X Name Title Date DoC Rev2 10.14.17 Authorized Signature Mark Sasaki Director of Engineering 8.27.18 Level 1: FallTech Lab Outside the Scope of ISO/IEC Standard 17025:2005 Level 2: FallTech Lab Within the Scope of ISO/IEC Standard 17025:2005 Level 3: Independent 3rd Party Lab accredited to ISO/IEC Standard 17025:2005 Supporting Documentation PC-1407 Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with the requirements of the following performance standard(s): ANSI Z359.14-2014 Conformity Assessment Method in accordance with ANSI/ISEA 125-2014 Level 1 Level 2 Level 3 Tested Item # 7226CLE 15' DuraTech Self-Retracting Device, Leading Edge Additional Items Conforming Under this Declaration: Declaration of Conformity In Accordance with ANSI/ISEA 125-2014 Alexander Andrew, Inc. 1306 S. Alameda St Compton, CA 90221 Declaration # D0518029b Declaration Date 5.10.18

Upload: others

Post on 16-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

X

Name Title Date

DoC Rev2 10.14.17

Authorized Signature

Mark Sasaki Director of Engineering 8.27.18

Level 1: FallTech Lab

Outside the Scope of

ISO/IEC Standard 17025:2005

Level 2: FallTech Lab

Within the Scope of

ISO/IEC Standard 17025:2005

Level 3: Independent 3rd Party Lab

accredited to

ISO/IEC Standard 17025:2005

Supporting

DocumentationPC-1407

Alexander Andrew, Inc. declares that the product(s) listed above is in conformity with

the requirements of the following performance standard(s):

ANSI Z359.14-2014

Conformity Assessment Method in accordance with ANSI/ISEA 125-2014

Level 1 Level 2 Level 3

Tested Item # 7226CLE 15' DuraTech Self-Retracting Device, Leading Edge

Additional Items Conforming Under this Declaration:

Declaration of ConformityIn Accordance with ANSI/ISEA 125-2014

Alexander Andrew, Inc. 1306 S. Alameda St Compton, CA 90221

Declaration # D0518029b Declaration Date 5.10.18

Page 2: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985
Page 3: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985
Page 4: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Material/Sample Identification

Sample ID Description

15' DuraTech Leading Edge SRD

FT15985 15' DuraTech Leading Edge SRD

FT15992 15' DuraTech Leading Edge SRD

FT15955 15' DuraTech Leading Edge SRD

Sara Martinez / Yesbet Sierra / Jay Sponholz

Date Complete 5/8/2018PC-1407

Test Operator(s)

Test Report No.

Test Request No.

Initiated By

Part No.

15' DuraTech Leading Edge SRD

FT15976

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

FT15988 15' DuraTech Leading Edge SRD

FT15945 15' DuraTech Leading Edge SRD

FT15976 15' DuraTech Leading Edge SRD

FT15978 15' DuraTech Leading Edge SRD

FT15963 15' DuraTech Leading Edge SRD

FT15923 15' DuraTech Leading Edge SRD

FT15528 15' DuraTech Leading Edge SRD

FT15533 15' DuraTech Leading Edge SRD

FT15434 15' DuraTech Leading Edge SRD

FT15988 15' DuraTech Leading Edge SRD

FT15945

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 1 of 38

Page 5: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

FT15957 15' DuraTech Leading Edge SRD

FT15931 15' DuraTech Leading Edge SRD

FT15958 15' DuraTech Leading Edge SRD

FT15939 15' DuraTech Leading Edge SRD

FT15993 15' DuraTech Leading Edge SRD

FT15909 15' DuraTech Leading Edge SRD

FT15988 15' DuraTech Leading Edge SRD

FT15945 15' DuraTech Leading Edge SRD

FT15976 15' DuraTech Leading Edge SRD

FT15965 15' DuraTech Leading Edge SRD

FT15959 15' DuraTech Leading Edge SRD

FT15937 15' DuraTech Leading Edge SRD

FT15996 15' DuraTech Leading Edge SRD

FT15905 15' DuraTech Leading Edge SRD

FT15998 15' DuraTech Leading Edge SRD

Material/Sample Identification (Continued)

