HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
ISTA 6 - Amazon.com – SIOC - H Test Report_External VERSION DATE: 5/9/2018
ITEM INFORMATION
Vendor/Seller Name: Hisense Visual Technology Co.,Ltd.
ASIN: Click here to enter text.
Item: HU70A6109FUWA, 70H6570G, 70H6510G
Certification Passed:
☐ Pass / Frustration Free Packaging (FFP)
☒ Pass / Ships in Own Container (SIOC)
☐ Fail / Enforced Over Box (EOB)
LAB INFORMATION
Testing Lab: Hisense Visual Technology Co.,Ltd.
Location: Laoshan District of Qingdao,Shandong,China
Date of Test: 5/1/2020
ISTA Member/ Lab Tech: Signed for and on behalf of Hisense Visual Technology Co.,Ltd.
FengLei Liu Approved signatory
TEST RESULTS
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
Tested Item Summary
Number of Samples Tested Number of Samples Passed Number of Samples Failed
2 2 0
Post Test Comments:
Overview The package Passed the packaging test criteria with no visible damage noted per ISTA 6-Amazon.com-SIOC-Type H.
Product Condition
All components from TV inside the carton box were not damaged after testing. And no function abnormality on the product.
Packaging Condition
The packaging materials inside the carton box are not damaged after testing.
LAB TEST REQUEST {filled out by requestor}
Test Requestor Hisense Visual Technology Co.,Ltd. Project Name ISTA 6-Amazon.com-SIOC:2018-Type H
Submission Date 5/6/2020 Due Date 5/9/2020
ASIN Manufacturer Description -- HISENSE LCD TV PACKAGE PRODUCT
Package Dimension Catalog Dims / Actual measured by lab:69-1/2”L X 8-1/3”W X 42-1/3” H and 170.75”
Package Weight Catalog Weight / Actual weight by lab:66.15lb
Classification 1 SIOC
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
Classification 2 Parcel
Test Type ISTA 6 –Amazon.com SIOC - H
Fragile/Non-Fragile Non-Fragile Value Add Packaging
(VAP) Yes
Value Add Packaging (VAP) Info
Material specifications: Corrugated / Foam / Paper / Film
Total Test Samples 2 units
Additional Notes N/A
PRE-TEST INSPECTION {filled out by lab}
Product Condition Package was not opened before testing to review product.
Package Condition Package was not opened before testing and the carton box was in good condition.
Package Condition before testing
☒ ORIGINAL as arrived in the lab for testing
☐ NEW re-packaged with new materials before testing
Corrugated Info (Box Cert if available)
No Box Cert
Dunnage Info N/A
Additional Notes N/A
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
PRE-TEST PICTURES
Six sides of the ASIN package should be numbered and photographed. If a box cert is present it should be taken and recorded. Isometric picture views should be taken as called out below. Pictures of special call outs and or damage should have description of location and detailed information in the text box below the picture.
Side 1 Side 2 Side 3
Side 4 Side 5 Side 6
Box Cert (If Applicable) ISO #1 Side 1/2/5 ISO #2 Sides 3/4/6
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
TEST DETAIL
Items in black were completed and values updated. Items left in gray were not completed.
Test Value P/F P/F P/F P/F P/F OBSERVATIONS
BLOCK 1:Temp and Humidity
23℃ 43%RH
Ambient Lab Temp 12+ hours
BLOCK 3: Tip/Tip Over NA NA NA NA NA NA
BLOCK 4: Free-Fall Drops 12in&18 in P P NA NA NA
BLOCK 5: Rotational FLAT Drop NA NA NA NA NA NA
BLOCK 6: Rotational EDGE Drop NA NA NA NA NA NA
BLOCK 8: Inclined or Horizontal Impact NA NA NA NA NA NA
BLOCK 9: Compression 800lb P P NA NA NA
BLOCK 10: Clamping Simulation 476.8lb P P NA NA NA
BLOCK 13: Vib with Top Load Face 3 130lb P P NA NA NA
BLOCK 13: Vib with Top Load Face 4 600lb P P NA NA NA
BLOCK 13: Vib with Top Load Face 6 46lb P P NA NA NA
BLOCK 16: Free-Fall Drops 18in&32 in P P NA NA NA
BLOCK 20: Inclined or Horizontal Impact NA NA NA NA NA NA
BLOCK 22: Full Rotational Flat Drop Pass P P NA NA NA Screen Face
BLOCK 24: Concentrated Edge Impact 16in P P NA NA NA Screen Face ***DO NOT CATCH APPLIES TO ALL SHOCK and TIP TESTS***
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
TEST PICTURES
Pictures should be taken of each block test set up along with a post picture taken of the item at the end of each test block. Additional pictures of damage should have locations noted, size of damages measured, and written in text box below them.
Block 4 Free-Fall Drops Test Set Up Block 4 Free-Fall Drops Post Test Item
Picture Extra #
Block 9 Compression Horizontal Test Set
Up Block 9 Compression Horizontal Post
Test Item Picture Extra #
Block 10 Compression Vertical Test Set
Up Block 10 Compression Vertical Post Test
Item Picture Extra #
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
TEST PICTURES {continued}
Block 13 FACE 3 Test Set Up Block 13 FACE 3 Post Test Item Picture FACE 3 Test Vibration Profile
Block 13 FACE 4 Test Set Up Block 13 FACE 4 Post Test Item Picture FACE 4 Test Vibration Profile
Block 13 FACE 6 Test Set Up Block 13 FACE 6 Post Test Item Picture FACE 6 Test Vibration Profile
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
TEST PICTURES {continued}
NA
Block 16 Free-Fall Drops Test Set Up Block 16 Free-Fall Drops Post Test Item Picture
Extra #
NA
Block 22 Full Rotational Flat Drop Test Set Up
Block 22 Full Rotational Flat Drop Post Test Item Picture
Extra #
NA
Block 24 Concentrated Edge Impact Test Set Up
Block 24 Concentrated Edge Impact Post Test Item Picture
Extra #
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
POST TEST PICTURES
Isometric views of the box should be taken as called out in first two picture spots. An exploded bill of material (BOM) view should be added to the third slot. Additional pictures of damage should have locations noted, size of damages measured, and written in text box below them.
Extra #1-16
ISO #1 Side 1/2/5 ISO #2 Sides 3/4/6 Exploded BOM View
Extra #01 Extra #02 Extra #03
Extra #04 Extra #05 Extra #06
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
TEST PICTURES {continued}
Extra #07 Extra #08 Extra #09
Extra #10 Extra #011 Extra #12
Extra #13 Extra #14 Extra #15
HISENSE Internal Doc ID #:2020-05-A20 Date:May.9,2020
Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf.
Attention is drawn to the limitation of liability, indemnifications and jurisdiction issues defined therein. Any holder of this document is
advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of
Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction
from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without
prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer
only to the sample(s) tested and such sample(s) are retained for 30 days only.
Attention: To check the authenticity of testing / inspection report & certificate, please contact us at telephone:(86-0532)55753011 or email:
399 Song Ling, Qingdao, 266100, China 中国·山东·青岛市崂山区松岭路 399 号 A5 楼一楼 邮编:266100 电话:(86-0532)55753011 邮箱:[email protected]
TEST PICTURES {continued}
END OF REPORT