dayton electric mfg co. typical performance …1 14.9% 1151% 115.5% 114.8% 115 3450 code ins cl: 56h...

7
Model No:5K961BB Curve at 230 Volts , 60Hz, 2 HP,3450 RPM, 115/208-230V, 60Hz, 1 Phase Customer: WWG Document5K961BB-PC Full load torque 48.7 Oz-ft Full load Amps 18.0/10.0-9.0 Amps BD Torque 130 Oz-ft PU Torque 111 Oz-ft LR Torque 108 Oz-ft LR Amps@230V 60.2 Amps Winding WTS080186P1 Prepared By Viswanath 4/3/2008 DAYTON Electric Mfg Co. Typical Performance Curve for AC motor PLOT FOR WATTS INPUT 0 2000 4000 6000 8000 10000 12000 0 500 1000 1500 2000 2500 3000 3500 4000 Speed (rpm) Input (Watts) PLOT FOR EFFECIENCY 0 10 20 30 40 50 60 70 80 90 0 500 1000 1500 2000 2500 3000 3500 4000 Speed (rpm) Effeciency (%) PLOT FOR TORQUE 0 20 40 60 80 100 120 140 0 500 1000 1500 2000 2500 3000 3500 4000 Speed (rpm) Torque (Oz-ft) PLOT FOR LINE CURRENT 0 10 20 30 40 50 60 70 0 500 1000 1500 2000 2500 3000 3500 4000 Speed (rpm) Line Current (Amps)

Upload: others

Post on 16-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410

Model No:5K961BB Curve at 230 Volts , 60Hz, 2 HP,3450 RPM, 115/208-230V, 60Hz, 1 Phase Customer: WWG Document5K961BB-PC

Full load torque 48.7 Oz-ft Full load Amps 18.0/10.0-9.0 Amps

BD Torque 130 Oz-ft PU Torque 111 Oz-ft

LR Torque 108 Oz-ft LR Amps@230V 60.2 Amps

Winding SpecWTS080186P1 Prepared By Viswanath 4/3/2008

DAYTON Electric Mfg Co.

Typical Performance Curve for AC motor

PLOT FOR WATTS INPUT

0

2000

4000

6000

8000

10000

12000

0 500 1000 1500 2000 2500 3000 3500 4000

Speed (rpm)

Inp

ut

(Watt

s)

PLOT FOR EFFECIENCY

0

10

20

30

40

50

60

70

80

90

0 500 1000 1500 2000 2500 3000 3500 4000

Speed (rpm)

Eff

ecie

ncy (

%)

PLOT FOR TORQUE

0

20

40

60

80

100

120

140

0 500 1000 1500 2000 2500 3000 3500 4000

Speed (rpm)

To

rqu

e (

Oz-f

t)

PLOT FOR LINE CURRENT

0

10

20

30

40

50

60

70

0 500 1000 1500 2000 2500 3000 3500 4000

Speed (rpm)

Lin

e C

urr

en

t (A

mp

s)

Page 2: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410
Page 3: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410
Page 4: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410
Page 5: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410
Page 6: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410
Page 7: DAYTON Electric Mfg Co. Typical Performance …1 14.9% 1151% 115.5% 114.8% 115 3450 CODE INS CL: 56H B RPM 3594 3572 3550 3525 3495 3488 3482 3475 3461 3454 3450 3447 3440 3425 3410