21 Griffin Road North Windsor Connecticut 06095 • Phone. 860.298.9692 • Fax. 860.298.6399 December 28, 2020 Mr. Adam Fox, P.E. Principal Engineer Environmental Compliance Section Bureau of Engineering and Construction State of Connecticut Department of Transportation 2800 Berlin Turnpike, P.O. Box 317546 Newington, CT 06131-7546 Attention: Amie Maines, P.E. / Ronnie Vella Subject: On-Call Asbestos, Lead, Air Quality & Demolition Compliance Agreement No.: 8.07-01 (18) HazMat Inspection - Bridge No. 05844, I-84 over Route 15, East Hartford, CT ConnDOT Assignment No. 519-6317 ConnDOT Project No. 42-325 TRC Project No. 289951.6317.0710 Dear Mr. Fox: TRC performed a limited survey for hazardous building materials associated with the rehabilitation of Bridge No. 05844, I-84 Route 15, in East Hartford, Connecticut. Results of the survey identified no detectable levels of lead in the coating of the structural steel & metal bridge components at Bridge No. 05844. Since no detectable levels of lead were in the coating, any paint waste would be non-hazardous, non-RCRA waste. Suspect asbestos containing materials in the form of black vinyl bearing pads, white caulking on parapet joints and silicone caulking were sampled and found to contain no detectable levels of asbestos. No bird/pigeon guano accumulations or bloodborne pathogen (BBP) concerns were observed in accessible areas of Bridge No. 05844, however it is anticipated that some guano may be found during the course of the project. Potential Universal Waste & Connecticut Regulated Waste in the form of a light pole by Bridge No. 05844 was identified, however it is not expected to be impacted. Associated laboratory data, TRC Mobile Data report, project description and site map are attached. If you have any questions, please call TRC at (860) 298-9692. Very Truly Yours, TRC Stephen R. Arienti, CHMM Senior Project Scientist – Program Manager Erik R. Plimpton, P.E., CHMM, CMC Vice President – Engineer in Charge

Upload: others

Post on 16-Oct-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

21 Griffin Road North Windsor Connecticut 06095 • Phone. 860.298.9692 • Fax. 860.298.6399

December 28, 2020

Mr. Adam Fox, P.E.Principal EngineerEnvironmental Compliance SectionBureau of Engineering and ConstructionState of Connecticut Department of Transportation2800 Berlin Turnpike, P.O. Box 317546Newington, CT 06131-7546

Attention: Amie Maines, P.E. / Ronnie Vella

Subject: On-Call Asbestos, Lead, Air Quality & Demolition ComplianceAgreement No.: 8.07-01 (18)HazMat Inspection - Bridge No. 05844, I-84 over Route 15, East Hartford, CT ConnDOT Assignment No. 519-6317ConnDOT Project No. 42-325TRC Project No. 289951.6317.0710

Dear Mr. Fox:

TRC performed a limited survey for hazardous building materials associated with the rehabilitation of Bridge No. 05844, I-84 Route 15, in East Hartford, Connecticut. Results of the survey identified no detectable levels of lead in the coating of the structural steel & metal bridge components at Bridge No. 05844. Since no detectable levels of lead were in the coating, any paint waste would be non-hazardous, non-RCRA waste. Suspect asbestos containing materials in the form of black vinyl bearing pads, white caulking on parapet joints and silicone caulking were sampled and found to contain no detectable levels of asbestos. No bird/pigeon guano accumulations or bloodborne pathogen (BBP) concerns were observed in accessible areas of Bridge No. 05844, however it is anticipated that some guano may be found during the course of the project. Potential Universal Waste & Connecticut Regulated Waste in the form of a light pole by Bridge No. 05844 was identified, however it is not expected to be impacted. Associated laboratory data, TRC Mobile Data report, project description and site map are attached.

If you have any questions, please call TRC at (860) 298-9692.

