  • 8/13/2019 CX4 Series Arrays

    1/67

    DELL|EMC CX 4 Series Training

  • 8/13/2019 CX4 Series Arrays

    2/67

  • 8/13/2019 CX4 Series Arrays

    3/67

    Overview

    This training is delivered as a blended learning course

    Web based blended learning Interactive Simulations Video demonstrations Remote access to equipment

    Additional information is available in the accompanyingweb pages

  • 8/13/2019 CX4 Series Arrays

    4/67

    CX4 Series Storage Array range

    4 Enclosures CX4-120c CX4-240c CX4-480c CX4-960c

    CX4 = Fourth generation of Hardware

    In a similar way to the previous release of CXhardware the last 3 digits indicate the maximumamount of connected drives

  • 8/13/2019 CX4 Series Arrays

    5/67

    New Features

    Flexports Modular Front end port configurations

    Greater Resilience GWCA (Greater Write Cache Availability)

    Up to 960 Drives64 bit operating system

    IPV6 capability

  • 8/13/2019 CX4 Series Arrays

    6/67

    Cache

    Greater Write Cache AvailabilityTwo Independent Features Persistent Memory

    Cache retained through Storage Processor restarts Recovery algorithms obtain last valid write cache data

    Enhanced Performance Increased Write cache Write cache enabled in degraded mode

    Restarts, NDUs etc.

  • 8/13/2019 CX4 Series Arrays

    7/67

    Write Cache 2U Chassis

    Fault Write Cache Comment

    Single PSU / Blower ON CX4-120/240/480

    PSU/Blower 1 on each side ON HW is still HA

    PS/ Blower 2 on the sameside

    ON SP Powered off

    Single SPS (CX4-120 with 2SPS)

    ON Due to any AC lossDue to SPS commsloss

    Single SPS CX4-120 (withoutoptional dual SPS)

    OFF Due to AC loss orSPS comms loss

  • 8/13/2019 CX4 Series Arrays

    8/67

    Flare

    One single Flare Bundle for all Reduce confusion

    Code enumeration for release28 04.28.000.x.xxx.

  • 8/13/2019 CX4 Series Arrays

    9/67

    Power Requirements

    2U Chassis operate on 110V or 240v CX4-120 / 240 and 480

    4U Chassis operate on 240v only CX4-960

    Care must be taken in allocating power

  • 8/13/2019 CX4 Series Arrays

    10/67

  • 8/13/2019 CX4 Series Arrays

    11/67

    Family Overview CX4 240c

    Two 1.6 Ghz Dual Core CPUs4GB Memory per SPMax 256 HA Hosts

    Up to 1024 LUNsUp to 240 Drives4 Power Supplies

  • 8/13/2019 CX4 Series Arrays

    12/67

    Family Overview CX4 480c

    Two 2.2 Ghz Dual Core CPUs8GB Memory per SPMax 256 HA Hosts

    Up to 4096 LUNsUp to 480 Drives4 Power Supplies

  • 8/13/2019 CX4 Series Arrays

    13/67

    Family Overview CX4 960c

    Two 2.33 Ghz Quad Core CPUs16GB Memory per SPMax 512 HA Hosts

    Up to 4096 LUNsUp to 960 Drives2 Power Supplies

  • 8/13/2019 CX4 Series Arrays

    14/67

    Select your training path

    2U CHASSIS

    4U CHASSIS

  • 8/13/2019 CX4 Series Arrays

    15/67

    CX 4 960

  • 8/13/2019 CX4 Series Arrays

    16/67

    Identification

    4U Chassis Similar to theCX3-80

    3 Layers of components

    I/O Annex at the bottom

    SPA in the centre

    SPB at the top

  • 8/13/2019 CX4 Series Arrays

    17/67

  • 8/13/2019 CX4 Series Arrays

    18/67

    Power Supplies

  • 8/13/2019 CX4 Series Arrays

    19/67

    Blowers

  • 8/13/2019 CX4 Series Arrays

    20/67

    SFPs

  • 8/13/2019 CX4 Series Arrays

    21/67

    Management Modules

  • 8/13/2019 CX4 Series Arrays

    22/67

    I/O Annex

  • 8/13/2019 CX4 Series Arrays

    23/67

  • 8/13/2019 CX4 Series Arrays

    24/67

    Memory

  • 8/13/2019 CX4 Series Arrays

    25/67

    I/O Modules

  • 8/13/2019 CX4 Series Arrays

    26/67

    iSCSI Module

    2 Ports per I/O Module

    10/100/1000 Ethernet

    Individual link and activitylights

    Integrated TOE (TCP/IPoffload engine)