Sample ID Description

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 2 of 38

Page 6: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

4.6 lbF Pass

Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.4 lbF

Pass/Fail

Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.2 lbF Pass

Clear evidence of

ActivationClear Activation Pass

ANSI Z359.14-2014

4.2.1, 4.2.6

Class A < 24"

Class B < 54"23.5" Pass

< 1800 Lbf 1159.9 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf881.9 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended2.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended

1.25 Lbf - 25 Lbf

< 60" Extended6.4 lbF

Test Summary

Test Specification Test Criteria Test Result

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 3 of 38

Page 7: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

1.25 Lbf - 25 Lbf

< 60" Extended8.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.0 lbF Pass

ANSI Z359.14-2014

4.2.1, 4.2.6

Class A < 24"

Class B < 54"20.6" Pass

< 1800 Lbf 1259.2 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf931.3 lbF Pass

Clear evidence of

ActivationClear Activation Pass

1.25 Lbf - 25 Lbf

< 60" Extended3.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended3.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended5.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.4 lbF Pass

Test Criteria Test Result Pass/Fail

Test Summary (Continued)

Test Specification

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 4 of 38

Page 8: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

Class A < 24"

Class B < 54"18.8" Pass

ANSI Z359.14-2014

4.2.1, 4.2.6

< 1800 Lbf 1163.7 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf857.1 lbF Pass

Clear evidence of

ActivationClear Activation Pass

1.25 Lbf - 25 Lbf

< 60" Extended2.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended4.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.8 lbF Pass

Test Summary (Continued)

Test Specification Test Criteria Test Result Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 5 of 38

Page 9: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Dynamic Strength

Line Constituent

Strength

Dynamic Strength

Line Constituent

Strength

Dynamic Strength

Line Constituent

Strength

Static Strength

Static Strength

Static Strength

Test Result Pass/Fail

ANSI Z359.14-2014

4.2.3

4' Fall w/ 300 Lb Test

Weight; Weight Shall Not

Strike the Ground

Did not strike ground Pass

> 1000 Lbf 1194.0 lbF Pass

ANSI Z359.14-2014

4.2.3

4' Fall w/ 300 Lb Test

Weight; Weight Shall Not

Strike the Ground

Did not strike ground Pass

> 1000 Lbf 1028.7 lbF Pass

ANSI Z359.14-2014

4.2.3

4' Fall w/ 300 Lb Test

Weight; Weight Shall Not

Strike the Ground

Did not strike ground Pass

> 1000 Lbf 1037.0 lbF Pass

ANSI Z359.14-2014

4.2.5

> 3,000 Lbf

for > 60 Seconds3054.9 lbF Pass

ANSI Z359.14-2014

4.2.5

> 3,000 Lbf

for > 60 Seconds3062.4 lbF Pass

ANSI Z359.14-2014

4.2.5

> 3,000 Lbf

for > 60 Seconds3488.8 lbF Pass

Test Summary (Continued)

Test Specification Test Criteria

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 6 of 38

Page 10: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

ANSI Z359.14-2014

4.2.6

1.25 Lbf - 25 Lbf

< 60" Extended3.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended5.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.1 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.2 lbF Pass

ANSI Z359.14-2014

4.2.6

1.25 Lbf - 25 Lbf

< 60" Extended4.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended5.1 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.6 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.9 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended9.0 lbF Pass

ANSI Z359.14-2014

4.2.6

1.25 Lbf - 25 Lbf

< 60" Extended3.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended3.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.5 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.9 lbF Pass

Test Summary (Continued)

Test Specification Test Criteria Test Result Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 7 of 38

Page 11: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

ANSI Z359.14-2014

4.2.1 / 4.2.8.1

Class A < 24"

Class B < 54"19.2" Pass

< 1800 Lbf 1424.4 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf992.3 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended2.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended4.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.8 lbF Pass

Clear evidence of

ActivationClear Activation Pass

Test Summary (Continued)

Test Specification Test Criteria Test Result Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 8 of 38

Page 12: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

ANSI Z359.14-2014

4.2.1 / 4.2.8.2

Class A < 24"

Class B < 54"16.8" Pass

< 1800 Lbf 1494.8 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf1031.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended3.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended3.6 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended5.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended8.0 lbF Pass

Clear evidence of

ActivationClear Activation Pass

Test Summary (Continued)