Very Truly Yours,

TRC

Stephen R. Arienti, CHMMSenior Project Scientist – Program Manager

Erik R. Plimpton, P.E., CHMM, CMCVice President – Engineer in Charge

Page 1 of 1

Lead paint includes paint found to contain any detectable amount of lead by Atomic Absorption Spectrophotometry (AAS) or X-Ray Fluorescence (XRF). Side A = Street side; Sides B,C,D follow clockwise

Lead Based Paint Measurement Summary TableDevice(s): Niton XLP301-A (Serial #24792) X Ray Fluorescence (XRF) Spectrum AnalyzerSite: ConnDOT - Bridge No. 05844, East Hartford, CTProject # : 289951.6317.0710Date(s): 9/2/2020Inspectors: Mike Stewart

Number Interior/Exterior Location Bridge No. Side Structure Feature Material Color Condition Reading

(mg/cm2)Precision(mg/cm2)

DepthIndex

Duration(sec) Date/Time

1 Self Calibration 54.4 9/2/2020 10:012 0.7 Calibration 0.7 0.1 1.1 12.7 9/2/2020 10:033 1.6 Calibration 1.5 0.1 1.1 10.9 9/2/2020 10:034 3.6 Calibration 3.6 0.2 1.3 10.9 9/2/2020 10:035 VOID6 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 4.8 7.2 9/2/2020 10:447 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 5.4 19.5 9/2/2020 10:458 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 4.4 10.4 9/2/2020 10:459 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 4.3 15.9 9/2/2020 10:46

10 VOID11 Exterior East Hartford Bridge No 05844 East Beam Metal Brown Defective 0.0 0.0 1.0 6.8 9/2/2020 10:4712 VOID13 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 3.2 8.2 9/2/2020 10:4814 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 1.0 6.8 9/2/2020 10:4915 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 2.3 8.6 9/2/2020 10:4916 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 1.0 2.3 9/2/2020 10:5017 Exterior East Hartford Bridge No 05844 East Bearing Metal Brown Defective 0.0 0.0 1.0 8.2 9/2/2020 10:5018 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 7.8 14.5 9/2/2020 10:5219 VOID20 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 1.9 5.0 9/2/2020 10:5321 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 1.2 4.1 9/2/2020 10:5422 VOID23 VOID24 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 1.0 4.6 9/2/2020 10:5525 Exterior East Hartford Bridge No 05844 East Truss Metal Brown Defective 0.0 0.0 6.8 14.5 9/2/2020 10:5526 0.7 Calibration 0.6 0.1 1.1 8.1 9/2/2020 11:0327 1.6 Calibration 1.4 0.9 1.1 0.5 9/2/2020 11:0328 1.6 Calibration 1.5 0.1 1.2 10.9 9/2/2020 11:0429 3.6 Calibration 3.7 0.2 1.3 12.2 9/2/2020 11:04

80 Lupes Drive

Stratford, CT 06615

Tel: (203) 377-9984

Fax: (203) 377-9952

e-mail: [email protected]

Client: Mr. Stephen Arienti

TRC Environmental Consultants

21 Griffin Rd., North

Windsor, CT 06095

Analytical Report

CET# 0090134

Report Date:September 08, 2020

Project: CTDOT, Bridge 05844A

Project Number: 289951.6317.0710

Pennsylvania Certificate: 68-02927Massachusetts Laboratory Certificate: M-CT903

Connecticut Laboratory Certificate: PH 0116 New York NELAP Accreditation: 11982

Rhode Island Laboratory Certificate: 199

Page 1 of 5

Project Number: 289951.6317.0710

Project: CTDOT, Bridge 05844A

CET # : 0090134

Sample ID Laboratory ID Matrix Collection Date/Time Receipt Date

SAMPLE SUMMARY

The sample(s) were received at 23.0 C.

This report contains analytical data associated with following samples only.