  • 8/13/2019 CX4 Series Arrays

    27/67

    FC Module

    4 Fibre Channel PortsPersisted (Pre-configured) inthe factory at time ofmanufacture

    Additional modules can bepurchased as an upgrade andhave the followingconfigurations 4 Front end ports 4 Backend ports 2 Front and 2 Backend

    ports

    NST is used to configureModules and ports

  • 8/13/2019 CX4 Series Arrays

    28/67

    I/O Module Layout

  • 8/13/2019 CX4 Series Arrays

    29/67

  • 8/13/2019 CX4 Series Arrays

    30/67

    I/O Modules

    I/O Modules in each Storage Processor must match

    Location of SFPs in each Storage Processor mustmatch (Back-end Ports and Front-end Ports)

    I/O Modules can be added with Data in Place Utilizes NST wizard to install and configure modules

    Once a port is added and persisted it cannot bechanged

  • 8/13/2019 CX4 Series Arrays

    31/67

    Replacing an I/O Module

    I/O Modules are not hot pluggable Use CLI to shutdown the affected SP

    Naviseccli h -user -password

    -scope 0 shutdownsp Make note of labels and remove all FE and BE Cables Replace the I/O Module

    Reboot the SP

    Use CLI pointed to the running SP Naviseccli h -user -password

    -scope 0 rebootpeersp Verify operation in Navisphere Reconnect all cables into correct locations

  • 8/13/2019 CX4 Series Arrays

    32/67

    Power Supply 2U Chassis

  • 8/13/2019 CX4 Series Arrays

    33/67

    Power Supply distribution 2U Chassis

    SPA is powered by A0 and A1

    SPB is powered by B0 and B1

  • 8/13/2019 CX4 Series Arrays

    34/67

    LED Codes

    Fault LED is a bi-color LED andindicates boot status

    Amber Hz = BIOS 1 Hz = POST 4 Hz = POST starting OSBlue Hz = OS Booted 1 Hz = FLARE Driver start 4 Hz = Flare Driver complete

    Power LED only = successful boot

  • 8/13/2019 CX4 Series Arrays

    35/67

  • 8/13/2019 CX4 Series Arrays

    36/67

    World Wide Names

    Port SPA WWN SPB WWN00 50:06:01: 60 :BB:20:02:07 50:06:01: 68 :BB:20:02:07

    01 50:06:01: 61 :BB:20:02:07 50:06:01: 69 :BB:20:02:07

    02 50:06:01: 62 :BB:20:02:07 50:06:01: 6A:BB:20:02:07

    03 50:06:01: 63 :BB:20:02:07 50:06:01: 6B:BB:20:02:0704 50:06:01: 64 :BB:20:02:07 50:06:01: 6C :BB:20:02:07

    05 50:06:01: 65 :BB:20:02:07 50:06:01: 6D :BB:20:02:07

    06 50:06:01: 66 :BB:20:02:07 50:06:01: 6E :BB:20:02:07

    07 50:06:01: 67 :BB:20:02:07 50:06:01: 6F :BB:20:02:0708 50:06:01: 60 :BB:2 4:02:07 50:06:01: 68 :BB:2 C:02:07

    09 50:06:01: 61 :BB:2 4:02:07 50:06:01: 69 :BB:2 C:02:07

    10 50:06:01: 62 :BB:2 4:02:07 50:06:01: 6A:BB:2 C:02:07

    11 50:06:01: 63 :BB:2 4:02:07 50:06:01: 6B :BB:2 C:02:07

  • 8/13/2019 CX4 Series Arrays

    37/67

    Port Numbering

    Ports are assigned as they are added to an enclosure Base ports will remain the same Additional ports will be numbered in the order they are

    added

    Physical Ports are displayed by Slot/PortLogical Ports are assigned as ports are persisted

