 42” Deep AC Unit | 12,000 BTU Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an AC unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. + Complete Defender Line Half Rack 3,000 BTU ~1.0 kW cooling Half Rack 6,000 BTU ~2.0 kW cooling Half Rack 8,000 BTU ~2.6 kW cooling Full Rack 12,000 BTU ~4.0 kw cooling Full Rack 8,000 BTU ~2.6 kW cooling

Upload: lamdung

Post on 16-Dec-2018

245 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DEFENDER Datacom Cabinets - Crenlo · 9 DEFENDER ™ Datacom Cabinets Defender™ Datacom Cabinets | 507-287-3535 | | CRN.2185.09.16 12,000 BTU Full Rack DEFENDER™ server cabinets

9

D E F E N D E R ™ Datacom Cabinets

Defender™ Datacom Cabinets | 507-287-3535 | www.emcorenclosures.com | CRN.2185.09.16

12,000 BTU Full RackDEFENDER™ server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don’t have cooling infrastructure already in place. Capable of providing up to 4 kW of cooling, these cabinets with NEMA rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system.

Cabinet Features• Welded 12-gauge steel frame with 2000 static load capacity• 40U rack space with square hole rails• 42” depth standard 30” and 36” depths available• Fully gasketed locking front and rear doors• Gland plate in top for cable entry/exit • Remote monitoring capability• Compatible with 12,000 BTU AC units • Cooling capacity approximately 4.0 kW

AC Features• Designed to mount on the side of the enclosure while maintaining

NEMA 12, 3R, 4, or 4X integrity.• 120V / 12,000 BTU• Digital temperature controller with alarm• Built-in condensate evaporator• Efficient,quiet,longlastingrotarycompressor• Environment friendly HFC refrigerant• Easypull-outfilter• UL Listed

Part Number: DC-40U2442-AC12000-D

Cabinet | 40U Rack Space | 24” Wide | 42” Deep AC Unit | 12,000 BTU

Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an AC unit. Forretrofitjobs;theconditionoftheexistingequipment,thetypeofrackitiscurrentlyhoused in, and most importatnly the length of service loop, if any, of the existing cable.

+

Complete Defender Line

Half Rack3,000 BTU

~1.0 kW cooling

Half Rack6,000 BTU

~2.0 kW cooling

Half Rack8,000 BTU

~2.6 kW cooling

Full Rack12,000 BTU

~4.0 kw cooling

Full Rack8,000 BTU

~2.6 kW cooling

Page 2: DEFENDER Datacom Cabinets - Crenlo · 9 DEFENDER ™ Datacom Cabinets Defender™ Datacom Cabinets | 507-287-3535 | | CRN.2185.09.16 12,000 BTU Full Rack DEFENDER™ server cabinets

10

D E F E N D E R ™ Datacom Cabinets

Defender™ Datacom Cabinets | 507-287-3535 | www.emcorenclosures.com | CRN.2185.09.16

448[17.65]

1323[52.09]

600[24.00]

1120[44.13]

1955[77.00]

872[34.34]

76[3.00]

390 x 495 max[15.25 x 19.50]

Mounting Dimension

450[17.72]

465[18.30]

95 x 95 [3.75 x 3.75]

Back Left SideRight SideFrontFront (w/o door)

Top Bottom Top (w/ gland plate open) Section A-A

A A

40U

Technical Specifications

For enclosure or panel cooling, Our exclusive use of a rotarycompressor allows us to manufacture the smallest, lightestweight, most energy efficient cooling solutions in the industry.

Technical Data

Vertical Mount10,000, 12,000 BTUH - 120/230/480 VACAir Conditioners

Standard FeaturesOptionsTechnical DataAir Flow

Ice Qube, Inc., 141 Wilson Ave., Greensburg, PA 15601 Call: 724.837.7600 Fax: 724.837.3386www.iceqube.com Email: [email protected]

Cooling Solutions

Standard Features

• Digital temperature controller with alarm.• Built-in condensate evaporator.• Durable 16 gauge welded steel construction.• Efficient, quiet, long lasting rotary compressor.• Environment friendly HFC refrigerant.• Easy pull-out filter.• UL Listed.• Space saving aesthetic cabinet design.• Designed to mount on side of enclosure while maintaining NEMA type 12, 3R, 4, or 4X integrity.

Options & Accessories

• Stainless Steel • External Heat Output • Low Ambient• Remote Controller Kit • Internal Heat• Replacement Filters • Alarm Output• Corrosive Packages • Crankcase Heater

Model BTU/Watts Volts Max Amps Max Temp ºF/ºC Weight (lbs/Kg) Dimensions (In/mm)

IQ10000V 10000/2931 120/60 15.1 131/55c 135 / 61.2 H 52.09” (1323mm) x W 17.65” (448mm) x D 10.34” (263mm)

IQ10000V 10000/2931 230/60/50 7.9/8.7 140/60c 135 / 61.2 H 52.09” (1323mm) x W 17.65” (448mm) x D 10.34” (263mm)

IQ10000V** 10000/2931 480/60/50 4.0/4.4 140/60c 173 / 78.5 H 57.65” (1464mm) x W 17.65” (448mm) x D 10.34” (263mm)

IQ12000V 12000/3517 120/60 19.6 131/55c 135 / 61.2 H 52.09” (1323mm) x W 17.65” (448mm) x D 10.34” (263mm)

IQ12000V 12000/3517 230/60/50 9.8/10.8 135/57c - (50Hz 140/60c) 135 / 61.2 H 52.09” (1323mm) x W 17.65” (448mm) x D 10.34” (263mm)

IQ12000V** 12000/3517 480/60/50 4.9/5.4 131/55c 173 / 78.5 H 57.65” (1464mm) x W 17.65” (448mm) x D 10.34” (263mm)

** Also available in 400V as non UL

10,0

00, &

12,

000

BTU

H

Conditioned Enclosure Air Flow

AmbientAir Flow

D

g g pp

2-24-15 Rev 1

Volts* BTU / Watts Max Amps Max Temp Weight HxWxD mm [“]

120 12,000 / 3517 19.6 131°F / 55°C 135 lbs. / 61.2 kg, 1323 x 448 x 263[52.09 x 17.65 x 10.34]

*AC unit available in 230V if required. Ask sales representative for details.

AC Unit