decontamination kits

39

Upload: byron-maynard

Post on 31-Dec-2015

81 views

Category:

Documents


5 download

DESCRIPTION

DETECTORS AND. DECONTAMINATION KITS. M-8 PAPER. Detects liquid nerve and blister agents. Turns 3 colors. Red for Blister agents. Yellow for G nerve agents. Green for V nerve agents. M-9 PAPER. Detects liquid nerve and blister agents. Sticks to clothing, vehicles and equipment. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: DECONTAMINATION KITS
Page 2: DECONTAMINATION KITS

M8 paper

Detects liquid nerve and blister agents.

Turns 3 colors. Red for Blister agents. Yellow for G nerve agents. Green for V nerve agents.

Page 3: DECONTAMINATION KITS

M9 paper

Detects liquid nerve and blister agents.

Sticks to clothing, vehicles and equipment.

Red is the only positive reading.

Contains a known carcinogen, use gloves when handling.

Page 4: DECONTAMINATION KITS

Detects nerve, blister and blood agents.

Detects both liquid and vapors. 12 detectors per kit.

Page 5: DECONTAMINATION KITS

Swing out the heater; remove and save two loose pads. Save pads under hinged heater. Swing heater back in place (Figure 5).

Page 6: DECONTAMINATION KITS

Remove the pull tab marked (1). Pull upward to expose the lewisite detecting tablet (Figure 6)

Page 7: DECONTAMINATION KITS

Bend the tab over the lewisiste detecting tablet.

Rub the upper half of the tab until a mark is visible (Figure 7).

Page 8: DECONTAMINATION KITS

Hold the sampler - detector with the test spots or arrows pointing up.

Using the heater pads, crush four ampoules in the three center pockets marked (3) (Figure 8).

Page 9: DECONTAMINATION KITS

Turn the sampler - detector upside down, and verify wetting of test spots.

Hold the sampler detector with the test spots or arrow pointing down.

Using the heater pads, squeeze the ampoules to force liquid through the formed channels (Figure 9).

Page 10: DECONTAMINATION KITS

Put your thumb on the protective strip over the middle of the test spot.

Swing the heater away from the test spot (Figure 10).

Page 11: DECONTAMINATION KITS

Activate the first heater ampoule marked #4.

Being sure to use the heater pads, crush one green ampoule, and swing the heater immediately over the test spot (Figure 11).

Page 12: DECONTAMINATION KITS

Hold the sampler detector to one side while venting to avoid vapor.

After 2 minutes swing the heater away from the test spot, and swing the protective strip away from test spots.

Expose test spots to air for 10 minutes (Figure 12).

Page 13: DECONTAMINATION KITS

After 10 minutes, activate the second heater ampoule marked (4). Being sure to use the heater pads, crush the second green ampoule. Swing the heater immediately over the test spot After 1 minute, swing the heater away from the test spot (Figure 13).

Page 14: DECONTAMINATION KITS

Hold the sampler detector with the test spots or arrows pointing down.

Using the heater pads, crush the remaining ampoules marked (5). Be sure to wet test spots by squeezing ampoules to force the liquid onto the test spots (Figure 14).

Page 15: DECONTAMINATION KITS

Re-rub the lewisite detecting tablet. Bend the tab over the lewisite detecting tablet.

Rub the bottom half of the tab until mark is visible (Figure 15).

Page 16: DECONTAMINATION KITS

Compare the colors to determine whether conditions are dangerous or safe.

Turn the sampler detector upside down, and compare the colors of the test spots with those shown on the sampler detector.

Look for a change in the color of the rubs on the lewisite detecting tab.

If your kit has a fourth instruction card, use it to compare the colors to determine whether conditions are dangerous or safe

Page 17: DECONTAMINATION KITS

Detects nerve and blister agents in vapor form (M-8A1 detects nerve only.

Consist of: M-42 Remote alarm. M-22 Agent detector. M-28 Power supply. The M-88 has replaced the M-

8A1, but is functionally the same.

M-88

Page 18: DECONTAMINATION KITS

Up to 400 Meters between detectors and alarms.

Up to 5 alarms per detector. Up to 300 Meters between

detectors. Place detectors 150 meters

Upwind of the FLOT.

Page 19: DECONTAMINATION KITS

M-42 M-42M-42M-42M-42 M-42 M-42M-42M-42M-42

150M

300MW IND

Place M-42 alarms a max distance of 400 M from the M-22’s.

M-22 M-22

Page 20: DECONTAMINATION KITS

Hard plastic olive drab case

Contains six packets, (3) number one packets and (3) number two packets.

Inspect for tears in packets.

Inspect for broken ampoules in number two packets.

Page 21: DECONTAMINATION KITS

Has replaced the M-258. Wallet like pouch with 6

decon packets. Black reactive and

absorbent resin powder. Attached strap for

inserting finger. Applied by patting not

rubbing.

Page 22: DECONTAMINATION KITS
Page 23: DECONTAMINATION KITS

Air Outlet

Filter

Filter AssemblyInlet Stack

Lid

Latch

Casing

Warning Labels

Power Connection

Power Connection Cover

Exhaust Hose

Page 24: DECONTAMINATION KITS
Page 25: DECONTAMINATION KITS

Provides Presumptive ID of BW Agents in Suspect Samples

Same Format as Home Pregnancy Test

Simple Operation, Inexpensive, Single Use

Results in 15 Minutes

Reliable

Rigorous QA/QC Testing

Low False Positive Rate

Presumptive ID Component in Currently Fielded and Developmental Joint BW Detection Systems (Portal Shield, JBPDS, DoD Biological Detection System, DFU)

Shelf Life: 2 Years at Refrigerated Temperatures (4°C)

Do Not Freeze

Panel of 8 HHAs

Page 26: DECONTAMINATION KITS

Chemical contamination - decon within one minute. Use M-291 or M-258. Note: Processes are the same for both kits. When

using the M-258 use packets in sequence. Biological contamination - wash down with soap

and water.

Page 27: DECONTAMINATION KITS

Process consist of wiping down your mask, gloves and essential gear.

Do not attempt to remove contamination from over-garment.

Most effective within fifteen minutes. Note: If M258 is used you must reverse the packet

sequence.

Page 28: DECONTAMINATION KITS
Page 29: DECONTAMINATION KITS
Page 30: DECONTAMINATION KITS
Page 31: DECONTAMINATION KITS
Page 32: DECONTAMINATION KITS
Page 33: DECONTAMINATION KITS
Page 34: DECONTAMINATION KITS
Page 35: DECONTAMINATION KITS
Page 36: DECONTAMINATION KITS
Page 37: DECONTAMINATION KITS
Page 38: DECONTAMINATION KITS
Page 39: DECONTAMINATION KITS