    Port mapping can be found in Navisphere under portmanagement

  • 8/13/2019 CX4 Series Arrays

    38/67

    Identifying Ports

  • 8/13/2019 CX4 Series Arrays

    39/67

    Select your training path

    2U CHASSIS

    4U CHASSIS

  • 8/13/2019 CX4 Series Arrays

    40/67

    2U Family CX4 120 / 240 / 480

  • 8/13/2019 CX4 Series Arrays

    41/67

    Identification via Ports

    CX4-120 2 BE Ports (one Blanked

    off on each SP)CX4-240

    4 BE Ports (Two per SP)CX4-480 8 BE Ports (4 Per SP)

  • 8/13/2019 CX4 Series Arrays

    42/67

    Us

    Power SuppliesBlowersMemoryStorage ProcessorI/O ModulesSFPs

    Management Modules

  • 8/13/2019 CX4 Series Arrays

    43/67

    PSU/Blowers

  • 8/13/2019 CX4 Series Arrays

    44/67

    Storage Processor

  • 8/13/2019 CX4 Series Arrays

    45/67

    Memory

  • 8/13/2019 CX4 Series Arrays

    46/67

    SFPs

  • 8/13/2019 CX4 Series Arrays

    47/67

    Management Modules

  • 8/13/2019 CX4 Series Arrays

    48/67

    I/O Modules

  • 8/13/2019 CX4 Series Arrays

    49/67

    iSCSI Module

    2 Ports per I/O Module

    10/100/1000 Ethernet

    Individual link and activitylights

    Integrated TOE (TCP/IPoffload engine)

  • 8/13/2019 CX4 Series Arrays

    50/67

    FC Module

    4 Fibre Channel PortsPersisted (Pre-configured) inthe factory at time ofmanufacture

    Additional modules can bepurchased as an upgrade andhave the followingconfigurations 4 Front end ports 4 Backend ports 2 Front and 2 Backend

    ports

    NST is used to configureModules and ports

  • 8/13/2019 CX4 Series Arrays

    51/67

    CX4 120 Configurations

    I/O Module Slot Module type and Ports

    Slot 0 4Gb FC Module1 Back-end Port (0)2 Front-end Ports (2,3)Port 1 is disabled

    Slot 1 1Gb iSCSI Module

    2 front-end ports 0,1Slot 2 Optional 4 Gb Module (4 Front-end 0,1,2,3)

    OrOptional 2 Gb Module (0,1)

    Slot 3 Disabled

    Slot 4 Disabled

  • 8/13/2019 CX4 Series Arrays

    52/67

    CX4 240 Configurations

    I/O Module Slot Module type and Ports

    Slot 0 4Gb FC Module2 Back-end Port (0,1)2 Front-end Ports (2,3)

    Slot 1 1Gb iSCSI Module2 front-end ports 0,1

    Slot 2 Optional 4 Gb Module (4 Front-end 0,1,2,3)OrOptional 2 Gb Module (0,1)

    Slot 3 Optional 4 Gb Module (4 Front-end 0,1,2,3)OrOptional 2 Gb Module (0,1)

    Slot 4 Disabled

  • 8/13/2019 CX4 Series Arrays

    53/67

    CX4 480 ConfigurationsI/O Module Slot Module type and Ports

    Slot 0 4Gb FC Module2 Back-end Port (0,1)2 Front-end Ports (2,3)

    Slot 1 4Gb FC Module2 Back-end Port (0,1)2 Front-end Ports (2,3)

    Slot 2 1Gb iSCSI Module2 front-end ports 0,1

    Slot 3 Optional 4 Gb Module (4 Front-end 0,1,2,3)or Optional 2 Gb Module (0,1)

    Slot 4 Optional 4 Gb Module (4 Front-end 0,1,2,3)or Optional 2 Gb Module (0,1)

  • 8/13/2019 CX4 Series Arrays

    54/67

    I/O Modules

    I/O Modules in each Storage Processor must match

    Location of SFPs in each Storage Processor mustmatch (Back-end Ports and Front-end Ports)

    I/O Modules can be added with Data in Place Requires a service engagement Utilises NST wizard to install and configure modules

    Once a port is added and persisted it can not bechanged

  • 8/13/2019 CX4 Series Arrays

    55/67

    Location of Storage Processors

    Storage Processors are added and removed from frontof Storage systemLED Boot indicator in the front centre

