Replacement Parts List No. 700053600Revision C 02/2020
Daikin
PreciseLine™ Horizontal Large Capacity Blower Coil
BCHD006 - 020Design 1
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
![Page 2: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/2.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 2
ContentsParts List Revision History.................................................................................................................................. 3
Nomenclature Serial Number .............................................................................................................................................. 4 Model Number ........................................................................................................................................ 4 - 7
Electrical Legend ................................................................................................................................................ 7
Coils Section ...................................................................................................................................................... 8
Drain Pan & Drip Tray......................................................................................................................................... 8 Fan Housing & Wheel Assy .............................................................................................................................. 9 Electric Heat ............................................................................................................................................. 10 - 13
Controls ............................................................................................................................................................ 14
Damper ............................................................................................................................................................. 15
Field Installed Accessories ........................................................................................................................ 16 - 19
![Page 3: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/3.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 3
Rev. Date Description New 05/18 New. A 03/19 Pages 4, 6- Add Code 52: Motor Qty; Code 53: Fan Motor Horse Power; and Code 54: Labeling. Add Code 06:G=460V. Add Code 08:D= DX/R410A; Code15: G=Front; Code 20: B= Basic; Code 25: T= Top; Codes 29 & 35 add 3/8" & 1/2" options; Code31: 08= 8 Rows; Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580. Add 460V 1 HP motor p/n 910247105, and .add 460V 1/2 HP motor p/n 910247120. B 10/19 Pages 4-6 Code 15 delete G & H. Code 29 delete1/2" Coil Tube Diameter. Code 35 change 3S to Fan Motor Horse Power. Code 53 Add 1.5HP & 2HP. Add Code 55 B= Base Rail Pages 16-19 Add expansion valves for DX coils. C 02/20 Page 16: Changed titles for filter charts, was "Filter Kits". Corrected Qty on 4 inch Filters, was 12 pk.
Parts List Revision History
Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
![Page 4: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/4.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 4
Nomenclature
Year of Manufacture18= 201819= 2019
etc.
Serial NumberAUB U 18 03 03105
Plant Identification Serial Number (build sequence)
U= Unit
Week of Manufacture
Model NumberBC H D 010 1 E R W P L W A T T B P E1 A 001 D D
Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21
Code 01: Unit Type/Cabinet TypeBC= Daikin Blower Coil
Code 02: Unit ArrangementH= Horizontal
Code 03: Fan ArrangementD= Draw Thru Code 04: Model Size006= 600 CFM 016= 1600 CFM 008= 800 CFM 018= 1800 CFM 010= 1000 CFM 020= 2000 CFM 012= 1200 CFM
Code 05: Design Series1= 1st Vintage
Code 06: VoltageA= 115/60/1 P= 277/60/1E= 208/60/1 G= 460/60/1K= 230/60/1
Code 07: Primary Coil Connection LocationL= Left Hand (Air in the back of the head)R= Right Hand (Air in the back of the head)
Code 08: Primary Coil TypeD= DX/R410AW= Water/Glycol
Code 09: Secondary Coil LocationP= PreheatR= ReheatY= None
Code 10: Secondary Coil Connection LocationL= Left Hand (Air back of the head)R= Right Hand (Air back of the head)Y= None
Code 11: Secondary Coil TypeW= Hot Water/Glycol Y= None
Code 12: Corrosion PackageA= Coil Casing: SSTL/ FinCoat: None/ Drip Pan: SSTLY= Coil Casing: Galv/ FinCoat: None/ Drip Pan: Galv
Code 13: Mix Box OpeningsT= Top + Rear B= Bottom + RearY= No Mix Box
Code 14: Mix Box Actuator TypeT= On/OffA= 0-10V Mod M= ManualY= None
Code 15: Discharge Plenum OpeningB= BottomT= TopE= EndR= Right Hand (Air back of head)L= Left Hand (Air back of head)F= Field Cut-out (Plenum without Cut-Outs)Y= No Discharge Plenum
Continued on next page.
