david taylor located in: city of charlotte / mecklenburg...
TRANSCRIPT
9
1
2
3
4
5
6
7
8
10
11
12
13
14
15
16
M
A
L
L
A
R
D
C
R
E
E
K
R
O
A
D
GO
VE
RN
OR
HU
NT
RO
AD
D
A
V
I
D
T
A
Y
L
O
R
D
R
I
V
E
A
L
E
X
A
N
D
E
R
R
O
A
D
P
R
O
S
P
E
R
I
T
Y
C
H
U
R
C
H
R
O
A
D
I
-
8
5
SITE
Site DataTax Parcels: 04716828, 04715239 & 04715237
Total Acreage: +/- 37.94 Acres (Per GIS)
Location: City of Charlotte
Existing Zoning: RE-1
Proposed Zoning: UR-2 (CD) with 5 year vested rights
Existing Use: Vacant
Proposed Use: Single Family Residential (Attached)
Permitted # of Units: Up to 167 For-Sale Townhome Units
Proposed Density: Not to Exceed +/- 4.40 DU/AC
Maximum Building Height: Forty-five (45) feet
Parking: Shall Satisfy or Exceed UR-2 Minimum Requirements
Private Open Space: Minimum of 400 SF per Unit
Amenitized Open Space: +/- 4.6 Acres (Minimum)
Tree Save: Required: +/- 5.69 Acres (15%) Provided: +/- 5.69 Acres (15%) Minimum
General Notes1. Base information obtained from Mecklenburg County GIS.
2. Stream / Wetland Information is based on "Crescent Tract A Charlotte, North Carolina, CWSProject No. 2017-0378" wetlands report provided by Carolina Wetland Services dated August1, 2017.
SHEET:
PROJECT MANAGER:
PROJECT INFORMATION
DESIGNED BY:
DRAWN BY:
PROJECT NUMBER:
ORIGINAL DATE:
ES
P A
ssociates. Inc.
P.O
. B
ox 7
03
0
Ch
arlo
tte
, N
C 2
82
41
34
75
L
ake
mo
nt B
lvd
.
Fo
rt M
ill, S
C 2
97
08
70
4-5
83
-4
94
9 (N
C)
80
3-8
02
-2
44
0 (S
C)
ww
w.e
sp
asso
cia
te
s.co
m
BYRE
VISI
ONDA
TENO
.
110
/16/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/03/17
ZW
211
/13/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/30/17
ZW
302
/12/18
Revis
ed P
er C
lient
GM
403
/19/18
Revis
ed P
er S
taff
Com
men
tsGM
504
/23/18
Revis
ed P
er S
taff
Com
men
tsGM
MALL
ARD
CREE
K RO
AD S
ITE Ci
ty o
f Cha
rlotte
Matta
my H
omes
Cond
itiona
l Dist
rict R
ezon
ing -
UR-2
(CD)
Conc
eptua
l Site
Plan
- Pe
tition
# 20
17-1
33
1 of 5
MM
AB
ZW
FR21.100
08/23/17
1 INCH = FT.
( IN FEET )
GRAPHIC SCALE
0100'50'
100'200' 400'
100
NORTH
Vicinity MapNot to Scale
NORTH
Legend
Residential Development Area - Building & Parking Envelope
71' Public ROW
56' Public ROW
56' Public ROW Dedication (Connection Constructed by Others)
Private Street (30' Clear Zone)
Proposed Access Location
Proposed Stub Location
Proposed Buffer
INDEX OF SHEETSSHEET NAME ORIGINAL DATE REVISED DATE
1 of 5
SHEET NO.
