datasheet - arkonarkon.co.uk/pdf/differential_pressure/difp20/data... · version with explosion...

7
Differential pressure transmitter Technical datasheet

Upload: others

Post on 12-Aug-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

Differential pressure transmitter

Technical datasheet

Page 2: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

2

Advantages The DIFP20 pressure transmitter with HART® interface combines maximum precision with easy operation. It is used to measure the relative and absolute pressures of gases, vapors and liquids. The integrated LCD shows measurements and device data. In the version with “Ex ia (intrinsically safe)“ explosion protection, the pressure transmitter can be fitted up to zone 0.The housing and sensors are made from high-quality stainless steel. Various front-flush process connections are available for applications to meet hygiene requirements, including the EHEDG- certified PEKA connection system. A high-temperature version capable of withstanding medium temperatures up to 200°C has been specifically designed for application involving hot media and pipes. It is also possible to connect remote seals for special process engineering aplications. The transmitter is programmable, making it readily adaptable to a variety of different measurement tasks. A user-friendly setup program is available as an accessory, for operation via the interfaces. A rotary knob ensures highly convenient and fast local, manual operation.

Features

Water & Wastewater - distribution networks, irrigation, sludge/sewage, water treatment, leakage management, desalination, marine, checking of pumps and water wells Public utilities - water supply system, sewage systems, wastewater, industrial water, sludge, human waste etc. Food industry - breweries, dairies Chemical - chemicals, power stations, oil and gas Construction - building material slurry, sediment slurry, industrial water, plant engineering offshore, shipbuilding etc. Hygienic/Sanitary - potable water metering, food & beverages, pharmaceutical, medium and high density fluids, blending, dosing, batching

LCD display - with bar graph, scaling with a choice of measurement unis, dis- play of sensor temperature, minimum and maximum pressures, current sensor functions and more

Process reliability

Parts in contact with the medium are made of stainless steel (alternatively with NiMo alloy, or with a Monel, titanium or PTFE coating when used with a pressure separator). Combined with the front flush system, this offers optimum resistance to even aggressive media. The measuring instrument has a high degree of precision with deviation from characteristic line of 0.05 %, and offers excellent long-term stability of < 0.1 % per year. The version with explosion protection „Ex ia (intrinsically safe)“ allows the pressure transmitter to be installed up to zone 0. The high-temperature version guarantees safe application in SIP and CIP systems.

Applications

Stainless steel housing HART® interface Easy setup program 0.05 % linearity and turn down only 1:50 Unique design - with rotary knob for ease of operation and EX ia expolosion protection against gas and dust

Simple and time-saving

The measuring instrument can be adjusted reliably and easily with a rotary knob on the device or with a convenient setup program.The device is equipped with both a HART interface and the JUMO interface. The rotary knob is operated from the outside without having to open the device.

Flexible

The measuring instrument can be fitted in any installation position for optimum readability, configuration, and electrical installation.Measurement features can be adapted to all major applications (process pressure, filling level) and ambient conditions using the adjustable parameters.

Page 3: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

3

Reference conditions DIN 16086, DIN EN 60770 and DIN IEC 770/5.3

Sensor system Silicon sensor with stainless steel separating diaphragm

Permissible load change > 10 million

Displayed values

Input pressure (mH2O, inH2O, inHg, ftH2O, mmH2O, mmHg, psi, bar, mbar, kg/cm2, kPa, Torr, MPa) Measurement value (% or scaled with a freely adjustable measurement unit) Output current (mA)Sensor temperature (°C; °F)Additional display data (Minimum pressure, maximum pressure, error, overrange, underrange, operating hours, device parameters)

Location

Mounting position (Any)Calibration position (Device standing vertically, process co-nnection on bottom)Location-dependent zero point offset (Zero point calibrati-on possible locally or via setup)For medium temperature 1 (up to 120 °C) <1 mbarFor medium temperature 2 (up to 200 °C) <10 mbar

Display LCD, two-line with bar graph

AlignmentDisplay unit can be rotated 90° at a time Housing can be rotated ±160°

Display size Display field 22 × 35 mm/font size 7 mm/5 digits

Display color Black

Local operation With rotary knob and LCD

Setup program Via interface or for output 410 (4 to 20 mA with HART®)

Voltage supply For version with explosion protection 0 (none) DC 11.5 to 36 V Explosion protection 1 (ATEX Ex ia) DC 11.5 to 28 V The voltage supply must be intrinsically safe and must not exceed the following maximum values: Ui DC 28 V Ii 93 mA Pi 750 mW

OutputFor output 405 4-20 mA, two wire

For output 410 4 to 20 mA, two wire with HART®

Step response time 190 ms without damping

Damping adjustable, 0 to 100 s

For output 405 (4 to 20 mA) Burden (UB-11.5 V) ÷ 0.022 A

For output 410 (4 to 20 mA with HART®)

Burden (UB-11.5 V) ÷ 0.022 A; additional: min. 250 , max. 1100

Technical dataDIFP20

Technical Specifications

Input - Relative pressureNominal measuring range -600 to +600 mbar rel. 1 to +4 bar rel. -1 to +25 bar rel -1 to +100 bar rel -1 to +600 bar rel.