YYY S F 208 208 E6 12 02 YYY Y Y E6 12 01 YYY 1 1 M DCode 22 - 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
D Y Y T E B Y Y YYYY 1 C D BCode 43 44 45 46 47 48 49 50 51 52 53 54 55
SLP= San Luis PotosiSTN= Staunton
![Page 5: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/5.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 5
Code 16: Electric Heat LocationP= PreheatY= None
Code 17: Electric Heat StagesE1= PreheatSS= SCRYY= None
Code 18: Electric Heat Power SupplyA= 115/60/1 P= 265/60/1E= 208/60/1 T= 460/60/1K= 230/60/1 Y= None
Code 19: Electric Heat Size00A= 0.5 kW 006= 6.0 kW 013= 13.0 kW001= 1.0 kW 008= 8.0 kW 015= 15.0 kW002= 2.0 kW 009= 9 kW 018= 18.0 kW003= 3.0 kW 010= 10 kW 020= 20.0 kW004= 4.0 kW 011= 11 kW YYY= None005= 5.0 kW 012= 12 kW
Code 20: Primary (Cooling) Coil - Piping PackageB= Basic (No strainer and no circuit setter) D= Deluxe (Includes strainer and circuit setter)N= No PipingY= None
Code 21: Secondary (Heat) Coil - Piping PackageB= Basic (No strainer and no circuit setter) D= Deluxe (Includes strainer and circuit setter)N= No PipingY= None
Codes 22 - 24: YYYExtended Warranty, Production Type (Delivery), Special Unit Options (Consult code string for Special Options description)
Code 25: Filter AccessS= SideB= BottomT= Top
Code 26: Filter ArrangementF= FlatY= None
Code 27: First Filter (Furthest Filter Upstream if 2 filters selected)204= 2" Filter, MERV 4208= 2" Filter, MERV 8 213= 2" Filter, MERV 13404= 4" Filter, MERV 4408= 4" Filter, MERV 8 413= 4" Filter, MERV 13YYY= No Filter
Code 28: Second Filter204= 2" Filter, MERV 4208= 2" Filter, MERV 8 213= 2" Filter, MERV 13YYY= No Filter
Model NumberContinued
Code 29: Primary (Cooling) Coil Tube 3/8" Diameter3B= Water Coil, 1 Circuit3C= Water Coil, 2 Circuit3S= Water Coil, Single Serpentine3D= Water Coil, Double Serpentine3H= Water Coil, Half Serpentine3Q= Water Coil, Quarter Serpentine3L= Water Coil, Three Quarter Serpentine3M= Water Coil, One And One Half Serpentine3N= DX, Single Circuiting3J= DX, Interlaced Circuiting
Code 30: Primary (Cooling) Coil Fin Density 12= 12 FPI16= 16 FPI
Code 31: Primary (Cooling) Coil Tube Rows02= 2 Rows 06= 6 Rows04= 4 Rows 08= 8 Rows
Code 32: Primary Coil Valve2CL= 2-Way Valve, Closed, 24V- EOC2YP= 2-Way Valve, No Position, 0-10v- Mod2PL= 2-Way Valve, Open, 24V- EOC3CL= 3-Way Valve, Closed, 24V- EOC3YP= 3-Way Valve, No Position, 0-10v- Mod3PL= 3-Way Valve, Open, 24V- EOCYYY= None
Code 33: Primary Coil Valve Cv1= 0.3 A= 142= 0.46 B= 163= 0.8 C= 194= 1.2 D= 245= 1.9 E= 256= 3 F= 297= 4.7 G= 308= 7.4 Y= None9= 10
Code 34: Primary Coil Valve GPM1= 0.5 A= 5 J= 122= 1 B= 5.5 K= 13 3= 1.5 C= 6 L= 144= 2 D= 7 M= 155= 2.5 E= 8 Q= 18 6= 3 F= 9 S= 207= 3.5 G= 10/10.5 V= 258= 4 H= 11 W= 309= 4.5 Z= Manual Circuit Setter Y= None
Code 35: Secondary (Heating) Coil Tube 3/8" Dia.3B= Water Coil, 1 Circuit3C= Water Coil, 2 Circuit3S= Fan Motor Horse Power3D= Water Coil, Double Serpentine3H= Water Coil, Half Serpentine3Q= Water Coil, Quarter Serpentine3L= Water Coil, Three Quarter Serpentine3M= Water Coil, One And One Half Serpentine3N= DX, Single Circuiting3J= DX, Interlaced Circuiting
Continued on next page.