2 of 5
3 of 5
CONCEPTUAL SITE PLANTECHNICAL DATA SHEET &OPEN SPACE CONCEPTSMASTER PLAN
8/23/2017
8/23/20178/23/2017
Mallard Creek Road Site
Conditional District Rezoning - Petition # 2017-133
Located In:
City of Charlotte / Mecklenburg County, North Carolina
Adjacent Property Owners
PID: Owner: Zoning
1 04715216 RE-1234
04715215 JOE BROWN STRUBE & SARAH STRUBE R-304715245 SARAH ANN LAMBERT & BOBBY RAY R-304715246
5 04715232 LANE C SEAFORD & NANCY S SEAFORD6 04715233 RICHARD E JACOBSON & JINMEI JACOBSON
7 04715234 KENNETH M KYZER & DEBORAH O KYZER R-3
8 04715235 BOBBY NICHOLS & SUSAN MARSHALL
9 0471523610 04715222
11 04716827FOUR RESOURCE SQUARE LLC& CENTRE C/O RAIT FINANCIAL TRUST CIRA
12 0471680113 04715244 % TAX DEPARTMENT MERCK & COMPANY INC.14 04715247 H5 DATA CENTERS-CHARLOTTE DEVELOPMENT LLC
HAROLD A SMITH & MIRIAM SMITH R-3
RE-1
RE-1RE-2RE-2
CALFRED R GULLA & AMY C GULLABRIAN VLADYKA
SUMMIT AVENUE URP LLC
R-3R-3
R-3
R-3R-3
TDCA RESOURCE SQUARE LLC C/O THE DILWEG COMPANIESLLC ATTENTION: JEFFREY A BENSON
15 04713104 SUMMIT AVENUE URP LLC RE-116 04741201 RE-1SUMMIT AVENUE URP LLC
Property Owners
PID: Owner: Zoning04716828 Crescent Communities, LLC RE-104715239 Crescent Communities, LLC RE-104715237 Crescent Communities, LLC RE-1
4 of 5 CONCEPTUAL MASTER PLAN 8/23/20175 of 5 ARCHITECTURAL ELEVATIONS 8/23/2017
04/23/2018
04/23/201804/23/201804/23/201804/23/2018
5
WALKWAY (TYP.)
SIDEWALK (TYP.)
TOWNHOME
(TYP.)
RO
AD
WA
Y
TOWNHOME
(TYP.)
LINEAR
PARK
20' A
LL
EY
LANDSCAPING (TYP.)
CONCEPT A
CONCEPT B
LANDSCAPING (TYP.)
R
O
A
D
W
A
Y
TOWNHOME
(TYP.)
PARK
U
:\2
01
7 P
ro
je
cts (F
)\F
R2
1-M
alla
rd
C
re
ek (M
atta
my)\S
ub
mitta
l W
orkin
g D
ra
win
gs\2
01
8-0
4-2
0_
Re
zo
nin
g 6
th
S
ub
mitta
l\D
WG
\S
he
ets\F
R2
1 - M
alla
rd
C
re
ek R
oa
d - T
ech
nica
l D
ata
S
he
et.d
wg
, S
he
et 2
o
f 5
, g
mu
se
SHEET:
PROJECT MANAGER:
PROJECT INFORMATION
DESIGNED BY:
DRAWN BY:
PROJECT NUMBER:
ORIGINAL DATE:
ES
P A
ssociates Inc.
P.O
. B
ox 7
03
0
Ch
arlo
tte
, N
C 2
82
41
34
75
L
ake
mo
nt B
lvd
.
Fo
rt M
ill, S
C 2
97
08
70
4-5
83
-4
94
9 (N
C)
80
3-8
02
-2
44
0 (S
C)
ww
w.e
sp
asso
cia
te
s.co
m
BYRE
VISI
ONDA
TENO
.
110
/16/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/03/17
ZW
211
/13/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/30/17
GM
302
/12/18
Revis
ed P
er C
lient
GM
403
/19/18
Revis
ed P
er S
taff
Com
men
tsGM
504
/23/18
Revis
ed P
er S
taff
Com
men
tsGM
MALL
ARD
CREE
K RO
AD S
ITE Ci
ty o
f Cha
rlotte
Matta
my H
omes
Cond
itiona
l Dist
rict R
ezon
ing -
UR-2
(CD)
Tech
nical
Data
Shee
t & O
pen S
pace
Con
cepts
-Pe
tition
# 20
17-1
33
2 of 5
MM
AB
ZW
FR21.100
08/23/2017
Mallard Creek Road Site - Petition #2017-133Conditional District Rezoning - Development Standards
LOCATION MAPNOT TO SCALE
CONCEPT ALinear Park Concept
CONCEPT BPocket Park Concept
NORTH
Open Space Locations and ConceptsNot to Scale
I. General Provisions
1. These Development Standards form a part of the Rezoning Plan associated with the Rezoning Petition
filed by Mattamy Homes (the “Petitioner”) to accommodate the development of a residential community
on that approximately 37.94 acre site located on the south-west side of College View Lane and north of
Governor Hunt Road, more particularly depicted on the Rezoning Plan (the “Site”). The Site is comprised
of Tax Parcel Numbers 047-168-28, 047-152-39, and 047-152-37.
