ddi602am outdoor dual pir/am detector … outdoor dual pir/am detector installation sheet figure 4...

11
EN DE ES FR IT NL PL PT SV Figure 1 Figure 2 Figure 3 DDI602AM Outdoor Dual PIR/AM Detector Installation Sheet

Upload: voquynh

Post on 26-Mar-2018

221 views

Category:

Documents


2 download

TRANSCRIPT

EN DE ES FR IT NL PL PT SV

Figure 1

Figure 2 Figure 3

DDI602AM Outdoor Dual PIR/AM Detector Installation Sheet

Figure 4 Figure 5

Figure 6 Figure 7

Figure 8

TOP

Figure 9

Figure 10

Figure 11

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m 0m 2m 4m6m8m

10m

1.5m

-2°

TOP

MASK THIS SECTION OFF FOR PET ALLEY APPLICATIONS UP

TO 30m

TOP

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m 0m 2m 4m6m8m

10m

6m

Note: This setup has not been tested to EN50131-2-4

TOP

Long range 30m section

Short/ medium range 6m to 20m section

24 26 28 30m 0m 2m

4m

6m8m

10m

0 2 4 6 8 10 12 14 16 18 20 22

3m

Note: EN50131-2-4 Grade 3 compliance requires 3m mounting height and 0º adjustment, or 1.5 mounting height and -2º adjustment.

Figure 12

Figure 13

0 2 4 6 8 10m

0m

2m

4m

2m

4m70°

1 2

Figure 14

1. Microwave Coverage2. PIR Coverage

1. Microwave Coverage2. PIR Coverage

45°

MASK THIS SECTION OFF FOR CURTAIN

COVERAGE APPLICATIONS

0 2 4 6 8 0 2m

4m

6m

8m10m

6m

0 2 4 6 8 10 12 14 16m0

2m

4m

6m

8m10m

70°

02m4m6m8m

10m12m

2m4m6m8m

10m12m

0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m

1 2

Note: This setup has not been tested to EN50131-2-4

Figure 15

Ja

Jt

J TEOL

Jf

alarm n/c

tamper

fault

alarm n/o

Ja

1

2

Figure 15a

3

40V

+12V

ALARM N/O

ALARM N/O

TAMPER

TAMPER

ALARM N/C

ALARM N/C

FAULT A/M

FAULT A/M

REMOTE TEST

REMOTE LED

DEOL

TEOL

Legend:

J TEOL: Jumper to enable TEOL. Figure 15a, Item 1

Ja: Jumper to set EOL resistor value for alarm. Figure 15a, item 2

Jt: Jumper to set EOL resistor value for standby. Figure 15a, item 3

Jf: Jumper to set EOL resistor value for fault. Figure 15a, item 4

Figure 16

1.

Event Default (Ohm) CALCULATIONTAMPER (SHORT) 0 CLOSED CIRCUIT

STANDBY 4K7 Rt

ALARM 9K4 Rt + Ra

FAULT 14K7 Rt + Rf

ANTI MASK 19K4 Rt + Ra + Rf

TAMPER (OPEN) Inf. OPEN CIRCUIT

EXAMPLE USING 4K7 TAMPER, 4K7 ALARM AND 10K FAULT/A-M RESISTORS ALSO TEOL JUMPER SELECTED

REMOVE ALL JUMPERS FOR ISOLATED OUTPUTS

Single zone TEOL Calculation

Event Default (Ohm) CALCULATIONTAMPER (SHORT) 0 CLOSED CIRCUIT

STANDBY 4K7 Rt

ALARM 9K4 Rt + Ra

TAMPER (OPEN) Inf. OPEN CIRCUIT

EXAMPLE USING 4K7 TAMPER AND 4K7 ALARM RESISTORS REMOVE ALL JUMPERS FOR ISOLATED OUTPUTS

Single zone DEOL Calculation

Figure 17 Figure 18

2.

1.LED2.Button

1. 2. 3. 4. 5.

EN: Installation Sheet

Package

The package contains:•1 x DDI602AM•1 x drilling template for fixing holes•3 x 31.75 mm wall plugs•3 x 31.75 mm screws•1 x lens mask•2 x additional curtain shutters•1 x tamper cup•2 x tamper caps (different lengths)•1 x plastic locking tool•1 x installation sheet•1 x front cover screw cap

Introduction

The DDI602AM Outdoor Dual PIR/AM Detector is an external motion detector and alarm trigger that uses two independent passive infrared detectors plus a microwave sensor module.

Programmable options include a variable pulse count and a choice of three detection ranges: 10m, 20m and 30m.

