declaration of conformity - bigcommercepc-1407 rpt. date 5/9/2018 rpt. rev rev date dan redden...
TRANSCRIPT
X
Name Title Date
DoC Rev2 10.14.17
Authorized Signature
Mark Sasaki Director of Engineering 8.27.18
Level 1: FallTech Lab
Outside the Scope of
ISO/IEC Standard 17025:2005
Level 2: FallTech Lab
Within the Scope of
ISO/IEC Standard 17025:2005
Level 3: Independent 3rd Party Lab
accredited to
ISO/IEC Standard 17025:2005
Supporting
DocumentationPC-1407
Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with
the requirements of the following performance standard(s):
ANSI Z359.14-2014
Conformity Assessment Method in accordance with ANSI/ISEA 125-2014
Level 1 Level 2 Level 3
Tested Item # 7226CLE 15' DuraTech Self-Retracting Device, Leading Edge
Additional Items Conforming Under this Declaration:
Declaration of ConformityIn Accordance with ANSI/ISEA 125-2014
Alexander Andrew, Inc. 1306 S. Alameda St Compton, CA 90221
Declaration # D0518029b Declaration Date 5.10.18
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Material/Sample Identification
Sample ID Description
15' DuraTech Leading Edge SRD
FT15985 15' DuraTech Leading Edge SRD
FT15992 15' DuraTech Leading Edge SRD
FT15955 15' DuraTech Leading Edge SRD
Sara Martinez / Yesbet Sierra / Jay Sponholz
Date Complete 5/8/2018PC-1407
Test Operator(s)
Test Report No.
Test Request No.
Initiated By
Part No.
15' DuraTech Leading Edge SRD
FT15976
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
FT15988 15' DuraTech Leading Edge SRD
FT15945 15' DuraTech Leading Edge SRD
FT15976 15' DuraTech Leading Edge SRD
FT15978 15' DuraTech Leading Edge SRD
FT15963 15' DuraTech Leading Edge SRD
FT15923 15' DuraTech Leading Edge SRD
FT15528 15' DuraTech Leading Edge SRD
FT15533 15' DuraTech Leading Edge SRD
FT15434 15' DuraTech Leading Edge SRD
FT15988 15' DuraTech Leading Edge SRD
FT15945
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 1 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
FT15957 15' DuraTech Leading Edge SRD
FT15931 15' DuraTech Leading Edge SRD
FT15958 15' DuraTech Leading Edge SRD
FT15939 15' DuraTech Leading Edge SRD
FT15993 15' DuraTech Leading Edge SRD
FT15909 15' DuraTech Leading Edge SRD
FT15988 15' DuraTech Leading Edge SRD
FT15945 15' DuraTech Leading Edge SRD
FT15976 15' DuraTech Leading Edge SRD
FT15965 15' DuraTech Leading Edge SRD
FT15959 15' DuraTech Leading Edge SRD
FT15937 15' DuraTech Leading Edge SRD
FT15996 15' DuraTech Leading Edge SRD
FT15905 15' DuraTech Leading Edge SRD
FT15998 15' DuraTech Leading Edge SRD
Material/Sample Identification (Continued)
Sample ID Description
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 2 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
4.6 lbF Pass
Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.4 lbF
Pass/Fail
Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.2 lbF Pass
Clear evidence of
ActivationClear Activation Pass
ANSI Z359.14-2014
4.2.1, 4.2.6
Class A < 24"
Class B < 54"23.5" Pass
< 1800 Lbf 1159.9 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf881.9 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended2.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended
1.25 Lbf - 25 Lbf
< 60" Extended6.4 lbF
Test Summary
Test Specification Test Criteria Test Result
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 3 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
1.25 Lbf - 25 Lbf
< 60" Extended8.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.0 lbF Pass
ANSI Z359.14-2014
4.2.1, 4.2.6
Class A < 24"
Class B < 54"20.6" Pass
< 1800 Lbf 1259.2 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf931.3 lbF Pass
Clear evidence of
ActivationClear Activation Pass
1.25 Lbf - 25 Lbf
< 60" Extended3.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended3.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended5.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.4 lbF Pass
Test Criteria Test Result Pass/Fail
Test Summary (Continued)
Test Specification
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 4 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Class A < 24"
Class B < 54"18.8" Pass
ANSI Z359.14-2014
4.2.1, 4.2.6
< 1800 Lbf 1163.7 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf857.1 lbF Pass
Clear evidence of
ActivationClear Activation Pass
1.25 Lbf - 25 Lbf
< 60" Extended2.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended4.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.8 lbF Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 5 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Dynamic Strength
Line Constituent
Strength
Dynamic Strength
Line Constituent
Strength
Dynamic Strength
Line Constituent
Strength
Static Strength
Static Strength
Static Strength
Test Result Pass/Fail