2. Development of the Site will be governed by the Rezoning Plan, these Development Standards and the
applicable provisions of the City of Charlotte Zoning Ordinance (the “Ordinance”).
3. Unless the Rezoning Plan or these Development Standards establish more stringent standards, the
regulations established under the Ordinance for the UR-2 zoning district shall govern the development
and use of the Site.
4. The development and street layout depicted on the Rezoning Plan are schematic in nature and are
intended to depict the general arrangement of such uses and improvements on the Site. Accordingly,
the ultimate layout, locations and sizes of the development and site elements depicted on the Rezoning
Plan are graphic representations of the proposed development and site elements, and they may be
altered or modified in accordance with the setback, yard, landscaping and tree save requirements set
forth on this Rezoning Plan and the Development Standards, provided, however, that any such
alterations and modifications shall be minor in nature and not materially change the overall design intent
depicted on the Rezoning Plan.
5. Future amendments to the Rezoning Plan and/or these Development Standards may be applied for by
the then owner(s) of the Site in accordance with the provisions of Chapter 6 of the Ordinance. Minor
alterations to the Rezoning Plan are subject to Section 6.207 of the Ordinance.
II. Permitted Uses
The Site may be devoted only to a residential community containing a maximum of 167 single-family
attached dwelling units and any incidental and accessory uses relating thereto that are allowed in the
UR-2 zoning district.
III. Transportation
1. Vehicular access will be as generally depicted on the Rezoning Plan. The placements and
configurations of the vehicular access points shown on the Rezoning Plan are subject to any minor
modifications required to accommodate final site and construction plans and designs and to any
adjustments required by CDOT for approval.
2. As depicted on the Rezoning Plan, the Site will be served by internal public and private drives, and minor
adjustments to the locations of the internal private drives shall be allowed during the construction
permitting process.
3. Petitioner shall dedicate all rights-of-way in fee simple conveyance to the City of Charlotte before the
Site's first building certificate of occupancy is issued or phased per the Site's development plan.
Rights-of-way shall be set to at least one (1) foot behind the back of sidewalk, where feasible.
4. A street connection to College View Lane shall not be made until such time as the at least two (2) parcels
immediately west of College View Lane are rezoned to a zoning district other than the current R-3 zoning
district. In order to accommodate that future connection to be constructed by the City or others, the
Petitioner shall design, plat and dedicate the right-of-way to provide for the future connection from the
Site to College View Lane. The right-of-way dedication for the new street to College View Lane will be
dedicated at the time the street is constructed.
5. Petitioner shall substantially complete all transportation improvements before the Site's first building
certificate of occupancy is issued.
a. Substantial completion shall mean completion of the roadway improvements in accordance with the
standards set forth herein provided, however, in the event certain non-essential roadway
improvements (as reasonably determined by CDOT) are not completed at the time that the Petitioner
seeks to obtain a certificate of occupancy for building(s) on the Site in connection with related
development phasing described above, then CDOT will instruct applicable authorities to allow the
issuance of certificates of occupancy for the applicable buildings, and in such event the Petitioner
may be asked to post a letter of credit or a bond for any improvements not in place at the time such a
certificate of occupancy is issued to secure completion of the applicable improvements.
IV. Architectural Standards
1. To provide privacy, all residential entrances within fifteen (15) feet of a sidewalk shall be raised from the
average sidewalk grade a minimum of twenty-four (24) inches.
2. Pitched roofs, if provided, may be of a contemporary style with asymmetrical low roof slopes of no less
than 4:12, with the exception of flat roof accents or parapets, which may be provided in strategic
locations.
