data
DESCRIPTION
Technical dataTRANSCRIPT
Technical Data
56 311164P
Technical Data
Maximum Working Pressure and Flow Rate at Full Air Pressure (100 psi)
* At 80 psi (0.55 MPa, 5.5 bar)† At 90 psi (0.62 MPa, 6.2 bar)
Maximum air inlet pressure Models with 16:1 - 70:1 pressure ratios: 100 psi (0.7 MPa, 7 bar).Models with 80:1 pressure ratios: 90 psi (0.62 MPa, 6.2 bar). Models with a 90:1 pressure ratio: 80 psi (0.55 MPa, 5.5 bar).
Air motor piston diameter NXT Model 6500: 10.375 in. (264 mm)
NXT Model 3400: 7.5 in. (191 mm)
NXT Model 2200: 6.0 in. (152 mm)
Stroke length 4.75 in. (120 mm)
Air Inlet Size 3/4 npt(f)
Fluid Inlet Size 1-1/4 npt(m)
Fluid Outlet Size All pumps with built-in filters (2 outlet ports): 1/2 npt(m)
Pumps without built-in filters (1 outlet port):
85cc and 115cc pumps: 1/2 npt(f)145cc and 180cc pumps: 3/4 npt(f)220cc, 250cc, and 290cc pumps: 1 npt(f)
Maximum pump speed(Do not exceed maximum recommended speed of fluid pump, to prevent premature pump wear)
60 cycles per minute
NOTE: See NXT Motor manual (311238) for sound data.
RatioMaximum Working
Pressure psi (MPa, bar) NXT Air MotorLower
(cc per cycle)
Flow Rate gpm (lpm)
30 cpm 60 cpm
16:1 1520 (10.5, 105) 2200 290 2.3 (8.7) 4.6 (17.0)
21:1 2025 (14.0, 140) 2200 220 1.74 (6.6) 3.4 (12.9)
24:1 2400 (16.5, 165) 2200 180 1.43 (5.4) 2.9 (11.0)
25:1 2375 (16.4, 164) 3400 290 2.3 (8.7) 4.6 (17.0)
30:1 3150 (21.7, 217) 3400 220 1.74 (6.6) 3.4 (12.9)
31:1 3000 (20.7, 207) 2200 145 1.15 (4.4) 2.3 (8.7)
35:1 3800 (26.2, 262) 2200 115 0.95 (3.6) 2.0 (7.6)
40:1 3800 (26.2, 262) 3400 180 1.43 (5.4) 2.9 (11.0)
45:1 4500 (31.0, 310) 6500 290 2.3 (8.7) 4.6 (17.0)
46:1 4750 (32.7, 327) 3400 145 1.15 (4.4) 2.3 (8.7)
50:1 5000 (34.5, 345) 6500 250 2.0 (7.6) 4.0 (15.2)
55:1 5600 (38.6, 386) 3400 115 0.95 (3.6) 2.0 (7.6)
60:1 6000 (41.7, 417) 6500 220 1.74 (6.6) 3.4 (12.9)
70:1 7250 (50.0, 500) 6500 180 1.43 (5.4) 2.9 (11.0)
80:1 7250 (50.0, 500) 3400 85 0.8 (3.0)† 1.5 (5.7)†
90:1 7250 (50.0, 500) 6500 145 1.15 (4.4)* 2.3 (8.7)*
Pump Package Performance Charts
311164P 57
Pump Package Performance Charts
Calculate Fluid Outlet Pressure
To calculate fluid outlet pressure (psi/MPa/bar) at a spe-cific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar), use the following instructions and pump data charts.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet pressure curve. Follow left to scale to read fluid outlet pressure.
Calculate Pump Air Flow/Consumption
To calculate pump air flow/consumption (scfm or
m3/min) at a specific fluid flow (gpm/lpm) and air pres-sure (psi/MPa/bar), use the following instructions and pump data charts.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected air flow/consumption curve. Follow right to scale to read air flow/consumption.
16:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
800
1200
1600
400
0 2.0 3.01.0(3.8) (7.6) (11.4)
4.0(15.2)
21:1 Xtreme Pumps
Fluid Flow in gpm (lpm)
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
) Air F
low
in S
CF
M (m
3/min
)
0 2.0 3.01.0(3.8) (7.6) (11.4)
(11.2, 112)
(8.4, 84)
(5.6, 56)
(2.8, 28)
24:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Air F
low
in S
CF
M (m
3/min
)
Fluid Flow in gpm (lpm)
0 2.0 3.01.0(3.8) (7.6) (11.4)
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
0 5.03.0
Air F
low
in S
CF
M (m
3/min
)
25:1 Xtreme Pumps
(11.4) (19.0)1.0
(3.8)
Key: Air PressureA 100 psi (0.7 MPa, 7 bar)B 70 psi (0.5 MPa, 7.8 bar)C 40 psi (0.3 MPa, 2.8 bar)
Dashed lines indicate low noise motors.