01-5844A 0090134-01 Paint Chip 09/03/20209/02/2020

Notes

Date/Time

AnalyzedPreparedBatchDilutionRLResultLaboratory ID Client Sample ID Units

Analyst: EAS

Matrix: Paint ChipPrep: EPA 3051A

Analyte: Total Lead [EPA 6010C]

09/04/2020 09/04/2020 20:070090134-01 %01-5844A 0.10 1 B0I0420ND

No collection time provided by client on chain of custody for the following sample: 0090134-01.

CASE NARRATIVE

80 Lupes Drive, Stratford, CT 06615 � Tel: 203-377-9984 � Fax: 203-377-9952 � www.cetlabs.com

Complete Environmental Testing, Inc.

Page 2 of 5

Project Number: 289951.6317.0710

Project: CTDOT, Bridge 05844A

CET # : 0090134

Sincerely,

David Ditta

Laboratory Director

Report Comments:

Sample Result Flags:

E- The result is estimated, above the calibration range.

H- The surrogate recovery is above the control limits.

L- The surrogate recovery is below the control limits.

B- The compound was detected in the laboratory blank.

P- The Relative Percent Difference (RPD) of dual column analyses exceeds 40%.

D- The RPD between the sample and the sample duplicate is high. Sample Homogeneity may be a problem.

+- The Surrogate was diluted out.

*C1- The Continuing Calibration did not meet method specifications and was biased low for this analyte. Increased uncertainty is

associated with the reported value which is likely to be biased low.

*C2- The Continuing Calibration did not meet method specifications and was biased high for this analyte. Increased uncertainty

is associated with the reported value which is likely to be biased high.

*F1- The Laboratory Control Sample recovery is outside of control limits. Reported value for this analyte is likely to be biased

on the low side.

*F2- The Laboratory Control Sample recovery is outside of control limits. Reported value for this analyte is likely to be biased

on the high side.

*I- Analyte exceeds method limits from second source standard in Initial Calibration Verification (ICV). No directional bias.

All results met standard operating procedures unless indicated by a data qualifier next to a sample result, or a narration in the QC

report.

For Percent Solids, if any of the following prep methods (3050B, 3540C, 3545A, 3550C, 5035 and 9013A) were used for

samples pertaining to this report, the percent solids procedure is within that prep method.

Complete Environmental Testing is only responsible for the certified testing and is not directly responsible for the integrity of the

sample before laboratory receipt.

ND is None Detected at or above the specified reporting limit

Reporting Limit (RL) is the limit of detection for an analyte after any adjustment made for dilution or percent moisture.

All analyses were performed in house unless a Reference Laboratory is listed.

Samples will be disposed of 30 days after the report date.

All questions related to this report should be directed to David Ditta, Timothy Fusco, or Robert Blake at 203-377-9984.

Project Manager

This technical report was reviewed by Robert Blake

80 Lupes Drive, Stratford, CT 06615 � Tel: 203-377-9984 � Fax: 203-377-9952 � www.cetlabs.com

Complete Environmental Testing, Inc.

Page 3 of 5

Project Number: 289951.6317.0710

Project: CTDOT, Bridge 05844A

CET # : 0090134

CertificationsAnalyte

CERTIFICATIONS

Certified Analyses included in this Report

EPA 6010C in Solid

CT,NY,PALead

Complete Environmental Testing operates under the following certifications and accreditations :

Code Description Number Expires

Connecticut Public Health 09/30/2020CT PH0116

New York Certification (NELAC) 04/01/2021NY 11982

Pennsylvania DEP 05/31/2021PA 68-02927

80 Lupes Drive, Stratford, CT 06615 � Tel: 203-377-9984 � Fax: 203-377-9952 � www.cetlabs.com

Complete Environmental Testing, Inc.