3. Usable porches or stoops shall form a predominant feature of the building design and be located on the
front and/or side of the building. Stoops and entry-level porches may be covered but shall not be
enclosed.
4. For all corner/end units that face a public or private street, stoops shall face the public realm and corner
units will have enhanced side elevations with a front stoop.
5. Garage doors will be recessed behind a balcony or building projection so that a minimum of two (2) feet
of the driveway will be covered by a balcony or building projection to mitigate the appearance of the
garage.
6. For townhome units that are alley-loaded, walkways shall be provided to connect all residential entrances
to sidewalks along public and private streets. For townhome units that are front-loaded, the walkways
shall lead to the driveway in order to ensure landscaping treatment in between driveway entrances.
7. Attached dwelling units shall be limited to a maximum of five (5) townhome units per building.
8. Roof overhangs, eaves, cornices, chimneys, gutters, vents, bay windows, pilasters, pillars, open porches
(if provided), and other architectural elements may project up to twenty-four (24) inches into the required
setbacks.
9. Refuse collection throughout the Site shall be in the form of roll-out containers, however, in the event that
roll-out containers are not utilized, the Site shall be serviced by dumpsters in the proposed locations as
shown on the Rezoning Plan.
V. Streetscape and Landscaping
1. The Petitioner shall provide a minimum eight (8) foot wide planting strip and a minimum six (6) foot wide
sidewalk along both sides of all proposed public and private streets. A minimum eight (8) foot wide
planting strip and a minimum six (6) foot wide sidewalk shall be provided along both sides of all proposed
private streets.
2. The Petitioner may subdivide the Site and create lots within the Site with no side or rear yards as part of
a unified development plan.
3. Petitioner shall provide a minimum setback of at least twenty (20) feet from the proposed back of curb for
front-loaded units fronting public and private streets, a minimum setback of twenty (20) feet from the
proposed back of curb for alley-loaded units fronting public streets, and a minimum setback of fourteen
(14) feet from the proposed back of curb for alley-loaded units fronting private streets. Stoops and stairs
may encroach three (3) feet into the setback as a “transition zone.”
4. For alley loaded units, driveway lengths shall be a minimum of 5-7' or 20' and greater measured from the
back of curb to face of garage.
5. For front loaded units, driveway lengths shall be a minimum of 20' measured from the back of sidewalk to
face of garage.
VI. Environmental Features
1. The Petitioner shall comply with the Charlotte City Council approved and adopted Post Construction
Stormwater Ordinance. The location, size, and type of stormwater management systems depicted on
the Rezoning Plan are subject to review and approval as part of the full development plan submittal and
are not implicitly approved with this rezoning. Adjustments may be necessary in order to accommodate
actual storm water treatment requirements and natural site discharge points.
VII. Open Space
1. The Petitioner shall comply with tree save requirements.
2. The Petitioner shall provide a minimum of 4.6 acres of common open space areas within the Site, as
generally depicted on the Rezoning Plan, to include amenitized areas which may contain, but not be
limited to, decorative features, landscaping, benches, garden artwork, and/or walking paths.
VIII. Lighting
1. All freestanding lighting fixtures installed on the Site (excluding lower, decorative lighting that may be
installed along the driveways and sidewalks as landscaping lighting) shall be fully capped and shielded
and the illumination downwardly directed so that direct illumination does not extend past any property line
of the Site.
2. The maximum height of any pedestrian scale, freestanding lighting fixture installed on the Site, including
its base, shall not exceed twenty-one (21) feet.
3. Any lighting fixtures attached to the buildings to be constructed on the site shall be decorative, capped
and downwardly directed.
IX. Amendments to Rezoning Plan
Future amendments to the Rezoning Plan and these Development Standards may be applied for by the
then Owner or Owners of a particular Tract within the Site involved in accordance with the provisions of
Chapter 6 of the Ordinance.
X. Binding Effect of the Rezoning Documents and Definitions
If this Rezoning Petition is approved, all conditions applicable to development of the Site imposed under
the Rezoning Plan and these Development Standards will, unless amended in the manner provided
under the Ordinance, be binding upon and inure to the benefit of the Petitioner and subsequent owners
of the Site and their respective successors in interest and assigns.
