[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 1
Daniel Gas Ultrasonic The benefits of combination
of reflective and direct path
Thomas Sautier
Metering Product Manager
Flow Europe
March 2016
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 2
Introduction / Agenda
• Customers worldwide have adopted Ultrasonic flow measurement for Custody Transfer Gas Measurement
• Multi Path technology with generally either 100% Chordal or 100% Reflective paths configuration provides the best achievable calibrated accuracy… Both have Pros and Cons.
• Even if fiscal metering & dirty gas doesn’t go together well, the reality in the field is different.
• During operation, uncertainties due to process change, possible contamination, liquid & wet gas can be an issue.
• Emerson Daniel has 25 years of experience with both Chordal & Reflective technology and believe combination of best of both worlds can help
– To increase the confidence level of the US meter
– To get early warnings in case of process related issues of these operational uncertainties.
Agenda :
1. Chordal /Reflective comparison : Theorical & Applicative approach
2. Field cases in North America of combination of both technologies
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 3
Is chordal design better than reflective in fiscal Ultrasonic Gas
measurement?
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 4
General Comparison : Reflective Vs Chordal
Chordal Reflective
Robustness + -
Multi path configuration + +
Non axial flow cancellation - +
Resolution - +
Attenuation + -
Reynold’s dependency + -
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 5
Emerson Daniel Chordal Vs Reflective / Theorical appoach
• Multi Paths meters
• Horizontal paths
• Weighting
• Shorter length
• Average of weight chord velocities calculation
• 1 or 2 path meters
• Any orientation
• Travel center line
• Longer length (Approx Twice)
• Pipe Roughness / Reynold’s Correction in flow calculation
Daniel USM 3411/12
Reflective Paths Daniel USM 3414
Chordal Paths
VMean
835.0
.2703.0
0.2421
8.0
eRd
WRLOG
CF
CFQQCor . .
1221
1221
2
t. t
t- t . X 2
L V
n
iiaverage vwV1
AVQ average
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 6
• Less path configuration, lower accuracy
– Center line, No Weighting
• More sensitive to flow disturbance
– Effect on velocity for non developped flow profile / Error on CF
• In case of contamination / corrosion
– Path lengths change
– Pipe Roughness change Flow profiles become more pointed = Influence in CF
– Depending on build up, signal dispersed
• In case of wet gas / liquid
– Signal Attenuation / Path Lengths change / Deviated bounce (wave)
– Risk for liquid covering target bounce area
• Longer installation requirement
Daniel USM 3411/12
Reflective Paths
Emerson Daniel Chordal Vs Reflective / Applications
• Multi path design, best accuracy
• Less sensitive to flow disturbance
• In case of contamination / corrosion
– No effect on path lengths (except if contamination on transducer itself)
– Doesn’t affect the SOS & velocity measurement
– Overeading in Q caused by contamination
• In case of wet gas
– No effect on path lengths
– More Gain
• Reduced installation requirement
Daniel USM 3414
Chordal Paths
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 7
Emerson Daniel Chordal Vs Reflective / Diagnostics
• Multiple paths then multiple diagnostics
• Basic Functional diagnostics
SOS / Gain / Performance / SNR
• Advanced Dynamic Flow Based diagnostics
Profile factor /
Symmetry / Cross flow / Swirl
• 1 or 2 paths, less diagnostics
• Only Functional Diagnostics
Daniel USM 3411/12
Reflective Paths Daniel USM 3414
Chordal Paths
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 8
Chordal + Reflective / Contradictive Combination
Chordal Paths Reflective Path
Best Accuracy
Still Measure with harsh conditions
ROBUSTNESS
Responsive with pipe wall change
Early detection in case of liquid
SENSITIVITY +
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 9
Field case : Gas Pipeline Company in NA
• Big number of metering stations equiped with several metering lines since more than 15 years
• Size 6’’ to 12’’
• Unidirectional or bidirectional metering installations
• Remote site, takes few hours to get in the metering stations
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 10
Typical applications / Combination of Junior & Senior
• All metering stations is a combination of a primary meter Senior & Check meter Junior sonic.
• Alarm if >1% deviation between 2 meters over 24h
• Typical customer issue for gas measurement
– Shale gas / sludge => no consistant
– Operational Issues during production
– Grease from valve, components.
– Construction debris
• Purpose of the combined installation
– Check the integrity of their Fiscal Measurement
– Early warnings of process change
– Part of quality standard
– Meet stringent local regulations
– Intervention program (extend calibration period)
PRIMARY METER
SENIOR SONIC
4 PATHS CHORDAL
CHECK METER
JUNIOR SONIC
1 PATH REFLECTIVE
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 11
TC Typical applications / Layout
• Includes Flow conditioner
• 5 + 10 D Upstream
• Specific 10D design for Junior Sonic with tapping
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 12
Field Case / Oil Film detection
Pipe Wall Contamination
with Viscous Fluid Coating
DIAGNOSTIC
BASELINE VIEWER
No indication of process change
in the most advanced
Dynamic Flow Diagnostics
1P 1C
2P 2C
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 13
Field Case / Oil Film detection
Pipe Wall Contamination
with Viscous Fluid Coating
Deviation
between 1P & 1C
Clear Continuous Slow shift
away in indicates clearly process
change
1P 1C
2P 2C
-3,00%
-2,00%
-1,00%
0,00%
1,00%
2,00%
3,00%
4-25-2014 5-10-2014 5-25-2014 6-9-2014
1P vs 1C
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 14
Field Case / Oil Film detection
Pipe Wall Contamination
with Viscous Fluid Coating
Deviation
between 1P & 1C / 2P & 2C
Deviation between 1P/1C shows
stronger deviation because of
contamination.