80(2.2)
60(1.7)
40(1.1)
20(0.6)
80(2.2)
60(1.7)
40(1.1)
20(0.6)500
1500
2500(17.5, 175)
(10.5, 105)
(3.5, 35)
500
1500
2500(17.5, 175)
(10.5, 105)
(3.5, 35)
80(2.2)
60(1.7)
40(1.1)
20(0.6)
500
1500
2500(17.5, 175)
(10.5, 105)
(3.5, 35)
160(4.5)
120(3.4)
80(2.2)
40(1.1)
A
C
A
A
B
B
CC
AA
A
AA
B B
B
BB
C
C
C
CC
B
Pump Package Performance Charts
58 311164P
Pump Package Performance Charts (cont.)
0 1.0 2.0 3.0 4.0
30:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6) (11.4) (15.2)
3500(24.5, 245)
2500(17.5, 175)
1500(10.5, 105)
500(3.5, 35)
31:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
0 2.0 3.01.0(3.8) (7.6) (11.4)
0 1.0 2.0
35:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6)
0 2.0 3.01.0
40:1 Xtreme PumpsF
luid
Pre
ssu
re in
psi
g (
MP
a, b
ar)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6) (11.4)
0 2.0 3.01.0
46:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6) (11.4)
45:1 Xtreme Pumps
Air F
low
in S
CF
M (m
3/min
)
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
0 5.03.0(11.4) (19.0)
1.0(3.8)
160(4.5)
120(3.4)
80(2.2)
40(1.1)
120(3.4)
80(2.2)
40(1.1)
2000
3000(21.0, 210)
(14.0, 140)
1000 (7.0, 70)
1.5(5.7)
0.5(1.9)
120(3.4)
80(2.2)
40(1.1)
2000
3000
4000
1000
(28.0, 280)
(21.0, 210)
(14.0, 140)
(7.0, 70)
2000
3000
4000
1000
(28.0, 280)
(21.0, 210)
(14.0, 140)
(7.0, 70)
160(4.5)
120(3.4)
80(2.2)
40(1.1)
250(7.0)
150(4.2)
50(1.4)
2000
3000
4000
1000
(28.0, 280)
(21.0, 210)
(14.0, 140)
(7.0, 70)
5000(35.0, 350)
250(7.0)
150(4.2)
50(1.4)
2000
3000
4000
1000
(28.0, 280)
(21.0, 210)
(14.0, 140)
(7.0, 70)
5000(35.0, 350)
A
C
B
A
A
A
A
A
B
B
B
BB
B
C
CC
C
C
C
A
A
AA
A
A
B
B
B
B
B
C
C
C
C
C
Pump Package Performance Charts
311164P 59
Pump Package Performance Charts (cont.)
0 0.5 1.0 1.5 2.0
55:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(1.9) (5.7)(3.8) (7.6)
0 1.0 2.0 3.0 4.0
60:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6) (11.4) (15.2)0 2.0 3.01.0
70:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6) (11.4)
90:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
0
Key: 90:1 Pumps Air PressureB 80 psi (0.56 MPa, 5.6 bar)C 40 psi (0.28 MPa, 2.8 bar)
0 1.0 4.02.0 3.0
50:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
(3.8) (7.6) (11.4) (15.2)
AA
C
B
250(7.0)
150(4.2)
50(1.4)
200(5.6)
100(2.8)2000
3000
4000
1000
(28.0, 280)
(21.0, 210)
(14.0, 140)
(7.0, 70)
6000(42.0, 420)
B
B
B
B
C
C
C
C
C
C
5000(35.0, 350)
7000(49.0, 490)
160(4.5)
80(2.2)
120(3.4)
40(1.1)
A
A
B
B
AA
250(7.0)
150(4.2)
50(1.4)
200(5.6)
100(2.8)
3000
1000
(21.0, 210)
(7.0, 70)
5000(35.0, 350)
7000(49.0, 490)
AA
B
B
C
C
250(7.0)
150(4.2)
50(1.4)
200(5.6)
100(2.8)
4000
2000
(28.0, 280)
(14.0, 140)
6000(42.0, 420)
8000(56.0, 560)
B
C
1.0 2.0 3.0(7.6)(3.8) (11.4)
250(7.0)
150(4.2)
50(1.4)
200(5.6)
100(2.8)
4000
2000
(28.0, 280)
(14.0, 140)
6000(42.0, 420)
8000(56.0, 560)
0
80:1 Xtreme Pumps
Flu
id P
ress
ure
in p
sig
(M
Pa,
bar
)
Fluid Flow in gpm (lpm)
Air F
low
in S
CF
M (m
3/min
)
160(4.5)
120(3.4)
80(2.2)
40(1.1)
AA
B
B
C
C4000
2000
(28.0, 280)
(14.0, 140)
6000(42.0, 420)
8000(56.0, 560)
0.5 1.0 1.5 2.0(1.9) (5.7)(3.8) (7.6)