![Page 6: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/6.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 6
Code 36: Secondary (Heating) Coil Fin Density 12= 12 FPI16= 16 FPI
Code 37: Secondary (Heating) Coil Tube Rows01= 1 Row02= 2 RowsYY= None
Code 38: Secondary Coil Valve2CL= 2-Way Valve, Closed, 24V- EOC2YP= 2-Way Valve, No Position, 0-10v- Mod2PL= 2-Way Valve, Open, 24V- EOC3CL= 3-Way Valve, Closed, 24V- EOC3YP= 3-Way Valve, No Position, 0-10v- Mod3PL= 3-Way Valve, Open, 24V- EOCYYY= None
Code 39: Secondary Coil Valve Cv1= 0.3 A= 14 N= 702= 0.46 B= 16 P= 753= 0.8 C= 19 Q= 854= 1.2 D= 24 R= 1105= 1.9 E= 25 S= 1206= 3 F= 29 T= 1307= 4.7 G= 30 U= 1508= 7.4 H= 37 V= 1709= 10 J= 46 W= 210 K= 57 X= 240 L= 60 Y= None M= 65Code 40: Secondary Coil Valve GPM1= 0.5 A= 5 J= 122= 1 B= 5.5 K= 13 3= 1.5 C= 6 L= 144= 2 D= 7 M= 155= 2.5 E= 8 Q= 18 6= 3 F= 9 S= 207= 3.5 G= 10/10.5 V= 258= 4 H= 11 W= 309= 4.5 Z= Manual Circuit Setter Y= None
Code 41: Air VentsM= ManualCode 42: Unit Disconnect SwitchD= Disconnect Switch - ToggleF= Disconnect with Fusing
Model NumberContinued
Code 43: Mounted ControllerD= Digital Controls Ready/ Low Voltage Terminal Strip
Code 44: Local User Controller CommunicationY= None
Code 45: Thermal Zone Control SchemeY= None
Code 46: Motor ControlT= Three SpeedM= 0-10V Modulating
Code 47: Overflow Switch & Changeover/Pipe SensorE= Overflow Switch/ No Changeover/Pipe SensorY= None
Code 48: Freezestat and Smoke DetectionB= Freezestat/ No Smoke Detection Y= None
Code 49: Cabinet ExteriorB= Daikin BeigeY= None
Code 50: Sound PackageD= Discharge PlenumY= None
Code 51: Fan SpeedYYYY= None
Code 52: Motor Qty1= 1 Single Shaft Motor2= 2 Single Shaft Motors
Code 53: Fan Motor Horse PowerB= 1/3 HP D= 3/4 HPC= 1/2 HP E= 1 HP
Code 54: LabelingD= Daikin AppliedP= Price Industries
Code 55: Base RailB= Base Rail Included
![Page 7: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/7.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 7
Electrical Legend
ACT Mixing Box Damper Actuator
COS Condensate Overflow Switch/Sensor
DAT Discharge Air Temperature Sensor
DS1 Disconnect Switch
EB MicroTech III I/O Expansion Board
EWT Entering Water Temperature
FM1-2 Fan Motor
FRZ Freeze Alarm Switch
FSW Fan 3-Speed Switch
HTR1-4 Electric Heater Elements
LVB Low Voltage Control Board
MIII MicroTech III Control Board
MMP Manual Motor Protector
NCB Network Communication Board
OAT Outside Air Temperature Sensor
OHA Automatic High Temp Cutout Switch
OHM Manual High Temp Cutout Switch
PB1 Main Power Distribution Block- Single Phase
PB1 3PH Main Power Distribution Block- Three Phase
TB2 24V Power
TB4 Fan, Valve, Actuator Control
TB12 24V Sensor and Switch Control
TB6 No Controls Terminal Block
RAT Return Air Temperature Sensor
R1-2 Electric Heater Power Relay
R3 Electric Heater Control Relay
SCR Silicone Control Rectifier
SSR Solid State Relay
TS1-2 Thermal Switch (Intermediate Electric Heat)
TS3 Thermal Switch (Automatic Change Over)
TR Control Transformer
VFD Variable Frequency Drive
VSV1-2 Coil Valve Actuator (Primary or Secondary)
![Page 8: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/8.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 8
Coil Section
Primary SupplySecondary Return (Optional)
Primary ReturnSecondary Supply (Optional)
Drain
Coil connectionsLeft hand drive side shown,
right hand drive side connections same as left
but opposite.
