dc/dc converters for railway applicationspictures.attention-ngn.com/files/1346312960.3992.pdf ·...

Download DC/DC Converters for Railway Applicationspictures.attention-ngn.com/files/1346312960.3992.pdf · DIN, Wall, chassis and 19”-rack • Convection cooled with operating temperature

If you can't read please download the document

Upload: truongduong

Post on 07-Feb-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • DC/DC Convertersfor

    Railway Applications

    DC/DC Convertersfor

    Railway Applications

  • Polyamp has continuously supplied switch modeDC/DC converters to the international railwayindustry since 1973. The Company now has thecapability to meet performance requirements ofworldwide applications and to accommodate theextreme environmental demands of hot and humidBangkok, hot and dry Australia and the arctic northof Sweden

    All Polyamp DC/DC Converters for railwayapplications are designed to be safe, technicallycompliant, reliable and cost effective.Applications include systems for surface andunderground trains powered by both electric and diesellocomotives, trams and special vehicles used by theoperators and maintainers. Systems can be categorisedas:Train systemsSystems used by the driver are specifically safetyconscious and a fault will either stop the train orautomatically revert it to an alternative fail safe mode.

    Driver computer Train control Remote control Emergency starting Radio Head and backlight (Xenon/Halogen/LED) Alarm (bells/horns) Wipe washers Cameras

    Passenger comfort systems Displays & information Lamps (Halogen/LED) IT-equipments Sound/Communication Toilets Coffee & Restaurant

    Railway operating systems Counting devices, ticketing Remote control Cameras Doors Lifts including disabled facilities

    Technical StandardsModern trains achieve savings of weight and space byusing battery voltage up to 110Vd.c. but most systemequipments require input power at 12V and 24Vdc.The DC/DC Converter transforms the basic 110Vdcto 12 and 24Vdc, but can also perform the inverse ifnecessary. i.e. convert 12 and 24Vdc to 110Vdc.

    Train standardsPolyamp DC/DC Converters are designed to meet therailway specific standards for electronic equipmentonboard trains including those specified in EN50155and IEC60571. They are mechanically rugged forreliable operation in a very harsh environmentthroughout their whole lifeWhere these standards specify different levels forparticular conditions, applicable ratings will beconfirmed and agreed for individual customerapplications.An additional benefit of the Polyamp DC/DCConverters is that when they are used as a power sourcefor equipments, that in themselves are not compliantwith the EN50155 and IEC60571 standards, theyeffectively function as a filter and galvanic separationto shield those equipments. This allows the railwayoperator to use Commercial Off The Shelf (COTS)equipments for such applications.

    Environmental specification

    Ambient temperatureThe standard level is -25 to +55C but mostapplications specify -25 to +70C (T3).Polyamp DC/DC Converters can be supplied to operatein temperatures from -40C to +85C.EMCCompliant with the EN50121-3-2 and IEC62236-3-2EMC performance specified for electronic equipments.Shock and vibrationCompliant with the IEC/EN61373 requirements forbody mounted class B.Polyamp DC/DC converters are regularly used inmilitary vehicles and fork lifts, which have more severevibration requirements

    Range of DC/DC ConvertersEN50155 and IEC60571 specify a nominal inputvariation of 30% including ripple but some otherspecifications define 40%. For modern trains withbetter d.c. supply systems they can be relaxed and formarkets still using RIA12 specifications, Polyamp canalso supply models that meet its surge requirement of3.5x nominal input voltage.