Overload capacity 6 bar 30 bar 150 bar 300 bar 1200 bar

Burst pressure 12 bar 60 bar 250 bar 400 bar 2000 bar

Input - Absolute pressure

Nominal measuring range 0 to 0.6 bar abs. 0 to 4 bar abs. 0 to 25 bar abs 0 to 100 bar abs

Overload capacity 6 bar 30 bar 150 bar 300 bar

Burst pressure 12 bar 60 bar 250 bar 400 bar

Permissible temperatures in operation

Version CategoryMax. medium tempe-rature

Ambient temperatureExtended ambient temperature(extra code 681)

Standard +120 °C -40 to +85 °C -50 to +85 °C

High temperature +200 °C -40 to +85 °C -50 to +85 °C

II 1/2G Ex ia

T6T5T4T3

+60 °C +70 °C+115 °C+175 °C

-40 to +50 °C-40 to +65 °C-40 to +85 °C-40 to +85 °C

-50 to +50 °C-50 to +65 °C-50 to +85 °C-50 to +85 °C

II 1/2D Ex ia T105 °C +100 °C -40 to +60 °C -50 to +60 °C

Permissible temperatures in storage -40 to +85°C

Page 4: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

4

Permissible relative humidityOperation 100 % incl. condensation on instrument outer sleeve Sto-rage 90 % without condensation

Permissible mechanical loadingVibration performance 2 g, 10 to 2000 Hz to DIN EN 60068-2-6 Shock resistance 15 g for 6 ms to IEC 60068-2-27

Electromagnetic compatibility To EN 61326

Interference emission Class B

Interference resistance Industry

ProtectionVersion with explosion protection 0 (none) IP 67 to DIN EN 60529Version with explosion protection 1 (ATEX Ex ia) IP 66 to DIN EN 60529

Relative pressureNominal measuring range -600 to +600 mbar rel. -1 to +4 bar rel. -1 to +25 bar rel -1 to +100 bar rel -1 to +600 bar rel.

Factory setting for measu-ring range

0 to 600 mbar 0 to 4 bar 0 to 25 bar 0 to 100 bar 0 to 600 bar

Minimum span 60 mbar 0.1 bar 0.5 bar 5 bar 30 bar

Turndown ratio (r) r < 20 r < 50 r < 52 r < 20 r < 20

Linearity for linear characte-ristic as % of the set span

0.1 % for r < 10 r × 0.01 % for 10 <r <20

0.05 % for r < 10 r × 0.005 % for 10 <r < 50

0.05 % for r < 10 r × 0.005 % for 10 <r <52

0.05 % for r< 10 r × 0.005 % for 10 < r< 20

Accuracy at 20 °C as % of the set span

0.2 % for r < 10 r × 0.02 % for 10 <r < 20

0.1 % for r < 10 0.1 % for r < 10r × 0.01 % for 10 <r < 52

0.1 % for r < 10r × 0.01 % for 10 <r < 20

Accuracy at -40 to +85 °C as % of the set span

0.3 % for r < 10 r × 0.03 % for 10 < r < 20

0.2 % for r < 10r × 0.02 % for 10 < r < 50

0.2 % for r < 10r × 0.02 % for 10 < r < 52

0.2 % for r < 10r × 0.02 % for 10 < r < 20

Long-term stability as % of nominal measuring range

0.1 %/year

Absolute pressureNominal measuring range 0 to 0.6 bar abs. 0 to 4 bar abs. 0 to 25 bar abs. 0 to 100 bar abs.