ANSI Z359.14-2014
4.2.3
4' Fall w/ 300 Lb Test
Weight; Weight Shall Not
Strike the Ground
Did not strike ground Pass
> 1000 Lbf 1194.0 lbF Pass
ANSI Z359.14-2014
4.2.3
4' Fall w/ 300 Lb Test
Weight; Weight Shall Not
Strike the Ground
Did not strike ground Pass
> 1000 Lbf 1028.7 lbF Pass
ANSI Z359.14-2014
4.2.3
4' Fall w/ 300 Lb Test
Weight; Weight Shall Not
Strike the Ground
Did not strike ground Pass
> 1000 Lbf 1037.0 lbF Pass
ANSI Z359.14-2014
4.2.5
> 3,000 Lbf
for > 60 Seconds3054.9 lbF Pass
ANSI Z359.14-2014
4.2.5
> 3,000 Lbf
for > 60 Seconds3062.4 lbF Pass
ANSI Z359.14-2014
4.2.5
> 3,000 Lbf
for > 60 Seconds3488.8 lbF Pass
Test Summary (Continued)
Test Specification Test Criteria
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 6 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
ANSI Z359.14-2014
4.2.6
1.25 Lbf - 25 Lbf
< 60" Extended3.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended5.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.1 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.2 lbF Pass
ANSI Z359.14-2014
4.2.6
1.25 Lbf - 25 Lbf
< 60" Extended4.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended5.1 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.6 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.9 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended9.0 lbF Pass
ANSI Z359.14-2014
4.2.6
1.25 Lbf - 25 Lbf
< 60" Extended3.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended3.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.5 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.9 lbF Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 7 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
ANSI Z359.14-2014
4.2.1 / 4.2.8.1
Class A < 24"
Class B < 54"19.2" Pass
< 1800 Lbf 1424.4 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf992.3 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended2.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended4.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.8 lbF Pass
Clear evidence of
ActivationClear Activation Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 8 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
ANSI Z359.14-2014
4.2.1 / 4.2.8.2
Class A < 24"
Class B < 54"16.8" Pass
< 1800 Lbf 1494.8 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf1031.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended3.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended3.6 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended5.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended8.0 lbF Pass
Clear evidence of
ActivationClear Activation Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 9 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Retraction Tension
0% Extracted
Retraction Tension
20% Extracted
Retraction Tension
40% Extracted
Retraction Tension
60% Extracted
Retraction Tension
80% Extracted
Retraction Tension
100% Extracted
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Clear evidence of
ActivationClear Activation Pass
> 1 Minute 1 minute Pass
ANSI Z359.14-2014
4.2.2 (Perpendicular)
w/ 300 lb. and 2 min swing
option
Not Applicable 59.5"For Fall Clearance
Guidelines
< 1800 Lbf 1214.8 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf823.5 lbF Pass
> 1000 Lbf 1053.3 lbF Pass
ANSI Z359.14-2014
4.2.1 / 4.2.8.3
Class A < 24"
Class B < 54"18.7" Pass
< 1800 Lbf 1341.1 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf887.6 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended2.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended3.4 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended4.8 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended6.2 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.0 lbF Pass
1.25 Lbf - 25 Lbf
< 60" Extended7.6 lbF Pass
Clear evidence of
ActivationClear Activation Pass
Test Specification Test Criteria Test Result Pass/Fail
Test Summary (Continued)
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 10 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
1 minute Pass
ANSI Z359.14-2014
4.2.2 (Perpendicular)
w/ 300 lb. and 2 min swing
option
Not Applicable 59.8"For Fall Clearance
Guidelines
< 1800 Lbf 1119.7 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf816.9 lbF Pass
> 1000 Lbf 1021.9 lbF Pass
> 1 Minute 1 minute Pass
Clear evidence of
ActivationClear Activation Pass
Clear evidence of
ActivationClear Activation Pass
ANSI Z359.14-2014
4.2.2 (Perpendicular)
w/ 300 lb. and 2 min swing
option
Not Applicable 58.4"For Fall Clearance
Guidelines
< 1800 Lbf 1223.4 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf835.2 lbF Pass
> 1000 Lbf 1034.1 lbF Pass
> 1 Minute
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 11 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Not Applicable 74.8"For Fall Clearance