Throughout these Development Standards, the terms, “Petitioner” and “Owner” or “Owners” shall be
deemed to include the heirs, devisees, personal representatives, successors in interest and assigns of
the Petitioner or the owner or owners of any part of the Site from time to time who may be involved in any
future development thereof.
5
STREAM (PER REPORT)
5
0
'
C
L
A
S
S
A
B
U
F
F
E
R
50' C
LA
SS
A
B
UF
FE
R
5
0
'
C
L
A
S
S
A
B
U
F
F
E
R
3
0
'
R
E
V
E
R
S
E
F
R
O
N
T
A
G
E
B
U
F
F
E
R
5
0
'
C
L
A
S
S
C
B
U
F
F
E
R
PROPOSED WATER
QUALITY
PROPOSED
WATER QUALITY
PROPOSED
TREE SAVE
PROPOSED
TREE SAVE
PROPOSED ROW FOR
FUTURE CONNECTION
BY OTHERS.
PROPOSED
TREE SAVE
EXISTING POND
(PER REPORT)
PR
OP
ER
TY
L
IN
E (T
YP
.)
PR
OP
ER
TY
LIN
E (T
YP
.)
P
R
O
P
E
R
T
Y
L
I
N
E
(
T
Y
P
.
)
P
R
O
P
E
R
T
Y
L
I
N
E
(
T
Y
P
.
)
P
R
O
P
E
R
T
Y
L
IN
E
(T
Y
P
.)
PR
OP
. 56' L
OC
AL
RE
S. M
ED
.
20' A
LL
EY
(T
YP
.)
2
0
'
A
L
L
E
Y
(
T
Y
P
.
)
P
R
O
P
.
7
1
'
L
O
C
A
L
R
E
S
.
W
I
D
E
PR
OP
. P
RIV
AT
E S
TR
EE
T (T
YP
.)
20' A
LL
EY
(T
YP
.)
P
R
O
P
.
5
6
'
L
O
C
A
L
R
E
S
.
M
E
D
.
50' C
LA
SS
A
B
UF
FE
R
RE-1
RESEARCH
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
R-3
SINGLE FAMILY
DETACHED
9
R-3
SINGLE FAMILY
DETACHED
RE-1
RESEARCH
RE-1
RESEARCH
RE-2
RESEARCH
RE-2
RESEARCH
RE-1
RESEARCH
RE-1
RESEARCH
1
2
3
4
5
6
7
8
10
11
12
13
14
15
16
GO
VE
RN
OR
HU
NT
RO
AD
C
O
L
L
E
G
E
V
I
E
W
L
A
N
E
100' UNDISTURBED
PCSO BUFFER (PER GIS)
PROPOSED
TREE SAVE
PROPOSED
TREE SAVE
ACCESS "B"
PROP. STUB STREET
(56' LOCAL RESIDENTIAL
MEDIUM)
ACCESS "A"
PROP. STUB STREET
(56' LOCAL RESIDENTIAL
MEDIUM)
WETLAND (PER
REPORT)
PR
OP
. 71' L
OC
AL
R
ES
. W
ID
E
P
R
O
P
.
7
1
'
L
O
C
A
L
R
E
S
.
W
I
D
E
P
R
O
P
.
5
6
'
L
O
C
A
L
R
E
S
.
M
E
D
.
PR
OP
. 56' L
OC
AL
RE
S. M
ED
.
P
R
O
P
.
P
R
I
V
A
T
E
S
T
R
E
E
T
(
T
Y
P
.
)
2
0
'
A
L
L
E
Y
(
T
Y
P
.
)
100' B
UF
FE
R(PE
R U
NIV
ER
SIT
Y R
ES
EA
RC
H P
AR
K
CH
AR
LO
TT
E A
RE
A P
LA
N)
50' UNDISTURBED
PCSO BUFFER
(PER GIS)
APPROX. LOCATION OF FUTURE GOVERNOR HUNT ROAD B.O.C.
TO ACCOMMODATE TWO LAND DIVIDED AVE. WITH BUFFERED
BIKE LANES (BY OTHERS).
(29.5' FROM EXISTING CENTERLINE OF GOVERNOR HUNT ROAD.)
