december 28, 2020 report, project description and site map
TRANSCRIPT
21 Griffin Road North Windsor Connecticut 06095 • Phone. 860.298.9692 • Fax. 860.298.6399
December 28, 2020
Mr. Adam Fox, P.E.Principal EngineerEnvironmental Compliance SectionBureau of Engineering and ConstructionState of Connecticut Department of Transportation2800 Berlin Turnpike, P.O. Box 317546Newington, CT 06131-7546
Attention: Amie Maines, P.E. / Ronnie Vella
Subject: On-Call Asbestos, Lead, Air Quality & Demolition ComplianceAgreement No.: 8.07-01 (18)HazMat Inspection - Bridge No. 05844, I-84 over Route 15, East Hartford, CT ConnDOT Assignment No. 519-6317ConnDOT Project No. 42-325TRC Project No. 289951.6317.0710
Dear Mr. Fox:
TRC performed a limited survey for hazardous building materials associated with the rehabilitation of Bridge No. 05844, I-84 Route 15, in East Hartford, Connecticut. Results of the survey identified no detectable levels of lead in the coating of the structural steel & metal bridge components at Bridge No. 05844. Since no detectable levels of lead were in the coating, any paint waste would be non-hazardous, non-RCRA waste. Suspect asbestos containing materials in the form of black vinyl bearing pads, white caulking on parapet joints and silicone caulking were sampled and found to contain no detectable levels of asbestos. No bird/pigeon guano accumulations or bloodborne pathogen (BBP) concerns were observed in accessible areas of Bridge No. 05844, however it is anticipated that some guano may be found during the course of the project. Potential Universal Waste & Connecticut Regulated Waste in the form of a light pole by Bridge No. 05844 was identified, however it is not expected to be impacted. Associated laboratory data, TRC Mobile Data report, project description and site map are attached.
If you have any questions, please call TRC at (860) 298-9692.
Very Truly Yours,
TRC
Stephen R. Arienti, CHMMSenior Project Scientist – Program Manager
Erik R. Plimpton, P.E., CHMM, CMCVice President – Engineer in Charge
Page 1 of 1
Lead paint includes paint found to contain any detectable amount of lead by Atomic Absorption Spectrophotometry (AAS) or X-Ray Fluorescence (XRF). Side A = Street side; Sides B,C,D follow clockwise
Lead Based Paint Measurement Summary TableDevice(s): Niton XLP301-A (Serial #24792) X Ray Fluorescence (XRF) Spectrum AnalyzerSite: ConnDOT - Bridge No. 05844, East Hartford, CTProject # : 289951.6317.0710Date(s): 9/2/2020Inspectors: Mike Stewart
Number Interior/Exterior Location Bridge No. Side Structure Feature Material Color Condition Reading
(mg/cm2)Precision(mg/cm2)
DepthIndex
Duration(sec) Date/Time
1 Self Calibration 54.4 9/2/2020 10:012 0.7 Calibration 0.7 0.1 1.1 12.7 9/2/2020 10:033 1.6 Calibration 1.5 0.1 1.1 10.9 9/2/2020 10:034 3.6 Calibration 3.6 0.2 1.3 10.9 9/2/2020 10:035 VOID6 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 4.8 7.2 9/2/2020 10:447 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 5.4 19.5 9/2/2020 10:458 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 4.4 10.4 9/2/2020 10:459 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 4.3 15.9 9/2/2020 10:46
10 VOID11 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 1.0 6.8 9/2/2020 10:4712 VOID13 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 3.2 8.2 9/2/2020 10:4814 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 1.0 6.8 9/2/2020 10:4915 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 2.3 8.6 9/2/2020 10:4916 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 1.0 2.3 9/2/2020 10:5017 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 1.0 8.2 9/2/2020 10:5018 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 7.8 14.5 9/2/2020 10:5219 VOID20 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 1.9 5.0 9/2/2020 10:5321 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 1.2 4.1 9/2/2020 10:5422 VOID23 VOID24 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 1.0 4.6 9/2/2020 10:5525 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 6.8 14.5 9/2/2020 10:5526 0.7 Calibration 0.6 0.1 1.1 8.1 9/2/2020 11:0327 1.6 Calibration 1.4 0.9 1.1 0.5 9/2/2020 11:0328 1.6 Calibration 1.5 0.1 1.2 10.9 9/2/2020 11:0429 3.6 Calibration 3.7 0.2 1.3 12.2 9/2/2020 11:04
80 Lupes Drive
Stratford, CT 06615
Tel: (203) 377-9984
Fax: (203) 377-9952
e-mail: [email protected]
Client: Mr. Stephen Arienti
TRC Environmental Consultants
21 Griffin Rd., North
Windsor, CT 06095
Analytical Report
CET# 0090134
Report Date:September 08, 2020
Project: CTDOT, Bridge 05844A
Project Number: 289951.6317.0710
Pennsylvania Certificate: 68-02927Massachusetts Laboratory Certificate: M-CT903
Connecticut Laboratory Certificate: PH 0116 New York NELAP Accreditation: 11982
Rhode Island Laboratory Certificate: 199
Page 1 of 5
Project Number: 289951.6317.0710
Project: CTDOT, Bridge 05844A
CET # : 0090134
Sample ID Laboratory ID Matrix Collection Date/Time Receipt Date
SAMPLE SUMMARY
The sample(s) were received at 23.0 C.