Drain PanDescription Unit Size Metal Left Hand Right HandCondensate Drain Pan Assy with Drain Tube 006 SSTL 263584144 263584137Condensate Drain Pan Assy with Drain Tube 008 SSTL 263584145 263584143Condensate Drain Pan Assy with Drain Tube 010, 012 SSTL 263584146 263584136Condensate Drain Pan Assy with Drain Tube 016 SSTL 263584147 263584138Condensate Drain Pan Assy with Drain Tube 018 SSTL N/A 263584150Condensate Drain Pan Assy with Drain Tube 020 SSTL 263584148 263584139
Description Code 12 Unit Size Left Hand Right HandDrip Pan, Galv. Y
006910224371 910224406
Drip Pan, SSTL A 910217886 910217820Drip Pan, Galv. Y
008910224408 910224420
Drip Pan, SSTL A 910220513 910220529Drip Pan, Galv. Y
010, 012910224421 910224427
Drip Pan, SSTL A 910220568 910220563Drip Pan, Galv. Y
016910224430 910224439
Drip Pan, SSTL A 910220586 910220612Drip Pan, Galv. Y
018, 020910224443 910224444
Drip Pan, SSTL A 910213910 910217261
Drip Tray
N/A= Not Applicable
Note:Please contact Daikin with unit model and serial number for coil part numbers.
![Page 9: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/9.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 9
135134
Ref.No. Description Part
NumberUnit Size
006 008 010 012 016 018 020132 Blower Housing & Wheel Assy 910210867 1 1 1 1 2 2 2134 Band, Motor Mount 910121966 1 1 1 1 2 2 2135 Arm, Motor Mount 910163977 4 4 4 4 8 8 8
163
ECM Motor, 1/3 HP 115/230/265V 910218048 1 1 2
ECM Motor, 1/2 HP115/230/265V 910218049 1 1 1 1 2 2 2
460V 910247120 1 1 1 1 2 2 2ECM Motor, 3/4 HP 115/208/230/265V 910218052 1 1 1 1 2 2 2
ECM Motor, 1 HP115/230/265V 910234580 1 1 2 2 2
460V 910247105 1 1
163
132
Motor Mount Detail
See Motor Mount Detail
Fan Housing & Wheel AssyECM Motor
Note: Motor sizes 016, 018, & 020 have a total of 2 motors per unit. For motor part number refer to the Data Plate on unit or BOM Search in Distributor Tools.
![Page 10: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/10.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 10
Auto & Manual Temp Reset Switch
Unit Size Voltage KilowattsTemperature Reset Switch
Auto (OHA) Manual (OHM)006 ALL ALL
910118165 910118166
008
115, 208/230 0.5, 1, 2, 3 265/277 0.5, 1, 2, 3, 4, 5
115 4, 5668911811 668911911208/230 4, 5, 6, 8, 10
265/275 6, 8, 10010 - 020 ALL ALL 668911811 668911911
Electric Heat Control
Ref.No. Description
Unit SizeQty.