6' SIDEWALK AT GOVERNOR HUNT ROAD STREET FRONTAGE.
EXACT LOCATION / ALIGNMENT TO BE DETERMINED DURING
CONSTRUCTION DOCUMENT PHASE
LINEAR
PARK
+/- 0.5 ACRES
LINEAR PARK
+/- 0.4 ACRE
TRAIL / WATER
QUALITY AREA
+/- 3 ACRES
PEDESTRIAN TRAIL
GUEST
PARKING
PROPOSED
TREE SAVE
ROW DEDICATED FOR
FUTURE COLLEGE VIEW
LANE EXTENSION
LINEAR
PARK
+/- 0.1 ACRE
WETLAND (PER
REPORT)
ON-STREET
PARKING (TYP.)
LINEAR PARK
+/- 0.1 ACRE
PROPOSED
TREE SAVE
Common Open
Space (typ.)
POCKET PARK
+/- .1 ACRE
Potential Amenity
Area
15' PAVEMENT , 6' SIDEWALK, 8'
PLANTING STRIP, & CURB AND
GUTTER AT COLLEGE VIEW LANE
STREET FRONTAGE TO
ACCOMMODATE LOCAL RESIDENTIAL
WIDE STREET SECTION
PROP. STUB
STREET
PROP. TRASH RECYCLING
COLLECTION STATION
(TYP.)
PROP. TRASH RECYCLING
COLLECTION STATION
(TYP.)
PROP. TRASH RECYCLING
COLLECTION STATION
(TYP.)
PR
OP
. P
RIV
AT
E S
TR
EE
T (T
YP
.)
APPROXIMATE CENTERLINE OF
EX. PAVEMENT (PER GIS)
1. FOR EXPLANATION OF RIGHT-OF-WAY
WIDTHS REFER TO CITY OF CHARLOTTE
SUBDIVISION ORDINANCE SECTION
20-22(d).
2. ZONING SETBACKS MEASURED FROM
TOTAL R/W
NOTE:
NOT TO SCALE
RESIDENTIAL ALLEY DETAIL
DOUBLE LOADED W/ TWO-WAY OPERATION
11.19B
PLAN
16'
2'-0" VALLEY GUTTER OR
1'-0" CONCRETE STRIP
2
%
2
%
1.5" SF-9.5A
OR I-2
6"
CABC
NOTES:
SUBGRADE SHALL BE COMPACTED TO PUBLIC STREET STANDARDS.
STORM DRAINAGE (NOT SHOWN) SHALL BE PROVIDED AS NECESSARY.
ALLEYS SHALL BE CONSIDERED PRIVATE EASEMENTS AND WILL NOT BE
ACCEPTED FOR MAINTENANCE BY THE CITY OF CHARLOTTE.
COMPACTED
SUBGRADE
2'-0"
VALLEY
GUTTER
(TYP.)
ALLEY WITH NORMAL CROWN
2
%
2
%
ALLEY WITH INVERSE CROWN
0.5
%0.5
%
COMPACTED SUBGRADE
1.5" SF-9.5A OR I-2
6"
CABC
1'-0"
CONCRETE
STRIP (TYP.)
30' MIN. TO
REAR INTERIOR WALL
30' MIN. TO REAR
OF PARKING PAD
PARKING PAD
GARAGE
(OPTIONAL)
D3*
1.
2.
3.
4.
10' MIN.
5' MIN.
D4*
10
PARKING PAD*
* WITH NO PARKING PAD, DIMENSION D3 IS REQUIRED TO BE MINIMUM 5'
BUT NO GREATER THAN 7'. WITH PARKING PAD, DIMENSION D4 IS
REQUIRED TO BE A MINIMUM OF 20'.