Page 4 of 5

Page 5 of 5

Page 1 of 1Industrial Hygiene Laboratory21 Griffin Road NorthWindsor, CT 06095(860) 298-6308

55563.CT-DOT.doc

Lab Log #: 0055563

Bridge 05844A, I84 over Rt. 15, East Hartford, CT

CLIENT: CT Department of Transportation

Site:

Date Analyzed:

Date Received:

09/03/2020

09/03/2020

Project #: 289951.6317.0710

BULK ASBESTOS ANALYSIS REPORT

Layer No. AsbestosType

Other MatrixMaterialsSample No. Homogenous

Asbestos%

POLARIZED LIGHT MICROSCOPY by EPA 600/R-93/116

ColorMulti-

Layered

synthetic fiber None- -1 ND30%Yes NoBlack (vinyl bearing pad)

synthetic fiber None- -2 ND30%Yes NoBlack (vinyl bearing pad)

- - - None- -3 NDYes NoWhite (caulk)

- - - None- -4 NDYes NoWhite (caulk)

- - - None- -5 NDYes NoGrey (caulking)

- - - None- -6 NDYes NoGrey (caulking)

Reporting limit- asbestos present at 1% Trace - asbestos was observed at level of less than 1%NA/PS - Not Analyzed / Positive Stop SNA- Sample Not Analyzed- See Chain of Custody for details

The Laboratory at TRC follows the EPA's Interim Method for the Determination of Asbestos in Bulk Insulation 1982 (EPA 600/M4-82-020) Bulk Analysis Code 18/A01 and the EPA recommended Method for the Determination of Asbestos in Bulk Building Materials July 1993, R.L. Perkins and B.W. Harvey, (EPA/600/R-93/116) Bulk Analysis Code 18/A03, which utilize polarized light microscopy (PLM). Our analysts have completed an accredited course in asbestos identification. TRC's Laboratory is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), for Bulk Asbestos Fiber Analysis, NVLAP Code 18/A01, effective through June 30, 2021. TRC is accredited by the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC in the Industrial Hygiene Program (IHLAP) for PLM effective through October 1, 2020. Asbestos content is determined by visual estimate unless otherwise indicated. Quality Control is performed in-house on at least 10% of samples and QC data related to the samples is available upon written request from client.

This report shall not be reproduced, except in full, without the written approval of TRC. This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the items tested.

ND - asbestos was not detected

Note: Polarized-light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. In those cases, EPA recommends, and certain states (e.g. NY) require, that negative results be confirmed by quantitative transmission electron microscopy.

Analyzed by: Reviewed by: Date Issued

09/04/2020Kathleen Williamson, Laboratory Manager Joel Corso, Approved Signatory

TRC LABORATORY ASBESTOS ANALYTICAL ACCREDITATIONS

NVLAP Lab Code 101424-0RI #PLM0007 TX #300354 CO# AL-15020

AIHA-LAP,LLC #100122VT #AL910359 LA#05011 PHIL# 461

CT #PH-0426VA #3333 000283 PA#68-03387

NY #10980NJ #CT004

WV #000622CA #2907

ME LA-0075, LB-0071AZ #A20944

MA #AA000052HI #L-09-004

WinBSI HBM Survey

Page 1 of 9

WinBSI HBM SurveyConnDOT, Bridge 05844A, I84 Over Rt 15 East Hartford CT06118 US9/14/2020, 2:03:20 PM EDT

CREATED

9/2/2020, 10:21:39 AM EDTby Michael Stewart

UPDATED

9/14/2020, 2:03:20 PM EDTby Stephen Arienti

STATUS

Survey Complete

LOCATION

41.760780, -72.641546

PROJECT

No Project

ASSIGNED TO

No Assignment

WinBSI HBM Survey

Page 2 of 9

Job Information

Site Name Bridge 05844A

Address I84 Over Rt 15 East Hartford CT 06118 US

TRC Project Number 289951.6317.0710

Project Manager Stephen Arienti

Inspector(s) Michael Stewart, Pat Schaffner

Client ConnDOT

Type of Asbestos Survey Reno/Demo

Additional Analysis for NOBMaterials (Calc)