Test Specification Test Criteria Test Result Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 9 of 38

Page 13: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Retraction Tension

0% Extracted

Retraction Tension

20% Extracted

Retraction Tension

40% Extracted

Retraction Tension

60% Extracted

Retraction Tension

80% Extracted

Retraction Tension

100% Extracted

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Clear evidence of

ActivationClear Activation Pass

> 1 Minute 1 minute Pass

ANSI Z359.14-2014

4.2.2 (Perpendicular)

w/ 300 lb. and 2 min swing

option

Not Applicable 59.5"For Fall Clearance

Guidelines

< 1800 Lbf 1214.8 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf823.5 lbF Pass

> 1000 Lbf 1053.3 lbF Pass

ANSI Z359.14-2014

4.2.1 / 4.2.8.3

Class A < 24"

Class B < 54"18.7" Pass

< 1800 Lbf 1341.1 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf887.6 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended2.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended3.4 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended4.8 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended6.2 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.0 lbF Pass

1.25 Lbf - 25 Lbf

< 60" Extended7.6 lbF Pass

Clear evidence of

ActivationClear Activation Pass

Test Specification Test Criteria Test Result Pass/Fail

Test Summary (Continued)

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 10 of 38

Page 14: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

1 minute Pass

ANSI Z359.14-2014

4.2.2 (Perpendicular)

w/ 300 lb. and 2 min swing

option

Not Applicable 59.8"For Fall Clearance

Guidelines

< 1800 Lbf 1119.7 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf816.9 lbF Pass

> 1000 Lbf 1021.9 lbF Pass

> 1 Minute 1 minute Pass

Clear evidence of

ActivationClear Activation Pass

Clear evidence of

ActivationClear Activation Pass

ANSI Z359.14-2014

4.2.2 (Perpendicular)

w/ 300 lb. and 2 min swing

option

Not Applicable 58.4"For Fall Clearance

Guidelines

< 1800 Lbf 1223.4 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf835.2 lbF Pass

> 1000 Lbf 1034.1 lbF Pass

> 1 Minute

Test Summary (Continued)

Test Specification Test Criteria Test Result Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 11 of 38

Page 15: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Not Applicable 74.8"For Fall Clearance

Guidelines

< 1800 Lbf 1299.9 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf855.2 lbF Pass

> 1000 Lbf 1029.8 lbF Pass

> 1 Minute

ANSI Z359.14-2014

4.2.2 (Lateral Offset)

w/ 300 lb. and 2 min swing

option

Clear evidence of

ActivationClear Activation Pass

< 1800 Lbf 1201.3 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf844.1 lbF Pass

> 1000 Lbf 1041.6 lbF Pass

> 1 Minute 1 minute Pass

Test Criteria

Not Applicable 78.8"For Fall Clearance

Guidelines

ANSI Z359.14-2014

4.2.2 (Lateral Offset)

w/ 300 lb. and 2 min swing

option

1 minute Pass

Clear evidence of

ActivationClear Activation Pass

Test Result Pass/Fail

Test Summary (Continued)

Test Specification

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 12 of 38

Page 16: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

> 1000 Lbf 1034.1 lbF Pass

> 1 Minute 1 minute Pass

< 1800 Lbf 1417.1 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf861.9 lbF Pass

Clear evidence of

ActivationClear Activation Pass

< 1800 Lbf 1309.6 lbF Pass

Class A < 1350 Lbf

Class B < 900 Lbf825.4 lbF Pass

> 1000 Lbf 1029.0 lbF Pass

Not Applicable 87.0"For Fall Clearance

Guidelines

Pass

Pass/Fail

Not Applicable 64.8"For Fall Clearance

Guidelines

ANSI Z359.14-2014

4.2.2 / 4.2.8.1

(Perpendicular)

w/ 300 lb. and 2 min swing

option

> 1 Minute 1 minute Pass

ANSI Z359.14-2014

4.2.2 (Lateral Offset)

w/ 300 lb. and 2 min swing

option

Clear evidence of

ActivationClear Activation

Test Summary (Continued)

Test Specification Test Criteria Test Result

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 13 of 38

Page 17: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

ANSI Z359.14-2014

4.2.2 / 4.2.8.2

(Perpendicular)

w/ 300 lb. and 2 min swing

option

Not Applicable 53.3"

