data sheet- overhead travelling
TRANSCRIPT
-
D3 6-Oct-08 Teerasak Ch. Teerasak Ch. Teerasak Ch. Naret V.D2 12-Jun-08 Sahaporn P.D1 2-Apr-09 Sahaporn P.
Contract No. PTT Project No. Order No.0804.02
Contractor Client Consultant
Engineer
CHECKED BY PTT
APPROVED BY PTTREV. DATE DESCRIPTION
PREPARED BY PTT
REVIEWED BY PTT
ELECTRIC OVERHEAD TRAVELLING (E.O.T.) CRANEDS-30-0804.02-6000-002
Revision Issued for ITB
Issued for ITBIssued for ITB
PTT PUBLIC COMPANY LIMITEDONSHORE COMPRESSOR STATION 4 PROJECT
DATA SHEETFOR
-
PROJECT NO. 0804.02
PROJECT NAME Onshore Compressor Station 4 (OCS 4)
TAG NO.
DATA SHEET NO. DS-30-0804.02-6000-002 REV NO. D3PAGE 2 OF 4
1 SERVICE : Compressor Shelter UNIT 6000 PLANT LOCATION MAP TA PHUT, RAYONG PROVINCE, THAILAND2 OWNER : PTT QTY. 3 TYPE OF DUTY Occasional34 Main Hoist Location Map Ta Phut, Rayong Thai land5 Auxiliary Hoist (option) Temperature 11 - 45 C6 Span and Dimension Relative Humidity 51 - 93 %7 Crane Girder Type Wind Speed None8 Operating Speed Speed(m/min) Indoor Heated Roof9 Main Hoist : (unload/max. load) * Outdoor Unheat Mon
10 Trolley : (unload/max. load) * Area Classification Class 1 Div 211 Bridge : (unload/max. load) *12 Hook Type Swivel Fixed13 Safety Catch Yes No Bridge Girder CS, box or beam type14 Motor Type Drum Steel15 Bridge Motor * Wheel Bronze Alloy (Note1)16 Trolley Motor * Hoist CS or Cast Iron17 Hoist Motor * Shafts/Pins CS18 Rail Details Rope Winding Wire19 Vendor to supply rails Yes No Bumper Rubber20 Type of rail fixings * Bearing Bronze Alloy (Note1)21 Type & Size of rail * Brake DC Disc Type22 Crane Rail Girder Yes No Auxiliary *23 Parking Brake Yes No Anticollision *24 End Stop Yes No25 Runway Beam2627 Control Type : Full magnetic in NEMA enclosure Power Supply : 380 V / 3Ph / 50 Hz28 Thermal Overload : Yes No Conductor System :29 Control Circuit : Yes No30 Main Contractor : Yes No31 Limit Switch Yes No (Upper & Lower) Isolator Box : Yes No32 Lighting : (Note 4) Yes No33 Cable Track : Steel Stainless Steel34 Operation : Pendant Cab Motor Classification : Class 1 Zone 2 IIB T3353637 SPC-0804.02-30.16 Electrical Overhead Travelling Crane38 SPC-0804.02-93.06 Painting39 SPC-0804.02-91.01 Equipment Noise Specification40 SPC-0804.02-99.05 Spare Parts41 Total Crane Weight : * ( No Load) SPC-0804.02-99.03 Shop inspection42 Test Weight : * SPC-0804.02-99-00.05 Basic engineering design data43 Service Condition : Every 6 months SPC-0804.02-99.01 Numbering System44 Walkway Required : Yes No45 Special Maintenance Facilities : *46 Other Code & Specification : BS 466, CMAA Class B47 Painting : Project Spec. ES-92.0648 Other Crane on Gantry : Yes No49 Anticollision System : Yes No50 No. of Wheels: *51 Wheel Loads: (Static/Dynamic) *52 Bearing Life : Min. 10,000 hrs5354 1. Vendor to provide materials to avoid sparking.55 2. Capacity of Overhead Crane shall be heaviest part what will be maintenanced.56 3. Lighting system including to under ovehead crane shall be provided according to Thai Regulation.57 4. SWL sign will be applied to the international standard.58 5. Walk Ways are required for access to all accessaries of Crane what required for Maintenance or repair.
Operation Station : Pushbutton station suspended from festooned track system.
CRANE DETAIL
Cable Reel Drum
Cab & Pendant
SITE CONDITION
MATERIALS (Note 1)
20 tons*
ELECTRIC OVERHEAD TRAVELLING (E.O.T.) CRANEDATA SHEET
(By Other)
Motor Power(kw)*
*
*
Raise & Lower Pendant
EQUIPMENT NAME 6000-Y-101A/B/CElectric Overhead Travelling Crane (Compressor Shetter)
See attach sketchDouble
Conductor
PTT PLUBLIC COMPANY
Festoon Cable
CONTROL SYSTEM ELECTRICAL SYSTEM
NOTES
Sliding Pendant
Slide, raise & lower pendant(Pendant to be lockable)
OTHER REQUIREMENT
APPLICABLE SPECIFICATIONS Fixed Pendant
DESC
RIPT
ION
CHK/
APP
DATE
REV
NO.