    System Applications

    DC/DC Converters for Railway Applications

  • Familycode 5 -10 12 15 18 24 28 36 48 60 110 125 V

    PM250

    Single outputs 3 to 125V 2 or 3 outputs 5 to 60V Inputs 10V up to 600V Sturdy mechanics, meets mobile requirements. Easy robust mounting:

    DIN, Wall, chassis and 19-rack Convection cooled with operating temperature range

    -25 to +55C, some models +70C Tropical coating standard or optional High efficiency Safety compliant with EN60950 MTBF >300000h @+40C Useful life >20 years

    PU300/PU500

    PSC400, PSC600, PSC800

    PU600/PU1000

    PM50/PM80

    PSC50 - 240

    PE60

    Relevant experienceWith more than 40 years experience in developingand production of DC/DC Converters Polyamp hasestablished a reputation for quality, reliability and ontime deliveries. Polyamp DC/DC Converters havebeen used in a wide range of applications:

    Forklifts Electrical Vehicles Trains and Track Side Process Control

    Power Plants (including nuclear) Power / DC Distribution Telecom Radiocom

    Industry Naval Air Traffic Control Military Radio applications

    Train logisticsPolyamps experience of successfully completingdeliveries into the train industry include:

    New trains Adding a feature to a fleet Track side equipments Train refurbishments Special equipments

    These markets do not need large bulk quantities andPolyamp has a proven record, which is recognisedby its customers, of delivering not only within timebut on the agreed date.

    The number one choice in DC/DC Converters

    PM50PM80PSE50PE60PSE100PM150PSC150PSC240PM240PSC250PSE250PM250PU300PSC400PU500PU600PSC600PSC800PU1000PC1000PC1400PC2000

    50W80W50W96W

    100W150W150W240W240W250W250W250W300W400W500W600W600W800W1000W1000W1400W2000W

    PC1000, PC1400, PC2000

    10 - 27018 - 30010 - 27014 - 15510 - 27010 - 27010 - 50018 - 55018 - 30018 - 27020 - 27011 - 30010 - 27018 - 27018 - 30018 - 27018 - 27018 - 27018 - 60016 - 30033 - 30033 - 300

    Output Voltage Output InputPower Voltage

    PSE50 - 250

    PM150/PM240

    Key Features

  • Distributor

    [email protected] Polyamp Sales Offices

    Polyamp AB TelephoneBox 229 +46 120 854 10SE-597 25 tvidaberg TelefaxSweden +46 120 854 05

    Head office

    Switch Craft S.A. TelephoneRue Bel Air 63 +41 32 96 78800CH-2300 La Chaux-de-Fonds TelefaxSwitzerland +41 32 96 78809

    Polyamp AB TelefonBox 925 +46 8 594 693 00SE-191 29 Sollentuna TelefaxSweden +46 8 594 693 05

    Polyamp is a privately owned business located in Sollentuna, Stockholm, Sweden, withproduction facilities in Sweden in tvidaberg some 240km south of Stockholm and in

    Switzerland in La Chaux-de-Fonds.Established for over 40 years, the Company has developed from a National Contractor to

    its present status of an International Supplier of high quality Power Electronicequipment.

    The Company

    Polyamp AB TelephoneBox 229 +46 120 854 10SE-597 25 tvidaberg TelefaxSweden +46 120 854 05

    Switch Craft S.A. TelephoneRue Bel Air 63 +41 32 96 78800CH-2300 La Chaux-de-Fonds TelefaxSwitzerland +41 32 96 78809

    Polyamp Sales Offices

    [email protected]

    Head office

    The CompanyPolyamp is a privately owned business located in Sollentuna, Stockholm, Sweden, withproduction facilities in Sweden in tvidaberg some 240km south of Stockholm and in

    Switzerland in La Chaux-de-Fonds.Established for over 40 years, the Company has developed from a National Contractor to

    its present status of an International Supplier of high quality Power Electronicequipment.

    Polyamp AB TelefonBox 925 +46 8 594 693 00SE-191 29 Sollentuna TelefaxSweden +46 8 594 693 05

    /ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 150 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages false /GrayImageDownsampleType /Average /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages false /GrayImageFilter /DCTEncode /AutoFilterGrayImages false /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages false /MonoImageDownsampleType /Average /MonoImageResolution 300 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages false /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects true /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName (http://www.color.org) /PDFXTrapped /False

    /Description >>> setdistillerparams> setpagedevice