Mounting the unit

When positioning the detector please consider that the PIR sensor is more sensitive to a movement across the beams, and less sensitive to a movement directly towards or away from the beams; whilst the microwave sensor is more sensitive to movement towards and away from the sensor.

During installation, protect the electronics against water, as trapped moisture can affect or damage the unit.

We recommend that the cable entry and screw mounting holes be sealed from within the detector using acrylic (non-silicone based) sealants.

Note: When locating the detector, please ensure the detector’s field of view is unobstructed.

To mount the detector:

1.Drill the wall to accept the fixing screws, the cable entry, and the tamper cup (if used). See Figures 1 and 3. A hole-drilling template is provided.

Notes•Leave a minimum 10 cm (4 inches) clearance above the top of the detector housing to allow the cover and the detector to be positioned correctly.

•We recommend using the tamper cup on uneven wall surfaces. See Fig 3.

•The recommended optimum mounting height for the detector is 3 m. Whilst it is possible to mount the unit higher, this will give a reduced detection range and will require the detection subject to move further through the already reduced detection area before activation is signalled.

•When mounting the units side by side, a minimum space of 1 m must be left between the detectors and the detectors must not be looking directly towards each other. No minimum space is required when mounting the units back to back.

2.Remove the cover assembly by loosening the locking screw. Squeeze the sides of the front cover to release the internal catches. The cover hinges from the top and lifts out of the location slot. See Figure 2.

3.Use a razor knife to open a rubber seal to allow the cabling into the unit (see Figure 4). Feed standard eight-core or 12-core alarm cable though the wall and directly into the cable entry. Bare the wires and connect to the top PCB terminal block (Figure 15)

Caution: Do not allow the cable to be trapped between the rear gasket and the mounting surface as this may cause water ingress. For surface mount cables use the conduit knock-out at the bottom of the detector. Refer Fig 1 for good and bad cable routings.

4.Screw the unit to the wall ensuring that the tamper pin is correctly located and that the tamper micro-switch is closed. Always ensure the detector base is screwed tightly to the wall so that the tamper foot is pushed into the rear rubber gasket. On uneven surfaces use the tamper cup and locate the tamper foot into the cup. Drilling template is provided.

To aid installation, two spare tamper feet are provided. One is 1 mm shorter and the other is 1 mm longer than the tamper foot originally fitted. The tamper foot is a push fit and can be removed by carefully pulling it from the pin. See Figure 1.

5.When the detector is aligned, connected, and programmed to suit the installation:

a. Fit the cover to the detector base.

b. Lightly screw the locking screw.

c. Put the top of the locking tool into the small notch on each side of the cover, and then apply slight pressure until the cover locks into the base, as shown in Figure 5.

d. Tighten the locking screw.

Connecting the unit

The DDI602AM includes jumpers that let you configure internal Triple End-of-Line (TEOL) resistor values, when TEOL resistors are required. Values are: 1, 2.2, 3.3, 4.7, 5.6, and 6.8 kΩ for Alarm and Tamper (DEOL resistors). The values are 2.2, 3.3, 4.7, 5.6 and 10kΩ for Fault/Anti-Mask. Figure 15 shows.

When using TEOL connections insert the TEOL jumper and select the three required resistor values for Fault/A Mask, Alarm and Tamper.

When using DEOL connections remove the TEOL jumper and select the two required resistor values for Alarm and Tamper.

Figure 15 shows:

1.TEOL resistor jumpers

2.Wiring points

3.TEOL enable used in conjunction with a jumper at the required resistance

Alternatively, you can remove the jumpers and connect a discrete resistor directly to the alarm, tamper or Fault/Anti-Mask outputs as specified by third-party equipment.

The wiring schematic in Figure 15 shows how to connect and the table in figure 16 shows how to calculate DEOL and TEOL values with examples.

Table 1: Connections

Terminal Label Description

1 LED Remote LED enable

2 TEST Remote TEST input

3, 4 FAULT/MASK Fault/Anti-Mask relay normally closed

4, 5 TEOL Triple End-of-Line resistors

5,7 DEOL Double End-of-Line resistors

5, 6 ALARM N/C Alarm relay, normally closed

7, 8 TAMPER N/C

Tamper relay, normally closed

9, 10 ALARM N/O Alarm relay, normally open

11, 12 +, − 12V DC 12 V DC power supply

Multi-beam alignment and masking

The multifunction lens fitted to the DDI602AM detector produces seven long-range beams and seven medium- to short-range curtain PIR beams. The PIR circuitry detects changes in heat and movement in the beam pattern. Items such as trees, shrubs, ponds, boiler flues, and animals should be considered when positioning the detector. The microwave module detects actual movement towards or away from the detector and is programmed to ignore any objects that move outside of the preselected detection range.

The detector module is fitted with two sliding shutters to reduce the detection angle.