TEM NY NOB 198.4

PLM Turnaround Time (TAT) 48-hour

TEM Turnaround Time (TAT) 48-hour

Date September 2, 2020

General Notes Rust color bridge No apparent protective coating

WinBSI HBM Survey

Page 3 of 9

Overview Photo

WinBSI HBM Survey

Page 4 of 9

Surveys Performed Asbestos, XRF, Hazardous Materials Inventory, Bridge/Signs/Light Pole/Traffic Signal Items

Asbestos Section

Asbestos Survey (3 Items)

Asbestos Survey - 1. ( 2 ), C ▸ 1, Black vinyl bearing pad, 2

Representative Photos

Asbestos Samples (2 Items)

Asbestos Samples - 1. East end on south side

Asbestos Samples - 2. West end on south side

WinBSI HBM Survey

Page 5 of 9

Material Information

Sampled or Assumed? Sampled

Material Acronym C ▸ 1

Material Description Black vinyl bearing pad

Is Material a Non-Friable OrganicallyBound (NOB)

Yes

Homogeneous Area Under bearing rocker plates and under railing posts on parapet

Total Approximate Quantity Entire length of bridge both sides

Notes

Total Count ( 2 )

Asbestos Survey - 2. ( 2 ), C ▸ 2, White caulk , 2

Representative Photos

Asbestos Samples (2 Items)

WinBSI HBM Survey

Page 6 of 9

Asbestos Samples - 1. East end middle Parapet joint

Asbestos Samples - 2. West end middle

Material Information

Sampled or Assumed? Sampled

Material Acronym C ▸ 2

Material Description White caulk

Is Material a Non-Friable OrganicallyBound (NOB)

Yes

Homogeneous Area In parapet joint

Total Approximate Quantity Approximately 70 locations on both sides of bridge - 3LF each

Notes

Total Count ( 2 )

Asbestos Survey - 3. ( 2 ), C ▸ 3, Silicon caulking , 2

Representative Photos

Asbestos Samples (2 Items)

Asbestos Samples - 1. East end south side

Asbestos Samples - 2. East end south side

Material Information

Sampled or Assumed? Sampled

Material Acronym C ▸ 3

Material Description Silicon caulking

Is Material a Non-Friable OrganicallyBound (NOB)

Yes

WinBSI HBM Survey

Page 7 of 9

Homogeneous Area South side parapet Also observed on north side

Total Approximate Quantity 12 locations total 3LF each

Notes

Total Count ( 2 )

XRF Section

Niton XRF Model No. 24792

XRF Survey Completed Yes

XRF Data Downloaded Yes

XRF Shots >1.0 on non-metallicbuilding materials

No

Date Data Downloaded September 2, 2020

HAZMAT Inventory Section

Inventory Area (1 Item)

Inventory Area - 1.

Inventory Area Description

HAZMAT Items

Bridge/Signs/Light Pole/Traffic Signal Items

Bridge/Signs/Light Pole/Traffic Signal No. (1 Item)

Bridge/Signs/Light Pole/Traffic Signal No. - 1. 05844A

Bridge/Sign/Light Pole/Traffic SignalNo.

05844A

General Notes Rust bridge no apparent protective coating

Accessibility Accessible

Paint on Structure (s)? No

Suspect Asbestos ContainingMaterials Identified on Structure

Yes

WinBSI HBM Survey

Page 8 of 9

Guano Present? No

Homeless Activity No

Bloodborne Pathogen Concerns? No

Mice/Mouse Nests/Droppings No

General Information

Site Sketch Diagrams

WinBSI HBM Survey

Page 9 of 9

Signature

Signed 9/2/2020, 3:24:04 PM EDT

Asbestos Samples Submitted to TRCLab

Yes

Date Submitted to Lab September 2, 2020

App Name WinBSI HBM Survey 1.0

Generate Report Documentation

Select one or more documents belowto be generated. Once completed inthe cloud, they will be sent to thelisted email address. Please reportany difficulties or errors to JustinColeman.

What documents should begenerated?

Asbestos chain-of-custody

Where should the document(s) besent?

[email protected]

Generate Documents