24' Townhomes- Front Load
* 20' Minimum Setback from Face of Unit to Back
of Curb (Public or Private)
** 20' Minimum from Face of Garage to Back of
Sidewalk
Public ROW /
Private Street
(30' Clear Zone)
2nd Floor Over Driveway
20.00'*
20.00'** Driveway
24' Townhomes- Alley Load
20' Alley
20.00'
20.00'
* 20' Minimum Setback from Face of Unit to Back
of Curb (Public)
** 14' Minimum Setback from Face of Unit to Back
of Curb (Private)
*** 5' Minimum Setback from Alley Back of Curb
Face of Garage
Public ROW /
Private Street
(30' Clear Zone)
2nd Floor Over
Driveway
Driveway
Face of Garage
6' Sidewalk
8' Planter
6' Sidewalk
8' Planter
Note:400 SF Minimum Private
Open Space Per Unit Required.
5.00'***
M
A
L
L
A
R
D
C
R
E
E
K
R
O
A
D
GO
VE
RN
OR
HU
NT
RO
AD
D
A
V
I
D
T
A
Y
L
O
R
D
R
I
V
E
A
L
E
X
A
N
D
E
R
R
O
A
D
P
R
O
S
P
E
R
I
T
Y
C
H
U
R
C
H
R
O
A
D
I
-
8
5
SITE
Site DataTax Parcels: 04716828, 04715239 & 04715237
Total Acreage: +/- 37.94 Acres (Per GIS)
Location: City of Charlotte
Existing Zoning: RE-1
Proposed Zoning: UR-2 (CD) with 5 year vested rights
Existing Use: Vacant
Proposed Use: Single Family Residential (Attached)
Permitted # of Units: Up to 167 For-Sale Townhome Units
Proposed Density: Not to Exceed +/- 4.40 DU/AC
Maximum Building Height: Forty-five (45) feet
Parking: Shall Satisfy or Exceed UR-2 Minimum Requirements
Private Open Space: Minimum of 400 SF per Unit
Amenitized Open Space: +/- 4.6 Acres (Minimum)
Tree Save: Required: +/- 5.69 Acres (15%) Provided: +/- 5.69 Acres (15%) Minimum
General Notes1. Base information obtained from Mecklenburg County GIS.
2. Stream / Wetland Information is based on "Crescent Tract A Charlotte, North Carolina, CWSProject No. 2017-0378" wetlands report provided by Carolina Wetland Services dated August1, 2017.
SHEET:
PROJECT MANAGER:
PROJECT INFORMATION
DESIGNED BY:
DRAWN BY:
PROJECT NUMBER:
ORIGINAL DATE:
ES
P A
ssociates Inc.
P.O
. B
ox 7
03
0
Ch
arlo
tte
, N
C 2
82
41
34
75
L
ake
mo
nt B
lvd
.
Fo
rt M
ill, S
C 2
97
08
70
4-5
83
-4
94
9 (N
C)
80
3-8
02
-2
44
0 (S
C)
ww
w.e
sp
asso
cia
te
s.co
m
BYRE
VISI
ONDA
TENO
.
110
/16/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/03/17
ZW
211
/13/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/30/17
ZW
302
/12/18
Revis
ed P
er C
lient
ZW
403
/19/18
Revis
ed P
er S
taff
Com
men
tsGM
504
/23/18
Revis
ed P
er S
taff
Com
men
tsGM
MALL
ARD
CREE
K RO
AD S
ITE Ci
ty o
f Cha
rlotte
Matta
my H
omes
Cond
itiona
l Dist
rict R
ezon
ing -
UR-2
(CD)
Maste
r Plan
- Pe
tition
# 20
17-1
33
3 of 5
MM
AB
ZW
FR21.100
08/23/2017
1 INCH = FT.
( IN FEET )
GRAPHIC SCALE
0100' 50' 100' 200' 400'
100
NORTH
Vicinity MapNot to Scale
NORTH
Typical Unit DetailsNot to Scale
Typical Street Sections & Land Development StandardsNot to Scale
1
5
.
0
0
'
5
55
M
A
L
L
A
R
D
C
R
E
E
K
R
O
A
D
GO
VE
RN
OR
HU
NT
RO
AD
D
A
V
I
D
T
A
Y
L
O
R
D
R
I
V
E
A
L
E
X
A
N
D
E
R
R
O
A
D
P
R
O
S
P
E
R
I
T
Y
C
H
U
R
C
H
R
O
A
D
I
-
8
5
SITE
SHEET:
PROJECT MANAGER:
PROJECT INFORMATION
DESIGNED BY:
DRAWN BY:
PROJECT NUMBER:
ORIGINAL DATE:
ES
P A
ssociates Inc.