006 008 010, 012 016 018, 020
145Contactor, DPST, 30A 106500102 106500102 106500102 106500102 106500102 1Contactor, DPST, 60A 910216977 910216977 910216977 910216977 910216977 1
150Relay, SCR Control, 25A 910217042 910217042 910217042 910217042 910217042 1Relay, SCR Control, 50A 910217007 910217007 910217007 910217007 910217007 1
187 Limit Switch, 15A 910225956 910225956 910225956 910225956 910225956 1
Electric Heat
150 SCR
OHM
OHA
145 187
Heat Sink AssyDetail
see Heat Sink AssyDetail
![Page 11: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/11.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 11
Electric HeatContinued
Heater Elements Size 006
Unit Size Unit Voltage Total kWElement 1 Element 2
kW Part Number kW Part Number
006
115/60/1
0.5 0.5 910121029
N/A N/A1.0 1 9101210302.0 2 9102264323.0 3 9102264314.0 2 910226432 2 910226432
208/230/60/1
0.5 0.5 910121039
N/A N/A1.0 1 9101210402.0 2 9101210423.0 3 9101213574.0 2 910121042 2 9101210425.0 3 910121357 2 9101210426.0 3 910121357 3 910121357
265/277/60/1
0.5 0.5 910121049
N/A N/A
1.0 1 9101210502.0 2 9101210523.0 3 9101213584.0 2 9102014035.0 3 9102264196.0 3 910121358 3 910121358
1 Bank 4 Bank2 Bank Horizontal 2 Bank Vertical
Heater Arrangements
![Page 12: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/12.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 12
Electric HeatContinued
Heater Elements Sizes 008 - 012
Unit Size Unit Voltage Total kWElement 1 Element 2
kW Part Number kW Part Number
008thru012
115/60/1
0.5 0.5 910121029
N/A N/A1.0 1 9101210302.0 2 9102264323.0 3 9102264314.0 2 910226432 2 9102264325.0 3 910226431 2 910226432
208/230/60/1
0.5 0.5 910121039
N/A N/A1.0 1 9101210402.0 2 9101210423.0 3 9101213574.0 2 910121042 2 9101210425.0 3 910121357 2 9101210426.0 3 910121357 3 9101213578.0 4 910226430 4 91022643010.0 5 910226429 5 910226429
265/277/60/1
0.5 0.5 910121049
N/A N/A
1.0 1 9101210502.0 2 9101210523.0 3 9101213584.0 2 9102014035.0 3 9102264196.0 3 910121358 3 9101213588.0 4 910201403 4 91020140310.0 5 910226419 5 910226419
![Page 13: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/13.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 13
Heater Elements Sizes 016 - 020
Unit Size Unit Voltage TotalkW
Element 1 Element 2 Element 3 Element 4kW P/N kW P/N kW P/N kW P/N
016 thru020
115/60/1
1.0 0.5 910121029 0.5 910121029
N/A N/A N/A N/A2.0 1 910121030 1 9101210304.0 2 910226432 2 9102264325.0 3 910226431 2 910226432
016thru020 208/230/60/1
1.0 0.5 910121039 0.5 910121039
N/A N/A N/A N/A
2.0 1 910121040 1 9101210404.0 2 910121042 2 9101210426.0 3 910121357 3 9101213578.0 4 910226430 4 91022643010.0 5 910226429 5 910226429
018, 020 11.0 3 910121357 3 910121357 2 910121042 3 910121357
016thru020
265/277/60/1
1.0 0.5 910121049 0.5 910121049
N/A N/A N/A N/A
2.0 1 910121050 1 9101210504.0 2 910121052 2 9101210526.0 3 910121358 3 9101213588.0 4 910201403 4 91020140310.0 5 910226419 5 91022641912.0 3 910121358 3 910121358 3 910121358 3 91012135813.0 3 910121358 3 910121358 3 910121358 4 910201403
Electric HeatContinued
Description 006 008 010, 012 016 018, 020 Qty.Grille Guard, 1 Bank 910222765 910219625 910219670
N/A N/A1
Grille Guard, 2 Bank, Vert. 910222766 910219627 910223156 1Grille Guard, 2 Bank, Horz.
N/A N/A N/A910236947 910236296 1
Grille Guard, 4 Bank 910219687 910223627 1
Grille Guard
Grille Guard
![Page 14: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/14.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 14
Controls
Ref.No. Description Part
Number Qty.
325Disconnect Switch, Non-Fusable, 100A 193444703 1Disconnect Switch, Non-Fusable, 60A 263940219 1Disconnect Switch, Non-Fusable, 30A 4EAL4022 1
355Transformer, 115V 910116204 1Transformer, 208/230V 910116202 1Transformer, 265/277V 910116203 1
460 Control Board, EVO, 4-Speed, Adj. 910160028 1465 Control Board, EVO, 2 Motor Control 910161413 1N/S Condensate Overflow Switch 106591001 1N/S Freezestat 4ELN9178 1
355
Low Voltage
Disconnect Switch, 30A
325
Disconnect Switch, 60A
325
Disconnect Switch, 100A
325
460
465
or or or
![Page 15: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/15.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 15
Damper
340
355364
330
Damper Assy with Actuator
Ref.No. Description
Unit SizeQty.
006 008 010, 012 016 018, 020330 Damper Blade 263920469 263920497 263920540 263920568 910212373 1
340Actuator Dir. Drive, On/Off 910222140 910222140 910222140 910222140 910222140 1
Actuator Dir. Drive, 0-10VDC 910222130 910222130 910222130 910222130 910222130 1355 Shaft 910208148 910208148 910208148 910208148 910208148 1362 Gasket, Blade, 1" 910127828 910127828 910127828 910127828 910127828 2 Ft.