< 1800 Lbf 1312.6 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf948.3 lbF

> 1000 Lbf 1099.5 lbF Pass

> 1 Minute 1 minute Pass

Pass

Class A < 1575 Lbf

Class B < 1125 Lbf870.8 lbF

Clear evidence of

ActivationClear Activation

< 1800 Lbf 1394.8 lbF

Clear evidence of

ActivationClear Activation Pass

> 1000 Lbf 1032.3 lbF Pass

> 1 Minute 1 minute Pass

Pass

For Fall Clearance

Guidelines

Pass

Pass

Pass/Fail

Test Summary (Continued)

Test Specification Test Criteria Test Result

ANSI Z359.14-2014

4.2.2 / 4.2.8.1

(Lateral Offset)

w/ 300 lb. and 2 min swing

option

Not Applicable 78.4"For Fall Clearance

Guidelines

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 14 of 38

Page 18: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

57.1"For Fall Clearance

Guidelines

< 1800 Lbf 1112.6 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf814.8 lbF Pass

Clear evidence of

ActivationClear Activation Pass

> 1 Minute 1 minute Pass

> 1 Minute 1 minute Pass

Test Summary (Continued)

Test Specification Test Criteria Test Result

ANSI Z359.14-2014

4.2.2 / 4.2.8.2

(Lateral Offset)

w/ 300 lb. and 2 min swing

option

Not Applicable 64.2"For Fall Clearance

Guidelines

< 1800 Lbf 1414.2 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf914.3 lbF Pass

Clear evidence of

ActivationClear Activation Pass

> 1000 Lbf 1167.7 lbF Pass

> 1000 Lbf 1018.1 lbF Pass

ANSI Z359.14-2014

4.2.2 / 4.2.8.3

(Perpendicular)

w/ 300 lb. and 2 min swing

option

Not Applicable

Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 15 of 38

Page 19: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985

FallTech Testing Laboratory 1306 S. Alameda Street,

Compton, CA 90221-4803

Tel: (323) 752-0060

www.falltech.com

PC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date

Dan Redden

Date Complete 5/8/2018PC-1407

Test Report No.

Test Request No.

Initiated By

Part No.

FallTech Test Report

Test Specification(s)

Part Description

ANSI Z359.14-2014: 3.1.5, 4.2.1, 4.2.2, 4.2.3,

4.2.5, 4.2.6, 4.2.7, 4.2.8.1, 4.2.8.2, 4.2.8.3

FallTech

15' DuraTech Leading Edge SRD

Part No. Revision C7226CLE

Report Prepared For

Arrest Distance

Max Arrest Force

Avg Arrest Force

Load Indicator

Line Constituent

Strength

Line Constituent

Hold Force

Horizontal Retraction

Horizontal Retraction

Horizontal Retraction

78.7"For Fall Clearance

Guidelines

< 1800 Lbf 1549.0 lbF Pass

Class A < 1575 Lbf

Class B < 1125 Lbf819.8 lbF Pass

Clear evidence of

ActivationClear Activation

ANSI Z359.14-2014

4.2.2 / 4.2.8.3

(Lateral Offset)

w/ 300 lb. and 2 min swing

option

Not Applicable

> 1 Minute 1 minute Pass

1026.1 lbF Pass

ANSI Z359.14-2014

4.2.7

Controlled Retraction at

2 - 5 feet per second

without stopping

No Hesitation in

RetractionPass

ANSI Z359.14-2014

4.2.7

Controlled Retraction at

2 - 5 feet per second

without stopping

No Hesitation in

RetractionPass

ANSI Z359.14-2014

4.2.7

Controlled Retraction at

2 - 5 feet per second

without stopping

No Hesitation in

RetractionPass

Pass

> 1000 Lbf

Test Summary (Continued)

Test Specification Test Criteria Test Result Pass/Fail

Certificate# TL-594 Testing

FLT-08 Rev. H

Page 16 of 38

Page 20: Declaration of Conformity - BigCommercePC-1407 Rpt. Date 5/9/2018 Rpt. Rev Rev Date Dan Redden Material/Sample Identification Sample ID Description 15' DuraTech Leading Edge SRD FT15985