daniel t. child - general manager - us epa...require 16 kwh per ton (electricity) air - 65°f . air...
TRANSCRIPT
![Page 1: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/1.jpg)
![Page 2: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/2.jpg)
Daniel T. Child - General Manager
Dario Presezzi - CEO
![Page 3: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/3.jpg)
“Biosolids to energy”
![Page 4: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/4.jpg)
![Page 5: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/5.jpg)
energy-positive in-house additive-free useful byproducts
![Page 6: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/6.jpg)
![Page 7: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/7.jpg)
NO external energy Fully automated
Low maintenance
INDEPENDENT
![Page 8: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/8.jpg)
TOO MUCH WATER!
![Page 9: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/9.jpg)
REMOVE WATER
2000 lb of Biosolids (25% solid)
720 lb of Biosolids (70% solid)
450 kWh 1500 lb of water
(thermal energy)
![Page 10: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/10.jpg)
![Page 11: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/11.jpg)
“the energy that is not conserved biologically as chemical energy (ATP formation) is liberated as heat
(308,000 cal)” http://www.ncbi.nlm.nih.gov
![Page 12: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/12.jpg)
BIOLOGICAL DRYER • Energy from bacterial biochemical
reactions
• Reaches 140°F in 12 hours (no external heat)
• From 25% solid to 70% solid in 48 hours
• AI Controlled - Fully Automated
• Require 16 kWh per ton (electricity) Air - 65°F
Air - 140°F
Air - 120°F
Air - 85°F
![Page 13: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/13.jpg)
![Page 14: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/14.jpg)
25% 44% 70%
25°C
60°C
24 hours 48 hours 12 hours
![Page 15: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/15.jpg)
JUNE 2013
![Page 16: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/16.jpg)
BFT PILOT DRYER • Dryer Capacity : 400 kg
• 6 months of testing at SVCW
![Page 17: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/17.jpg)
“Biosolids to energy”
![Page 18: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/18.jpg)
PRODUCE CLEAN ENERGY : PYROLYSIS
“Pyrolysis is a thermochemical decomposition of organic material at elevated temperatures in the absence of
oxygen”
![Page 19: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/19.jpg)
PYROLYSIS REACTOR • Self-sustained process
• Additive-free
• Rector temperature - 1100°F
• Conversion efficiency : 85%
• Process time : 30 min ca.
• Clean emissions
• NON-HAZARDOUS Ash
70% Biosolids
600°C
1100°F
Syngas 850°C
Ash
Boiler
Hot-Water
![Page 20: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/20.jpg)
Macquarie University - Australia
Rice University - Houston TX, USA
Madrid University - Spain
Beijing University - China
![Page 21: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/21.jpg)
ENERGY & MASS BALANCE
25% Biosolid
2000 lb
Bio-Dryer
70% Biosolid
720 lb
48 hours
-16 kWh
Pyrolysis
30 min BioChar
220 lb
Heat
+200 kWh th
+ 30 kw e - Stirling
![Page 22: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/22.jpg)
2000 LB OF BIOSOLIDS + 230 kWh
(carbon negative)
+ 220 lb (useful byproduct)
-90% (transportation)
fixed price (15 years)
Additive free
Operators free
![Page 23: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/23.jpg)
FULL SCALE BIO-DRYER MAY 2014
![Page 24: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/24.jpg)
FULL SCALE BFT-DRYER • Dryer Capacity : 9 ton
• Length : 40 feet
• Fully automated by AI
• Quality :
• Stainless Steel
• Made in Italy
• 60 years of experience
• fully recyclable (PVC free)
![Page 25: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/25.jpg)
![Page 26: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/26.jpg)
NEXT WEEK Visitors are welcome ;)
![Page 27: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/27.jpg)
FULL SCALE BFT-PLANT
![Page 28: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/28.jpg)
• 8 to 10 full scale Dryers
• 100 feet x 100 feet
• Fully automated : no operators
• Pyrolysis : 1000 lb/h
• electricity : 40 kWh (stirling)
• Output : 300 kWh & 330lb BioChar
13.000 tons/year
![Page 29: Daniel T. Child - General Manager - US EPA...Require 16 kWh per ton (electricity) Air - 65°F . Air - 140°F . Air - 120°F . ... Bio-Dryer. 70% Biosolid 720 lb 48 hours -16 kWh Pyrolysis](https://reader035.vdocuments.us/reader035/viewer/2022070903/5f699011eb03c31c4770ffa6/html5/thumbnails/29.jpg)
Let’s make it green
FOR REAL