The curtains are fitted to the pan and tilt module as shown in Figure 6. Each section of the detector lens gives a coverage pattern of approximately 10 degrees.

An additional set of curtain sliders is provided should the beam pattern be narrowed even further, e.g. if the minimum detection angle of 10 degrees is required.

When coverage exceeds the desired detection area, adjust the module as required and mask off any beams, either vertically or horizontally, to avoid unwanted detection.

Use portions of the self-adhesive silver mask applied to the rear, smooth side of the lens as shown in Figures 9 to 12. Gently lift the top and bottom edges of the pan and tilt module to release the lens. To replace the lens, please begin by sliding one side of the lens into the clips on the pan and tilt module. After one side is secure, do the same for the opposite side. Once both sides are secure, gently lift the top and bottom edges of the pan and tilt module and press on the lens to click it into place.

Always replace the lens the correct way up to ensure exact beam pattern coverage. The top of the lens is marked TOP as shown in Figure 7. There is a locating notch on the top of the pan and tilt module that locates into the cut-out on the top of the lens.

Table 2 below summarizes typical masking configurations for use when the range option is set to 30 meters.

Configuration Height Tilt Max. Range (m) (°) (m) Reference

Multi-beam, optimum

3 0 30 Figure 9

Multi-beam 6 9 25 Figure 10

Pet immunity [1] 1.5 −2 30 Figure 11

Curtain coverage [2]

6 45 5 Figure 12

[1]Black area should be masked for pet alley applications up to 30 meters.

[2]Black area should be masked for curtain coverage applications.

Figure 13 shows the pattern for the maximum range in the optimum position (see Figure 9). Masking the top section of the lens reduces the range to 20 m.

Figure 14 shows the pattern for the minimum range (10 m) In this case masking the top section of the lens reduces the range to 6 meters.

LEDs

LEDs are shown on Figure 18.

Figure 18 legend

Item Colour Description

1. Red PIR Active

2. Green Microwave active

3. Red (small) Anti-Mask

4. Blue Detection alarm

5. Infrared Walk tester communication

Programmable options

Pulse count

Pulse count is the number of times the detector must detect a presence before signalling an alarm.When the pulse count is set to 1, the detector is most sensitive.

Detection LED enabled

•Off: Detection LED is disabled•On: Detection LED signals detection

Programming

Figure 17 legend Item Description

1. Programming LED (red)

2. Programming button

All available settings are listed in Table 3 below.

Table 3: Programming settings

Value Option 1 2 3

1. Range (m)

10 20 30*

2. Pulse count

1* 2

3. Detection LED

OFF* ON

* Default settings

To change any of DDI602AM settings:

Note: Only the top PCB red LED is used in programming the detector.

1.Press the programming button to select the option number you want to change. Press once for range, twice for pulse count, and three times for detection LED.

2.Wait until the programming (red) LED turns off (typically 4 seconds).

3.Count the number of times the programming LED flashes to determine the current value for that option.

4.Press the programming button to select the value number for the new setting. Example: To set the range to 30m press three times.

The programming LED blinks twice to indicate that the new value was set.

Any alterations made to DDI602AM settings are stored in the detector’s non volatile memory.

Example

To change the detection LED setting from OFF to ON:

1.Press the programming button three times.

2.Wait until the programming LED turns off.

3.The programming LED flashes once to show that the current value is off.

4.Press the programming button twice.

5.The programming LED flashes twice showing that the new value has been stored. The detector returns to normal operation.

Resetting options

To reset the detector to the default settings:

1.Remove the power from the detector.

2.Press and hold the programming button (see Figure 17, item 2).

3.Apply the power to the detector.

4.After the programming LED flashes, release the programming button.

You can reset the detector either before installation, with a PP3 battery, or by applying 12 V to the unit on site.

Walk test

In walk test mode, the blue detection LED option is set to ON. The detection LED lights each time the DDI602AM detects your presence.

To enter the walk test mode, press the programming button once. The unit can then be aligned. The detection LED lights on the DDI602AM every time detection takes place.

The test mode ends automatically five minutes after last detection. Alternatively, press the program button three times, or remove and then reapply power to cancel the walk test mode.

Note: When you conduct a walk test, make sure that the front cover is in place. Do not conduct walk tests with the cover removed.

CAUTIONThe range of the detector increases without the protective front cover. Therefore the front cover must be fitted to establish the correct beam pattern. Use Table 3 to adjust the range as necessary. Pan and tilt the lens module over the field of view to obtain the correct coverage area (See Figure 8).

Fault/Anti-Mask Circuit

Fault/Anti-Mask technology prevents deliberate disabling of the detector by monitoring for obstruction of the detection equipment.