Guidelines
< 1800 Lbf 1299.9 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf855.2 lbF Pass
> 1000 Lbf 1029.8 lbF Pass
> 1 Minute
ANSI Z359.14-2014
4.2.2 (Lateral Offset)
w/ 300 lb. and 2 min swing
option
Clear evidence of
ActivationClear Activation Pass
< 1800 Lbf 1201.3 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf844.1 lbF Pass
> 1000 Lbf 1041.6 lbF Pass
> 1 Minute 1 minute Pass
Test Criteria
Not Applicable 78.8"For Fall Clearance
Guidelines
ANSI Z359.14-2014
4.2.2 (Lateral Offset)
w/ 300 lb. and 2 min swing
option
1 minute Pass
Clear evidence of
ActivationClear Activation Pass
Test Result Pass/Fail
Test Summary (Continued)
Test Specification
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 12 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
> 1000 Lbf 1034.1 lbF Pass
> 1 Minute 1 minute Pass
< 1800 Lbf 1417.1 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf861.9 lbF Pass
Clear evidence of
ActivationClear Activation Pass
< 1800 Lbf 1309.6 lbF Pass
Class A < 1350 Lbf
Class B < 900 Lbf825.4 lbF Pass
> 1000 Lbf 1029.0 lbF Pass
Not Applicable 87.0"For Fall Clearance
Guidelines
Pass
Pass/Fail
Not Applicable 64.8"For Fall Clearance
Guidelines
ANSI Z359.14-2014
4.2.2 / 4.2.8.1
(Perpendicular)
w/ 300 lb. and 2 min swing
option
> 1 Minute 1 minute Pass
ANSI Z359.14-2014
4.2.2 (Lateral Offset)
w/ 300 lb. and 2 min swing
option
Clear evidence of
ActivationClear Activation
Test Summary (Continued)
Test Specification Test Criteria Test Result
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 13 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
ANSI Z359.14-2014
4.2.2 / 4.2.8.2
(Perpendicular)
w/ 300 lb. and 2 min swing
option
Not Applicable 53.3"
< 1800 Lbf 1312.6 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf948.3 lbF
> 1000 Lbf 1099.5 lbF Pass
> 1 Minute 1 minute Pass
Pass
Class A < 1575 Lbf
Class B < 1125 Lbf870.8 lbF
Clear evidence of
ActivationClear Activation
< 1800 Lbf 1394.8 lbF
Clear evidence of
ActivationClear Activation Pass
> 1000 Lbf 1032.3 lbF Pass
> 1 Minute 1 minute Pass
Pass
For Fall Clearance
Guidelines
Pass
Pass
Pass/Fail
Test Summary (Continued)
Test Specification Test Criteria Test Result
ANSI Z359.14-2014
4.2.2 / 4.2.8.1
(Lateral Offset)
w/ 300 lb. and 2 min swing
option
Not Applicable 78.4"For Fall Clearance
Guidelines
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 14 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
57.1"For Fall Clearance
Guidelines
< 1800 Lbf 1112.6 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf814.8 lbF Pass
Clear evidence of
ActivationClear Activation Pass
> 1 Minute 1 minute Pass
> 1 Minute 1 minute Pass
Test Summary (Continued)
Test Specification Test Criteria Test Result
ANSI Z359.14-2014
4.2.2 / 4.2.8.2
(Lateral Offset)
w/ 300 lb. and 2 min swing
option
Not Applicable 64.2"For Fall Clearance
Guidelines
< 1800 Lbf 1414.2 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf914.3 lbF Pass
Clear evidence of
ActivationClear Activation Pass
> 1000 Lbf 1167.7 lbF Pass
> 1000 Lbf 1018.1 lbF Pass
ANSI Z359.14-2014
4.2.2 / 4.2.8.3
(Perpendicular)
w/ 300 lb. and 2 min swing
option
Not Applicable
Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 15 of 38
FallTech Testing Laboratory 1306 S. Alameda Street,
Compton, CA 90221-4803
Tel: (323) 752-0060
www.falltech.com
PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date
Dan Redden
Date Complete 5/8/2018PC-1407
Test Report No.
Test Request No.
Initiated By
Part No.
FallTech Test Report
Test Specification(s)
Part Description
ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,
4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3
FallTech
15' DuraTech Leading Edge SRD
Part No. Revision C7226CLE
Report Prepared For
Arrest Distance
Max Arrest Force
Avg Arrest Force
Load Indicator
Line Constituent
Strength
Line Constituent
Hold Force
Horizontal Retraction
Horizontal Retraction
Horizontal Retraction
78.7"For Fall Clearance
Guidelines
< 1800 Lbf 1549.0 lbF Pass
Class A < 1575 Lbf
Class B < 1125 Lbf819.8 lbF Pass
Clear evidence of
ActivationClear Activation
ANSI Z359.14-2014
4.2.2 / 4.2.8.3
(Lateral Offset)
w/ 300 lb. and 2 min swing
option
Not Applicable
> 1 Minute 1 minute Pass
1026.1 lbF Pass
ANSI Z359.14-2014
4.2.7
Controlled Retraction at
2 - 5 feet per second
without stopping
No Hesitation in
RetractionPass
ANSI Z359.14-2014
4.2.7
Controlled Retraction at
2 - 5 feet per second
without stopping
No Hesitation in
RetractionPass
ANSI Z359.14-2014
4.2.7
Controlled Retraction at
2 - 5 feet per second
without stopping
No Hesitation in
RetractionPass
Pass
> 1000 Lbf
Test Summary (Continued)
Test Specification Test Criteria Test Result Pass/Fail
Certificate# TL-594 Testing
FLT-08 Rev. H
Page 16 of 38