This report contains analytical data associated with following samples only.
01-5844A 0090134-01 Paint Chip 09/03/20209/02/2020
Notes
Date/Time
AnalyzedPreparedBatchDilutionRLResultLaboratory ID Client Sample ID Units
Analyst: EAS
Matrix: Paint ChipPrep: EPA 3051A
Analyte: Total Lead [EPA 6010C]
09/04/2020 09/04/2020 20:070090134-01 %01-5844A 0.10 1 B0I0420ND
No collection time provided by client on chain of custody for the following sample: 0090134-01.
CASE NARRATIVE
80 Lupes Drive, Stratford, CT 06615 � Tel: 203-377-9984 � Fax: 203-377-9952 � www.cetlabs.com
Complete Environmental Testing, Inc.
Page 2 of 5
Project Number: 289951.6317.0710
Project: CTDOT, Bridge 05844A
CET # : 0090134
Sincerely,
David Ditta
Laboratory Director
Report Comments:
Sample Result Flags:
E- The result is estimated, above the calibration range.
H- The surrogate recovery is above the control limits.
L- The surrogate recovery is below the control limits.
B- The compound was detected in the laboratory blank.
P- The Relative Percent Difference (RPD) of dual column analyses exceeds 40%.
D- The RPD between the sample and the sample duplicate is high. Sample Homogeneity may be a problem.
+- The Surrogate was diluted out.
*C1- The Continuing Calibration did not meet method specifications and was biased low for this analyte. Increased uncertainty is
associated with the reported value which is likely to be biased low.
*C2- The Continuing Calibration did not meet method specifications and was biased high for this analyte. Increased uncertainty
is associated with the reported value which is likely to be biased high.
*F1- The Laboratory Control Sample recovery is outside of control limits. Reported value for this analyte is likely to be biased
on the low side.
*F2- The Laboratory Control Sample recovery is outside of control limits. Reported value for this analyte is likely to be biased
on the high side.
*I- Analyte exceeds method limits from second source standard in Initial Calibration Verification (ICV). No directional bias.
All results met standard operating procedures unless indicated by a data qualifier next to a sample result, or a narration in the QC
report.
For Percent Solids, if any of the following prep methods (3050B, 3540C, 3545A, 3550C, 5035 and 9013A) were used for
samples pertaining to this report, the percent solids procedure is within that prep method.
Complete Environmental Testing is only responsible for the certified testing and is not directly responsible for the integrity of the
sample before laboratory receipt.
ND is None Detected at or above the specified reporting limit
Reporting Limit (RL) is the limit of detection for an analyte after any adjustment made for dilution or percent moisture.
All analyses were performed in house unless a Reference Laboratory is listed.
Samples will be disposed of 30 days after the report date.
All questions related to this report should be directed to David Ditta, Timothy Fusco, or Robert Blake at 203-377-9984.
Project Manager
This technical report was reviewed by Robert Blake
80 Lupes Drive, Stratford, CT 06615 � Tel: 203-377-9984 � Fax: 203-377-9952 � www.cetlabs.com
Complete Environmental Testing, Inc.