Operation

For the first two minutes the Fault/Anti-Mask relay can remain open.

After installation the detector needs to self-calibrate and this is done by entering walk test mode. After 2 minutes of selecting walk test the Anti-Mask will self-calibrate so the front cover must be securely fitted. After 5 minutes of selecting walk test the test will end.

After a Fault/Anti-Mask has been detected constantly for one minute then the Fault/Anti-Mask alarm contact opens and remains open until either the cause of masking is removed or the detector performs a successful self-calibration.

If an internal fault condition is detected then only the Fault/A-M relay operates. However in an Anti-Mask conditions both the Fault/A-M relay AND the Alarm relay will operate. In this latter condition the small red LED will illuminate.

Self-calibration takes place every evening during decreasing ambient light and every morning during increasing light. This compensates for natural build up of dirt on the front cover; which could otherwise cause a false Fault/Anti-Mask detection.

After a Fault/Anti-Mask alarm and the mask is removed, the Fault/Anti-Mask alarm contact will close. Then after a further 20 seconds the next detection will initiate a self-calibration.

Voltage Check

The unit self-tests the supply voltage and if out of specification the Fault/Anti-Mask relay will open until the supply voltage is within specification.

Remote LED Operation

The LEDs will enable when a negative is applied to the LED terminal.

Remote Self-Test

A self-test routine will commence when a negative is applied to the TEST terminal. The Anti-Mask detector constantly self-checks and will operate the Fault/A-M relay if an internal fault condition is detected.

Accessories

UTC Fire & Security can provide a hand held walk tester DI601 WT to aid installations.

Specifications

Detection range Programmable: 10 m, 20 m or 30 m

Coverage 10 to 70° detection angle, 30 x 24 m coverage max.

Adjustment -60° to +60° pan, tilt +45°

Fresnel lens 28 zones for each detection element, which can be masked with the curtain sliders

Customized optics Double silicon shielded quad element eliminates 50,000 Lux of white light

LEDs

Top PCB

Sensor PCB

Red: Programming LED

Blue: Detector alarm

Red(small): Anti-mask alarm

Infrared: Walk tester communication

Red: PIR active

Green: Microwave active

Microwave module

DDI602AM-F1DDI602AM-F2DDI602AM-F3

Operating frequency (country specific)

10.525 GHz10.587 GHz9.9 GHz

Outputs

NO

NC

Silent, solid state, magnetically immune.

Volt free relay, signal contact 24 VAC/DC at 50 mA with an integral 25 Ω series resistor.Alarm time 5 seconds.

Volt free relay, signal contact 24 VAC/DC at 50 mA with an integral 25 Ω series resistor.Alarm time 5 seconds.

Fault/Mask Volt free relay, signal contact 24 VAC/DC at 50 mA with an integral 25 Ω series resistor

Power input 10 to 15 V DC

Current 21 mA (12 V nominal) Standby 41mA MAX

Pulse count 1 or 2

Temperature compensation

Analogue (thermistor) and digital sensitivity adjustment

Control Digital microprocessor with non-volatile memory

Walk test Output test mode with LED indication. Option to disable LEDs.

Operating temperature −30 to +65°C

Housing High impact ABS plastic with HDPE cover, UV stabilized

Dimensions W x H x D 125 x 175 x 130 mm

Weight 365 g Net, 551 g Gross

Mounting height Variable up to 6 m Optimum height 3 m for full range

Regulatory information

Manufacturer UTC Fire & Security Americas Corporation, Inc.1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA Authorized EU manufacturing representative:UTC Fire & Security B.V.Kelvinstraat 7, 6003 DH Weert, Netherlands

Certification

EN 50130EN 50131

EN50130-5EN50131-2-4, Grade 3, Class IVCertified by Telefication B.VNote: EN50131-2-4 compliant only when mounted at 1.5 and 3m

Environmental class IP65This product meets the environmental requirements of EN50130-5.

European Union directives

1999/5/EC (R&TTE directive): Hereby, UTC Fire & Security declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.

2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.

Usage Restriction

DDI602-F1 (10.525 GHz)

DDI602-F2(10.587 GHz)

DDI602-F3(9.9 GHz)

Only use the listed models in the following countries:

Albania, Argentina, Australia, Belgium, Brazil, Denmark, Holland, Hungary, Iceland, Indonesia, Latvia, Lithuania, Malta, Norway, Portugal, Russia, South Africa, Spain, Taiwan, Ukraine, USA.

Greece, Italy, Thailand, UAE, UK

Austria, Czech Republic, Germany, France, Poland

Contact informationwww.utcfireandsecurity.com or www.interlogix.com.For customer support, see www.interlogix.com/customer-support.