Factory setting for measuring range 0 to 600 mbar 0 to 4 bar 0 to 25 bar 0 to 100 bar

Minimum span 60 mbar 0.1 bar 0.5 bar 5 bar

Turndown ratio (r) r < 10 r < 40 r < 50 r < 20

Linearity for linear characteristic as % of the set span

0.1 % for r < 5 r × 0.02 % for 5 <r <10

0.05 % for r < 10 r × 0.005 % for 10 <r < 40

0.05 % for r < 10 r × 0.005 % for 10 <r <50

0.05 % for r< 10 r × 0.005 % for 10 < r< 20

Accuracy at 20 °C as % of the set span0.2 % for r < 5 r × 0.04 % for 5 <r < 10

0.1 % for r < 10r × 0.01 % for 10 <r < 40

0.1 % for r < 10r × 0.01 % for 10 <r < 50

0.1 % for r < 10r × 0.01 % for 10 <r < 20

Accuracy at -40 to +85 °C as % of the set span0.3 % for r < 5 r × 0.06 % for 5 < r < 10

0.2 % for r < 10r × 0.02 % for 10 < r < 40

0.2 % for r < 10r × 0.02 % for 10 < r < 50

0.2 % for r < 10r × 0.02 % for 10 < r < 20

Long-term stability as % of nominal measuring range

0.1 %/year

Mark of conformity Testing laboratoryCertificate/certification number

Test basis Valid for

ATEX electrosuisse SEV 09 ATEX 0138 XEN 60079-0EN 60079-11EN 60079-26

403025/x-1-...

EHEDG TUM MAK 03/2006 Document No.8Process connection 997 ( PEKA)

INMETRO CEPEL CEPEL 13.2213XIEC 60079IEC 60529

Extra code 227

DNV Det Norske Veritas AS A-13300Testing report 203951/4 dated 2012-06-13

403025/x-1-.../880

GOST-R

Ambient conditions

Accuracy

Approvals/marks of conformity

Page 5: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

5

Technical Specifications

Process connection for material 20316L at front-flush process connection 316Ti sonst

Process connection for material 82 2.4819 NiMo

Surface Ra 0.8 µm

Process seal for process connection 512 and 571

FPM

Process seal for process connection 652

FPM

Process seal for process connection 997 ( PEKA)

Without a seal

Process seal for all other process connections

Display field 22 × 35 mm/font size 7 mm/5 digits

Measuring membrane for material 20

1.4542 at measuring range 516 316L sonst

Measuring membrane for material 82

2.4819 NiMo

Measuring membrane surface Ra 0.8 µm

Housing material for housing 1 (short, stainless steel)

Stainless steel 1.4404

Housing material for housing 2 (long, stainless steel)

Stainless steel 1.4404, VMQ

Housing material for housing 3 (precision casting)

Precision casting 1.4408

Housing material for cover materi-al 20 (stainless steel)

Precision casting 1.4408, FPM seal

Housing material for cover materi-al 85 (plastic)

PA, FPM seal

Housing material for electrical co-nnection 36 (M12 × 1 round plug)

Nickel-plated brass

Housing material for electrical co-nnection 82 (cable gland, plastic)

PA

Housing material for electrical connection 93 (cable gland, metal)

Nickel-plated brass

Housing material for operation 0 (without control knob)

-

Housing material for operation 1 (with control knob)

PA

Explosion protection for explosion protection 1 (ATEX Ex ia)

EC type examination certificate SEV 09 ATEX 0138 X II 1/2G Ex ia IIC T6 to T3 Ga/GbII 1/2D Ex ia IIIC T105 °C Da/Db

Weight of type 403025/0-0-1 (short housing)

Approx. 550 g

Weight of type 403025/0-0-2 (long housing)

Approx. 850 g

Weight of type 4030252/0-0-3(precision casting housing) Approx. 1600 g

Connection Terminal assignment Cable gland Round plug, M12 × 1

Voltage supplyfor non Ex version DC 11.5 to 36 Vfor Ex version DC 11.5 to 30 V

1 L+ 2 L-

1 L+ 3 L-

Output4 to 20 mA two wireImpressed current 4 to 20 mA in voltage supply

1 L+ 2 L-

1 L+ 3 L-

Current output test connectionInherent resistance of ammeter 10

TEST + TEST -

CEPEL 13.2213X

HART® test connectionThe burden must be present!

HART + HART -

A-13300

Functional ground3 4

Mechanical properties

Electrical connection

Page 6: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

6

Ordering specifiation codes

Page 7: datasheet - Arkonarkon.co.uk/pdf/Differential_pressure/DIFP20/Data... · Version with explosion protection 0 (none) IP 67 to DIN EN 60529 Version with explosion protection 1 (ATEX

7

Arkon Flow SystemsNováčkova 11, 614 00 Brno, Czech Republic

Tel. +420 543 214 822, Tel./Fax +420 543 215 249Enquiries/Orders/General questions: [email protected] support/brochures: [email protected]

Technical support: [email protected]

version 5/2015