data center measurement
DESCRIPTION
Data Center Measurement - Building An ROI Baseline Establishing a baseline measurement of your data center is an important first step in developing a meaningful ROI for any data center project. The cost of energy has recently exceeded the cost of IT equipment; understanding your energy footprint in terms of power consumption and cooling demand has become an important management tool. to view the recorded webinar presentation, please visit http://www.42u.com/measurement-techniques-webinar.htmTRANSCRIPT
42U Confidential ©2008 42U All rights reserved Slide 1
Data Center Measurement – Building An ROI Baseline
August 22, 2008
________________________________
Overview
• Big Picture– Why Measure– What to Measure– How To Measure
• Visualization Primer• Case Study• Summary• Q&A
42U Confidential ©2008 42U All rights reserved Slide 2
Why Measure
• Service Level Agreement (SLA)• Information Technology
Infrastructure Library (ITIL)• Total Cost of Ownership (TCO)• Actual Versus Designed• Stranded Capacity• “Can’t Manage What You Can’t
Measure”
42U Confidential ©2008 42U All rights reserved Slide 3
Energy Cost Projection
42U Confidential ©2008 42U All rights reserved Slide 4
Source: Aperture, Greener Pastures for Your Data Center
Energy Benchmark
• Established Benchmark
• Enables Comparison
42U Confidential ©2008 42U All rights reserved Slide 5
Source: The Green Grid
Energy Consumers
• 70% of Power Consumption Goes to the Infrastructure
• Over Twice that of the IT Equipment
42U Confidential ©2008 42U All rights reserved Slide 6
Source: The Green Grid, Guidelines for Energy-Efficient Datacenters
What To Measure
• Power
• Temperature
• Air Pressure
• Humidity
• Water Flow & Temperature
42U Confidential ©2008 42U All rights reserved Slide 7
Best Practice Opportunities
• Chilled Water
• Fans
42U Confidential ©2008 42U All rights reserved Slide 8
Source: Accenture Data Center Energy Forecast Report, July11, 2008
How To Measure
• Level of Precision
• Alternatives– Point In Time– Ongoing– Real-Time
• Modeling Tool Requirements
42U Confidential ©2008 42U All rights reserved Slide 9
Visualization Tools
• System Admins
• Network Admins
• Data Center Managers
42U Confidential ©2008 42U All rights reserved Slide 10
Real-Time Imaging
42U Confidential ©2008 42U All rights reserved Slide 11
Real-Time Imaging
42U Confidential ©2008 42U All rights reserved Slide 12
CFD Visualization
Computational Fluid Dynamics (CFD)
42U Confidential ©2008 42U All rights reserved Slide 13
Case Study
• Lawrence Berkeley National Lab– Continued Increase in Demand– Data Center Capacity ~2011– Strategic Imperative on Efficiency
• Study Results– Improve Airflow– Virtualization– Water Cooling
42U Confidential ©2008 42U All rights reserved Slide 14
Efficiency MeasurementLife-CycleTM
42U Confidential ©2008 42U All rights reserved Slide 15
Reconfiguration
• Measurement Points• Measurement Object Database• Security
• Hardware Configuration & Testing• Network Configuration & Testing• Sensor Installation• Software Installation• Network Verification
• Data Collection• Analysis• System Management
• Facilities Data• IT Infrastructure Data• IT Equipment Data• Integration Requirements
Survey
Planning
Installation
Measurement
Wireless Sensor Network
42U Confidential ©2008 42U All rights reserved Slide 16
Confirmation of Fundamentals
• Impact of a Single Blanking Panel
• Consistent Results For– Floor Leaks– Tile
Arrangement
Top of rack
Middle of rack
42U Confidential ©2008 42U All rights reserved Slide 17
Floor Tile Tuning
• One Day Time Investment– 24 Converted
from Perforated to Solid
– 6 Converted from High- to Low- Flow
– 4 Converted from Low- to High- Flow
Before
After
42U Confidential ©2008 42U All rights reserved Slide 18
Results of Tuning
• Real-Time Verification
• Eliminates Guesswork
Under-Floor Pressure
Rack-Top Temperatures
42U Confidential ©2008 42U All rights reserved Slide 19
Air Flow Tuning
42U Confidential ©2008 42U All rights reserved Slide 20
Measureable Correlations
• Real-Time Feedback
• Enhanced Knowledge of Data Center Redundancy Characteristics
Under-Floor Pressure
Rack-Top Temperatures
42U Confidential ©2008 42U All rights reserved Slide 21
Summary
• Planning– What To Measure– How To Measure
• Interpreting Results
• Efficiency Improvement Plan– Rank By ROI
42U Confidential ©2008 42U All rights reserved Slide 22
Q&A