    Port 80H LEDs visible through the SP release handles

  • 8/13/2019 CX4 Series Arrays

    56/67

    LED Codes

    Fault LED is a bi-color LED andindicates boot status

    Amber Hz = BIOS 1 Hz = POST 4 Hz = POST starting OSBlue Hz = OS Booted

    1 Hz = FLARE Driver start 4 Hz = Flare Driver complete

    Power LED only = successful boot

  • 8/13/2019 CX4 Series Arrays

    57/67

    Unsafe to remove LED

    Shown as a hand with a linethough itWhen lit (White) Persisting the Memory Vaulting the Cache Updating the Resume or

    Flashing Firmware status

    Do Not remove the SP when thissymbol is lit

  • 8/13/2019 CX4 Series Arrays

    58/67

    World Wide Names

    Port SPA WWN SPB WWN00 50:06:01: 60 :BB:20:02:07 50:06:01: 68 :BB:20:02:07

    01 50:06:01: 61 :BB:20:02:07 50:06:01: 69 :BB:20:02:07

    02 50:06:01: 62 :BB:20:02:07 50:06:01: 6A:BB:20:02:07

    03 50:06:01: 63 :BB:20:02:07 50:06:01: 6B:BB:20:02:0704 50:06:01: 64 :BB:20:02:07 50:06:01: 6C :BB:20:02:07

    05 50:06:01: 65 :BB:20:02:07 50:06:01: 6D :BB:20:02:07

    06 50:06:01: 66 :BB:20:02:07 50:06:01: 6E :BB:20:02:07

    07 50:06:01: 67 :BB:20:02:07 50:06:01: 6F :BB:20:02:07

    08 50:06:01: 60 :BB:2 1:02:07 50:06:01: 68 :BB:2 1:02:07

    09 50:06:01: 61 :BB:2 1:02:07 50:06:01: 69 :BB:2 1:02:07

    10 50:06:01: 62 :BB:2 1:02:07 50:06:01: 6A:BB:2 1:02:07

    11 50:06:01: 63 :BB:2 1:02:07 50:06:01: 6B :BB:2 1:02:07

  • 8/13/2019 CX4 Series Arrays

    59/67

    Port Numbering

    Ports are assigned as they are added to an enclosure Base ports will remain the same Additional ports will be numbered in the order they are

    added

    Physical Ports are displayed by Slot/PortLogical Ports are assigned as ports are persisted

    Port mapping can be found in Navisphere under portmanagement

  • 8/13/2019 CX4 Series Arrays

    60/67

  • 8/13/2019 CX4 Series Arrays

    61/67

    Select your training path

    2U CHASSIS

    4U CHASSIS

    Click here if both Chassis sections arecompleted

  • 8/13/2019 CX4 Series Arrays

    62/67

    Navisphere Domains

    To Manage CX4 Arrays the Navi UI must be release 28In a storage domain with multiple storage systems ofdifferent generations the domain master must be one

    of the following. CX4 series on Release 28 CX3 series on Release 26 CX series on Release 24

    OrOff Array management must be used where theNavisphere UI version is release 28

  • 8/13/2019 CX4 Series Arrays

    63/67

    Zoning

    Open zoning to be used with caution More Front end ports Maximum initiator counts per SP

    World wide names based on logical port number not thephysical port number

  • 8/13/2019 CX4 Series Arrays

    64/67

    Mirrorview Ports

    No longer just the highest port on the ArrayMirrorview ports are assigned by Flare at initial Poweron of array

    If additional Front end ports are added the Mirrorviewport will remain in the same place

    At initial Power on Highest FC Front end port

    Highest iSCSI PortThis assignment is done regardless of enablers

  • 8/13/2019 CX4 Series Arrays

    65/67

    Private Space

    Listed DiskCapacity

    Drive Type Flare DiskCapacity

    146GB 4GB FC 71.7GB

    300GB 4GB FC 206.4GB

    400GB 4GB FC 304.8GB

    1000GB SATA 855.2GB

  • 8/13/2019 CX4 Series Arrays

    66/67

  • 8/13/2019 CX4 Series Arrays

    67/67

    End of Module