364 Gasket, Channel, 1" 910127832 910127832 910127832 910127832 910127832 1 Ft.
Damper Assy - Mix Box
362
![Page 16: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/16.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 16
Replacement Filters- Main CabinetDescription
Qty.006 008 010, 012 016 018, 020
Unit Quantity 1 1 2 2 22" Filter, MERV 4* 12 pack 910214573 910215287 910217130 910217141 910214578
2" Filter, MERV 8* 12 pack 910214385 910215290 910217135 910217142 9102145322" Filter, MERV 13* 12 pack 910214661 910215291 910217136 910217143 9102146754" Filter, MERV 8 6 pack 910214549 910215294 910217138 910217162 9102145604" Filter, MERV 13 6 pack 910214718 910215296 910217139 910217164 910214723
* For second filter use only the 2" filter. First filter is furthest filter upstream if 2 filters are selected.
Field Installed Accessories
Replacement Filters - Mix BoxDescription
Qty.006 008 010, 012 016 018, 020
Unit Quantity 1 1 1 2 22" Filter, MERV 4 12 pack 263921271 263921279 263921287 263921295 263946061
2" Filter, MERV 8 12 pack 263921273 263921281 263921289 263921297 2639213052" Filter, MERV 13 12 pack 263921275 263921283 263921291 263921299 2639213074" Filter, MERV 8 6 pack 263921274 263921282 263921290 263921298 2639213064" Filter, MERV 13 6 pack 263921276 263921284 263921292 263921300 263921308
Note: The standard filter rack can accommodate one 2", one 4", or two 2" filters in a side or bottom access configuration.
Description UnitSize
PartNumber
Expansion Valve, Adjustible 06 263922461Expansion Valve, Adjustible 08 263922462Expansion Valve, Adjustible 10, 12 263922465Expansion Valve, Adjustible 16 263922466Expansion Valve, Adjustible 18, 20 263922468
Expansion Valve for DX Coils
Description PartNumber
Digital Changeover Assembly, 10K * 910236380
Changeover Switch Kit
* EWT Sensor p/n 107201601 included in assembly.
![Page 17: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/17.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 17
Thermostats
Description PartNumber
Digital, 24/115-277V, 2 Pos Valve, Staged Fan 107345336Digital, 24/115-277V, 3 Speed, 2 Pos Valve, Valve Control or Fan Cycle 107345335Digital, 2 or 4 Pipe, 24 Volt, 2 Pos Valve or 3 Wire Mod, 3 Speed Switch, ACO 107345301Digital, 2 or 4 Pipe, 24V, 2 Pos or 3 Wire Mod Valve 107345245Digital, 2 or 4 Pipe, 24V Proportional Valve 107014411Digital, 2 or 4 Pipe, 24V Proportional Valve, 3-Speed Switch 107014412Remote Return Air Sensor- 60" Lead (used with 107014411) 107345501TStat, 2 Pipe, No Speed Switch, 2 Pos Valve, Heat/Cool, MCO 107345303TStat, 2 or 4 Pipe, 3 Speed Switch, 2 Pos Valve, Heat/Cool, MCO 107345302TStat, 2 or 4 Pipe, 3 Speed Switch, 2 Pos Valve, Heat/Cool, ACO 107345304TStat, 2 or 4 Pipe, No Speed Switch, 2 Pos Valve, Heat/Cool, ACO 107345305Digital, T-Stat, 7 Day, 4 Event Programmable, 24/115-277V, 3 Speed Fan Control 910119110Digital, T-Stat, 7 Day, 4 Event Programmable, 24/115-277V, Staged Fan Control 910119111T-Stat, Fan Coil BACnet (Low Voltage only) 250803500
Field Installed Accessories Continued
![Page 18: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/18.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 18
Field Installed Accessories Continued
Valve Package- ON/OFF & Modulating Valve