PREP
DDE
SCRI
PTIO
NCH
K/AP
PDA
TERE
V NO
.PR
EPD
DESC
RIPT
ION
CHK/
APP
DATE
REV
NO.
PREP
DDE
SCRI
PTIO
NCH
K/AP
PDA
TEPR
EPD
REV
-
PROJECT NO. 0804.02
PROJECT NAME Onshore Compressor Station 4 (OCS 4)
TAG NO.
DATA SHEET NO. DS-30-0804.02-6000-002 REV NO. D3
PAGE 3 OF 4
1 SERVICE : Work Shop UNIT 6000 PLANT LOCATION MAP TA PHUT, RAYONG PROVINCE, THAILAND2 OWNER : PTT QTY. 3 TYPE OF DUTY Occasional34 Main Hoist Location Map Ta Phut, Rayong Thai land5 Auxiliary Hoist (option) Temperature 11 - 45 C6 Span and Dimension Relative Humidity 51 - 93 %7 Crane Girder Type Wind Speed None8 Operating Speed Speed(m/min) Indoor Heated Roof9 Main Hoist : (unload/max. load) * Outdoor Unheat Mon
10 Trolley : (unload/max. load) * Area Classification Class 1 Div 211 Bridge : (unload/max. load) *12 Hook Type Swivel Fixed13 Safety Catch Yes No Bridge Girder CS, box or beam type14 Motor Type Drum Steel15 Bridge Motor * Wheel Bronze Alloy (Note1)16 Trolley Motor * Hoist CS or Cast Iron17 Hoist Motor * Shafts/Pins CS18 Rail Details Rope Winding Wire19 Vendor to supply rails Yes No Bumper Rubber20 Type of rail fixings * Bearing Bronze Alloy (Note1)21 Type & Size of rail * Brake DC Disc Type22 Crane Rail Girder Yes No Auxiliary *23 Parking Brake Yes No Anticollision *24 End Stop Yes No25 Runway Beam2627 Control Type : Full magnetic in NEMA enclosure Power Supply : 380 V / 3Ph / 50 Hz28 Thermal Overload : Yes No Conductor System :29 Control Circuit : Yes No30 Main Contractor : Yes No31 Limit Switch Yes No (Upper & Lower) Isolator Box : Yes No32 Lighting : (Note 4) Yes No33 Cable Track : Steel Stainless Steel34 Operation : Pendant Cab Motor Classification : Class 1 Zone 2 IIB T3353637 SPC-0804.02-30.16 Electrical Overhead Travelling Crane38 SPC-0804.02-93.06 Painting39 SPC-0804.02-91.01 Equipment Noise Specification40 SPC-0804.02-99.05 Spare Parts41 Total Crane Weight : * ( No Load) SPC-0804.02-99.03 Shop inspection42 Test Weight : * SPC-0804.02-99-00.05 Basic engineering design data43 Service Condition : Every 6 months SPC-0804.02-99.01 Numbering System44 Walkway Required : Yes No45 Special Maintenance Facilities : *46 Other Code & Specification : BS 466, CMAA Class B47 Painting : Project Spec. ES-92.0648 Other Crane on Gantry : Yes No49 Anticollision System : Yes No50 No. of Wheels: *51 Wheel Loads: (Static/Dynamic) *52 Bearing Life : Min. 10,000 hrs5354 1. Vendor to provide materials to avoid sparking.55 2. * To be confirm and specify by contractor.56 3. Capacity of Overhead Crane shall be heaviest part what will be repaired.57 4. Lighting system including to under ovehead crane shall be provided according to Thai Regulation.58 5. SWL sign will be applied to the international standard.59 6. Walk Ways are required for access to all accessaries of Crane what required for Maintenance or repair.
Festoon Cable
CONTROL SYSTEM ELECTRICAL SYSTEM
NOTES
Sliding Pendant
Slide, raise & lower pendant(Pendant to be lockable)
OTHER REQUIREMENT
APPLICABLE SPECIFICATIONS Fixed Pendant
Raise & Lower Pendant
EQUIPMENT NAME 6000-Y-102A/B/CElectric Overhead Travelling Crane (Work Shop)
See attach sketchDouble
Conductor
PTT PLUBLIC COMPANYELECTRIC OVERHEAD TRAVELLING (E.O.T.) CRANE
DATA SHEET
(By Other)
Motor Power(kw)*
*
*
Operation Station : Pushbutton station suspended from festooned track system.
CRANE DETAIL
Cable Reel Drum
Cab & Pendant
SITE CONDITION
MATERIALS (Note 1)
(Note 3) tons*
-
PROJECT NO. 0804.02
PROJECT NAME Onshore Compressor Station 4 (OCS 4)
TAG NO.
DATA SHEET NO. DS-30-0804.02-6000-002 REV NO. D3
PAGE 4 OF 4
1
234
5
67
89
1011
12
1314
15
1617
18192021
22
2324
25
2627
2829303132333435363738394041
42
4344
45
4647
48495051
52
5354
55
56
Note: This drawing for information only, the actual one shall be verified by Contractor.57
EQUIPMENT NAME 6000-Y-101A/B/CElectric Overhead Travelling Crane
PTT PLUBLIC COMPANYELECTRIC OVERHEAD TRAVELLING (E.O.T.) CRANE
DATA SHEET
CRANE SKETCH