Page 3 of 5
Project Number: 289951.6317.0710
Project: CTDOT, Bridge 05844A
CET # : 0090134
CertificationsAnalyte
CERTIFICATIONS
Certified Analyses included in this Report
EPA 6010C in Solid
CT,NY,PALead
Complete Environmental Testing operates under the following certifications and accreditations :
Code Description Number Expires
Connecticut Public Health 09/30/2020CT PH0116
New York Certification (NELAC) 04/01/2021NY 11982
Pennsylvania DEP 05/31/2021PA 68-02927
80 Lupes Drive, Stratford, CT 06615 � Tel: 203-377-9984 � Fax: 203-377-9952 � www.cetlabs.com
Complete Environmental Testing, Inc.
Page 4 of 5
Page 1 of 1Industrial Hygiene Laboratory21 Griffin Road NorthWindsor, CT 06095(860) 298-6308
55563.CT-DOT.doc
Lab Log #: 0055563
Bridge 05844A, I84 over Rt. 15, East Hartford, CT
CLIENT: CT Department of Transportation
Site:
Date Analyzed:
Date Received:
09/03/2020
09/03/2020
Project #: 289951.6317.0710
BULK ASBESTOS ANALYSIS REPORT
Layer No. AsbestosType
Other MatrixMaterialsSample No. Homogenous
Asbestos%
POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116
ColorMulti-
Layered
synthetic fiber None- -1 ND30%Yes NoBlack (vinyl bearing pad)
synthetic fiber None- -2 ND30%Yes NoBlack (vinyl bearing pad)
- - - None- -3 NDYes NoWhite (caulk)
- - - None- -4 NDYes NoWhite (caulk)
- - - None- -5 NDYes NoGrey (caulking)
- - - None- -6 NDYes NoGrey (caulking)
Reporting limit- asbestos present at 1% Trace - asbestos was observed at level of less than 1%NA/PS - Not Analyzed / Positive Stop SNA- Sample Not Analyzed- See Chain of Custody for details
The Laboratory at TRC follows the EPA's Interim Method for the Determination of Asbestos in Bulk Insulation 1982 (EPA 600/M4-82-020) Bulk Analysis Code 18/A01 and the EPA recommended Method for the Determination of Asbestos in Bulk Building Materials July 1993, R.L. Perkins and B.W. Harvey, (EPA/600/R-93/116) Bulk Analysis Code 18/A03, which utilize polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 18/A01, effective through June 30, 2021. TRC is accredited by the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC in the Industrial Hygiene Program (IHLAP) for PLM effective through October 1, 2020. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and QC data related to the samples is available upon written request from client.
This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested.
ND - asbestos was not detected
Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, EPA recommends, and certain states (e.g. NY) require, that negative results be confirmed by quantitative transmission electron microscopy.
Analyzed by: Reviewed by: Date Issued
09/04/2020Kathleen Williamson, Laboratory Manager Joel Corso, Approved Signatory
TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS
NVLAP Lab Code 101424-0RI #PLM0007 TX #300354 CO# AL-15020
AIHA-LAP,LLC #100122VT #AL910359 LA#05011 PHIL# 461
CT #PH-0426VA #3333 000283 PA#68-03387
NY #10980NJ #CT004
WV #000622CA #2907
ME LA-0075, LB-0071AZ #A20944
MA #AA000052HI #L-09-004
WinBSI HBM Survey
Page 1 of 9
WinBSI HBM SurveyConnDOT, Bridge 05844A, I84 Over Rt 15 East Hartford CT06118 US9/14/2020, 2:03:20 PM EDT
CREATED
9/2/2020, 10:21:39 AM EDTby Michael Stewart
UPDATED
9/14/2020, 2:03:20 PM EDTby Stephen Arienti
STATUS
Survey Complete
LOCATION
41.760780, -72.641546
PROJECT
No Project
ASSIGNED TO
No Assignment
WinBSI HBM Survey
Page 2 of 9
Job Information
Site Name Bridge 05844A
Address I84 Over Rt 15 East Hartford CT 06118 US
TRC Project Number 289951.6317.0710