SizeControl Off
Position Cv 2-WayValve
3-WayValveType Voltage
0.625On/Off 24V Normally
Open
1.9 B211 263940304 B311 26394030016 B216 263940305 B316 263940301
0.875 24 B221 263940306 B321 2639403021.125 30 B225 263940307 B325 263940303
0.625On/Off 24V Normally
Closed
1.9 B211 263940312 B311 26394030816 B216 263940313 B316 263940309
0.875 24 B221 263940314 B321 2639403101.125 30 B225 263940315 B325 263940311
0.625
Modulating 1-10VDC None
0.3 B207 263940901 B307 2639405010.46 B208 263940902 B308 2639405020.8 B209 263940903 B309 2639405031.2 B210 263940904 B310 2639405041.9 B211 263940905 B311 263940505
Modulating 1-10VDC None
3 B212 263940906 B312 2639405064.7 B213 263940907 B313 26394050710 B215 263940908 B315 26394050816 B216 263940909 B316 263940509
0.875 Modulating 1-10VDC None
4.7 B217 263941001 B317 2639406017.4 B218 263941002 B318 26394060214 B220 263941003 B320 26394070124 B221 263941101 B321 263940702
1.125 Modulating 1-10VDC None7.4 B222 263941201 B322 26394080110 B223 263941202 B323 26394080230 B225 263941203 B325 263940803
DescriptionValve Size
1/2" 3/4" 1"Autoflow Valve with Strainer, 5.5 Cv 263940136 N/A N/AAutoflow Valve with Strainer, 9Cv N/A 263940135 N/AAutoflow Valve with Strainer, 9Cv N/A N/A 263940137
Valve Package- Autoflow Valve with Strainer
![Page 19: Daikin PreciseLine™ Horizontal Large Capacity …...Codes 34 & 40: Z= Manual Circuit Setter; Code 036: 16= 16FPI. Page 9- Update motors to Daikin Tools. Add 1 HP motors p/n 910234580](https://reader030.vdocuments.us/reader030/viewer/2022040116/5eb6fa8b719d100510217241/html5/thumbnails/19.jpg)
Fan Coil, BCHD 006-020 Design 1 Rev. C 02/20 RPL 7000536 /Page 19
Description GPMValve Size
1/2" 3/4"Autoflow Valve, Shutoff, 14 Cv 0.5 263578301 263578401Autoflow Valve, Shutoff, 14 Cv 0.75 263578302 263578402Autoflow Valve, Shutoff, 14 Cv 1 263578303 263578403Autoflow Valve, Shutoff, 14 Cv 1.5 263578304 263578404Autoflow Valve, Shutoff, 14 Cv 2 263578305 263578405Autoflow Valve, Shutoff, 14 Cv 2.5 263578306 263578406Autoflow Valve, Shutoff, 14 Cv 3 263578307 263578407Autoflow Valve, Shutoff, 14 Cv 3.5 263578308 263578408Autoflow Valve, Shutoff, 14 Cv 4 263578309 263578409Autoflow Valve, Shutoff, 14 Cv 4.5 263578310 263578410Autoflow Valve, Shutoff, 14 Cv 5 263578311 263578411Autoflow Valve, Shutoff, 14 Cv 5.5 263578312 263578412Autoflow Valve, Shutoff, 14 Cv 6 263578313 263578413Autoflow Valve, Shutoff, 14 Cv 7 263578314 263578414Autoflow Valve, Shutoff, 14 Cv 8 263578315 263578415Autoflow Valve, Shutoff, 14 Cv 9 263578316 263578416Autoflow Valve, Shutoff, 14 Cv 10.5 263578317 263578417Autoflow Valve, Shutoff, 14 Cv 11 263578318 263578418Autoflow Valve, Shutoff, 14 Cv 12 263578319 263578419
Field Installed Accessories Continued
Valve Package- Autoflow Valve 1/2" & 3/4"
Description GPMValve Size
1"Autoflow Valve, Shutoff, 32Cv 7 263578501Autoflow Valve, Shutoff, 32Cv 8 263578502Autoflow Valve, Shutoff, 32Cv 9 263578503Autoflow Valve, Shutoff, 32Cv 10 263578504Autoflow Valve, Shutoff, 32Cv 15 263578505Autoflow Valve, Shutoff, 32Cv 18 263578506Autoflow Valve, Shutoff, 32Cv 20 263578507Autoflow Valve, Shutoff, 32Cv 25 263578508Autoflow Valve, Shutoff, 32Cv 30 263578509
Valve Package- Autoflow Valve 1"