1P 1C
2P 2C
-20
-15
-10
-5
0
5
10
15
20
% diff. 1P/1C % diff. 2P/2C
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 15
Field Case / Blockage & Debris
Flow Conditioner Blockage
1P 1C
-2,00%
-1,50%
-1,00%
-0,50%
0,00%
0,50%
1,00%
1,50%
2,00%
2,50%
3,00%
3,50%
1P-1C
“It was fairly consistent at 3%
variance between 1P and 1C. WE
were surprised at how little of an
obstruction it was though...we
were betting on an object much
bigger than that. Shows exactly
how sensitive these meters are.”
Standard deviation
between 1P & 1C
Clear Deviation of about 3%
during more than 15 days.
Suspision of a major operational
issue…
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 16
Field Case / Blockage
Flow Conditioner Blockage
DIAGNOSTIC
No indication of process change
in the most advanced
Dynamic Flow Diagnostics a
1P 1C
Primary meter Flow
Rate
It looks like it still
measures correctly…
Even if the meter raises
an alarms in flow profile
« Possible Blockage
detected ».
Error in 1P-1C standard
deviation help to clearly
proove it is not a false
alarm
Before Blockage
removed
After Blockage
removed
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 17 Flow Conditioner Blockage
DIAGNOSTIC
No indication of process change
in the most advanced
Dynamic Flow Diagnostics
Our customer notes the
magnitude of shift
between the two meters
which they take into
account when doing
maintenance or shutdown
planning. Large error,
means immediate action.
Small shifts first mean
going through logs rather
than a shutdown.
Field Case, same customer. Similar experience
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 18 Valve Grease
DIAGNOSTIC
No indication of process change
in the most advanced
Dynamic Flow Diagnostics
Our customer also notes
the magnitude of shift
between the two meters
which they take into
account when doing
maintenance or shutdown
planning. Large error,
means immediate action.
Small shifts first mean
going through logs rather
than a shutdown.
Field Case, same customer. Similar experience
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 19
Test at Calibration Facility / Blockage
Significant error results from
small amounts of blockage
DIAGNOSTIC
No indication of process change
in the most advanced
Dynamic Flow Diagnostics -6,00
-5,00
-4,00
-3,00
-2,00
-1,00
0,00
1,00
100,00 70,00 50,00 40,00 20,00 10,00 3,00
Blockage Test 1 - Shift from Baseline (Primary vs Check Meter) H1 4 Path 2 Path Blockage Tests
-6,00
-5,00
-4,00
-3,00
-2,00
-1,00
0,00
1,00
100,00 70,00 50,00 40,00 20,00 10,00 3,00
Blockage Test 2 - Shift from Baseline (Primary vs Check Meter) H1 4 Path 2 Path
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 20
Test at Calibration Facility / Build Up
Significant error results from a small amount of buildup
DIAGNOSTIC
No indication of process change
in the most advanced
Dynamic Flow Diagnostics -1,00
-0,50
0,00
0,50
1,00
1,50
2,00
100,00 70,00 50,00 40,00 20,00 10,00 3,00
Buildup Test 5- Shift from Baseline (Primary vs Check Meter) H1 4 Path 2 Path
-1,00
-0,50
0,00
0,50
1,00
1,50
2,00
100,00 70,00 50,00 40,00 20,00 10,00 3,00
Buildup Test 6- Shift from Baseline (Primary vs Check Meter) H1 4 Path 2 Path
T5 T6
Buildup Tests
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 21
Conclusion
• We have seen that both Chordal or Reflective paths configuration have Pros and Cons.
• Combining them in a smart way provides added value :
– Detection of liquid / build up / contamination / blockage
– Easy to understand on line comparison versus “complex” diagnostics
• Daniel has combined these 2 contradictive technologies in a single meter body to enable wider usage of this method.
• Without compromising robust fiscal measurement, sensitivity has been added to detect metrological relevant process issues.
• Please come to our booth to discover these added values in a single gas meter.
[File Name or Event] • Emerson Confidential • 4/10/2016 • Slide 22
Thank you & acknowledgment
• Thanks to European Flow Measurement Workshop organisator
• Thanks to David Brown, Business Development Manager, Ultrasonic, Canada / Jacob Freeke, Director Marketing Ultrasonic, for their help preparing this presentation
• Thanks to our customer to use their field data
• Thanks to the audience for listening !