Project Manager Stephen Arienti
Inspector(s) Michael Stewart, Pat Schaffner
Client ConnDOT
Type of Asbestos Survey Reno/Demo
Additional Analysis for NOBMaterials (Calc)
TEM NY NOB 198.4
PLM Turnaround Time (TAT) 48-hour
TEM Turnaround Time (TAT) 48-hour
Date September 2, 2020
General Notes Rust color bridge No apparent protective coating
WinBSI HBM Survey
Page 4 of 9
Surveys Performed Asbestos, XRF, Hazardous Materials Inventory, Bridge/Signs/Light Pole/Traffic Signal Items
Asbestos Section
Asbestos Survey (3 Items)
Asbestos Survey - 1. ( 2 ), C ▸ 1, Black vinyl bearing pad, 2
Representative Photos
Asbestos Samples (2 Items)
Asbestos Samples - 1. East end on south side
Asbestos Samples - 2. West end on south side
WinBSI HBM Survey
Page 5 of 9
Material Information
Sampled or Assumed? Sampled
Material Acronym C ▸ 1
Material Description Black vinyl bearing pad
Is Material a Non-Friable OrganicallyBound (NOB)
Yes
Homogeneous Area Under bearing rocker plates and under railing posts on parapet
Total Approximate Quantity Entire length of bridge both sides
Notes
Total Count ( 2 )
Asbestos Survey - 2. ( 2 ), C ▸ 2, White caulk , 2
Representative Photos
Asbestos Samples (2 Items)
WinBSI HBM Survey
Page 6 of 9
Asbestos Samples - 1. East end middle Parapet joint
Asbestos Samples - 2. West end middle
Material Information
Sampled or Assumed? Sampled
Material Acronym C ▸ 2
Material Description White caulk
Is Material a Non-Friable OrganicallyBound (NOB)
Yes
Homogeneous Area In parapet joint
Total Approximate Quantity Approximately 70 locations on both sides of bridge - 3LF each
Notes
Total Count ( 2 )
Asbestos Survey - 3. ( 2 ), C ▸ 3, Silicon caulking , 2
Representative Photos
Asbestos Samples (2 Items)
Asbestos Samples - 1. East end south side
Asbestos Samples - 2. East end south side
Material Information
Sampled or Assumed? Sampled
Material Acronym C ▸ 3
Material Description Silicon caulking
Is Material a Non-Friable OrganicallyBound (NOB)
Yes
WinBSI HBM Survey
Page 7 of 9
Homogeneous Area South side parapet Also observed on north side
Total Approximate Quantity 12 locations total 3LF each
Notes
Total Count ( 2 )
XRF Section
Niton XRF Model No. 24792
XRF Survey Completed Yes
XRF Data Downloaded Yes
XRF Shots >1.0 on non-metallicbuilding materials
No
Date Data Downloaded September 2, 2020
HAZMAT Inventory Section
Inventory Area (1 Item)
Inventory Area - 1.
Inventory Area Description
HAZMAT Items
Bridge/Signs/Light Pole/Traffic Signal Items
Bridge/Signs/Light Pole/Traffic Signal No. (1 Item)
Bridge/Signs/Light Pole/Traffic Signal No. - 1. 05844A
Bridge/Sign/Light Pole/Traffic SignalNo.
05844A
General Notes Rust bridge no apparent protective coating
Accessibility Accessible
Paint on Structure (s)? No
Suspect Asbestos ContainingMaterials Identified on Structure
Yes
WinBSI HBM Survey
Page 8 of 9
Guano Present? No
Homeless Activity No
Bloodborne Pathogen Concerns? No
Mice/Mouse Nests/Droppings No
General Information
Site Sketch Diagrams
WinBSI HBM Survey
Page 9 of 9
Signature
Signed 9/2/2020, 3:24:04 PM EDT
Asbestos Samples Submitted to TRCLab
Yes
Date Submitted to Lab September 2, 2020
App Name WinBSI HBM Survey 1.0
Generate Report Documentation
Select one or more documents belowto be generated. Once completed inthe cloud, they will be sent to thelisted email address. Please reportany difficulties or errors to JustinColeman.
What documents should begenerated?
Asbestos chain-of-custody
Where should the document(s) besent?
Generate Documents