P.O
. B
ox 7
03
0
Ch
arlo
tte
, N
C 2
82
41
34
75
L
ake
mo
nt B
lvd
.
Fo
rt M
ill, S
C 2
97
08
70
4-5
83
-4
94
9 (N
C)
80
3-8
02
-2
44
0 (S
C)
ww
w.e
sp
asso
cia
te
s.co
m
BYRE
VISI
ONDA
TENO
.
110
/16/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/03/17
ZW
211
/13/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/30/17
GM
302
/12/18
Revis
ed P
er C
lient
GM
403
/16/18
Revis
ed P
er S
taff
Com
men
tsGM
504
/23/18
Revis
ed P
er S
taff
Com
men
tsGM
MALL
ARD
CREE
K RO
AD S
ITE Ci
ty o
f Cha
rlotte
Matta
my H
omes
Cond
itiona
l Dist
rict R
ezon
ing -
UR-2
(CD)
Conc
eptua
l Mas
ter P
lan -
Petiti
on #
2017
-133
4 of 5
MM
AB
ZW
FR21.100
08/23/17
1 INCH = FT.
( IN FEET )
GRAPHIC SCALE
0100' 50' 100' 200' 400'
100
NORTH
Vicinity MapNot to Scale
NORTH
Conceptual Master Plan
6' SIDEWALK8' PLANTING STRIP
20' DRIVEWAY FROM BACK OF SIDEWALK
20' MINIMUM SETBACK FROM BACK OF CURB
TO FACE OF UNIT
PUBLIC/PRIVATE STREET
20' DRIVEWAY FROM BACK OF CURB 20' ALLEY
6' SIDEWALK8' PLANTING STRIP
3' ENCROACHMENT INTO
"TRANSITION ZONE"
14' MINIMUM SETBACK FROM BACK OF CURB
TO FACE OF UNIT (PRIVATE)
20' MINIMUM SETBACK FROM BACK OF CURB
TO FACE OF UNIT (PUBLIC)
U
:\2
01
7 P
ro
je
cts (F
)\F
R2
1-M
alla
rd
C
re
ek (M
atta
my)\S
ub
mitta
l W
orkin
g D
ra
win
gs\2
01
8-0
4-2
0_
Re
zo
nin
g 6
th
S
ub
mitta
l\D
WG
\S
he
ets\F
R2
1 - M
alla
rd
C
re
ek R
oa
d - A
rch
ite
ctu
re
S
he
et.d
wg
, S
he
et 3
o
f 4
, g
mu
se
SHEET:
PROJECT MANAGER:
PROJECT INFORMATION
DESIGNED BY:
DRAWN BY:
PROJECT NUMBER:
ORIGINAL DATE:
ES
P A
ssociates. Inc.
P.O
. B
ox 7
03
0
Ch
arlo
tte
, N
C 2
82
41
34
75
L
ake
mo
nt B
lvd
.
Fo
rt M
ill, S
C 2
97
08
70
4-5
83
-4
94
9 (N
C)
80
3-8
02
-2
44
0 (S
C)
ww
w.e
sp
asso
cia
te
s.co
m
BYRE
VISI
ONDA
TENO
.
110
/16/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/03/17
ZW
211
/13/17
Revis
ed P
er S
taff
Com
men
ts R
eceiv
ed 10
/30/17
ZW
302
/12/18
Revis
ed P
er C
lient
GM
403
/19/18
Revis
ed P
er S
taff
Com
men
tsGM
504
/23/18
Revis
ed P
er S
taff
Com
men
tsGM
MALL
ARD
CREE
K RO
AD S
ITE Ci
ty o
f Cha
rlotte
Matta
my H
omes
Cond
itiona
l Dist
rict R
ezon
ing -
UR-2
(CD)
Arch
itectu
ral E
levati
on S
heet
- Peti
tion #
2017
-133
5 of 5
MM
AB
ZW
FR21.100
08/23/2017
Front & Alley Loaded Cross Sections
Front Loaded Cross Section - NTS
Alley Loaded Cross Section - NTS